CRIST INSTRUMENT COMPANY, INC.<br />

PROFILE<br />

<strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>mpany, Inc. started as a service to researchers who had specific apparatus requirements<br />

but could not find the appropriate equipment to meet their exacting needs or were just not completely satisfied<br />

with the items that were available. Because of the unique problem solving ability of the founding members of<br />

<strong>Crist</strong> <strong>Instrument</strong>, scientists began to seek their service and advice. This design service provided solutions to<br />

research problems and proved to be very helpful over the years.<br />

Demand for our advice as well as requests to design, modify and fabricate this type of research equipment<br />

continued to grow. In 1990, it was determined that to continue to be a part of the leading edge of medical<br />

research, the firm would have to expand. <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>mpany, Inc. was born.<br />

Through in depth discussions, <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>mpany, Inc. has provided ideas for the development of new<br />

device and the modification of existing devices to enable researchers the world over to follow their desired<br />

line of research. The result is many types of “state of the art” apparatus and equipment that assist continuing<br />

medical research.<br />

As a corporation, we feel that our primary mission is to provide products with excellent quality, to design and<br />

modify mechanical apparatus and suggest new uses for devices already available. We will also continue to<br />

add apparatus to our list of equipment that we have found to be valuable in the research field. It is our<br />

pleasure to provide you with products that assist your work, from a single small item to a complete onsite<br />

laboratory installation with a variety of mechanical and now electronic apparatus and equipment to aid the<br />

ever-growing research community.<br />

We look forward to continuing our assistance to the leading edge of medical research and providing you with<br />

consultation, design assistance and the manufacture of the tools you’ll need to get the most from your<br />

research.<br />

1<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


<strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>., Inc.<br />

Serving the Biomedical research Industry Since 1985<br />

<strong>Co</strong>nsulting, Custom design of mechanical apparatus<br />

Production of R&D <strong>Instrument</strong>ation<br />

TERMS OF SALE & POLICIES<br />

Domestic and International Terms of Sale & Policies are as follows:<br />

Hours of Operation: We are available by telephone between 7:00 a.m. and 4:00 p.m. US Eastern Time, however if your normal<br />

business hours conflict due to time zone differences, a special appointment can be arranged. You can also contact us by FAX and E-<br />

Mail 24 hours a day. Our engineering, production, and Sales Departments are available to discuss aspects of your order or our<br />

products.<br />

Quotation Prices: The quoted prices for items of your inquiry are guaranteed for 60 days. After 60 days the price is subject to<br />

change; however, we do make every effort to hold quotes firm as long as possible. Upon receipt of your order, prices are firm until<br />

filled. Rush orders can be made for standard off-the-shelf products (in stock only); and will be shipped with-in 24 hours of the receipt<br />

of the Purchase Order. Discounts are available for larger volumes. All products manufactured by <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>mpany, Inc. are<br />

made in the U.S.A. unless otherwise noted.<br />

Purchase Orders: The preferred method for ordering products and/or customized apparatus is via a Purchase Authorization from<br />

your purchasing agent or via credit card. Credit card purchases require the cardholders’ information as directed by federal and<br />

banking regulations. Credit Card orders will not be charged until shipped unless otherwise advised. A copy of the shipping invoice<br />

will be sent to the end user or the purchasing authority at the cardholder’s address. Payment in advance is acceptable in lieu of<br />

Purchase Orders. If your organization is tax or import duty exempt, please provide documentation at the time of the order. This will<br />

facilitate the transfer of your goods through customs.<br />

Terms for Payment: Terms are net 30 from the date of the Invoice for established accounts and an Invoice will be sent via Fax, e-<br />

mail or Postal Service to the responsible paying party. Payment may be arranged in several ways. Please advise which method will<br />

be best for you at time of placing your order. Payment options include: 1) Direct payment by Wire Transfer. We will supply banking<br />

information on request. 2) A check drawn on a corresponding bank in US Dollars. 3) Payment through Visa or Master Card. 4)<br />

Letter of Credit. Payments are only accepted in US Dollars unless prior arrangements are made. Finance charges are levied on<br />

balances not received within 45 days of the Invoice date at a rate of 1.5% per month. Also, payments received 45 days after the date<br />

of the invoice will affect any discounts to which your organization may be entitled including future purchases.<br />

Event of Default: If payment is not forthcoming within 90 days of the date of the Invoice it will be considered in default of the<br />

Agreement. <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>. shall have the right to exercise all remedies available to it under the applicable laws of the State of<br />

Maryland. Which include but are not limited to the entitlement to obtain, at the expense of the Purchaser any record searches, reports<br />

and legal and other opinions and advice as may be deemed necessary to collect this obligation. The Purchasing organization agrees to<br />

pay all costs, fees, and expenses in connection with the preparation, execution and any and all other costs, fees and expenses incurred<br />

by, or on behalf of <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>., Inc. without limitation, including attorneys’ fees and expenses, and Enforcement <strong>Co</strong>sts.<br />

Ownership of Design and Related Documents: All drawings; specifications; magnetic or electronic media, including without<br />

limitation, software; calculations; and other information gained, resulting from your purchase of custom items which are designed by<br />

<strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>mpany, Inc., shall remain the property of <strong>Crist</strong> <strong>Instrument</strong>, unless such materials are included in the Purchase<br />

Order as a separate line item. All design work as defined above is not subject to use by others without the express written permission<br />

of <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>mpany, Inc. All materials as described above containing proprietary information shall be returned to <strong>Crist</strong><br />

<strong>Instrument</strong> <strong>Co</strong>mpany, Inc. at the Buyer's expense.<br />

Returns: We make every effort to prevent customers from receiving goods that may be contaminated or cross-contaminated. <strong>Crist</strong><br />

<strong>Instrument</strong> <strong>Co</strong>mpany, Inc. will accept returns only under the following conditions:<br />

1) Products that have been in direct contact with animals or may have been in contact with animals cannot be returned.<br />

2<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


2) Products that are acceptable for return will be charged a 25% restocking fee, with the exception of returns for modifications or<br />

repair.<br />

3) Products being returned for any reason, including modification or repair require an RMA #. Products being returned for repair or<br />

modification that have been in contact with animals must be thoroughly cleaned prior to shipping. If they are not cleaned before we<br />

receive them, they will be returned at your expense and will be subject to additional shipping and handling fees.<br />

Warranties: <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>., Inc. warrants, to the original end user only, that our products substantially conform to the<br />

specifications as designed and are substantially free from defects in material and workmanship. Provided that <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>.,<br />

Inc. is notified of defects within the warranty period (set forth below) and in accordance with paragraphs as detailed below, we will<br />

correct all defects in materials and/or workmanship. The warranty begins from the date of product delivery with respect to the<br />

products as listed below:<br />

Section 1 -<br />

Primate Chair bodies and attached accessories to the body only, six months. This warranty will be voided if plastic parts are<br />

cleaned with non-compatible solutions and/or if this product is subjected to harsh treatment in a cage washer.<br />

Chair Bases and Trolleys are warranted for a period of one year.<br />

Section 2 -<br />

Poles and collars are warranted for a period of one year.<br />

Section 3 -<br />

Recording Microsyringes, Multi-electrodes are warranted for a period of 30 days.<br />

Miniature Microdrives are warranted for a period of 90 days.<br />

Section 4 -<br />

Touch Panel Sensors are warranted for a period of 6 months.<br />

<strong>Co</strong>mmutators are warranted for a period of 1 year.<br />

Section 5 -<br />

Reward Systems are warranted for a period of 6 months except for Solenoids.<br />

Solenoids located on the Dispenser Unit are warranted for period of 3 months due to material failure UNLESS this item<br />

shows evidence of overheating as a result of customer failure by leaving this product turned to the Drain Setting. Warranty<br />

also does not extend to failure due to pulp clogs.<br />

Section 6 –<br />

Metal devices are warranted for a period of one year for defects in materials or workmanship only.<br />

Plastic devices are warranted for a period of 90 days. Warranty is voided if temperatures exceed manufacturers’<br />

recommendation for the particular type of plastic or if during application the product is subject to excessively rapid heating<br />

and cooling.<br />

Section 7 -<br />

Search <strong>Co</strong>ils, Tangent Screens and optical devices manufactured by <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>., Inc. are warranted for a period of<br />

one year.<br />

Eye Tracking <strong>Co</strong>ntrollers are warranted by the manufacturer for a period of one year.<br />

Section 8 -<br />

Laminated products are warranted for a period of one year. Warranty may be voided if product is subjected to high-pressure<br />

steam or high-pressure water or harsh chemicals for cleaning.<br />

Section 9 -<br />

Stereotaxic Frames are warranted for a period of one year.<br />

If the purchaser discovers within the warranty period as described a warranted defect for the product in question, the purchaser must<br />

notify <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>., Inc. The purchaser will receive instructions regarding procedures to follow regarding return and/or<br />

replacement of the product in question. All repairs will be performed at <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>., Inc. facility in Hagerstown, Maryland<br />

unless otherwise advised.<br />

<strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>., Inc. does not warrant any products, components or parts not manufactured by <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>., Inc., defects<br />

caused by the purchaser's failure to provide a suitable installation environment for the product, damage caused by the use of the<br />

product for purposes other than those for which it was designed, damage caused by disasters such as fire, flood, wind or lightening<br />

unless and to the extent that the product specification provides for a resistance to a defined disaster, or acts of vandalism or terrorism,<br />

damage caused by unauthorized modifications or attachments, or any misuse by the purchaser.<br />

Termination: Notwithstanding any contrary terms contained above, the Buyer shall have the right at their discretion, five (5) days<br />

following the Buyer's written notice to <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>mpany, Inc. to cancel in whole or part, the Buyer's order or any contract<br />

resulting from its acceptance. In the event of such a cancellation, the Buyer will be obligated to pay for any costs, which have been<br />

incurred by <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>mpany, Inc. prior to the date of termination, plus a normally accepted trade allowance on such costs as<br />

3<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


full payment of overhead and profit, provided. However, in no event shall the Buyer be obligated to pay an amount in excess of the<br />

amount set out in the Buyer's order for the items or services being canceled.<br />

Shipping Procedures: Small orders are shipped UPS (United Parcel Service) or Federal Express unless specified otherwise. Large<br />

Orders such as large laboratory set-ups are shipped airfreight by the most cost effective shipper available at the time. If your<br />

Organization has a shipper or broker of preference, we will use your shipper. The cost of shipping including insurance will be added<br />

to your order. Charges for duties and other expenses (brokerage fees or value added taxes) are the responsibility of the Buyer*. Wire<br />

Transfer charges levied by your bank are the Buyers Responsibility. Shipping charges are usually prepaid and added to your order<br />

unless we are directed otherwise and other arrangements are made to cover these expenses, when the Order is placed.<br />

*INTERNATIONAL CUSTOMERS: At the time of your order please provide <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>mpany, Inc. with any of the<br />

following information:<br />

1. V.A.T. Exemption Certificates<br />

2. Broker Information<br />

We realize that the products our clients order are often needed on a time limited basis and this information will help speed your<br />

shipment through Customs.<br />

Thank you for your cooperation and for using <strong>Crist</strong> <strong>Instrument</strong>s and Apparatus<br />

Sincerely,<br />

J.M. Burkholder<br />

<strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>mpany, Inc.<br />

4<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


<strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>mpany is Located in Time Zone 5. Our Hours are: 7:00 AM to 4:00 PM.<br />

If you would like to speak to a representative, but your hour’s conflict with ours, please<br />

contact us and we will make an appointment to talk with you.<br />

5<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


<strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>., Inc.<br />

<strong>Co</strong>mpany Founders<br />

Joan M. Burkholder – C.E.O., <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>., Inc.<br />

Joan began her professional career at the age of eight. She often worked in her great aunt’s health<br />

food store, where she stocked shelves, worked as a cashier, and performed other tasks crucial to the business.<br />

By the time she was sixteen, she was managing the store and serving all business functions in her great aunt’s<br />

absence. Joan was also involved with her father’s business. He was a residential construction contractor, and<br />

Joan would often assist him with his work.<br />

Joan became involved with the National Institutes of Health (NIH) in Bethesda, MD in 1961. She<br />

started work in the shop area, scheduling the construction and maintenance work for all NIH facilities. At the<br />

time, all construction and maintenance for NIH was done “in house” – none being contracted out. During this<br />

time, she was active in developing procedures and charts for controlling this operation. After she left NIH,<br />

many of her systems continued to be used by her successors.<br />

Next, she transferred to the Security and Safety Division. As an administrator of this division, she was<br />

instrumental in developing training programs for the Locksmith Shop. She also worked closely with the Training Office<br />

in developing the <strong>Co</strong>nversion Program. This program was designed to provide guards with the opportunity to become<br />

U.S. Police officers. Joan also developed budgets and hiring programs for the Locksmith, Security, Police, and Fire<br />

Departments.<br />

Subsequent to leaving NIH, Joan worked as an administrator for the Department of Housing and<br />

Urban Development (DHUD). There, she was very active in upgrading working conditions at the Baltimore<br />

office. While staying under budget, she organized the Baltimore office’s move to a new facility.<br />

After ending her work for the government, Joan began to work as a consultant for several companies<br />

in the D.C. – Baltimore area where she provided operations improvements, orchestrated company moves to<br />

new locations, etc. She soon teamed up with Charles <strong>Crist</strong> to start <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>., Inc.<br />

While holding these noteworthy positions, Joan also managed to continue her education and raise a<br />

family. Joan earned a B.S., having majored in Business Administration and minored in both Chemistry and<br />

Architecture. She has also raised five children.<br />

Charles F. <strong>Crist</strong> – Executive Vice President, <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>., Inc.<br />

6<br />

Charles (Chuck) <strong>Crist</strong> started his career as an electrician installing lighting in<br />

homes and in gas stations.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

In 1956 he received a commission by the Navy<br />

Department and was accepted in their Apprenticeship Training Program with the<br />

intent of becoming a Master Electrician. As there were no openings in that area he<br />

