WARP9 - Kim Lighting
WARP9 - Kim Lighting
WARP9 - Kim Lighting
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
SITE /ROADWAY<br />
<strong>WARP9</strong><br />
TM<br />
The first outdoor luminaire designed<br />
not to be seen, using Visual Stealth Technology. TM
TM<br />
THE FUTURE OF SITE/ROADWAY LIGHTING<br />
<strong>Kim</strong>’s Theory of Relativity<br />
A Concealment Approach<br />
Low Visual Signature Technology<br />
Advanced Performance Features<br />
Optical Design Features<br />
Mechanical Features<br />
Installation & Maintenance Features<br />
Ordering Information<br />
Luminaire Specifications<br />
Lamp Guide<br />
2<br />
4<br />
6<br />
8<br />
10<br />
12<br />
14<br />
16<br />
18<br />
20<br />
MAILING ADDRESS<br />
P.O. BOX 60080<br />
CITY OF INDUSTRY, CA<br />
91716-0080<br />
BUSINESS ADDRESS<br />
16555 EAST GALE AVENUE<br />
CITY OF INDUSTRY, CA 91745<br />
PHONE: 626.968.5666<br />
FAX: 626.369.2695<br />
ENTIRE CONTENTS<br />
© COPYRIGHT 2011 KIM LIGHTING INC.<br />
ALL RIGHTS RESERVED<br />
REPRODUCTION IN WHOLE OR IN PART<br />
WITHOUT PERMISSION IS STRICTLY PROHIBITED.<br />
U.S. PATENT D568,521<br />
www.kimlighting.com<br />
Printed in U.S.A.<br />
5508811200<br />
Version 1.3 (7/19/11)<br />
Hubbell<br />
<strong>Lighting</strong>, Inc.
<strong>WARP9</strong> TM<br />
Fixture/Background<br />
photo<br />
Low Visual Signature Luminaire<br />
<strong>WARP9</strong> is a new concept in luminaire design – visual stealth. Typical site lighting attempts to<br />
embellish, decorate, or adorn, often beyond the original architectural intent. <strong>WARP9</strong> was<br />
conceived and developed with an entirely different directive. <strong>WARP9</strong> was designed to disappear<br />
from the site, camouflage itself within its surroundings, and avoid detection from daytime visual<br />
perception. <strong>WARP9</strong> is the antithesis of massive, showy, recognizable, and ornamental design,<br />
allowing architecture to remain visually dominant as it was originally intended. <strong>WARP9</strong><br />
is a concept that is long overdue, yet one that is light years ahead of its time.<br />
KIM LIGHTING 1
<strong>WARP9</strong> TM<br />
<strong>Kim</strong>’s Theory of Relativity<br />
The Complete Design Solution<br />
From Parking Lot to Building • Proper Scale • Coordinated Design<br />
Site/Roadway Zone<br />
Parking lots and roadways require luminaires on<br />
20'-40' poles to efficiently light these large areas.<br />
Therefore, this lighting sets the design style for all<br />
other lighting zones as you progress towards the<br />
building. Select <strong>WARP9</strong>L large version luminaires<br />
with round poles for this zone.<br />
Pedestrian Zone<br />
As an observer leaves the parking lot and transitions<br />
to pedestrian areas, poles should decrease in height to<br />
10' – 16'. In addition, luminaires should decrease in<br />
scale, as human perception of proportion is keen at<br />
this level. Select <strong>WARP9</strong>’s small version luminaires for<br />
this zone, and select a finish that will integrate well<br />
with the fixture’s primary background elements.<br />
2 KIM LIGHTING
<strong>WARP9</strong> TM<br />
Landscape/Pathway Zone<br />
Near the building, luminaires should continue to<br />
disappear, blending into the landscape and hardscape<br />
elements. Select from a wide range of low voltage, line<br />
voltage, and LED landscape luminaires, or <strong>Kim</strong> <strong>Lighting</strong>’s<br />
VRB and GEM bollard series to integrate<br />
with <strong>WARP9</strong>’s curvilinear form.<br />
Building/Perimeter Zone<br />
Avoid installing pole-mounted luminaires close to the<br />
building, as they tend to dominate the architecture.<br />
However, if required, <strong>WARP9</strong> is the best solution to<br />
integrate with architectural proximity. <strong>Kim</strong> <strong>Lighting</strong><br />
suggests <strong>WARP9</strong> wall mounted luminaires to reduce<br />
daytime detection of building mounted equipment.<br />
KIM LIGHTING 3
<strong>WARP9</strong> TM<br />
A Concealment Approach<br />
<strong>WARP9</strong>’s efficient and low profile compound curve design results in a close<br />
synergy between aerodynamic performance, illumination performance, and its<br />
ability to limit cross section visibility. When installed with the right scale,<br />
