20.11.2014 Views

Siemens Masterdrive MC Quick Startup Guide - Wittenstein

Siemens Masterdrive MC Quick Startup Guide - Wittenstein

Siemens Masterdrive MC Quick Startup Guide - Wittenstein

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Quick</strong> <strong>Startup</strong> <strong>Guide</strong> TPM +<br />

5.3 TPM + 560 V Ratio 31<br />

Code Description TPM004<br />

S<br />

TPM010<br />

S<br />

TPM025<br />

S<br />

TPM050<br />

S<br />

TPM110<br />

S<br />

Stator length 30 30 45 60 75<br />

P060 Menu select 5 5 5 5 5<br />

P071 Line volts [Vrms] 400 400 400 400 400<br />

P095 Select Mot Type 3 3 3 3 3<br />

P102 Motor Rtd Amps [Arms] 1,00 1,20 5,60 13,40 16,30<br />

P109 Motor #Pole Pairs 4 4 6 6 6<br />

P113 Mot Rtd Torque 0,70 1,20 5,50 13,50 16,40<br />

P120 Main Field Induc [mH] 16,6 11,4 2,9 1,5 1,2<br />

P121 Stator Resist [mOhm] 14090 10650 1100 220 160<br />

P128 Max Current [Arms] 2,20 4,70 14,30 29,80 70,00<br />

P130 Select MotEncod<br />

2-pole resolver (SBR) 1 1 1 1 1<br />

SinCos encoder Singleturn / 4 4 4 4 4<br />

Multiturn Heidenhain<br />

Incremental encoder ERN1185 3 3 3 3 3<br />

P131 Select TmpSensor 1 1 1 1 1<br />

P132 Angle Offset 0 0 0 0 0<br />

P136 Encoder pulse# 512 512 512 512 512<br />

P147 SelectMultiturn 1<br />

Singleturn ECN1113 9 9 9 9 9<br />

Multiturn EQN1125 8 8 8 8 8<br />

P290 Sel V/f, I-Reg 0 Vectorial current control<br />

P296 Dynamic I-Reg 0 Highest dynamic response<br />

P340 SamplingFreq [kHz] 10 10 10 10 10<br />

P350 Ref Amps [Arms] 2 2,20 4,70 14,30 29,80 70,00<br />

P351 Ref Volts [Vrms] 400 400 400 400 400<br />

P352 Ref Frequency [Hz] 3 400 400 600 500 500<br />

P353 Ref Speed [1/min] 3 6000 6000 6000 5000 5000<br />

P354 Ref Torque [Nm] 2 1,4 3,4 10,3 22,3 43,9<br />

P452 n (max, FWDSpeed) [%] 3 100 100 100 100 100<br />

P453 n (max, REVSpeed) [%] 3 100 100 100 100 100<br />

P060 Return menu select 1 1 1 1 1<br />

Based on the default settings the speed loop can be optimized by the parameters P223, P235 and P240.<br />

1 In case of using firmware revisions < 2.4 the setup of the encoders ECN1113 and EQN1125 cannot be done with the<br />

parameter P147. The setup of the encoder has to be done manually with the following parameters:<br />

ECN1113: P147=0, P148.001=9, P148.002=0, P149.001=0x101, P149.002=0x13<br />

EQN1125: P147=0, P148.001=9, P148.002=12, P149.001=0x101, P149.002=0x25<br />

2 The Ref values for current / torque are set to maximum. Continuous operation is not possible with this setting. Please adjust<br />

according to your application.<br />

3 The Ref values for frequency / speed are set to maximum. Please adjust according to your application.<br />

Page en-11<br />

Revision: 02 4091-D015929 Release: 07.10.2008

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!