PDF created with pdfFactory trial version www.pdffactory.com


accepted a training position as a Machinist temporarily. During his training he<br />

worked on a variety of armaments like the 16-inch battleship guns, the Gatling gun<br />

and the 30mm cannon. In 1960 he graduated at the top of his class with two years of<br />

college as a Journeyman Machinist. That same year he transferred to the National<br />

Institutes of Health.<br />

He began his work in the biomedical field at NIH in Bethesda, MD with the Arthritis<br />

Institute in the Laboratory of Physical Biology. During Chuck’s 22-year tenure with<br />

this group he worked with many experts in a broad range of disciplines. Drawing on<br />

his knowledge acquired from his earlier training in mechanical principles and<br />

machine shop knowledge he was able to create equipment and apparatus to augment<br />

the research in this group. Working on a one-to-one basis he developed a thorough<br />

understanding of the type of data his scientists wished to collect as well as the proper<br />

form and format. His designs and fabrications required him to draw upon his broad<br />

knowledge of electrical, electronics, hydraulics, materials characteristics, i.e.<br />

chemical resistances, strengths, flexibility and life.<br />

Among the many devices he developed, some were used for studies of fireflies. The<br />

‘Borneo Bug Gun’, which was designed by Chuck, recorded the synchronized<br />

flashing of fireflies. It was used in some of Dr. John Buck’s studies of synchrony.<br />

Chuck also did work with fluid surface tension measurement and molecular modeling<br />

and built one of the early hemoglobin models for Dr. Muriyama.<br />

While at the Arthritis Institute, Chuck developed important apparatus and<br />

equipment for muscle-related research. He developed a system for studying<br />

simultaneous x-ray and laser diffraction patterns from the same sarcomere of a single<br />

muscle fiber. This system provided for the electrical stimulation of the muscle while<br />

the reaction pattern was measured and recorded, it enabled researchers to measure<br />

both the force and distance traveled by the contraction. Chuck also developed the<br />

system in which the muscle was kept alive in a re-oxygenated saline bath. This<br />

allowed the muscle to be cycled approximately 100 times per 24-hour period.<br />

Chuck was also responsible for the design and creation of several other useful<br />

instruments while at the Arthritis Institute. Chuck’s design of a cold finger for the<br />

7<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Raman Spectrophotometer facilitated the crystallization of gaseous elements. He<br />

created a complex mirror-bending device for use with a spray of <strong>Co</strong>pper K-alpha x-<br />

rays from a GX 13 Generator. This device allowed for very fine focusing at very<br />

high intensities. Additionally, he designed many tools for use with electron<br />

microscopes and constructed a number of models based on electron micrographs.<br />

Chuck transferred from the Arthritis Institute to the Eye Institute of NIH<br />

where he worked as their Biomedical Engineer. He worked with Dr. Robert Wurtz in<br />

the Laboratory of Sensory Motor Research and other senior scientists in the lab.<br />

While Chuck was there, it became necessary for the facility to create ten new<br />

research labs. Time was of the essence, as all ten labs had to be installed very<br />

quickly to allow incoming postdoctoral students to work with the senior scientists.<br />

Modified electronic racks had to be installed. Existing cables had to be wired to<br />

equipment. Eye coil systems had to be built and hooked up, and a hoisting system<br />

for the coil frames had to be manufactured. Primate chairs that would be universal to<br />

all of the labs and an accompanying positioning system for the chairs had to be<br />

developed. As the designer, builder and installer Chuck dealt directly with all of the<br />

issues as they related uniquely to the setup of each of the ten new labs.<br />

Because Chuck also personally designed and manufactured unique<br />

equipment to meet the particular needs of each of the individual labs when they were<br />

being initially installed, he was repeatedly called upon when new researchers and<br />

changing research dictated modifications and replacements of equipment. The many<br />

years spent periodically renovating these labs – designing and manufacturing<br />

specialized, custom-built equipment gave him a unique insight into the needs of<br />

researchers in this field.<br />

While working with Dr. Wurtz in Building 10 at NIH, Chuck developed<br />

many important devices at the NIH facilities. He worked on the Rear Projection<br />

Screen and co-authored a paper with David Lee on the results of the device. He<br />

developed the process of using Denril drafting paper with an acrylic base for creating<br />

brighter and sharper imaging. Chuck developed the syringe that simultaneously<br />

recorded and injected material to create a lesion without extracting or moving the<br />

electrode. He was also involved in the creation of mirror scanning devices that used<br />

8<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


LED or laser light sources as well as general scanning motors and controllers to<br />

move and position the device’s fixation point. Chuck developed the grid system for<br />

precise mapping of the brain and adapters to use this system with a variety of<br />

microdrives. He developed the knurled base on the Evarts Style chamber, later<br />

adding the pin to help accurately position the grid and grid adapters repeatedly in the<br />

same position. He created a trapeze system to support large screens and allow for<br />

precise adjustment. Chuck developed microdrives for use with specialized chambers<br />

and adapters. He has also been very active in the on-going development and<br />

adaptation of the basic primate chair.<br />

After many years at NIH, Chuck retired in 1992. He has since focused on<br />

work at <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>., Inc. where he had already been intimately involved in<br />

product engineering since the company’s creation in 1990. He is also proud of the<br />

fact that three of his five children are employed in the company as well.<br />

P.S. He is still waiting for that transfer for training in the electrical trade.<br />

9<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Section 1 – Primate Chairs<br />

1-Primate chairs<br />

Primate chairs from <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>., Inc. are<br />

designed to enable researchers to restrain primates effectively<br />

in a wide variety of research scenarios. Our chairs may be<br />

used in protocols ranging from standard vision studies to<br />

complex behavioral experiments. The numerous available<br />

styles and options, in combination with custom design<br />

options, allow our chairs to fit the protocols set forth by the<br />

researcher, rather than force researchers to design their<br />

protocols according to standard features of the chair.<br />

Our standard models come equipped with a variety of<br />

features. Most of our chairs are made from polycarbonate, a<br />

plastic that is stronger than acrylic yet transparent to permit<br />

easy viewing of the subject in the chair. <strong>Co</strong>rners are<br />

reinforced with aluminum for extra strength. The main body<br />

of the chair, which holds the subject, is ventilated and permits<br />

movement of arms and legs, reducing muscle atrophy and<br />

discomfort. The two-part neck plate restrictors adjust to<br />

allow the chair to fit different primates. Trolley and base<br />

wheels have a locking swivel castor design for increased<br />

stability.<br />

All models include the following features:<br />

· All edges are rounded or de-burred; there are no<br />

sharp edges on any part of the chair.<br />

· A removable waste tray and drip lip are included. The<br />

drip lip is located above the waste tray to direct any<br />

waste towards the waste tray. With this waste<br />

containment system, AAALAC has been known to<br />

waive some of the requirements for research room<br />

sanitation.<br />

· A safety restraint chain is included.<br />

· A perch for the primate is adjustable (up and down)<br />

for the comfort of the subject. On most models, this<br />

is made from stainless steel and aluminum.<br />

· All chairs of any size that are ordered with a tall base<br />

will have the eye height set to 47-48 inches unless<br />

specified otherwise.<br />

Upon special request, all of our chair designs can be<br />

modified to meet your specific protocol. If these chairs do<br />

not meet your requirements, see the chair option sections for<br />

additional available chair options. If you require<br />

specifications that are not listed, please call your <strong>Crist</strong><br />

<strong>Instrument</strong> <strong>Co</strong>mpany sales representative, and they will be<br />

happy to assist you.<br />

Primate chairs,<br />

Transport trolleys and<br />

Positioners<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


PRODUCT INFORMATION<br />

The basic descriptions below should get you started with your chair selection. While some of the features are<br />

automatically included (e.g. perch bars), you can select other options to customize your chair(s) to fit your research<br />

program. Our chairs are available in the sizes listed below.<br />

1-CC<br />

Standard Primate Chair Models<br />

The standard size is the chair size most frequently ordered. It accommodates primates that weigh up to 9 kilograms. The<br />

primate compartment measures 10” x 10” x 23” (25.40cm x 25.40cm x 58.42cm).<br />

Catalog numbers beginning with 1-CCP indicates that the chair front panels are either plain or include a touch bar<br />

handle. Catalog numbers beginning with 1-CCC indicates that the chairs have small removable front panels.<br />

These panels can be modified to hold touch bars, joysticks, or other tasking devices.<br />

1-CM<br />

Mini Primate Chair Models<br />

This model accommodates small primates, the size of squirrel monkeys. The compartment size is 6” x 6.5” x 8.5”<br />

(15.24cm x 16.51cm x 21.59cm). 8.5” (21.59cm) is the maximum height to the shoulder. The rear door includes a<br />

small cutaway area to accommodate a stiff tail.<br />

1-CS<br />

Small Primate Chair Models<br />

This model accommodates primates ranging in size from the squirrel monkey to the macaque. The compartment size is<br />

8” x 8” x 21” (20.32cm x 20.32cm x 53.34cm). This is an excellent size for small Macaques.<br />

1-CL<br />

Large Primate Chair Models<br />

The large chair was designed for primates weighing up to 18 kilograms. The primate compartment is the same basic<br />

design as the standard model, only larger. It measures 12” x 12” x 25” (30.48cm x 30.48cm x 63.50cm).<br />

SPECIFICATIONS<br />

MATERIAL:<br />

Our standard chairs are constructed with polycarbonate material, which is more impact and heat resistant than<br />

acrylic (Plexiglas). Because it can withstand more heat and abuse than acrylic, it has a more extended useful life. The<br />

chairs should be hand washed and sanitized with a mild disinfectant and hot water, the temperature of which should not<br />

exceed 190 degrees. You may add a few drops of bleach to the wash water, then rise thoroughly with pure water. Do<br />

not use alcohol, ketone solvents or other alkaline cleaners. Use of a cage washer is not recommended because rapid<br />

heating and cooling in combination with high-pressure water jets is known to increase the likelihood of fatigue cracks.<br />

CONSTRUCTION:<br />

Our chairs come with many predrilled holes. These holes provide bolt on convenience for many of our popular<br />

options e.g., handles and coil support wings. Your chair may also have an optional door latch position. The position of<br />

the latch is determined by the options you have chosen. For example, if you ordered coil support wings, the latch will be<br />

in the lower position so that the metal latch is not inside the coil field. You may move your latch or add a second<br />

without affecting your warranty. The brass secondary restraint chain at the top of the hinged side of the chair is an<br />

AALAC safety requirement. All sharp edges that may come into contact with the animal and researcher have been<br />

rounded for comfort and safety.<br />

All of our chair parts are individually replaceable. If they should become damaged or if you require changes to<br />

accommodate your investigations, the part you wish to change can be removed and/or replaced. Individual chair parts,<br />

both standard and modified, are available. Please feel free to call or email us for any information on the parts you need.<br />

Our chair department manager and sales staff is always ready to help.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Vision Studies Primate Chair<br />

This chair has many options that are included in the basic price. The<br />

main feature of the Vision Model Chair (1-CCP) is a touch bar mounted on<br />

the front of the chair. When connected to the Touch Sensor Module (4-TPS-<br />

E1) with banana plugs and touched by the monkey, it completes a circuit that<br />

passes through the perch and the Module, sending a 5-volt TTL signal to a<br />

personal computer or touch sensor that can trigger a reward from any of our<br />

reward systems. The Touch Sensor Module and reward systems are sold<br />

separately<br />

The Standard Perch Assembly is included in this chair (1-CC-7).<br />

Assembled with machined stainless steel rods, mounted horizontally in an<br />

aluminum frame, it is a comfortable surface for the monkey to sit or crouch.<br />

The door and the waste tray (a standard feature of all of our chairs)<br />

open in the rear. The door is mounted with stainless steel spring piano type<br />

hinges and held with a stainless steel spring latch that can accommodate an<br />

optional locking mechanism. A drip lip is incorporated into the design just<br />

above the Waste Tray to prevent leakage to the outside of the chair.<br />

The corners of the chair front are reinforced with custom extruded<br />

aluminum. The chair side panels are pre-drilled for optional waist restraint or<br />

external handles. The pre-drilled holes can also accommodate optional<br />

wings, which are designed support to either the 15-inch or the 18-inch coil<br />

frame. <strong>Co</strong>il Support Wings are an option available at no extra cost on this<br />

model. They are convenient for pushing the chair when it is mounted on a<br />

base.<br />

The neck plate system has a fixed front plate and a removable rear<br />

neck plate fastened in place with two knobs, which can be turned by hand or<br />

with an Allen wrench. All neck plate systems are designed not to choke the<br />

subject.<br />

Additional options included at no extra cost with this model are the<br />

Top Plate Head Positioning System (1-CC-9 and 1-CC-10), the Safety<br />

Restraint Chain (1-CC-14), and the Tall Base (V50). The Top Plate is<br />

supported by the Side Head Plates. These units are 1-inch thick<br />

Polycarbonate. The Top Plate has a center slot running from the front to the<br />

back to accommodate a head restraint unit. The Safety Restraint Chain has<br />

snap hook ends and is a requirement (per AAALAC standards). This chain is<br />

designed to restrain the monkey while loading and unloading in the event of<br />

an escape the subject is still attached to the chair It attaches to the collar. <strong>Co</strong>llars are<br />

sold separately.<br />

An interesting variation of the Vision Model Chair is the Removable Front<br />

Fig. 1.1 Vision Studies Primate Chair<br />

with Tall Base<br />

Panel Model (1-CCC). On this model, a touch bar is mounted on a removable front panel. The removable panel can be replaced<br />

with a variety of tasking devices (e.g., the Touch Bar or a Joy Stick). In addition, this model features the Top Bar Restraint System<br />

(910B). With this system, side head supports allow the attachment of a top bar in one of five anterior/posterior positions. The top<br />

bar then allows the lateral positioning of other head restraint devices. This model is also available with a Low Trolley Base (V60).<br />

VISION STUDIES CHAIR OPTIONS:<br />

Options available for these Chair Models are outlined below (you may use these catalog numbers when ordering or<br />

inquiring regarding your research needs):<br />

1-CCC<br />

Removable Touch Bar Plate<br />

This removable panel mounts on the front of your chair. If you require a chair with this option, your chair’s catalog<br />

number will begin with 1-CCC, rather than 1-CCP.<br />

<strong>Co</strong>ntinued next page<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