finish and placement, <strong>WARP9</strong>’s sophisticated and complex camouflage scheme<br />
achieves a unique level of concealment and subtle presence never before<br />
offered in an architectural luminaire.<br />
Product Overview:<br />
<strong>Kim</strong> <strong>Lighting</strong>’s <strong>WARP9</strong> series offers a complete package of luminaire sizes<br />
and options to integrate seamlessly into any environment, natural or<br />
man-made. Choose from two housing sizes in electronic or magnetic<br />
ballasted versions, and select one of four distinct light distributions and a<br />
wide variety of mounting, fixture, and finish options to complete your<br />
<strong>WARP9</strong> visual stealth concept.<br />
Four Housing Configurations<br />
WP9SE WP9LE WP9SM WP9LM<br />
Four Distinct Distributions<br />
TYPE II TYPE III TYPE IV TYPE V Sq<br />
Multiple Options<br />
Wall Mount Pole Mount SLX Lexan ®<br />
Lens<br />
4 KIM LIGHTING<br />
Houseside<br />
Shield<br />
Tamper<br />
Resistant<br />
Latch<br />
New<br />
Stealth Gray TM<br />
Finish
<strong>WARP9</strong> TM<br />
WP9LE<br />
WP9LM<br />
WP9SE<br />
WP9SM<br />
KIM LIGHTING 5
<strong>WARP9</strong> TM<br />
Low Visual Signature Technology<br />
DESIGN LOGIC:<br />
The Disappearing Act<br />
Modern technology produced <strong>Kim</strong> <strong>Lighting</strong>’s<br />
new <strong>WARP9</strong> luminaires, but the camouflage<br />
principles behind it were learned instinctively<br />
from nature thousands of years ago. <strong>WARP9</strong>’s<br />
fundamental approach is the same as those<br />
used by wildlife and hunters for millennia:<br />
hide, blend, and deceive.<br />
There are two basic elements of camouflage:<br />
shape and color.<br />
<strong>WARP9</strong> capitalizes on both of these<br />
principles in unique ways to reduce<br />
perceptual attraction and luminaire detection.<br />
First, <strong>WARP9</strong> utilizes a computer generated<br />
low-profile compound curve design to create<br />
a natural compact top arc that reflects the<br />
sky from normal viewing angles. This breaks<br />
up the luminaire’s outline, disrupting its<br />
silhouette and evening out its 3-dimensional<br />
surface, making it more difficult to see as one<br />
object. This reduces visual mass, and allows<br />
the viewer to envision the entire site without<br />
disruptive and massive luminaire shapes to<br />
draw attention away from architecture and<br />
landscape. Second, <strong>WARP9</strong> utilizes a hollow<br />
mounting arm that gracefully blends with the<br />
housing, and minimizes its visual signature.<br />
<strong>Kim</strong> <strong>Lighting</strong> has also developed a unique<br />
color scheme to further reduce the<br />
luminaire’s visual signature.<br />
VISUAL STEALTH TECHNOLOGY :<br />
New Stealth Gray Finish<br />
Color is essential to camouflage, as its similarity to<br />
the primary background will tend to break up that<br />
area of the outline and blend the shape away from<br />
normal detection. Over 100 painted samples were<br />
tested and reviewed to determine how well they<br />
matched the predominant colors of contemporary<br />
architecture, typical horizons, and northern<br />
hemisphere skies. These were then narrowed down<br />
to a few prototype samples that were field tested<br />
for visual acuity, perception attraction, and detection<br />
reduction. The result is <strong>Kim</strong> <strong>Lighting</strong>’s new Stealth<br />
Gray finish option featuring a light gray hue<br />
suitable for any outdoor environment. However,<br />
designers can select from a wide variety of standard<br />
and custom finishes depending on application and<br />
immediate background surface coloration.<br />
6 KIM LIGHTING
<strong>WARP9</strong> TM<br />
FPO<br />
AERODYNAMICS:<br />
Small Size • Low EPA<br />
Specify <strong>Kim</strong> <strong>Lighting</strong>’s new Stealth Gray finish to<br />
further reduce the fixture’s visual signature.<br />
Featuring a light gray semi-gloss surface, Stealth<br />
Gray is a result of an extensive study of finishes<br />
and paints for typical application scenarios in<br />
natural or architectural environments.<br />
A welcomed result of <strong>WARP9</strong>’s thin design is a<br />
very low EPA rating, suitable for installation in<br />
almost any environment, including high wind,<br />
