Guida Tecnica Technical Guide Ratings Book Potenze
Guida Tecnica Technical Guide Ratings Book Potenze
Guida Tecnica Technical Guide Ratings Book Potenze
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
50 Hz 4 Pole 1 Phase<br />
Voltage 240/230 /220-120/115/110 DEDICATED WINDING<br />
RPM 1500<br />
Insulation Class H<br />
220/230/240 Volts 230V 220/230/240 Volts 230V<br />
Weight kW @ 1.0 PF 1.0 pf kVA @ 0.8 PF 0.8 pf<br />
MODEL (kg) LEADS AVR 150/40 125/40 105/40 Eff % 150/40 125/40 105/40 Eff %<br />
ECO3-1SN/4 63 4 SR7/2 4.9 4.8 4.4 75.4 4.4 4.3 4 73.4<br />
ECO3-2SN/4 70 4 SR7/2 6.1 5.9 5.5 77.4 5.6 5.4 5 75.4<br />
ECO3-1LN/4 82 4 SR7/2 8.4 8.1 7.3 78.9 7.4 7.2 6.6 76.9<br />
ECO3-2LN/4 91.5 4 SR7/2 10 9.7 9 79.4 8.9 8.6 8 77.4<br />
ECO3-3LN/4 96 4 SR7/2 11.3 11 9.8 79.6 10 9.7 8.9 77.6<br />
ECO28-SN/4 107 4 SR7/2 12.7 12.4 11.6 81.1 11.6 11.3 10.6 79.1<br />
ECO28-1LN/4 122 4 SR7/2 14.9 14.6 13.3 81.4 13.3 13 11.9 79.4<br />
ECO28-2LN/4 139 4 SR7/2 18.3 18 16.3 82.1 16.4 16.2 14.8 80.1<br />
ECO28-VL/4 165 4 SR7/2 21.1 20.5 18.4 82.6 18.9 18.4 16.2 80.6<br />
ECO32-2S/4 199 4 SR7/2 27 26 24 82.7 24 23 22 80.7<br />
ECO32-3S/4 214 4 SR7/2 31 29 27 83.4 27 26 25 81.4<br />
ECO32-1L/4 248 4 SR7/2 38 36 35 84.0 34 32 31 82.0<br />
ECO32-2L/4 282 4 SR7/2 45 43 41 84.7 41 39 37 82.7<br />
ECO32-3L/4 298 4 SR7/2 52 49 45 84.8 46 44 41 82.8<br />
ECP34-1S/4 341 4 DSR 61 58 53 84.8 55 52 46 82.8<br />
ECP34-2S/4 419 4 DSR 74 70 64 86.2 66 63 56 84.2<br />
ECP34-1L/4 445 4 DSR 85 81 73 87.2 76 72 65 85.2<br />
ECP34-2L/4 491 4 DSR 93 89 80 88.1 83 80 72 86.1<br />
ECO38-1SN/4 510 4 DSR 124 119 110 86.0 116 112 105 84.0<br />
ECO38-2SN/4 560 4 DSR 136 130 119 86.6 130 124 113 84.6<br />
ECO38-3SN/4 590 4 DSR 150 143 132 86.9 142 135 124 84.9<br />
ECO38-1LN/4 680 4 DSR 173 165 153 87.4 165 158 147 85.4<br />
ECO38-2LN/4 765 4 DSR 203 194 178 87.8 187 179 164 85.8<br />
ECO38-3LN/4 905 4 DSR 234 229 210 87.5 221 216 198 85.5<br />
ECO40-1S/4 1040 4 DSR 276 265 245 87.5 253 243 225 85.5<br />
ECO40-2S/4 1118 4 DSR 308 296 270 87.6 284 273 248 85.6<br />
ECO40-3S/4 1171 4 DSR 340 327 295 87.7 316 304 273 85.7<br />
ECO40-1L/4 1324 4 DSR 375 360 327 87.9 348 334 304 85.9<br />
ECO40-1.5L/4 1380 4 DSR 423 406 366 88.0 392 376 340 86.0<br />
ECO40-2L/4 1586 4 DSR 464 445 413 88.0 430 413 382 86.0<br />
ECO40-VL/4 1693 4 DSR 491 471 432 88.1 455 437 401 86.1<br />
All machines have an auxiliary winding 'standard' ‘standard’ with with 300% 300% short short circuit circuit capability.<br />
Zigzag, Delta, and Double Delta single phase connections available.<br />
Consult Factory to choose for your application.<br />
Consult Factory to choose for your application.<br />
Indicated voltage references to series or parallel star connection. Consult factory on voltages available<br />
for ECO 40, ECO 43 and ECO 46 as for some machine the series/parallel connection may result in a different<br />
voltage output<br />
<strong>Technical</strong> <strong>Guide</strong>: <strong>Ratings</strong> <strong>Book</strong> 7