1-CC-910B<br />

Top Bar Head Positioning System<br />

This replaces the top plate system and permits forward/backward and lateral adjustments of head position. If you require<br />

a chair with this option, your chair’s catalog number will be (1-CCP-910 to 1-CCP-910B) or (1-CCC-910 to 1-CCC-<br />

910B).<br />

1-CCA-93S<br />

Audio Chair Type Head Holding Post<br />

This type of positioner is standard on the Audio Chair, but it is an addition to the above models. It replaces the top bar or<br />

the top plate systems. For this option replace the catalog number (910 or 910B) with (93S).<br />

1-CC-52<br />

Neck Plate System<br />

This is to be used in conjunction with a collar from Primate Products, Inc.<br />

1-CC-5F<br />

Self-Feeding Neck Plate System<br />

Special neck plates allow the subject to reach its mouth with its hand so as to allow for self-feeding and similar activities.<br />

Call for Product-# Neck Plate System with enlarged/reduced neck opening<br />

If you believe this to be something you require, please contact us for additional information and catalog numbers.<br />

1-CC-1-DBL and<br />

1-CC-1A-DBL<br />

Double Neck Plate Option<br />

This is an option that allows standard and large chairs to be used with smaller primates (right side: 1-CC-1-DBL) (left<br />

side: 1-CC-1A-DBL).<br />

1-CC-6C<br />

Removable Neck Plate<br />

This is a safety feature that allows for eight inches of extra clearance from the subject’s neck. (1-CC-6C)<br />

1-CC-5J<br />

Neck Plate w/ Anti-Rotation Head Blocks (Jaw Blocks)<br />

Dual jaw blocks on the neck plate prevent the subject from turning its head. These blocks are useful when experimental<br />

specifications make the use of a rigid head holding system infeasible.<br />

1-CC-19-4<br />

Waist Plate<br />

This is a “C”- shaped plate that is open in the rear and restricts movement, keeping the subject’s feet below its waist.<br />

1-CC-19-split-size # Waist Plate System (two piece)<br />

This feature consists of a fixed front plate and a removable rear plate. The rear plate half is applied after the monkey is<br />

in the chair. The rear plate half comes with a handle for easy application and removal. This waist plate system<br />

completely surrounds the subject’s waist, keeping the animal’s feet below its midsection. This feature is available in<br />

three waist diameter sizes: Small- 4” (10.16cm), Standard- 5” (12.71cm), and Large- 6” (15.25cm).<br />

1-CC-25<br />

Knee Separator<br />

This feature fits between the subject’s knees in order to separate them.<br />

1-CC-17<br />

Aluminum Slot Liners<br />

This feature consists of aluminum inserts, which are installed in the perch and neck plate slots. These liners reduce stress<br />

on the weaker plastic chair sides and can thereby extend the life of your chair.<br />

1-CC-30<br />

<strong>Co</strong>il Support Wings<br />

These are designed for the stabilization of the 15 and 18-inch coil frames (38.12cm and 45.74cm).<br />

1-CC-302<br />

<strong>Co</strong>il Support Wings, Large<br />

These are designed for coil frames of up to 22-inches (55.90 cm).<br />

1-CC-32<br />

Dutch Doors<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


These doors open to separate levels – one door to the upper level (above the waist plate) and one to the lower level<br />

(below the waist plate).<br />

1-CC-34<br />

Guillotine (Sliding Rear Door)<br />

This door opens vertically to allow the chair to be positioned directly against the cage. Included in the design is a system<br />

of hooks that engage the bars of the cage and prevent the chair from being pushed away. Chair height can be modified<br />

(upon request, during ordering) to match the cage door height.<br />

1-CC-71<br />

Seat<br />

This is a modified perch system that is designed to increase primate comfort in order facilitate subject cooperation during<br />

longer experiments. It also can be used as a booster seat, making it possible to use a standard chair with a smaller<br />

primate. This usually requires Extended Perch Slots (see below).<br />

1-V50 Standard Tall Base<br />

The frame is constructed of aluminum on 4 non-conductive 5” (12.70 cm) diameter-locking wheels. This base places the<br />

primates eye height at our standard level, between 47 and 48 inches (199.4 and 121.9 cm) from the floor level. There are<br />

several positioning systems available to fasten the chair in the testing area. To select the Tall Base option, add V50 to<br />

the end of your chair model number. Example: (1-CCC-910B-V50) Chair is pictured above.<br />

1-V60 Low Trolley Bases<br />

Low trolley bases are 6.50-inches (16.5 cm) tall and are mainly designed for transporting or use in one of our isolation<br />

chambers. When using in an isolation chamber some changes may be required, e.g. height will change the part number<br />

(see Bases and Trolley section). To select this model base add V60 to your selected chair model. Example (1-CCP-910-<br />

V60). When using a Low Trolley model base in conjunction with an isolation chamber, please also refer to Transport<br />

Trolleys section<br />

Call for Cat-#<br />

Canvas Chair <strong>Co</strong>ver<br />

Canvas chair covers are most useful for transporting the subject though sensitive areas. They are also useful for keeping<br />

the chair dust free though extended storage.<br />

Catalog Number Chair Size/Defining Option Primates to be used with<br />

1-CMP-910-V50 Mini New World<br />

1-CMC-910-V50<br />

w/ removable touch bar plate<br />

1-CSP-910-V50 Small 3 - 6 kg<br />

1-CSC-910-V50<br />

w/ removable touch bar plate<br />

1-CCP-910-V50 Standard 4-9 kg<br />

1-CCC-910-V50<br />

w/ removable touch bar plate<br />

1-CLP-910-V50 Large 8-18 kg<br />

1-CLC-910-V50<br />

w/ removable touch bar plate<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


TV Primate Chair:<br />

FOR TOUCH SENSITIVE TV SCREEN AND OTHER REACHING TASKS<br />

This is the primate chair of choice for protocols that require<br />

the subject to be able to perform manual tasks, such as reaching hands<br />

out of the chair to a touch panel television screen. A reversal of the<br />

front panel (1-CCT-21A) permits hand(s) to have excess to the outside<br />

of the chair through an opening. Additionally there is a safety barrier<br />

plate (1-CCT-21D) that provides protection while the front panel is<br />

being adjusted. Special locking pins hold the reversing panel in place<br />

during experiments. The front, non-removable neck plate is fixed to<br />

the chair, while the rear plate is adjustable from front to rear and comes<br />

with either two knobs (1-CC-5A) or two Allen Cap screws (1-CC-5B).<br />

(Please specify which of the two you prefer when ordering.)<br />

The subject enters and exits the chair from an air-vented,<br />

swinging door on the rear. The door is mounted with stainless steel<br />

piano type hinges and held with a stainless steel spring latch that has an<br />

optional locking mechanism.<br />

A waist plate similar to the design of the front neck plate is<br />

standard on the TV Primate Chair. This inhibits the monkey from<br />

extending its feet up and out the front of the chair. However, due to the<br />

adjustable aluminum and stainless steel perch, the primate is still able<br />

to flex and move its feet for comfort. The Waste Tray (1-CC-70) on<br />

the TV Chair is inserted from the rear. A restraint chain with snap<br />

hook ends is also included; as an AAALAC standard the purpose of<br />

this chain is to leash the monkey while loading and unloading to<br />

prevent the primate from escaping. The restraint chain is used with a<br />

collar that is sold separately.<br />

Fig. 1.2 TV Primate Chair with Tall Base<br />

For the purpose of holding the primate’s head the TV Chair<br />

comes with the choice of a Top Plate or a Top Bar. The Top Plate is 1<br />

inch (2.54cm) thick Polycarbonate and has a slot that runs front to back to allow adjustment of the head to a desired<br />

angle for viewing. Through the slot is a threaded bar that attaches to a head holding system. The Top Bar, an option to<br />

the Top Plate, has five available positions front to rear and allows unlimited adjustment side to side as well as posterior<br />

and anterior angles. This system also can operate with several different head holding devices.<br />

Chairs can be easily transported and elevated to a convenient working height when mounted to our Standard<br />

Tall Base (Optional), which is a frame constructed of aluminum on 4 non-conductive five-inch diameter lockable wheels.<br />

This base places the primates eye height at our standard height of between 47 and 48 inches (119.4-121.9 cm) from the<br />

floor level. A low trolley is also available. The low trolley is 6.50 inches (16.5cm) tall and is mainly designed for<br />

transporting the chair. The height of this trolley can be customized to match your Isolation chamber level or other<br />

equipment. This specific modification is available at no extra cost if you plan to use our Isolation Chambers. See the<br />

"Bases and Trolleys" and “Isolation Chamber” sections for additional details.<br />

TV CHAIR OPTIONS:<br />

1-CC-93S<br />

Audio Chair Type Head Holding Post<br />

Replaces the Top Bar or Top Plate system on other Chairs. This is usually attached to the sides of the chair instead of<br />

the Rear as on the Audio Chair. It can be put on the Rear above the door, but the monkey must duck under the mount to<br />

get into the chair. (See Audio Chair Description) (1-CC-93S)<br />

5-inch External Handles<br />

These handles are designed to make set-up and transportation of the chair easier.<br />

1-CC-5J<br />

Neck Plate w/ Anti-Rotation Head Blocks (Jaw Blocks)<br />

Dual jaw blocks on the neck plate prevent the subject from turning its head. These blocks are useful when experimental<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


specifications make the use of a rigid head holding system infeasible.<br />

1-CC-17<br />

Aluminum Slot Liners<br />

This feature consists of aluminum inserts, which are installed in the perch and neck plate slots. These liners reduce stress<br />

on the weaker plastic chair sides and can thereby extend the life of your chair.<br />

1-CC-30<br />

<strong>Co</strong>il Support Wings<br />

These are designed for the stabilization of the 15 and 18-inch coil frames (38.12cm and 45.74cm).<br />

1-CC-302<br />

<strong>Co</strong>il Support Wings, Large<br />

These are designed for coil frames of up to 22-inches (55.90 cm).<br />

1-CC-32<br />

Dutch Doors<br />

These doors open to separate levels – one door to the upper level (above the waist plate) and one to the lower level<br />

(below the waist plate).<br />

1-CC-19-SP-size # Waist Plate System (two piece)<br />

This feature consists of a fixed front plate half and a removable rear plate half. The rear plate half is applied after the<br />

monkey is in the chair. The rear plate half comes with a handle for easy application and removal. This waist plate<br />

system completely surrounds the subject’s waist, keeping the animal’s feet below its midsection. This feature is<br />

available in three waist diameter sizes: Small- 4” (10.16cm), Standard- 5” (12.71cm), Large- 6” (15.25cm).<br />

1-CC-52<br />

Neck Plate System<br />

This is to be used in conjunction with a collar from Primate Products.<br />

1-CC-5F<br />

Self-Feeding Neck Plate System<br />

Special neck plates allow the subject to reach its mouth with its hand so as to allow for self-feeding and similar activities.<br />

Neck Plate System with enlarged/reduced neck opening<br />

If you believe this to be something you require, please contact us for additional information and catalog numbers.<br />

1-CC-34<br />

Guillotine (Sliding Rear Door)<br />

This door opens vertically to allow the chair to be positioned directly against the cage. Included in the design is a system<br />

of hooks that engage the bars of the cage and prevent the chair from being pushed away. Chair height can be modified<br />

(upon request, during ordering) to match the cage door height.<br />

1-CC-71<br />

Seat<br />

This is a modified perch system that is designed to increase primate comfort in order facilitate subject cooperation during<br />

longer experiments. It also can be used as a booster seat, making it possible to use a standard chair with a smaller<br />

primate. This usually requires Extended Perch Slots (see below).<br />

1-CCT-BAG<br />

Canvas Chair <strong>Co</strong>ver<br />

Most useful for transporting the subject though sensitive areas. Also useful for keeping the chair dust free though<br />

extended storage.<br />

1-CCT-1-DBL and 1-CCT-1A-DBL<br />

Dual Neck Plate Positioners<br />

Allowing some smaller primates to fit Standard or Large Chairs. It may be necessary to use this option in conjunction<br />

with other options such as Extended Perch Slots and a second set of Neck Plates with a smaller opening.<br />

Handle Extension for Rear (Removable) Neck Plate<br />

Neck plate incorporates an eight-inch Handle (20.3cm) that gives clearance to protect researchers hand from injury<br />

caused by biting.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


1-CCT-21JOY<br />

push buttons<br />

This optional front for the TV chairs can be used to mount one to two Joysticks or<br />

Catalog Number Chair Size/Defining Option Primates to be used with<br />

1-CMT-910B-V60 Mini New World<br />

1-CST-910B-V60 Small 3 - 6 kg<br />

1-CCT-910B-V60 Standard 4 - 9 kg<br />

1-CLT-910B-V60 Large 8 - 18 kg<br />

Note: If you are working with a heavy weight primate, especially in respect to its height, you may need to use a larger<br />

chair to fit your specific needs.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


MRI Primate Chair<br />

This chair is specially designed for use with fully conscious primates inside the MRI. The chair consists of completely<br />

non-metallic materials, including the head holding and positioning apparatus mounted to a cylindrical body. The<br />

tubular design has an outside diameter of 10 ½ inches (26 ¾ cm). Other dimensions may be available upon request.<br />

Horizontal MRI Chair (1-CH1050)<br />

Univ of Alabama<br />

Our Vertical MRI chair in the MRI setup of<br />

When ordering, please specify the bore dimensions and other specifications of your MRI.<br />

This chair is now available in two designs, a Horizontal and a Vertical model. A training chair is also available as an<br />

option.<br />

For more information about this new product, please refer to the Tech Brief Section (Tech Brief XIII-1.4).<br />

Our engineering staff is here to assist you regarding any specific customizing that would assist you in your research.<br />

For more details on this new product, feel free to contact <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>., Inc.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


1-CH1050<br />

Horizontal MRI Chair<br />

1-CV1150-S<br />

Vertical MRI Chair<br />

1-CV1200<br />

Large Vertical MRI Chair<br />

Note: We can custom design your MRI chair to accommodate the size of your primate subject.<br />