coastal, and hurricane prone locations. <strong>Kim</strong> <strong>Lighting</strong><br />
recommends mounting <strong>WARP9</strong> luminaires on<br />
round poles to further improve aerodynamics<br />
and lend to the fixture’s camouflaged appearance.<br />
Round poles have less visual signature than<br />
square poles.<br />
<strong>WARP9</strong> Small Housing and Arm EPA (WP9SE): 0.52<br />
<strong>WARP9</strong> Large Housing and Arm EPA (WP9LE): 0.95<br />
Note: Pole selection and height will also<br />
determine final EPA allowance for your application.<br />
KIM LIGHTING 7
<strong>WARP9</strong> TM<br />
Advanced Performance Features<br />
High Performance • Low Profile<br />
<strong>WARP9</strong>’s super low profile housing does not<br />
mean a compromise in illumination performance.<br />
In fact, an entire new series of reflector systems<br />
was specifically developed through a highly<br />
detailed computer study of efficiency and lamp<br />
output maximization. These new systems feature<br />
highly specular 95% reflective Alzak finishing,<br />
tooled and assembled by hand at <strong>Kim</strong> <strong>Lighting</strong>’s<br />
California facilities to maintain the highest quality<br />
and performance standards. Choose from IES<br />
Type II, III, IV, and V Sq distributions, rotatable for<br />
any application or distribution requirement.<br />
Full Cutoff: StarView Compliant<br />
<strong>Kim</strong> <strong>Lighting</strong>'s StarView products meet IES<br />
and IDA full cutoff requirements for use where<br />
light pollution or light trespass may be a concern,<br />
and to promote the enjoyment of celestial<br />
visibility at night.<br />
<strong>WARP9</strong> utilizes a horizontal lamp orientation<br />
with a flat glass lens to produce full cutoff with<br />
zero light above 90° horizontal. Therefore, all<br />
<strong>WARP9</strong> fixtures are StarView compliant and<br />
are approved for full cutoff applications in<br />
any jurisdiction.<br />
<strong>WARP9</strong> also offers a house-side shield option<br />
where light trespass and control of spill light<br />
onto adjacent property may be a concern.<br />
WP9L = 5K"<br />
WP9S = 4B"<br />
8 KIM LIGHTING
<strong>WARP9</strong> TM<br />
Four Distinct Light Distributions<br />
Site configuration determines the combination of<br />
light distributions required to efficiently illuminate<br />
desired areas. <strong>WARP9</strong> is available in four highly<br />
efficient light patterns, combined with seven<br />
mounting arrangements and rotatable optics for<br />
incredible design versatility and flexibility. Contact<br />
<strong>Kim</strong> <strong>Lighting</strong> for free layout and application<br />
planning services, if needed.<br />
1A 2B 2L 3T 3Y 4C 1W<br />
Type II Type III Type IV Type V Sq<br />
KIM LIGHTING 9
<strong>WARP9</strong> TM<br />
Optical Design Features<br />
Advanced Heat Management<br />
<strong>WARP9</strong>’s die-cast housing is a homogeneous<br />
component in which every feature has a<br />
functional purpose. HID lamps produce significant<br />
heat, yet are operated by temperature sensitive<br />
electrical components. Because of its compact,<br />
low profile size, new methods of controlling heat<br />
were required for <strong>WARP9</strong>. A combination of<br />
cooling ribs, ventilation, and a solid barrier wall<br />
between the optical chamber and the ballast<br />
compartment are employed to control operating<br />
temperatures for maximum component life.<br />
Rotatable Optics<br />
All <strong>WARP9</strong> reflectors are field rotatable in 90°<br />
increments. This allows design flexibility in<br />
producing very high illumination levels for special<br />
applications, or for maintaining a consistent fixture<br />
orientation throughout the site. Each reflector is<br />
labeled to show the orientation of the light<br />
pattern, and can be field adjusted after<br />
initial installation.<br />
For applications requiring high light levels, such as<br />
sports facilities, auto dealerships, or service<br />
stations, reflectors can be aimed in parallel to<br />
double illumination levels.<br />
10 KIM LIGHTING
<strong>WARP9</strong> TM<br />
Four rotatable reflector<br />
options featuring new 95%<br />
Alzak reflectivity<br />
Horizontal lamp orientation for<br />
uniformity and cutoff control<br />
