5.3 TPM + 560 V Ratio 31<br />
Code Description TPM004<br />
S<br />
TPM010<br />
S<br />
TPM025<br />
S<br />
TPM050<br />
S<br />
TPM110<br />
S<br />
Stator length 30 30 45 60 75<br />
P060 Menu select 5 5 5 5 5<br />
P071 Line volts [Vrms] 400 400 400 400 400<br />
P095 Select Mot Type 3 3 3 3 3<br />
P102 Motor Rtd Amps [Arms] 1,00 1,20 5,60 13,40 16,30<br />
P109 Motor #Pole Pairs 4 4 6 6 6<br />
P113 Mot Rtd Torque 0,70 1,20 5,50 13,50 16,40<br />
P120 Main Field Induc [mH] 16,6 11,4 2,9 1,5 1,2<br />
P121 Stator Resist [mOhm] 14090 10650 1100 220 160<br />
P128 Max Current [Arms] 2,20 4,70 14,30 29,80 70,00<br />
P130 Select MotEncod<br />
2-pole resolver (SBR) 1 1 1 1 1<br />
SinCos encoder Singleturn / 4 4 4 4 4<br />
Multiturn Heidenhain<br />
Incremental encoder ERN1185 3 3 3 3 3<br />
P131 Select TmpSensor 1 1 1 1 1<br />
P132 Angle Offset 0 0 0 0 0<br />
P136 Encoder pulse# 512 512 512 512 512<br />
P147 SelectMultiturn 1<br />
Singleturn ECN1113 9 9 9 9 9<br />
Multiturn EQN1125 8 8 8 8 8<br />
P290 Sel V/f, I-Reg 0 Vectorial current control<br />
P296 Dynamic I-Reg 0 Highest dynamic response<br />
P340 SamplingFreq [kHz] 10 10 10 10 10<br />
P350 Ref Amps [Arms] 2 2,20 4,70 14,30 29,80 70,00<br />
P351 Ref Volts [Vrms] 400 400 400 400 400<br />
P352 Ref Frequency [Hz] 3 400 400 600 500 500<br />
P353 Ref Speed [1/min] 3 6000 6000 6000 5000 5000<br />
P354 Ref Torque [Nm] 2 1,4 3,4 10,3 22,3 43,9<br />
P452 n (max, FWDSpeed) [%] 3 100 100 100 100 100<br />
P453 n (max, REVSpeed) [%] 3 100 100 100 100 100<br />
P060 Return menu select 1 1 1 1 1<br />
Based on the default settings the speed loop can be optimized by the parameters P223, P235 and P240.<br />
1 In case of using firmware revisions < 2.4 the setup of the encoders ECN1113 and EQN1125 cannot be done with the<br />
parameter P147. The setup of the encoder has to be done manually with the following parameters:<br />
ECN1113: P147=0, P148.001=9, P148.002=0, P149.001=0x101, P149.002=0x13<br />
EQN1125: P147=0, P148.001=9, P148.002=12, P149.001=0x101, P149.002=0x25<br />
2 The Ref values for current / torque are set to maximum. Continuous operation is not possible with this setting. Please adjust<br />
according to your application.<br />
3 The Ref values for frequency / speed are set to maximum. Please adjust according to your application.<br />
Page en-11<br />