Figure 1.3 Vertical MRI Chair (a)<br />

Vertical MRI Chair (b)<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Audio Primate Chair<br />

This chair features a rear post head positioning system, which leaves<br />

approximately 350 degrees of the audio range unobstructed on the horizontal<br />

plane. The vertical planes of audio range are unobstructed to 30° below the<br />

horizon on the sides and 40° below the horizon in the front due to the design of<br />

chair body’s main interface. We feel this provides the widest possible audio<br />

range for audio studies and still provides adequate stability for the head and<br />

comfortable accommodations for the primate.<br />

The head holding system consists of a two-inch square aluminum post<br />

mounted vertically in the center of the chair’s back that clamps a horizontal bar<br />

that extends forward over the primates head. <strong>Co</strong>nnected to this horizontal bar is<br />

a shorter, vertical rod that extends downward to the primate’s head and attaches<br />

to a head positioning system. This rod is adaptable to fit several different head<br />

restraint systems.<br />

This chair is a front-loading chair with a swinging door. The stainless<br />

steel spring latch of the swinging door is designed to accommodate a locking<br />

mechanism (e.g. pad lock).<br />

The neck restraint system is designed with both a rear and front plate.<br />

The rear plate is fixed onto the main body and is usually not removed. The front<br />

plate is attached by hand knobs and is guided by dual slots, which allow the<br />

plate to be removed during loading and unloading of the primate.<br />

The standard perch assembly is included with this chair (1-CC-7).<br />

Assembled with machined stainless steel rods, mounted horizontally in an<br />

aluminum frame, it is a comfortable surface for the monkey to sit or crouch.<br />

To accommodate varying heights of the primate subjects, the perch assembly<br />

is vertically adjustable up to eight inches. Additional seat options and<br />

extended perch slots are available for added comfort and range of adjustment.<br />

(See options list).<br />

The rear panel of the chair is ventilated for the subject’s comfort. The side panels of the chair are pre-drilled for<br />

optional external handles, waist restraint plate, and/or 18” (45.72cm) coil supports (wings). Our 18” (45.72cm) coil will<br />

fit this chair with the optional wings. (This chair is not, however, designed to accommodate our 15” or 38.10cm coil).<br />

Fig. 1.4<br />

Audio Primate Chair<br />

The waste tray on the Audio Chair is inserted from the front.<br />

The Audio Chair can be easily transported and elevated to a<br />

convenient working height when mounted to our standard tall base<br />

(optional), which is constructed of an aluminum frame on four nonconductive,<br />

5” (12.7cm) diameter lockable wheels. This base places the primates at a standard height of 47” to 48”<br />

(119.4cm - 121.9 cm) from the floor.<br />

A low trolley is also available. The low trolley, mainly designed for transporting, stands 6.5” (16.5cm) from the<br />

floor. The height of this trolley can be customized to match your isolation chamber level or other equipment. This<br />

specific modification is available at no extra cost if you plan to use our Isolation Chambers. See the "Bases and<br />

Trolleys" and the “Isolation Chamber” sections for additional details.<br />

AUDIO CHAIR OPTIONS<br />

1-CC-30<br />

<strong>Co</strong>il Support Wings<br />

18 inch coil mounting (Note: 15-inch coil is not compatible with the audio chair)<br />

Call for Cat-#<br />

5-inch (12.70cm) External Handles<br />

External handles allow for easy handling of the chair during set-up or transporting.<br />

1-CC-5SF<br />

Self-Feeding Neck Plate System<br />

This special neck plate allows the subject to reach its head and mouth, which may be necessary for tasks such as selffeeding.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Call for Cat-#<br />

Neck Plate System with an enlarged or reduced neck hole opening<br />

1-CC-5JC<br />

Anti-Rotation Head Blocks (jaw blocks)<br />

These dual blocks on the neck plate prevent the subject from turning its head. This is most commonly employed when a<br />

rigid head holding system is not applicable due to experimental needs.<br />

1-CC-17<br />

Aluminum Slot Liners<br />

These aluminum inserts in the perch and neck plate slots reduce stress concentration on the weaker plastic sides,<br />

extending the chair’s life.<br />

1-CC-SP-19<br />

Waist Plate System (two piece)<br />

The two-piece, waist plate system is similar to neck plate systems in that the rear plate is fixed and the removable front<br />

plate is inserted after loading the primate.<br />

1-CC-71<br />

Seat<br />

This modified perch system enhances primate comfort, extending the animals cooperation level for extended<br />

experiments. It also can be used as a booster to allow some smaller primates to fit a standard chair. (This option usually<br />

requires extended perch slots).<br />

1-CA-34<br />

Guillotine (Sliding) Front Door<br />

Front Door that opens vertically which allows the chair to be positioned directly against a cage. Included in the design is a system of<br />

hooks that engage the bars of the cage, holding the chair stationary. (Chair height should be accommodated to match the cage door<br />

height.)<br />

1-CCA-1-DBL: Right Side<br />

1-CCA-1A-DBL: Left Side Dual Neck Plate Positioners<br />

This is another option for allowing some smaller primates to fit standard or large chairs. It is often used in conjunction with other<br />

options such as extended perch slots and/or a second set of neck plates with a smaller opening.<br />

Catalog Number Chair Size/Defining Option Primate to be used with<br />

1-CCA-V50 Standard Chair 4 - 9 kg<br />

1-CLA-V50 Large Chair 8-18 kg<br />

Note: If you are working with a heavy weight primate, especially in respect to its height, you may need to use a larger<br />

chair to fit your specific needs.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Salzman/ Patton Front Door Primate Chair<br />

Fig. 1.5 Salzman/Patton Front Door Primate Chair<br />

Developed in collaboration with Dan Salzman and<br />

Joe Patton of <strong>Co</strong>lumbia University, N.Y.<br />

This modified chair was developed for the purpose of attaching sensors on the palms of the primate while the<br />

hands rest outside the front of the chair. To better the ergonomics of the chair, several adjustments were made. The rear<br />

waist plate was designed to adjust vertically rather than horizontally, allowing the vertical distance from the elbows to<br />

the shoulders to be adjusted. The subject’s elbows fit into contoured blocks, which are positioned on the waist plate and<br />

horizontally adjustable. The forearms are secured with vertically adjustable, cushioned rods, which are formed to<br />

comfortably hold the arms in place. The front waist plate is fixed to the inside of the front swinging door. The door has<br />

holes for the hands, and on the outside of the door is a hand rest that is also vertically adjustable. The wrists are<br />

protected with Velcro straps and locked with guillotine plates. All adjustments are accessible from the outside of the<br />

chair and are designed for maximum comfort. The design for this chair is based on the Standard Audio Chair. For more<br />

information, refer to the Audio Chair description (previous page).<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Open Primate Chair<br />

The upper front and sides of this chair are wide open to permit<br />

the complete range of motion for the subject’s arms. This is<br />

recommended for studies in which the subject is involved in studies<br />

requiring the performance of manipulative tasks.<br />

The Open Chair does not include a head restraint as a standard<br />

feature, however the head post that comes standard on the Audio Chair<br />

is compatible with the inclusion of some additional supports. If you<br />

prefer this option, please specify when placing your order.<br />

This chair uses a two-plate waist restraint system to keep the<br />

primate's feet below the waistline. The subject is loaded and unloaded<br />

from the front through a swinging door, which can be securely locked<br />

once the primate is in place. The neck plate system on this chair is<br />

designed to only restrain the neck and has little interference with the<br />

range of motion of the arms. This allows the subject to reach its mouth.<br />

If the subject will be handling objects that could possibly be hazardous<br />

if swallowed an optional neck plate is available to prevent this (see<br />

options list). The standard perch assembly is used on this chair. It is<br />

assembled with machined stainless steel rods horizontally mounted in<br />

an aluminum frame and provides a comfortable surface for the monkey<br />

to sit or crouch. It has an adjustable vertical range to adapt to primates<br />

of various heights. There are optional seats and extended perch slots<br />

available for added comfort and range of adjustment (see options list).<br />

The neck and waist plates have removable handles for safe installation. Fig. 1.6 Open Primate Chair<br />

The waste tray is accessible from the front and is located below the door.<br />

A drip lid was incorporated into the design just above the tray to prevent any leakage of animal waste products.<br />

Like most chairs, the Open Chair can be easily transported and elevated to a convenient working height when it<br />

is mounted on our standard tall base (optional), which is a frame constructed of aluminum on 4 non-conductive 5inch<br />

diameter lockable wheels. This base places the primates eye height at our standard height of between 47 and 48 inches<br />

(119.4-121.9 cm) from the floor level. A low base trolley is also available, which stands 6.50 inches (16.5cm) from the<br />

floor and is mainly designed for transporting the chair. The height of this trolley can be customized to accommodate the<br />

height of your isolation chamber or other equipment. This specific modification is available at no extra cost if you plan<br />

to use our isolation chambers. See the "Bases and Trolleys" and “Isolation Chamber” sections for additional details.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


OPEN CHAIR OPTIONS<br />

1-CA-93<br />

Audio Chair Post Head Holding System<br />

See the beginning of the Audio Chair Description for details.<br />

Call for Cat-#<br />

5-inch (12.70cm) External Handles<br />

For handling the chair during set-up or transporting<br />

1-CC-6<br />

Non-Self-Feeding Neck Plate (Standard Neck Plate)<br />

This neck plate prevents the primate from self-feeding, by not allowing the primate to reach its hand(s) to its mouth<br />

1-CC-6SF<br />

Self-Feeding Neck Plate<br />

This neck plate allows the primate to self-feed by permitting the primate to reach its hand(s) to its mouth.<br />

1-CC-5JC<br />

Anti-Rotation Head Blocks (jaw blocks)<br />

These dual blocks mounted on the neck plate prevent the subject from turning its head. This is most commonly<br />

employed when a rigid head holding system is not applicable due to experimental needs.<br />

1-CC-17<br />

Aluminum Slot Liners<br />

These aluminum inserts in the perch and neck plate slots reduce stress concentration on the weaker plastic sides,<br />

extending the chair’s life.<br />

Call for Cat-#<br />

Neck Plate System with an enlarged or reduced neck hole opening<br />

1-CC-71<br />

Seat<br />

This modified perch system enhances primate comfort, extending the animals cooperation level for extended<br />

experiments. It also can be used as a booster to allow some smaller primates to fit a standard chair. (When adding the<br />

seat option, extended perch slots are usually required).<br />

1-CC-6C<br />

Removable Neck Plate with Extended Handle<br />

This neck plate includes an eight-inch handle (20.3cm), providing a safe distance between the investigator and the<br />

subject.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


1-CCO-SNY<br />

Snyder Open Primate Chair<br />

(Developed in collaboration with Larry Snyder from Washington University of St. Louis, MO.)<br />

This is a variation of the Standard Open Chair with the addition of a removable cover that completely encloses<br />

the chair. The purpose of this is to allow a large range of arm movement when the cover is removed, but also allow the<br />

option of having a safe means of transporting and training the subject when the cover is in place.<br />

Snyder Open Primate Chair (1-CCO-SNY)<br />

Snyder Chair fully enclosed w/standard neck<br />

plate<br />

Like with the Standard Open Chair, the neck plate allows the primate subject to reach its mouth. A neck plate<br />

designed to prevent the subject from reaching its mouth is optional (see options list). This chair has a two-plate waist<br />

restraint system that is horizontally adjustable. The waist plate keeps the primates feet below the waist and restricts<br />

movement of the midsection. The neck and waist plates have removable handles for safe loading and unloading of the<br />

subject.<br />

This chair comes with the standard perch assembly. The standard perch assembly consists of machined<br />

stainless steel rods, mounted horizontally in an aluminum frame and provides a comfortable surface for the monkey to sit<br />

or crouch. The perch assembly is adjustable to accommodate various heights of primate subjects.<br />

A front-swinging door, equipped with a locking mechanism, is standard with this model. However, if you<br />

prefer a rear-swinging door, please specify the “Rear Door Model” when placing your order. For direct cage loading, we<br />

also offer the guillotine door option with this chair.<br />

The Open Chair does not include a head restraint as a standard feature, however the head post that comes<br />

standard on the Audio Chair is compatible along with the inclusion of some additional supports. If you prefer this<br />

option, please specify when placing your order. (Note: Audio Chair head post is only compatible with the front door<br />

model.)<br />

Like most chairs, the Open Chair can be easily transported and elevated to a convenient working height when<br />

mounted to our Standard Tall Base (Optional), which is a frame constructed of aluminum on 4 non-conductive five-inch<br />

diameter lockable wheels. This base places the primates eye height at our standard of between 47 and 48 inches (119.4-<br />

121.9 cm) from the floor level. A low trolley standing 6.50 inches (16.5cm) mainly designed for transporting is also<br />

available. The height of this trolley can be customized to match your Isolation Chamber level or other equipment. This<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


specific modification is available at no extra cost if you plan to use our Isolation Chambers. See the "Bases and<br />

Trolleys" section and the Isolation Chamber section for additional details.<br />

SNYDER CHAIR OPTIONS<br />

1) Guillotine (sliding) Front Door -- Front Door that replaces swinging door and opens vertically allowing the<br />

chair to be positioned directly against a cage. Included in the design is a system of hooks that engage the bars<br />

of the cage and prevent the chair from being pushed away. (When ordering, please specify the height of your<br />

cage door so that your chair can be designed accordingly).<br />

2) Neck Plate and Waist Plate Positioners – Available to allow larger or smaller subjects to be properly restrained<br />

in the standard sized chair.<br />

3) Rear Door Model of Snyder Chair – Swinging or guillotine rear door with solid front.<br />

4) Audio Chair Post Head Holding System -- See the beginning of the Audio Chair description for details.<br />

5) Seat - Modified perch system that enhances the subject’s comfort extending the primate’s cooperation level for<br />

extended experiments. It also can be used as a booster to allow some smaller primates to fit a standard chair.<br />

(Usually requires Extended Perch Slots)<br />

6) <strong>Co</strong>il Support Wings - For use with our 18 inch coil or 15 inch coil<br />

7) 5-inch External Handles - For handling the chair during set-up and transporting.<br />