One-piece silicone gasket<br />
with high memory retention<br />
Barrier wall completely<br />
separates optical chamber<br />
from electrical components<br />
Unique low profile<br />
frameless lens<br />
Totally sealed optical<br />
chamber stays clean for<br />
decades<br />
Multiple HID lamp options,<br />
electronic or magnetic<br />
ballasted versions<br />
Unique Frameless Lens<br />
<strong>WARP9</strong> employs a unique frameless lens for<br />
several purposes. For improved camouflaging, the<br />
frameless lens lends to the sleek profile and<br />
reduced mass of the housing envelope, also<br />
reducing the amount of geometrical and straight<br />
lines that tend to attract the human eye. Second,<br />
the frameless lens allows for a consistent and<br />
positive gasket seal to completely isolate the<br />
optical chamber from moisture, air, and insect<br />
entry. Finally, fewer component pieces reduce<br />
overall fixture weight and improve allowable EPA.<br />
Multiple Lamp Options<br />
42W<br />
57W<br />
60W<br />
70W •/+ + •<br />
85W<br />
PMH MH HPS PL IF<br />
•<br />
•<br />
•<br />
•<br />
100W •/+ + •<br />
150W •/+ + •<br />
175W +<br />
200W •/+<br />
250W •/+ + +<br />
320W •/+<br />
350W •/+<br />
400W •/+ + +<br />
PMH = Pulse Start Metal Halide<br />
MH = Metal Halide<br />
HPS = High Pressure Sodium<br />
PL = Compact Fluorescent<br />
IF = Induction Fluorescent<br />
WP9SE / WP9LE(electronic) = •<br />
WP9SM / WP9LM(magnetic) = +<br />
KIM LIGHTING 11
<strong>WARP9</strong> TM<br />
Mechanical Features<br />
•<br />
•<br />
Aluminum<br />
Titanated Zirconium<br />
Conversion Coating<br />
Powder Coat<br />
•<br />
New<br />
Stealth<br />
Gray TM Finish<br />
Diecast Aluminum Components<br />
Durable Powder Coat Finish<br />
<strong>WARP9</strong>’s housing and arm assembly are die-cast, low<br />
copper alloy (
<strong>WARP9</strong> TM<br />
Completely new field-rotatable reflector<br />
systems with 95% reflectivity<br />
<strong>Kim</strong> <strong>Lighting</strong>’s durable Super<br />
TGIC powder coat paint<br />
finish, featuring Stealth Gray <br />
Concealed die-cast<br />
no-tool latch allows easy<br />
access to optical chamber<br />
One-piece silicone<br />
gaskets assure positive seal<br />
after relamping<br />
Integrated cooling<br />
ribs for advanced<br />
heat management<br />
Die-cast aluminum<br />
arm attachment<br />
Die-cast aluminum housing<br />
Isolated wiring and electrical<br />
component chamber<br />
KIM LIGHTING 13
<strong>WARP9</strong> TM<br />
Installation & Maintenance Features<br />
Easy Installation and Set-Up<br />
No-Tool Maintenance<br />
The attachment of lighting fixtures to poles is often a<br />
neglected detail that ruins a clean design with boxy<br />
armatures and exposed nuts, bolts, or screws. <strong>WARP9</strong>’s<br />
arm connection naturally integrates and blends with the<br />
fixture head for a clean, strong appearance without<br />
exposed hardware or attachments. <strong>WARP9</strong> also utilizes<br />
an internal mounting-bolt system concealed within the<br />
arm, fixture, and pole for maximum rigidity and<br />
assured coupling.<br />
Inside the pole top, a reinforcing plate receives the mounting<br />
bolts. A strain relief is provided on the reinforcing plate<br />
for securing the field wires. The cast-aluminum arm has<br />
concealed mounting bolts accessible through a flush cover<br />
that blends with the arm pre-assembled at <strong>Kim</strong> <strong>Lighting</strong>.<br />
The arm is configured to complement the fixture design<br />
and make the fixture-to-pole connection look natural,<br />
logical, and homogeneous.<br />
Ease of maintenance is a feature that distinguishes a<br />
lifetime product from an inferior substitution. <strong>WARP9</strong><br />
utilizes modular construction for easy installation and<br />
maintenance, and to allow for upgrading as lamp<br />
technology advances.<br />
To reduce expensive lift-truck rental time, relamping can<br />
be quickly accomplished without tools. A single latch on<br />
the nose of the fixture opens the hinged frameless lens. If<br />
ballast replacement is required, the entire electrical<br />
module is accessed through a separate latched door on<br />
the underside of the fixture, and includes quick-disconnect<br />
plugs on all wiring. A spare electrical module can be<br />