1-CLQ-93-V50<br />

1-CQA-V50<br />

1-CQ-910-V50<br />

Large Square top chair with Front Door<br />

Standard Square top chair with Front Door<br />

Standard Square top chair With Back Door<br />

These chairs are similar to the Standard Vision Chairs except<br />

the top neck plates are parallel to the floor instead of slanting<br />

forward 22.5 degrees.<br />

Pictured below are two different head holding systems<br />

available one the original top plate or bar system and the<br />

Audio post head holding system, both are easily removable.<br />

There is also an optional chest plate to keep the monkey<br />

from rotating his body in the chair.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


1-CCD-910-V50<br />

IndistructaMax<br />

The Metal Braced Chair is<br />

similar to the Standard vision<br />

chair in size and function.<br />

· Added bracing that<br />

increases strength<br />

· Easily replaceable<br />

Polycarbonate<br />

panels<br />

· Animal <strong>Co</strong>mfort<br />

· Safety for the<br />

Technician<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


1-CCF-01<br />

<strong>Co</strong>nformaMax<br />

Chair System<br />

For versatility and durability,<br />

it’s the one chair system worthy<br />

of a standing ovation<br />

Stainless steel and anodized aluminum<br />

construction means hundreds of<br />

configurations<br />

- with zero corrosion - over a longer service<br />

life.<br />

Adjustment is smooth, easy and virtually<br />

impervious to damage from chemical<br />

cleaners<br />

thanks to our UHMW polyethylene slide<br />

bearings.<br />

Waste management and removal<br />

is as easy as sliding out the tray.<br />

Our 5” wheels offers greater mobility and<br />

the two-way locks ensure secure<br />

positioning.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


1-CLPBF<br />

Push Button Chair<br />

This chair designed for behavioral or visual motor skill studies. The chair is available with two or<br />

three buttons which can be wired in parallel or series.<br />

Options Available are:<br />

1. Slide button <strong>Co</strong>vers<br />

2. Arm Blockers (left and Right)<br />

3. and many of the Standard Chair options<br />

This chair is only available in a back door model.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


1-CC-10BF Top Bar, TRAPEZE STYLE:<br />

This new system incorporates the new top bar (1-CC-10BF). This system gives you the ultimate in versatility. When<br />

used with the Swivel Head Holder, The Head Holder on the Head can be mounted virtually anywhere on the head. The<br />

trapeze type head positioners side supports are mounted on the chair side with a pivot allowing the top bar to be<br />

positioned anywhere front to back. There is a locking pin to lock the positioner in a vertical position. The swivel Head<br />

holder can be positioned anywhere left to right. This will give you the freedom to position the head in any direction. The<br />

side plates and top bar are made from Aluminum but can be made from plastics for FMRI and CAT scan Applications.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Chair Parts Options<br />

All chairs are available with the following options and/or as replacement<br />

spare parts. When you order options, be sure to specify which model and<br />

size chair you will be using; e.g. CCP, CSP, CCT. Options may be<br />

ordered either along with your chair or at a later time as your<br />

investigations proceed.<br />

DESIGN A CHAIR TO MEET YOUR OWN<br />

PROTOCOLS<br />

All chairs can be custom designed to meet your specific research<br />

requirements. Feel free to contact us to discuss any comments, questions, or suggestions. We will<br />

work with you personally to help accommodate your particular needs.<br />

CHAIR SIDES<br />

Part Number<br />

1-CC-1<br />

1-CC-1A<br />

1-CC-1-17<br />

1-CC-1A-17<br />

1-CC-1-34<br />

1-CC-1A-34<br />

1-CC-93S<br />

1-CC-1A-93S<br />

1-CC-1-D<br />

1-CC-1-DBL<br />

1-CC-1A-DBL<br />

1-CC-1-DBL-93S<br />

1-CC-1A-DBL-93S<br />

1-CCA-1<br />

1-CCA-1A<br />

1-CCA-1-34<br />

1-CCA-1A-34<br />

1-CCA-1-93S<br />

1-CCA-1A-93S<br />

1-CCA-1-76AR<br />

1-CCA-1A-76AR<br />

1-CCAW-1AB<br />

1-CCAW-1T<br />

1-CCAW-1AT<br />

1-CCAW-1AT-A<br />

1-CCAW-1AT-B<br />

1-CCAW-1TW<br />

1-CCA-1-DBL<br />

1-CCA-1A-DBL<br />

1-CCA-1-DBL-93S<br />

1-CCA-1A-DBL-93S<br />

1-SNYCH-A-1<br />

1-SNYCH-A-1A<br />

1-SNYCH-F1<br />

1-SNYCH-F1A<br />

1-SNYCH-1<br />

1-SNYCH-1A<br />

1-CCO-1<br />

Part Number<br />

1-CCO-1A<br />

1-CCO-1-OLD<br />

1-CCO-1A-OLD<br />

1-CCT-1<br />

Description<br />

Standard chair right side<br />

Standard chair left side<br />

Standard chair right side for chairs with slot liners<br />

Standard chair left side for chairs with slot liners<br />

Standard chair right side for chairs with Guillotine door<br />

Standard chair left side for chairs with Guillotine door<br />

Standard chair right side for chairs wit audio post on the side<br />

Standard chair Left side for chairs with Audio Post on the side<br />

Standard chair right side for Dutch Doors (left side is 1-CC-1A)<br />

Standard chair right side for chairs with double neck plate slots<br />

Standard chair left side for chairs with double neck plate slots<br />

Standard chair right side with double neck plate slots and audio post on the side<br />

Standard chair left side with double neck plate slots and audio post on the side<br />

Standard Audio style chair right side<br />

Standard Audio style chair left sides<br />

Standard Audio style chair with Guillotine door<br />

Standard Audio style chair left sides with guillotine door<br />

Standard Audio style chair Right Side with Audio post on the Side<br />

Standard Audio style chair left Side with Audio post on the Side<br />

Standard Audio style chair right sides for chairs with arm restraint<br />

Standard Audio style chair left sides for chairs with arm restraint<br />

Standard Audio style chair sides for wire mesh chairs (Left and Right)<br />

Standard Audio style chair right sides for wire mesh chairs<br />

Standard Audio style chair left sides for wire mesh chairs<br />

Wire edge covers for top side (two needed per chair)<br />

Wire edge cover for bottom side (two needed per chair)<br />

Mesh for wire mesh audio chair (two Per Chair)<br />

Standard Audio style chair right side for chairs with double neck plate slots<br />

Standard Audio Style chair left side for chairs with double neck plate slots<br />

Standard Audio Chair right side with double neck plate slots and Audio post on the side<br />

Standard Audio Chair left side with double neck plate slots and Audio post on the side<br />

Right side Snyder style chair with audio post, wings and non self feeding neck plate<br />

Left Side Snyder style chair with audio post, wings and non self feeding neck plate<br />

Special audio chair with foot port for Dr. Snyder right side<br />

Special audio chair with foot port for Dr. Snyder left side<br />

Special Snyder chair right side<br />

Special Snyder chair left side<br />

Standard Open front chair right side<br />

Description<br />

Standard Open front chair left side<br />

Open Front Chair right side smaller than Standard (replacement parts only)<br />

Open Front Chair left side smaller than Standard (replacement parts only)<br />

Standard TV style Chair right side<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


1-CCT-1A<br />

1-CCT-1-17<br />

1-CCT-1A-17<br />

1-CCT-1-34<br />

1-CCT-1A-34<br />

1-CCT-1-BF<br />

1-CCT-1A-BF<br />

1-CCT-1-93<br />

1-CCT-1A-93<br />

1-CCT-1-93S<br />

1-CCT-1A-93S<br />

1-CCT-1-SHORT<br />

1-CCT-1A-SHORT<br />

1-CCT-1-D<br />

1-CCT-1-D-DBL-S<br />

1-CCT-1A-D-DBL-S<br />

1-CL-1<br />

1-CL-1A<br />

1-CL-1-17<br />

1-CL-1A-17<br />

1-CL-1-1753<br />

1-CL-1A-1753<br />

1-CL-1-1718<br />

1-CL-1A-1718<br />

1-CL-1-34<br />

1-CL-1A-34<br />

1-CL-1-D<br />

1-CLA-1<br />

1-CLA-1A<br />

1-CLA-1-34<br />

1-CLA-1A-34<br />

1-CLA-1-76AR<br />

1-CLA-1A-76AR<br />

1-CLT-1<br />

1-CLT-1A<br />

1-CLT-1-D<br />

1-CLT-1-D-DBL-S<br />

1-CLT-1A-D-DBL-S<br />

1-CLT-1-17<br />

1-CLT-1A-17<br />

1-CLT-1-18<br />

1-CLT-1A-18<br />

1-CLO-1<br />

1-CLO-1A<br />

1-SHALL-2<br />

1-CS-1<br />

1-CS-1A<br />

1-CS-1A-34<br />

1-SNY3-1<br />

1-SNY3-1A<br />

1-CSTBM-1<br />

1-CSTBM-1A<br />

Standard TV style Chair left side<br />

Standard TV style Chair right side for chairs with slot liners<br />

Standard TV style Chair left side for chairs with slot liners<br />

Standard TV style Chair right side for chairs with guillotine door<br />

Standard TV style Chair left side for chairs with guillotine door<br />

Standard TV Style Chair right side for trapeze head holder and Chuck Chase coil<br />

Standard TV Style Chair left side for trapeze head holder and Chuck Chase coil<br />

Standard TV chair right side with audio attachment<br />

Standard TV chair left side with audio attachment<br />

Standard TV chair with Audio Post on the side<br />

Standard TV chair with Audio post on the side<br />

TV Chair short right side<br />

TV Chair short left side<br />

Standard TV chair with Dutch door right side (Left side is same as 1-CCT-1A)<br />

Std TV chair with Dutch door and double neck plate right side (This side has 2 pc. Waist plate option)<br />

Std TV chair with Dutch door and double neck plate left side (This side has 2 pc. Waist plate option)<br />

Large chair right side<br />

Large chair left side<br />

Large chair right side for chairs with slot liners<br />

Large chair left side for chairs with slot liners<br />

Large Chair Right Side for Chairs with Slot liners and Primate Products Neck Plate<br />

Large Chair Left Side For Chairs With Slot Liners and Primate Products Neck Plate<br />

Large chair right side with extended slots and slot liners<br />

Large chair left side with extended slots and slot liners<br />

Large chair right Side for chairs with Guillotine door<br />

Large chair left side for chairs with Guillotine door<br />

Large chair with Dutch doors right side<br />

Large chair right sides for Audio style chairs<br />

Large chair left sides for Audio style chairs<br />

Large chair right sides for Audio style chairs with guillotine door<br />

Large chair left sides for Audio style chairs with guillotine door<br />

Large chair right sides for Audio style chairs with arm restraint<br />

Large chair left sides for Audio style chairs with arm restraint<br />

Large Chair right side for TV style chairs<br />

Large Chair left side for TV style chairs<br />

Large TV chair with Dutch door right side<br />

Large TV chair for Dutch door and double neck plate right side (with two piece waist plate option)<br />

Large TV chair for Dutch door and double neck plate left side (with two piece waist plate)<br />

Large TV style Chair right side for chairs with slot liners<br />

Large TV style Chair left side for chairs with slot liners<br />

Large TV Chair right sides with extended slots<br />

Large TV Chair left sides with extended slots<br />

Large Open front chair right side<br />

Large Open front chair left side<br />

Chair side for Schall chair<br />

Small Chair right side<br />

Small Chair left side<br />

Small Chair for guillotine rear door left side<br />

Small Tall Chair right side<br />

Small Tall Chair left side<br />

Right side Murray chair<br />

Left side for Murray Chair<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


CHAIR FRONTS<br />

1-CCA-2<br />

1-CCA-28-76HR<br />

1- Front Door for Wire<br />

CCAW-2 Mesh Audio Chair<br />

Front Door for Audio Chair<br />

Salzman type reach front<br />

1-CCAW- Wire Mesh for Front Door Wire Mesh Audio Chair<br />

2-W<br />

1-CCAW- Front edge of right and left side of wire mesh audio chair<br />

2-E<br />

1-CCT-21A Arm Barrier for TV Chair (reversible for left & right hand extensions)<br />

1-CCT- Front Slide Brackets for TV Style Chair<br />

21B-1<br />

1-CCT- Front Slide Bracket for TV style Chairs<br />

21B-2<br />

1-CCT-21C Fixed Lower Front Panel for TV Chairs<br />

1-CCT-21D Safety Barrier for TV Chair<br />

1-CCT- Fixed Front Panel for Short TV Chair<br />

21CS<br />

Arm Barrier for Schultz TV Chair (reduces allowed out reach space)<br />

1-CCT- Joy Stick Front Panel<br />

21JOY-1<br />

1-CCT- Joy Stick Box Side Plates (two Required)<br />

21JOY-2<br />

1-CCT- Top of <strong>Co</strong>mpartment For Joy Stick<br />

21JOY-3<br />

1-CCT- <strong>Co</strong>mpartment Back for Joy Stick <strong>Co</strong>ver<br />

21JOY-4<br />

1-CCT-<br />

21JOY-5<br />

1-CCO-2-A Front Door Spacer for Open Chair<br />

Fixed front panel for Snyder chair<br />

Fixed Front Panel for Snyder type Small Tall Chair<br />

1-CS-2A-1<br />

Removable Touch Panel for Small Chairs<br />

1-CS-2A-2<br />

Bracket for removable touch panel for Small Chairs<br />

Fixed Front Panel for Small Chair (non removable touch sensor handle for CSP Chairs)<br />

1-CSTBM-21A Arm barrier for Murray Chair<br />

1-CSTBM-21B Front slide Bracket for Murray Chair<br />

1-CSTBM-21C Front panel for Murray chair<br />

1-CSTBM-21D Safety panel for Murray Chair<br />

Fixed Front Panel for Large Chairs<br />

Fixed Front for Large Chairs with Removable Touch Sensor<br />

1-CCT-<br />

21<br />

TV Chair Front<br />

Assembly<br />

1-CC-21A-M1SCHULTZ<br />

1-CCT- Joy Stick Attachment<br />

21JOY for TV style Chairs<br />

1-CCO-2 Front door for Open<br />

chair<br />

1-SNYCH-2C<br />

1-SNY3-2W<br />

1-CS-2A Front panel for Small<br />

Chair with removable<br />

touch bar<br />

1-CS-2<br />

1-CSTBM- Murray Small Chair<br />

21<br />

Assembly<br />

1-CL-2<br />

1-CL-2A<br />

Part Number <strong>Co</strong>mponent Description<br />

1-CC-2<br />

Standard chair front<br />

1-CC-2-DBL<br />

Standard Chair Front for Chairs with Double Neck Plate Slots<br />

1-CC-25 Knee Separator Front 1-CC-25A Fixed front panel for standard chairs with knee separator<br />

Panel Assembly<br />

1-CC-25C- Angle plates for knee plate<br />

1<br />

1-CC-25C- Angle plates for knee plate<br />

2<br />

1-CC-25-D KNEE SEPARATOR PANEL<br />

1-CC-25B- Left side Angle Plates for Knee Separator for Prichard’s chair only<br />

L<br />

1-CC-25B- Right side Angle Plates for Knee Separator For Prichard’s chair only<br />

R<br />

1-CC-2A Chair front with<br />

1-CC-2A-1 Removable front panel<br />

removable touch sensor 1-CC-2A-2 Removable Front panel bracket for standard chairs<br />

assembly<br />

1-CC-2A-3 Chair Front for Removable Touch Sensor (panel)<br />

1-CCW-2<br />

Fixed front for standard chairs with out touch sensor<br />

1-SCHALL-5<br />

Custom chair for Vanderbilt<br />

1-DDC-2 Custom Front Panel for 1-DDC-2A Custom front upper panel for NIH<br />

Desimon Chair<br />

1-DDC-2B Custom front lower panel for NIH<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Part Number <strong>Co</strong>mponent Description<br />

1-CLW-2<br />

Fixed Front Panel for Large Chairs (for chairs with no touch sensor)<br />

1-CLT-21 Large TV Chair 1-CLT-21A Arm barrier for large TV chairs<br />

Front<br />

1-CLT-21B Aluminum slide brackets for large TV chairs<br />

1-CLT-21C Fixed front panel for large TV chairs<br />

1-CLT-21D Safety Barrier for large TV front chairs<br />

1-CLT-21AF TV Chair Front 1-CLT-21AF Arm barrier for large TV chairs with foot port option<br />

with Foot Port 1-CLT-21CF Fixed front panel for large TV chairs with foot port option<br />

Option<br />

1-CLT-21AFL Foot port barrier for large chairs with foot port option<br />

1-CLT-21BF Foot Port slides for large TV Chairs with foot Port Option<br />

1-CM-21A Front panel for 1-CM-2A-1<br />

Removable touch bar panel mini chair<br />

removable front 1-CM-2A-2<br />

Bracket for removable touch bar mini chair<br />

mini chair 1-CM-2A-3<br />

Bracket for removable touch bar panel<br />

1-CM-2<br />

Fixed front panel 1-CM-2A1<br />

Removable touch panel for mini chair<br />

for mini chairs 1-CM-2A2<br />

Bracket for removable touch bar panel for mini chairs<br />

ACCESS:<br />

The rear door (or front door- depending on model) opens fully. The rear neck plate is easily removable. Using the <strong>Crist</strong><br />

<strong>Instrument</strong> <strong>Co</strong>mpany Monkey Pole (2-HMP-02) and chain type collar (2-HCM), your subject is easily maneuvered from<br />

his cage to the chair and back again.<br />

CHAIR BACKS<br />

Part Number<br />

1-CC-3<br />

1-CC-3-DBL<br />

1-CC-32A-32B<br />

Standard Chair<br />

Dutch Door Assembly for<br />

Description<br />

Rear door for standard type chair<br />

Rear Door For Standard chairs with Double Neck Plate Slots<br />

1-CC-32U<br />

Upper Dutch door for<br />

Standard chair<br />

1-CC-32L<br />

Lower rear door for<br />

standard chair<br />

1-CC-34<br />

Guillotine door for standard chairs<br />

1-CC-39 Tilt Brace ASSEMBLY 1-CC-39L Lower tilt brace<br />

1-CCA-3<br />

1-CCA-3-DBL<br />

1-CCA-34<br />

1-CCAW-31<br />

audio chair<br />

Fixed rear panel for wire mesh<br />

1-CC-39U<br />

1-CC-39B<br />

Upper tilt brace<br />

Tilt brace pivot<br />

Fixed rear panel for audio chair<br />

Back Panel for audio chair with double neck plates<br />

Guillotine door for audio chair<br />

1-CCAW-31-A<br />

Top wire edge cover for<br />

wire mesh audio chair<br />

1-CCAW-31-B<br />

1-CCAW-31W<br />

Wire Edge <strong>Co</strong>ver for Rear<br />

Plate<br />

Wire mesh for rear panel<br />

1-CCT-3<br />

1-CCT-3-SHORT<br />

1-CCT-32U<br />

1-CCT-32L<br />

1-CCT-34<br />

1-CCT-34-M1SCHULTZ<br />

1-CCT-34-LT<br />

1-CCT-3-93<br />

1-CCT-32U-DBL<br />

1-CCT-32L-DBL<br />

1-CCO-3<br />

Rear door for TV chair<br />

Rear door for short TV chair<br />

Upper Dutch door for TV chair<br />

Lower Dutch door for TV chair<br />

Guillotine door for TV chair<br />

Modified Guillotine Door for Schultz TV Chair<br />

Locking Tab for Guillotine Door (use with 1-CCT-34-M1Schultz)<br />

BACK for TV chair with audio post<br />

Upper Dutch door for TV chair (standard size Harvard chair)<br />

Lower Dutch door for TV chair (standard size Harvard chair)<br />

Back panel for open chair<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Part Number<br />

1-SNYCH-34A<br />

1-SNYCH-3<br />

1-SNYCH-31-OLD<br />

1-SNYCH-31<br />

1-SNYCH-31-DBL<br />

1-SNYCH-34<br />

1-SNYCH-34A<br />

1-SNYCH-34B<br />

1-SNY3-3<br />

1-CS-3<br />

1-CS-34<br />

1-CSTBM-3<br />

1-CL-3<br />

1-CL-32U<br />

1-CL-32L<br />

1-CL-34<br />

1-CLT-32U<br />

1-CLT-32U-DBL<br />

1-CM-3<br />

Description<br />

Guillotine door for Snyder special chair<br />

Rear Door for Snyder chair<br />

Rear panel for audio type Snyder chairs<br />

Fixed rear panel for Snyder type Chairs<br />

Fixed rear panel for Snyder type Chairs with Double Neck Plates<br />

Guillotine door for Snyder type chairs<br />

Guillotine door Short for Snyder type chairs<br />

Extra short guillotine for Snyder type chair<br />

Rear door for small tall chair<br />

Rear door for Small Chair<br />

Guillotine door for Small Chair<br />

Rear door for Murray chair<br />

Rear door for large chair<br />

Upper Dutch door for large chairs<br />

Lower Dutch door for large chairs<br />

Guillotine door for large chairs<br />

Upper Dutch door for large TV chairs<br />

Upper Dutch door for large TV chair (Harvard)<br />

Rear door for mini chair<br />

NECK PLATES:<br />

These neck plates are designed to<br />

accommodate a wide range of neck sizes and positions without<br />

chafing when properly adjusted. Locking screws are positioned to prevent accidental choking when<br />

in use. This system also retains the subject in the chairs. The Front Neck Plate comes with either<br />

knobs or Allen cap screws. Your choice is important.<br />

Part Number / Description <strong>Co</strong>mponents Description<br />

1-CCA-5 / Fixed Neck plate for audio chair<br />

1-CCA-53 / Fixed Neck Plate for Audio Chairs with Primate<br />

Products <strong>Co</strong>llar option<br />

1-CCA-53B Main Neck Plate for audio Chairs with<br />

Primate Products Neck Plate<br />

1-CCA-53C-<br />

R<br />

Upper right Clamping Plate for Audio<br />

Chairs with Primate Products Neck Plate<br />

1-CCA-53C-<br />

L<br />

Upper Left Clamping Plate for Audio<br />

Chairs with Primate Products Neck Plate<br />

1-CCA-53D Lower Clamping Plate for Audio Chairs<br />

with Primate Products Neck Plate<br />

1-CCA-53E Chase Plate for Audio Chairs with<br />

Primate Products Neck Plate<br />

1-CCA-53F Main Flanges for Audio Chairs with<br />

Primate Products Neck Plate<br />

1-CC-5A Fixed Neck plate for standard chair<br />

1-CC-5F Fixed self feed Neck plate for standard chair<br />

1-CC-5FG Fixed Self Feed Neck Plate for standard with Guillotine door<br />

1-CC-5FG-M1-SCHULTZ Fixed Self Feed Neck Plate Modified for Schultz<br />

1-CC-5H Fixed Neck plate for standard chair small neck hole for cebis monks<br />

1-CC-5J Fixed Neck plate assembly drawing for standard 1-CC-5JA Removable neck plate for standard chair<br />

chair with jaw blocks<br />

with Jaw Blocks<br />

1-CC-5JB Adjustable slide for jaw block style neck<br />

plate (2 required)<br />

1-CC-5JC-L Jaw Block, Left side for standard chair<br />

1-CC-5JC-R Jaw Block, Right side for standard chair<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Part Number / Description <strong>Co</strong>mponents Description<br />

1-CC-5K Fixed Neck plate for standard chair with guillotine door (shorter open end by 2.5 inches)<br />

1-CC-5L Fixed Neck plate for standard chair neck plate is longer on the closed end<br />

1-CC-53 Neck plate for Primate<br />

1-CC-53B Main Neck Plate<br />

Products 4” <strong>Co</strong>llar Standard<br />

1-CC-53C Upper flanges (two Per Neck Plate)<br />

assembly drawing All other sizes<br />

1-CC-53D Lower Flanges (two Per Neck Plate)<br />

are available<br />

1-CC-53E Chase Plate<br />

1-CC-53F Main Flanges (two Per Neck Plate)<br />

1-CC-52 Neck Plate for Primate Products <strong>Co</strong>llar (short 1-CC-52B Main Neck Plate<br />

Version) for Guillotine Door assembly drawing<br />

1-CC-52C-L Clamping Plate Left Side<br />

1-CC-52C-R Clamping Plate Right side<br />

1-CC-52D Lower Clamping Plate (two Required per<br />

chair)<br />

1-CC-52F Main Flange<br />

1-CCO-5H3P Special Fixed Neck plate for open chair (also fits the audio chair self feed style Aluminum) For<br />

R. Tuner<br />

1-CCO-5SF Fixed Neck plate for open chair (also fits the audio chair self feed style)<br />

1-CCO-53 Neck plate for open chair w/ Primate Products 1-CCO-53A Special neck plate for open chairs for use<br />

collar<br />

with Primate Product neck plates<br />

1-CCO-53C Upper retainer for Primate Products neck<br />

plate<br />

1-CCO-53D Lower retainer for Primate Products<br />

Neck Plate<br />

1-CCO-53E Retainer plate for Primate Products neck<br />

plate<br />

1-CCT-5 Fixed neck plate for TV chair<br />

1-CCT-5SC Fixed Neck plate for TV chairs with dual neck plates<br />

1-CCT-5F Fixed Neck plate for self feed neck plate for TV chair<br />

1-CL-5 Fixed Neck plate for Large Chair<br />

1-CL-5D Fixed Neck plate for large chair with small neck plate opening<br />

1-CL-5EC-1.75 Fixed Neck plate for large chair closed end longer by 1.75”<br />

1-CL-5EC-2 Fixed Neck plate for large chair closed end longer by 2”<br />

1-CLT-5SC Fixed Neck plate for large TV chair with Dual neck plates<br />

1-CS-5 Fixed Neck plate for Small Chairs<br />

1-CS-53 Fixed Neck plate for Small Chair for Primate 1-CS-53B Main Plate for Primate Products Style<br />

Products collar assembly drawing<br />

Neck Plate on Small Chair<br />

1-CS-53C Upper flange for Small Chair for Primate<br />

Products collar<br />

1-CS-53D Lower flange for Small Chair for Primate<br />

Products collar<br />

1-CS-53E Chase plate for Small Chair for Primate<br />

Products collar<br />

1-CS-53F Main flange for Small Chair for Primate<br />

Products collar<br />

1-CM-5 Fixed Neck plate for mini chair<br />

1-CM-5S Neck plate Support for mini chair<br />

1-DDC-5S Neck plate support bracket for Desimone chair<br />

1-SNYCH-5 Fixed Self Feed Neck Plate for Snyder Rear door Chairs w/large Neck Plate Opening<br />

1-SNYCH-5H Fixed Self Feed Neck plate for BACK DOOR Snyder chair (Front Door Models only)<br />

1-SNYCH-5K Rear facing Fixed Neck Plate<br />

1-SCHALL8-A Fixed Neck plate for (this is a two part neck plate)<br />

1-SCHALL8-B Fixed Neck plate for Vanderbilt goes with 1-SCHALL8-A<br />

1-SPCMURR-5 Fixed Self feed neck plate for Murray Chair<br />

1-CSTBM-5B Fixed Neck plate for neck plate for Murray Chair<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Removable Neck Plates<br />

Part Number<br />

1-CC-6<br />

1-CC-6C<br />

1-CC-6F<br />

1-CC-6FG<br />

1-CC-6FG-M1-SCHULTZ<br />

1-CC-6H<br />

1-CC-6G<br />

1-CCW-6<br />

1-CCO-6<br />

1-CCO-6H3P<br />

1-CCO-6SF<br />

1-CL-6<br />

1-CL-6D<br />

1-CS-6<br />

1-CM-6<br />

1-DDC-6<br />

1-SNYCH-F-6<br />

1-SNYCH-6<br />

1-SNYCH-6H<br />

1-SNYCH-6K<br />

1-SCHALL6<br />

1-SCHALL7<br />

1-SPCMURR-6<br />

1-CSTBM-6<br />

Description<br />

Removable Rear Neck Plate for Standard Chairs<br />

Removable Rear Neck Plate with Handle for Standard Chairs<br />

Removable Self Feed Neck Plate for Standard and TV Chairs<br />

Removable Rear Self Feed Neck Plate for Standard Chairs with Guillotine Back Door<br />