quickly inserted to eliminate downtime, while the old<br />
module can be repaired and stored for future use.<br />
14 KIM LIGHTING
<strong>WARP9</strong> TM<br />
Proportion Guide<br />
Electronic ballast versions shown.<br />
KIM LIGHTING 15
<strong>WARP9</strong> TM<br />
Ordering Information<br />
1 Mounting:<br />
Ordering Example:<br />
For standard fixture and pole<br />
3Y configuration is available for<br />
round poles only.<br />
Mounting Fixture Electrical Module Finish Options Pole VSF Option<br />
2SB /WP9LE3/ 250PMH277 / SG-P/ A-25 / PRA20-4188SB / SG-P / VSF-2SB<br />
1 2 3 4 5-11 12 13<br />
See separate <strong>Kim</strong> Pole Catalog.<br />
Omit for 1W Wall Mount.<br />
Plan View:<br />
EPA WP9L: 0.95 1.9 1.47 2.4 2.4 2.7 n/a<br />
EPA WP9S: 0.52 1.04 0.82 1.3 1.3 1.5 n/a<br />
Cat. No.: 1SA 2SB 2SL 3ST 3SY 4SC 1SW<br />
Wall<br />
Mount<br />
2 Fixture:<br />
Cat. No. designates fixture and<br />
light distribution<br />
3 Electrical Module:<br />
PMH = Pulse Start<br />
Metal Halide<br />
MH = Metal Halide<br />
HPS = High Pressure Sodium<br />
PL<br />
= Compact Fluorescent<br />
IF = Induction Fluorescent<br />
See lamp and electrical data<br />
on pages 20-21<br />
Light Distribution: Type II Type III Type IV Type V<br />
Forward Throw<br />
Square<br />
Full Cutoff Full Cutoff Full Cutoff Full Cutoff<br />
Warp9 Small<br />
Electronic Ballast: WP9SE2 WP9SE3 WP9SE4 WP9SE5<br />
Warp9 Small WP9SM2 WP9SM3 WP9SM4 WP9SM5<br />
Magnetic Ballast:<br />
Warp9 Large<br />
Electronic Ballast: WP9LE2 WP9LE3 WP9LE4 WP9LE5<br />
Warp9 Large WP9LM2 WP9LM3 WP9LM4 WP9LM5<br />
Magnetic Ballast:<br />
Warp9 - Small / Electronic<br />
Pulse Start<br />
Metal Halide<br />
70PMH120<br />
70PMH208<br />
70PMH240<br />
70PMH277<br />
100PMH120<br />
100PMH208<br />
100PMH240<br />
100PMH277<br />
150PMH120<br />
150PMH208<br />
150PMH240<br />
150PMH277<br />
Compact<br />
Fluorescent<br />
42PL120<br />
42PL208<br />
42PL240<br />
42PL277<br />
57PL120<br />
57PL208<br />
57PL240<br />
57PL277<br />
Warp9 - Large / Electronic<br />
Pulse Start<br />
Metal Halide<br />
200PMH120<br />
200PMH208<br />
200PMH240<br />
200PMH277<br />
250PMH208<br />
250PMH240<br />
250PMH277<br />
320PMH208<br />
320PMH240<br />
320PMH277<br />
350PMH208<br />
350PMH240<br />
350PMH277<br />
400PMH208<br />
400PMH240<br />
400PMH277<br />
Induction<br />
Fluorescent*<br />
100IF120 150IF120<br />
100IF208 150IF208<br />
100IF240 150IF240<br />
100IF277 150IF277<br />
100IF347 150IF347<br />
100IF480 150IF480<br />
* Available in Type I I<br />
distribution only<br />
Lamp Lamp Line<br />
Watts Type Volts<br />
250 PMH 277<br />
Warp9 - Small / Magnetic<br />
Pulse Start<br />
Metal Halide<br />
70PMH120 150PMH120<br />
70PMH208 150PMH208<br />
70PMH240 150PMH240<br />
70PMH277 150PMH277<br />
70PMH347 150PMH347<br />
70PMH480 150PMH480<br />
100PMH120<br />
100PMH208<br />
100PMH240<br />
100PMH277<br />
100PMH347<br />
100PMH480<br />
High Pressure<br />
Sodium<br />
70HPS120<br />
70HPS208<br />
70HPS240<br />
70HPS277<br />
70HPS347<br />
70HPS480<br />
100HPS120<br />
100HPS208<br />
100HPS240<br />
100HPS277<br />
100HPS347<br />
100HPS480<br />
150HPS120<br />
150HPS208<br />
150HPS240<br />
150HPS277<br />
150HPS347<br />
150HPS480<br />
Metal Halide<br />
175MH120<br />
175MH208<br />
175MH240<br />
175MH277<br />
175MH347<br />
175MH480<br />
Warp9 - Large / Magnetic<br />
Pulse Start<br />
High Pressure<br />
Metal Halide<br />
Sodium<br />
200PMH120 350PMH120 150HPS120<br />
200PMH208 350PMH208 150HPS208<br />
200PMH240 350PMH240 150HPS240<br />
200PMH277 350PMH277 150HPS277<br />
200PMH347 350PMH347 150HPS347<br />
200PMH480 350PMH480 150HPS480<br />
250PMH120 400PMH120 250HPS120<br />
250PMH208 400PMH208 250HPS208<br />
250PMH240 400PMH240 250HPS240<br />
250PMH277 400PMH277 250HPS277<br />
250PMH347 400PMH347 250HPS347<br />
250PMH480 400PMH480 250HPS480<br />
320PMH120<br />
400HPS120<br />
320PMH208<br />
400HPS208<br />
320PMH240<br />
400HPS240<br />
320PMH277<br />
400HPS277<br />
320PMH347<br />
400HPS347<br />
320PMH480<br />
400HPS480<br />
Metal Halide<br />
175MH120<br />
175MH208<br />
175MH240<br />
175MH277<br />
175MH347<br />
175MH480<br />
250MH120<br />
250MH208<br />
250MH240<br />
250MH277<br />
250MH347<br />
250MH480<br />
400MH120<br />
400MH208<br />
400MH240<br />
400MH277<br />
400MH347<br />