Removable Rear Self Feed Neck Plate for Schultz<br />

Removable Rear Neck Plate with Small Neck Opening for Standard Chairs<br />

Removable Rear Neck Plate for Guillotine Door<br />

Removable Rear Neck Plate for Wurtz Chair<br />

Removable Rear Neck Plate for Open Chair (old)<br />

Special Removable Neck Plate for Open chair (Aluminum) For R. Turner<br />

Removable Rear Neck Plate for Open chair with Self Feed Neck Plate<br />

Removable Large Rear Neck Plate for Large Chairs<br />

Removable Rear Neck plate Small Hole for Large Chairs<br />

Removable Rear Neck Plate for Small Chairs<br />

Removable Rear Neck Plate for Mini Chairs<br />

Removable Neck Plate, Rear for Desimone Chair<br />

Rear Neck Plate for Snyder chair with Foot Port<br />

Rear Neck Plate for Front Door Snyder Chair<br />

Removable self Feed Neck Plate for Back door<br />

Front removable neck plate Snyder Chair<br />

Base Neck Plate for Schall Chair<br />

Hardware to Mount Neck Plate on Schall Chair<br />

Special Rear Self Feed Neck Plate for Murray<br />

Rear Neck P late with handle for Murray Chair<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


ADJUSTABLE ROD BOTTOM PERCH:<br />

Primate rests comfortably and naturally in a squatting position. The adjustability of the perch, up or down,<br />

helps prevent atrophy and/or strain on leg muscles. Fabricated from stainless steel and aluminum, it also<br />

provides a continuity contact point for the Touch Bar.<br />

Perches are made with Stainless Steel cross bars and Aluminum sidebars to provide continuity for the Touch<br />

Panel. It includes 4 clamping screws for mounting on chair. Perch clamps to the Chair Sides without<br />

stressing the chair.<br />

The Perch provides a comfortable platform for the monkey to crouch in a natural position.<br />

Part Number / Description <strong>Co</strong>mponents Description<br />

1-CC-7 / Perch for Standard chair 1-CC-7A Side rails for standard chair perch<br />

1-CC-7L<br />

Long cross rails for standard chair perch<br />

1-CC-7S<br />

Short cross rails for standard chair perch<br />

1-CC-71 / Seat for standard size chairs<br />

1-CL-7 / Perch for Large Chairs 1-CL-7A Side rails for perch<br />

1-CL-7L<br />

Long rods for chair perch<br />

1-CL-7S<br />

Short rods for chair perch<br />

1-CL-71 / Seat for large chars<br />

1-CCT-HARV-7A / Seat for Harvard chair<br />

1-CCT-HARV-7A- Side rails for Harvard chair<br />

A<br />

1-CCT-HARV-7A-S Short cross rail for seat and perch<br />

1-CCT-HARV-7A-L Long cross rail for seat and perch<br />

1-CCO-7-OLD /Perch for old style open chair 1-CCO-7A-OLD Side rails for old style open chair perch<br />

1-CCO-7L-OLD Cross rails for old style open chair perch<br />

1-CCO-7S-OLD Short cross rails for old style open chair<br />

1-CLT-HARV-7 / Perch for large chairs with 3/8 cross<br />

bars<br />

1-CLT-HARV-7A Side rails for large perch with 3/8” cross<br />

bars<br />

1-CLT-HARV-7L 3/8” Cross bars long<br />

1-CLT-HARV-7S 3/8” Cross bars short<br />

1-CS-7 / Perch for Small Chair 1-CS-7-A Side bar for Small Chair perch and seat<br />

1-CS-7-L<br />

Long cross rails for Small Chair perch<br />

1-CS-7-S<br />

Short cross rails for Small Chair perch<br />

1-CS-71 / Seat for Small Chairs<br />

1-CM-7 / Perch for mini chair 1-CM-7A Side rails for mini perch<br />

1-CM-7L<br />

Long Cross bars for mini perch<br />

1-CM-7S<br />

Short cross bars for mini perch<br />

1-CM-71 / Seat for Mini Chairs<br />

1-CSTBM-7 / Perch for Murray chair 1-CSTBM-7A Side rails for Murray chair<br />

1-CSTBM-7B Cross rail for Murray chair<br />

1-SNY3-7 / Perch for Snyder small tall chair 1-SNY3-7A Side rails for Snyder small tall chair<br />

1-SNY3-7L Long cross rails for Snyder small tall chair<br />

1-SNY3-7S Short cross rails for Snyder Small Chair<br />

1-SCHALL1 / Perch for Schall Chair 1-SCHALL-1A Side Rails for Shall Chair (two per chair)<br />

1-SCHALL-1B Cross bars for Shall Chair (twelve per<br />

chair)<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


WAIST RESTRAINER PLATE:<br />

Suggested when using the chair with open front and sides to prevent primate from sticking his feet outside of the chair.<br />

This option is available in sizes to fit all size chairs and primates.<br />

Part Number<br />

1-CC-19<br />

1-CC-19-M1SCHULTZ<br />

1-CC-19A<br />

1-CC19SPLIT<br />

1-SNYCH-19M2<br />

1-CS-19<br />

1-CCO-19<br />

1-CSTBM-19<br />

1-CL-19<br />

1-CLT-19A<br />

Description<br />

Waist Restraint Plate for standard Chairs<br />

Waist Restraint for Schultz TV Chair<br />

Supplemental Waist Restraint For Standard Chairs<br />

Split Waist Restraint<br />

Waist Restraint Plate (may be deleted)<br />

WAIST RESTRAINT for Small Chairs<br />

Waist Restraint for Open Chair<br />

Waist Restraint for Murray Chair<br />

Waist Restraint Plate for Large Chairs<br />

Supplemental Waist Restraint w/Foot Port Option<br />

COIL SUPPORTS “WINGS”<br />

The Supports attach to the side of the chair body to accommodate the 15-inch or 18-inch Search <strong>Co</strong>il.<br />

Part Number<br />

1-CC-30<br />

1-CC-30A<br />

1-CC-30B<br />

1-CC-302<br />

1-CC-3020A<br />

1-CC-3020B<br />

1-CCT-30-CC1<br />

1-CCT-30-CC2<br />

1-DDC-30<br />

1-CS-30<br />

Description<br />

Wings for standard and large Chairs<br />

Wings Backer Plate<br />

Wing Brace<br />

Wings for 20” coils and Larger<br />

Backer Plate for Wings<br />

Brace for Wings<br />

Wings for Standard TV Chair with modifications for Chuck Chase <strong>Co</strong>il<br />

Wing Adjustment Plate for modified wings (1-CCT-30-CC1)<br />

COIL SUPPORT FOR DESIMONE CHAIR<br />

WINGS FOR SMALL CHAIRS<br />

WASTE TRAY<br />

The deep tray sized for your individual chair is easy to remove without disturbing any settings of the chair or the comfort<br />

of the animal while experiments are in progress. All waste is completely contained.<br />

Part Number<br />

1-CC-70<br />

1-SNYCH-70<br />

1-CL-70<br />

1-CS-70<br />

1-CCO-13-OLD<br />

1-CSTBM-70<br />

Description<br />

Waste Tray for Standard Chairs<br />

Waste Tray for Snyder Chair<br />

Waste Tray for Large Chairs<br />

Waste Tray for Small Chair<br />

Waste Tray for Old Style Open Chair<br />

Waste Tray for Murray Chair<br />

The collection tray for excretory waste slides conveniently into bottom of chair and fastens securely in place. It can be<br />

easily removed and replaced during the tasking period. Selecting an extra tray makes removing the full tray and<br />

replacing it with a clean, empty tray helps to prevent mishaps while the full tray is being emptied.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Chair Bottom w/ Aluminum Angles<br />

Part Number /Description <strong>Co</strong>mponents Description<br />

1-CC-8 / Standard Base Assembly for 1-CC-8A Base Plate for Standard Chairs<br />

Standard Chairs<br />

1-CC-8B Aluminum side angles for chair base<br />

1-CC-8I / Standard chair base for old 1-CC-8IA Base Plate for old style ISO box<br />

style ISO box positioner<br />

1-CC-8B Aluminum side angles<br />

1-CL-8 / Large Base Assembly for Large 1-CL-8A Base Plate for Large Chairs<br />

Chairs<br />

1-CL-8B Aluminum angles for large chair base<br />

1-CL-81 / Large chair base for old style 1-CL-8A Base Plate for Large Chairs Old Style<br />

ISO chamber positioner<br />

1-CL-8B Aluminum Angles for large Chair Base Old Style<br />

1-CS-8 / Small Base Assembly for Small 1-CS-8A Base Plate for Small Chairs<br />

Chair Bottom Plate<br />

1-CS-8B Small Chair bottom support angles<br />

1-CM-8 / Base Plate Assembly for Mini 1-CM-8A Base Plate for Mini Chairs<br />

Chairs<br />

1-CM-8B Chair Bottom Support Angles for Mini Chairs<br />

1-DDC-8 / Bottom plate assembly 1-DDC-8 Bottom plate<br />

(Desimone Chair)<br />

1-DDC-8A Base angles<br />

1-SNY3-8 / Base Assembly for Snyder 1-SNY3-8A Small Tall Chair Bottom Plate<br />

Small Tall Chair<br />

1-SNY3-8B Chair bottom Support<br />

1-SNYCH-8 /Base Assembly for Snyder 1-SNYCH-8A Chair base for Snyder Chair<br />

Chair Standard Models<br />

1-SNYCH-8B Aluminum angles for Chair base for Snyder chair<br />

1-CSTBM-8 / Base Assembly for Chair 1-CSTBM-8A Chair Bottom Plate<br />

Bottom Plate Murray Style Chair 1-CSTBM-8B Chair bottom support angles<br />

Side Head Supports<br />

Part Number<br />

1-CC-9<br />

1-CC-9B<br />

1-CC-9BF<br />

1-CL-9<br />

1-CL-9B<br />

1-CS-9<br />

1-CS-9B<br />

1-CS-9-OLD<br />

1-CM-9A<br />

Description<br />

Side Head Support for Top Plate (Pair)<br />

Side Head Support for Universal Top Bar (Pair)<br />

Trapeze Model Side Head Support<br />

Side Head Support Assembly for Large Chairs w/Top Plate<br />

Side Head Support Assembly for Large Chairs w/Top Bar<br />

Side Head Support for Small Chair w/Top Plate<br />

Side Head Support for Small Chair w/Top Bar<br />

Old Style Side Head Support (For Replacement Parts Only)<br />

Side Head Support for Mini Chair<br />

The Side Head Support plates hole either a top plate of top bar. They are made from 1 inch thick Polycarbonate. These<br />

are standard on most style chairs Except the Audio Chair and Chairs with no head holding system. This system is<br />

designed to hold the head from the top.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


1-CC-10 Top Plate<br />

The Top Plate is also one inch thick Polycarbonate which provides maximum strength and stability for holding the<br />

monkeys head in a fixed position even when the animal is moving around inside of the chair. This is designed for the (6-<br />

FHC, and 6-FAC) series Head Holder on Chair in Section Six of this catalog. A slot running front to rear and centered<br />

left to right holds the threaded (6-FHC-S2B Top Shaft) used for height adjustment and front to back positioning This<br />

setup allows the Head Holder on Head (6-FHP-S1, S2, S4, S6) to be mounted on the center line of the head. With our<br />

new Head Holder on Chair (6-FAC-) allows the Head Holder on the Head to be positioned slightly off center or the<br />

option of positioning the head at different angles and degrees.<br />

1-CC-10B Top Bar<br />

The Top Bar allows unlimited side-to-side adjustment and five possible front to rear positions, spaced at one-inch<br />

(2.5cm) increments. The (FHB-S) Universal Head Holder on the chair is the standard for the Top Bar options. The<br />

vertical bar extends downward to hold the implant on the head. A cross fitting is used to hold the vertical bar to the top<br />

bar of the chair. The fitting is locked in place by setscrews.<br />

We now have two new options for holding the head using the top bar option. The first option uses a slightly smaller top<br />

bar and holds the vertical shaft by a pinch block instead of the cross fitting. This system is not interchangeable with the<br />

1-CC-10B top bar It requires a different top bar on the chair.<br />

The (FAC) Swivel Head Holder on Head and the 1-CC-10B Top Bar provide a lot of positioning options for your<br />

subject.<br />

TOP PLATES/BARS:<br />

Part Number<br />

1-CC-10<br />

1-CC-10B<br />

1-CC-10B-2<br />

1-CC-10C<br />

1-CC-10-KELL<br />

1-CL-10<br />

1-CL-10B<br />

1-CS-10<br />

1-CS-10B<br />

1-CM-10<br />

1-DDC-9A<br />

1-CSTBM-10B<br />

Description<br />

Standard Top Plate<br />

Universal Top Bar<br />

Universal Top Bar (use with replacement for Hollander Fitting PT.# 6-BHB-RA-1)<br />

Standard Top Plate w/cut out in rear<br />

Standard Top Plate w/ Cut outs front and back<br />

Large Chair Top Plate<br />

Large Chair Universal Top Bar<br />

Small Chair Top Plate<br />

Universal Top Bar for Small Chairs<br />

Top Plate for Mini Chair<br />

Top Bar for Chair<br />

Push Bar Handle for Murray Chair<br />

TOUCH BAR:<br />

Aluminum Touch Bar is used in training and during some types of experiments requiring Eye-Hand responses. Front<br />

panel of the compartment can easily be replaced with a separate panel for other types of investigations.<br />

1-CC-20<br />

Touch bar assembly<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


BASES & TROLLEYS:<br />

1-V50 Chair Base Tall, Metal Frame<br />

Part Number Description Chair Size<br />

1-V50S Tall Base Small Chairs<br />

1-V50 Tall Base Standard size Chairs<br />

1-V50L Tall Base Large Chairs<br />

1-V50M Tall Base Mini Chairs<br />

A box construction style of extruded Aluminum is used for the Chair Base (1-V50).<br />