400MH480<br />
16 KIM LIGHTING
<strong>WARP9</strong> TM<br />
4 Finish:<br />
Super TGIC powder coat<br />
paint over titanated zirconium<br />
conversion coating.<br />
(see page 12)<br />
Color: Black Dark Bronze Stealth Gray TM Platinum Silver White Custom Colors<br />
Cat. No.: BL-P DB-P SG-P PS-P WH-P CC-P<br />
Consult your <strong>Kim</strong><br />
<strong>Lighting</strong> representative<br />
for custom colors.<br />
5 Wall Mounting:<br />
Cat. No.: 1W<br />
A cast-aluminum mounting plate is mounted to the wall with four bolts<br />
(by others). Fixture and arm are mounted to the cast aluminum cover<br />
plate before attaching to the wall mounting plate. The fixture-arm-cover<br />
plate assembly is hooked to the wall mounting plate and secured with<br />
stainless steel screws provided. Field splices are made at the opening<br />
in the cover plate. Cover is finished to match arm and fixture color.<br />
6 Optional Photocell<br />
Button<br />
Receptacle<br />
Cat. No.: A-25<br />
Receptacle<br />
A-30 - A-35<br />
Button<br />
Two types of photocell controls are available. A receptacle for a NEMA<br />
base photocell (by others) would be located above the electrical<br />
compartment. For all multiple-fixture pole mountings with two or three<br />
fixtures, one fixture has a receptacle to operate the others. Four fixtures<br />
(250 watt or less) also require one fixture with a receptacle. Four fixtures<br />
(400 watt) require two fixtures with receptacles. Also available is an internal<br />
photocell with a button sensor on the left side of the fixture. For multiplefixture<br />
pole mountings, one fixture has a photocell to operate the others.<br />
7 Optional SLX Lexan ®<br />
Non-Yellowing Lens:<br />
SLX Lexan Lens<br />
Cat. No.: SLX<br />
One-piece non-yellowing vacuum formed advanced polymer<br />
(SLX Lexan from GE Advanced Materials) enclosure covers standard<br />
tempered glass lens.<br />
CAUTION: Use only when vandalism is anticipated to be high.<br />
8 Optional Houseside<br />
Shield:<br />
HS for flat lens<br />
Cat. No.: HS<br />
Recommended for use with clear lamps only. Effectiveness is reduced<br />
for coated lamps. Not for use with Type V Sq light distributioons.<br />
9 Optional Neighbor<br />
Friendly Shield:<br />
Cat. No.: NFS<br />
(Type IV only) Stamped internal shield and blocking panels are used<br />
todirect and redirect lighting into a forward throw distribution. The<br />
amountof light directed and redirected toward the back of the luminaire<br />
isdramatically reduced to create extremely low glare behind the pole.<br />
Only available on the Type IV reflectors.<br />
10 Optional Tamper-<br />
Resistant Latch:<br />
Tamper-Resistant Latch<br />
Cat. No.: TL<br />
Standard die-cast latch is provided with a captive 10-32 stainless steel flat<br />
socket-head screw to prevent unauthorized opening. Required only for<br />
vandal protection in locations where fixtures can be reached by<br />
unauthorized persons.<br />
11 Optional Horizontal<br />
Slipfitter Mount:<br />
Slipfitter<br />
Cat. No.: HSF<br />
Replaces standard mounting arm with a slipfitter for mounting to a<br />
horizontal pole davit-arm with 2" pipe-size mounting end (2C" O.D.).<br />
Provides ±5° vertical fixture adjustment.<br />
12 Special Options for<br />
Street <strong>Lighting</strong>:<br />
Cat. No.: TB<br />
Terminal Block located inside the fixture electrical compartment. (For Large Only)<br />
13 Poles:<br />
14 Optional Vertical<br />
Slipfitter Mounts:<br />
See <strong>Kim</strong> Pole Catalog for a complete selection of square and round poles in aluminum or steel.<br />
Round<br />
Cat. No. Cat. No Mounting Configuration<br />
VSF-1SA SVSF-1SA 1SA - Single arm mount<br />
VSF-2SB SVSF-2SB 2SB - 2 at 180°<br />
VSF-2SL SVSF-2SL 2SL - 2 at 90°<br />
VSF-3ST SVSF-3ST 3ST - 3 at 90°<br />
VSF-3SY Square<br />
3SY - 3 at 120°<br />
VSF-4SC SVSF-4SC 4SC - 4 at 90°<br />
Allows standard fixture and arm<br />
to be mounted to poles having a<br />
2" pipe-size tenon (2C" O.D. x 4K"<br />
min. length).<br />
KIM LIGHTING 17
<strong>WARP9</strong> TM<br />
Luminaire Specifications<br />
Dimensions - Electronic Ballast<br />
WP9LE<br />
Large Electronic Ballast<br />
200 to 400 watt PMH<br />
Mogul Base Lamps<br />
100 and 150 watt IF<br />
EPA: .95<br />
Maximum weight:<br />
35 lb. electronic<br />
WP9SE<br />
Small Electronic Ballast<br />
42 to 150 watt<br />
PMH and PL<br />
Medium Base Lamps<br />
EPA: .52<br />
Maximum weight:<br />
17 lb. electronic<br />
TOP<br />
TOP<br />
5K"<br />
(139.7 mm)<br />
35B"<br />
(892.2 mm)<br />
10M"<br />
(261.9 mm)<br />
4B"<br />
(104.7 mm)<br />
26I"<br />
(684.2 mm)<br />
8I"<br />
(227.0 mm)<br />
1I"<br />
(49.2 mm)<br />
FRONT<br />
10M"<br />
(261.9 mm)<br />
SIDE<br />
5I"<br />
(150.8 mm)<br />
1K"<br />
(38.1 mm)<br />
FRONT<br />
8I"<br />
(227.0 mm)<br />
SIDE<br />
5N"<br />
(141.3 mm)<br />
5B"<br />
(130.2 mm)<br />
4G"<br />
(112.7 mm)<br />
20"<br />
(508.0 mm)<br />
15"<br />
(381.0 mm)<br />
BOTTOM<br />
BOTTOM<br />
SPECIFICATIONS<br />
HOUSING: One-piece die-cast, low copper alloy (
<strong>WARP9</strong> TM<br />
Dimensions - Magnetic Ballast<br />
WP9LM<br />
Large Magnetic Ballast<br />
150 to 400 watt<br />
PMH, HPS and MH<br />
Mogul Base Lamps<br />
WP9SM<br />
Small Magnetic Ballast<br />
70 to 175 watt<br />
PMH, HPS and MH<br />
Medium Base Lamps<br />
EPA: .95<br />
Maximum weight:<br />
41 lb. magnetic<br />
TOP<br />
EPA: .52<br />
Maximum weight:<br />
21 lb. magnetic<br />
TOP<br />
5K"<br />
(139.7 mm)<br />
35B"<br />
(892.2 mm)<br />
10M"<br />
(261.9 mm)<br />
4B"<br />
(104.7 mm)<br />
26I"<br />
(684.2 mm)<br />
8I"<br />
(227.0 mm)<br />
1I"<br />
(49.2 mm)<br />
FRONT<br />
10M"<br />
(261.9 mm)<br />
SIDE<br />
5I"<br />
(150.8 mm)<br />
1K"<br />
(38.1 mm)<br />
FRONT<br />
8I"<br />
(227.0 mm)<br />
SIDE<br />
5N"<br />
(141.3 mm)<br />
5B"<br />
(130.2 mm)<br />
4G"<br />
(112.7 mm)<br />
20"<br />
(508.0 mm)<br />
15"<br />
(381.0 mm)<br />
BOTTOM<br />
BOTTOM<br />
KIM LIGHTING 19
<strong>WARP9</strong> TM<br />
Lamp Guide<br />
Lamp<br />
Watts<br />
Lamp<br />
Type<br />
System<br />
Watt<br />
Bulb<br />
Type<br />
Initial<br />
Lumens<br />
Life<br />
(Hours)<br />
PULSE START METAL HALIDE<br />
70 PMH 90 Clear, ED17, Med Base 6,200 16,000 M98 -30C HX-HPF 120 0.85 1.90 0.80 4<br />
Clear, T6, G12 Base 6,600 M143 208 0.52 1.00 0.50 3<br />
240 0.44 0.90 0.43 2<br />
277 0.39 0.80 0.39 2<br />
347 0.28 0.70 0.20 2<br />
480 0.23 0.50 0.26 2<br />
70 PMH 80 Clear, ED17, Med Base 6,200 16,000 M98 -30C Electronic 120 - - 0.67 4<br />
Clear, T6, G12 Base M143 208 - - 0.45 3<br />
M139 240 - - 0.38 2<br />
277 - - 0.30 2<br />
100 PMH 129 Clear, ED17, Med Base 9,000 16,000 M140 -30C HX-HPF 120 1.15 2.30 1.20 6<br />
208 0.66 1.40 0.80 4<br />
240 0.58 1.15 0.65 3<br />
277 0.50 1.00 0.60 3<br />
347 0.40 1.00 0.40 2<br />
480 0.30 0.55 0.30 2<br />
100 PMH 110 Clear, ED17, Med Base 9,000 16,000 M90 -30C Electronic 120 - - 0.92 6<br />
M140 208 - - 0.70 4<br />
240 - - 0.60 3<br />
277 - - 0.40 3<br />
150 PMH 185 Clear, ED17, Med Base 14,000 16,000 M102 -30C HX-HPF 120 1.60 3.65 1.75 10<br />
Clear, T6, G12 Base M142 208 1.00 2.10 1.30 5<br />
240 0.80 1.80 0.85 5<br />
277 0.70 1.58 0.77 4<br />
347 0.55 1.25 0.65 3<br />
480 0.42 0.81 0.45 3<br />
150 PMH 165 Clear, ED17, Med Base 14,000 16,000 M102 -30C Electronic 120 - - 1.40 10<br />
Clear, T6, G12 Base M142 208 - - 1.00 5<br />
240 - - 0.80 5<br />
277 - - 0.60 4<br />
200 PMH 240 Clear, T15, Mogul Base 19,000 15,000 M136 -30C Super 120 2.00 2.00 0.75 6<br />
CWA 208 1.20 1.20 0.40 4<br />
240 1.00 1.00 0.35 3<br />
277 0.85 0.85 0.30 3<br />
347 0.70 0.65 0.25 2<br />
480 0.50 0.50 0.18 2<br />
200 PMH 229 Clear, T15, Mogul Base 19,000 15,000 M136 -30C Electronic 120 - - 2.00 6<br />
208 - - 1.20 4<br />
240 - - 1.00 3<br />
277 - - 1.00 3<br />
250 PMH 295 Clear, BT28, Mogul Base 22,500 11,250 M138 -30C CWA 120 2.50 1.40 2.30 8<br />
M153 208 1.45 0.80 1.30 5<br />
240 1.25 0.70 1.15 5<br />
277 1.10 0.60 1.00 3<br />
347 0.95 0.75 0.45 3<br />
480 0.57 0.48 0.21 2<br />
250 PMH Clear, BT28, Mogul Base 22,500 11,250 M138 -30C Electronic 208 - - 1.36 5<br />
M153 240 - - 1.19 3<br />
277 - - 1.06 3<br />
320 PMH 368 Clear, BT28, Mogul Base 30,000 20,000 M132 -30C Super 120 3.25 2.30 1.80 8<br />
M154 CWA 208 1.90 1.35 1.05 6<br />
M170 240 1.65 1.15 0.90 5<br />
277 1.40 1.00 0.80 3<br />
347 1.10 0.80 0.70 3<br />
480 0.80 0.60 0.45 5<br />
320 PMH Clear, BT28, Mogul Base 30,000 20,000 M132 -30C Electronic 208 - - 1.70 8<br />
M154 240 - - 1.49 6<br />
M170 277 - - 1.32 5<br />
350 PMH 400 Clear, BT28, Mogul Base 33,000 20,000 M131 -30C Super 120 3.40 2.20 2.20 10<br />
M171 CWA 208 2.00 1.30 1.30 7<br />
240 1.70 1.10 1.10 5<br />
277 1.50 1.00 1.00 5<br />
347 1.20 0.80 0.85 3<br />
480 0.85 0.60 0.60 3<br />
350 PMH Clear, BT28, Mogul Base 33,000 20,000 M131 -30C Electronic 208 - - 1.84 10<br />
M171 240 - - 1.59 7<br />
277 - - 1.41 5<br />
400 PMH 452 Clear, BT28, Mogul Base 40,000 20,000 M135 -30C Super 120 4.00 3.00 3.50 10<br />
M155 CWA 208 2.30 1.75 2.00 7<br />
M172 240 2.00 1.50 1.75 5<br />
277 1.75 1.30 1.50 5<br />
347 1.35 0.75 1.10 4<br />
480 1.00 0.60 0.75 3<br />
400 PMH Clear, BT28, Mogul Base 40,000 20,000 M135 -30C Electronic 208 - - 2.10 10<br />
M155 240 - - 1.81 7<br />
M172 277 - - 1.59 5<br />
ANSI<br />
Code<br />
Starting<br />
Temp<br />
Circuit<br />
Type<br />
Voltage<br />
Operating<br />
Amps.<br />
Open<br />
Circuit<br />
Amps.<br />
Starting<br />
Amps.<br />
Min. Fuse<br />
Amps.<br />
20 KIM LIGHTING
<strong>WARP9</strong> TM<br />
Lamp<br />
Watts<br />
Lamp<br />
Type<br />
System<br />
Watt<br />
Bulb<br />
Type<br />
Initial<br />
Lumens<br />
Life<br />
(Hours)<br />
METAL HALIDE<br />
175 MH 210 Clear, ED17, Med Base 14,400 7,000 M57 -30C CWA 120 1.80 1.80 1.30 5<br />
208 1.04 1.04 0.75 3<br />
240 0.90 0.90 0.65 3<br />
277 0.80 0.80 0.55 2<br />
347 0.65 0.65 0.50 2<br />
480 0.45 0.45 0.35 2<br />
250 MH 295 Clear, BT28, Mogul Base 23,000 7,000 M58 -30C CWA 120 2.60 2.60 1.00 8<br />
208 1.50 1.50 0.60 5<br />
240 1.30 1.30 0.50 5<br />
277 1.10 1.10 0.45 3<br />
347 0.85 1.05 0.35 3<br />
480 0.65 0.65 0.30 2<br />
400 MH 458 Clear, BT28, Mogul Base 40,000 15,000 M59 -30C CWA 120 4.00 3.20 2.50 10<br />
208 2.30 1.80 1.40 7<br />
240 2.00 1.60 1.20 5<br />
277 1.70 1.50 1.00 5<br />
347 1.35 1.35 0.80 4<br />
480 1.00 0.75 0.90 3<br />
HIGH PRESSURE SODIUM<br />
70 HPS 91 Clear, ED17, Med Base 6,300 24,000 S62 -40C HX-HPF 120<br />
208<br />
0.81<br />
0.47<br />
1.45<br />
0.85<br />
0.75<br />
0.45<br />
6<br />
4<br />
240 0.4 0.75 0.37 3<br />
277 0.35 0.65 0.35 3<br />
347 0.3 0.55 0.3 2<br />
480 0.21 0.36 0.21 2<br />
100 HPS 130 Clear, ED17, Med Base 9,500 24,000 S54 -40C HX-HPF 120 1.15 2.20 1.30 7<br />
208 0.67 1.25 0.75 5<br />
240 0.58 1.10 0.65 3<br />
277 0.50 0.85 0.60 3<br />
347 0.39 0.70 0.45 3<br />
480 0.22 0.34 0.21 3<br />
150 HPS 188 Clear, ED17, Med Base 16,000 24,000 S55 -40C HX-HPF 120 1.65 2.80 2.00 10<br />
208 0.95 1.60 1.15 5<br />
240 0.83 1.40 1.00 5<br />
277 0.72 1.25 0.85 4<br />
347 0.56 0.92 0.52 3<br />
480 0.42 0.70 0.50 2<br />
250 HPS 295 Clear, E18, Mogul Base 29,000 24,000 S50 -40C CWA 120 2.50 1.70 1.65 7<br />
208 1.50 1.00 0.95 4<br />
240 1.30 0.85 0.80 4<br />
277 1.10 0.75 0.70 3<br />
347 0.93 0.70 0.60 2<br />
480 0.63 0.45 0.40 2<br />
400 HPS 464 Clear, E18, Mogul Base 51,000 24,000 S51 -40C CWA 120 3.80 2.00 3.30 10<br />
208 2.20 1.20 1.80 6<br />
240 1.90 0.95 1.50 5<br />
277 1.70 0.85 1.40 5<br />
347 1.32 0.70 1.00 5<br />
480 0.97 0.55 0.75 3<br />
COMPACT FLUORESCENT<br />
42 PL 46 Coated, GX24q-4 Base 3,200 12,000 N/A -18C Electronic 120 - - 0.39 2<br />
208 - - 0.23 2<br />
240 - - 0.20 2<br />
277 - - 0.17 2<br />
57 PL 59 Coated, GX24q-5 Base 4,300 12,000 N/A -10C Electronic 120 - - 0.80 2<br />
208 - - 0.40 2<br />
240 - - 0.27 2<br />
277 - - 0.21 2<br />
INDUCTION FLUORESCENT<br />
Max. Fuse Amps.<br />
100 IF 120 - - 0.88 3<br />
208 - - 0.66 2<br />
240 - - 0.37 2<br />
277 - - 0.29 2<br />
150 IF 120 - - 1.34 4<br />
208 - - 1.28 4<br />
240 - - 0.58 2<br />
277 - - 0.54 2<br />
All Initial Lumen values shown are approximate and may vary from one manufacturer to another. Consult lamp manufacturer’s data for exact lumen and life data.<br />
WARNING: All fixtures must be grounded in accordance with local codes or the National Electrical Code. Failure to do so may result in serious personal injury.<br />
Lamps by others.<br />
ANSI<br />
Code<br />
Starting<br />
Temp<br />
Circuit<br />
Type<br />
Voltage<br />
Operating<br />
Amps.<br />
Open<br />
Circuit<br />
Amps.<br />
Starting<br />
Amps.<br />
Min. Fuse<br />
Amps.<br />
KIM LIGHTING 21
TM<br />
www.kimlighting.com<br />
Because of a continuing product<br />
improvement program,<br />
<strong>Kim</strong> <strong>Lighting</strong> reserves the<br />
right to change<br />
specifications without notice.<br />
How may we serve you better?<br />
Let us know by visiting our web site<br />
at: www.kimlighting.com<br />
Hubbell<br />
<strong>Lighting</strong>, Inc.