This Base height is adjusted for each size chair and raises the chair to a level that<br />

brings the eye height of the subject to 47.5 inches (121 cm) from the floor. The width<br />

of the base is 16 inches (40.6cm) and the length from front to rear is 16.5 Inches (42<br />

cm). These dimensions can be changed to suit your setup. The chair is mounted to the<br />

base perfectly centered using two wing thumbnuts. This allows easy removal from the<br />

Base. Chairs with the Sliding rear door “Guillotine type door” the chair is often shifted<br />

to the rear of the base instead of centered to allow easier loading and unloading of the<br />

subject. All Tall Bases come with 5-inch locking, non-conductive swivel casters. There<br />

are many chair positioning options available for this style base. (Also see chair<br />

positioners below.)<br />

1-V60 Transport Trolleys:<br />

Trolley shown with chair positioner Sold Separately<br />

Part number Description Chair Size<br />

1-V60S Trolley Small Chairs<br />

1-V602 Trolley w/ 2” wheels Standard size Chairs<br />

1-V602ISO<br />

Trolley w/ 2” wheels Standard size Chairs<br />

for Isolation<br />

Chamber<br />

1-V605 Trolley w/ 5” wheels Standard size Chairs<br />

1-V60L Trolley Large Chairs<br />

1-V60M Trolley Mini Chairs<br />

The Trolley is a low Aluminum Platform equipped with 2” swivel castors. This is an excellent choice for transporting<br />

your subject from its cage to the experimental set up, especially when using the Isolation Boxes.<br />

The height from the floor is 6 ¼ inches it can be increased or decreased to make it level with your test chamber. The<br />

trolley comes with 5” locking wheels however 3” and 2” non-locking wheels are available please specify when ordering.<br />

The Chair is held firmly in place with 2 cam action vertical clamps.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


When ordering a transport trolley that will be used in conjunction with an isolation chamber, please notify us so that we<br />

can adjust the height of the transport trolley to match the height of the isolation chamber.<br />

There are various positioning systems available for the trolley:<br />

(1-V65) will position the chair on the trolley in the same fashion as the tall base using two studs and wing nuts to center<br />

the chair on the trolley.<br />

(1-V-77A) Positioner for Isolation Chambers sees Positioners<br />

FLOOR POSITIONERS:<br />

Floor Positioners fix and position your chair in the experimental set up. All bases are designed to fit the Chair Floor<br />

Positioner (1-V70, -76). Switching from one chair size to another requires no change in your lab setup. For models<br />

using Trolleys or for set ups in Isolation Boxes, the Positioner is the (V77) Series.<br />

1-V-70 Standard Chair positioner<br />

Our most popular chair positioning system consists of two<br />

assemblies. The (1-V-70A) this is the floor or wall mount<br />

assembly, and (1-V-70B) Chair base assembly. The Chair is<br />

positioned by two buttons and locked in place with a Latch Block.<br />

Space requirements length 18 ½ inches (47cm). Distance from chair<br />

base to end of diagonal bars 15”(38 cm) to 20” (51 cm) depending on<br />

angle of support.<br />

Figure 1-6 Standard 1-V-70 positioner<br />

New Option available for the Standard floor<br />

Positioner<br />

This option is available for the standard type Floor positioner<br />

on the tall base or trolley. It incorporates three latches for<br />

extra stability for overly active monkeys.<br />

1-V-73-3<br />

Slide plate floor positioner<br />

This positioner takes up less room than the 1-V-70 positioner. Three “L”<br />

shaped legs or slide plates (1-V-73B) mounted on the chair base (1-V50) . A<br />

fourth leg can be added for extra stability for overly active monkeys. The foot<br />

slides up for moving the chair to and from the caging area. The foot of the<br />

slide mates with the studs in the floor plate (1-V73A) and held by knobs. The<br />

Floor Plate (1-V73A) has a beveled edge making it easier to roll the chair into<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


position The floor plate increases the eye height by ¼ inch (3/4 cm). The floor plate can be omitted<br />

by mounting the studs in the floor. It becomes harder to see the studs in the floor mounted in this<br />

manner, and harder to move the setup.<br />

V-76 Center Post Positioner for Chairs<br />

Permits Chair to rotate 360 degrees and be locked into any position around the<br />

center post “Z” axis. It is equipped with a protractor around the center post<br />

with a pointer for easy positioning. Frequently used in peripheral vision<br />

experiments.<br />

NOTE: It is recommended that the decision to use the Center Post<br />

Positioner be made at the time of the Chair order, as the base requires<br />

modifications to accommodate installation and use.<br />

1-CC-BAG<br />

Canvas Chair <strong>Co</strong>ver:<br />

Our Canvas Chair <strong>Co</strong>vers are for covering the Chair while transporting the monkey through sensitive areas (Public<br />

areas). We have a style to fit your chair. Our Canvas <strong>Co</strong>vers can also be ordered with a metal frame for extra support.<br />

This option adds about 15 pounds of weight to the cover.<br />

Part Number<br />

1-CCP-BAG<br />

1-CCA-BAG<br />

1-CCT-W-BAG<br />

1-CLP-BAG<br />

1-CLA-BAG<br />

1-CL-W-BAG<br />

1-CS-BAG<br />

1-CSA-BAG<br />

1-CS-W-BAG<br />

Description<br />

Standard Chair with no Options<br />

Standard size chairs with Audio Post Option<br />

Standard size Chairs with Wings (coil supports)<br />

Large Chair with no options<br />

Large Chair with Audio Post<br />

Large Chairs with Wings<br />

Small Chairs with no Options<br />

Small Chairs with Audio Posts<br />

Small Chairs with Wings<br />

NOTE: Other canvas covers can be manufactured to correspond with other types of chairs with<br />

different specifications. Please supply a description of the chair for accurate sizing.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


VPCK0A<br />

Solid Transport <strong>Co</strong>ver for Primate Chair:<br />

The solid Transport Box is a more secure way of transporting the Primate in the Chair than the Canvas <strong>Co</strong>vers. The<br />

chair is placed inside the box and clamped into place. The box comes with double doors front and rear. This makes<br />

loading easier. It comes with five-inch Locking wheels and the floor height matches the Travel Trolleys (1-V60). The<br />

cover is developed on an aluminum framework and covered with opaque white Lucite. The Size of the box is 28<br />

inches (71 cm) wide with a twenty-six inch door opening. The box is twenty inches deep and Forty-four and one half<br />

inches tall. Modifications are available to meet individual needs. Made to fit all sizes of chairs.<br />

Part Number<br />

Description<br />

1-VPCKOA-CCO<br />

Standard Transport Box<br />

1-VPCKOA-CUSTOM<br />

For ordering custom boxes<br />

1-VPCKOA-SLIDE<br />

Box with sliding door<br />

1-VPCKOA-INS<br />

Box with Insulated Sides<br />

PICTURED 1-VPCKOA-SLIDE<br />

1-VPCKOA-CCO<br />

VPCT<br />

Hydraulic Lift Table with Smooth Plastic Top:<br />

This lift table will raise the level of the chair from approximately 8.3 inches above the floor to approximately 29<br />

inches. Overall platform size is 28 x 17-1/2 inches. Top is plastic finished for easily sliding chairs into the<br />

experimental set up. The chair, minus a base or trolley, can be clamped securely for transport to and from the<br />

laboratory to the housing area. In some instances this transport can be incorporated into the experimental set-up.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


1-Spare Parts<br />

Section 1 CHAIR PARTS<br />

Part No. Price <strong>Co</strong>mponent Name & Parts Parts Total<br />

per<br />

set<br />

1-KNOB-NP $8.30 Neck Plate Cross Knob ea 1<br />

1-KNOB-R1.5 $6.00 Perch or Waist Rest. Knobs w/Studs 1<br />

HK-CL-1A-PPK-1 $3.63 ea Waste Tray Cross Knobs 1<br />

1-DHS-20 $17.50 each Door Hinge wo/Screws<br />

1<br />

(un-drilled )<br />

1-CC-16H $61.27 set Standard Hinge pre drilled<br />

w/mounting hardware hinge for<br />

standard chairs<br />

1-CC-16H<br />

Screws, 12 ea. 8-<br />

32 x 7/8” PH<br />

1-CC-10-WS $27.10 each Welded Cap Screws for Top Plate<br />

1<br />

(4 needed per chair)<br />

1-CC-10B-WS $27.10 each Welded cap Screw for Top Bar<br />

(2 Needed per chair)<br />

1<br />

1-ANB3 $36.80 set Chair Base Screw Set Button Head<br />

Screws<br />

20<br />

Double T Nuts 10<br />

Single T Nuts 10<br />

1-CC-16SA $158.70 <strong>Co</strong>mpression Latch w/Screws Set and <strong>Co</strong>mpression<br />

Extrusion<br />

Latch<br />

1<br />

<strong>Co</strong>mpression<br />

Latch Hook<br />

1<br />

Screws, 4-40 x<br />

1/2”<br />

2<br />

Screws, 4-40 x<br />

3/8”<br />

2<br />

1-CC-16A 2<br />

1-CS-5LOKSQ $238.83 set 5” locking wheels for V50 chair base Casters, 5”:<br />

Locking<br />

4<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Section 2 – Animal Handling<br />

SafeWrangle<br />

Animal Guide<br />

The SafeWrangle Animal Guide, developed by <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>., Inc. has been said to be one of the safest devices<br />

on the market for handling your primate. One of the most important safety features is inherent to the ergonomic design of<br />

the handle. As opposed to a straight pole, which can easily slip out of the lab technician’s grip, the pistol grip provides<br />

better control of the animal because it allows the lab technician to hold the pole more securely. The automatic thumb<br />

safety latch, which is unique to our design, provides a secure latching mechanism that straight pole designs do not<br />

provide. Once the primate’s collar is securely attached to the stainless steel hook at the end of the pole, the safety latch<br />

prevents accidental release. Only after the release of the safety latch can the pole be removed from the collar. The<br />

distinctive safety mechanisms of this rugged heavy wall metal pole allow for easy operation with one hand and effective<br />

control of the animal from a safe distance. Our monkey poles are designed for use with the collars listed below, as well<br />

as many brands of collars. Our standard model SafeWrangle is available in lengths of 36 inches (91.5 cm) and 24<br />

inches (60.9 cm). Custom lengths are available upon request.<br />

2-SWAG-36<br />

2-SWAG-24<br />

36” Pole<br />

24” Pole<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Animal <strong>Co</strong>llars<br />

Our <strong>Co</strong>llars are durable, washable, and include an extra link for quick and easy disconnection. They also come with a<br />

replaceable rubber covering for added comfort. The collars are especially recommended for use with the HMP-02 poles.<br />

2-HCM-S<br />

Monkey <strong>Co</strong>llar, Small<br />

• 9 1/2 inches (24.3 cm).<br />

2-HCM-M<br />

Monkey <strong>Co</strong>llar, Medium<br />

• 11 1/2 inches (29.2 cm). (Recommended for most primates weighing 6 to 9 kilograms).<br />

2-HCM-L<br />

Monkey <strong>Co</strong>llar, Large<br />

• 13 1/2 inches (34.3 cm).<br />

The Dura<strong>Co</strong>llar<br />

We’ve made the safest and most<br />

<strong>Co</strong>mfortable collar even more<br />

Durable to increase its service life.<br />

It’s one of the ways<br />

<strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>mpany<br />

Helps s-t-r-e-t-c-h your<br />

research budget<br />

Resists corrosion<br />

New, more durable material<br />

Easy-access hook ring<br />

360° capture (when used with our<br />

Safe Wrangle Animal Guide)<br />

<strong>Co</strong>mfort-engineered<br />

Slim, contoured design<br />

Standard models are available<br />

in these popular sizes:<br />

Large: 14 ¼"<br />

Medium: 12"<br />

Small: 10 ½"<br />

Xtra Small: 9”<br />

Xtra Xtra Small 7 ½"<br />

Custom lengths are also available.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Section 3- Microdrives & Related Equipment<br />

Figure 3-1 Micro Recording Syringe<br />

3-MRM-S02<br />

Recording Micro Syringe<br />

The Recording Micro Syringe injects and records simultaneously from the electrode contained within the syringe barrel.<br />

It was designed by “Chuck” <strong>Crist</strong> to bring about the placement of lesions in an extremely accurate area of cells.<br />

Recordings are made prior to, during, and after injections to verify the effectiveness of the lesion. This unit is packaged<br />

in its own plastic case and includes three recording needles and one matching Hamilton Syringe barrel. The needle size<br />

of the Micro Recording Syringe is 28tw gauge.<br />

SUGGESTED PROCEDURE:<br />

Fill syringe body before attaching to electrode needle. Then attach needle and force fluid through. Repeat this until<br />

fluid shows at the tip. This should take about 10.17 micro liters of fluid to fill the needle Refill syringe body one more<br />

time equal to or more than you intend to inject. You are now ready to assemble and insert into the brain. Attach syringe<br />

body to electrode needle. Attach assembly to your electrode manipulator-drive. Position the electrode needle above the<br />

guide tube into the brain. Care must be taken not to bend the tiny electrode wire as it is lowered into the guide tube.<br />

Any bend in the electrode wire will render the device inoperative or, at least, inaccurate. Once the electrode is safely in<br />

the guide tube, you can attach the lead for the electrode part of the system. Use a miniature alligator clip and attach to<br />

the tube at right angles to the cannula. This completes the electrode circuit. You are ready to proceed with your normal<br />

recording procedures to select a site for the injection. When the site is chosen, inject the desired volume of fluid.<br />

Depending on what you have injected, the response should be almost immediate.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


MICRODRIVE MOUNTING ADAPTERS<br />

3-MMK-A1<br />

X - Y Stage with Kopfâ Microdrive Mounting Adapter<br />

Our X-Y Stage is designed to be compatible with Kopf <strong>Instrument</strong>â microdrives with the <strong>Crist</strong> <strong>Instrument</strong> grid system.<br />

(See section 6 for grids and adapters.) The base is designed to fit the grid adapter (smoke stack). Using the X and Y<br />

lead screws the X - Y Stage moves the electrode into position above the guide tube with the guidance of a vernier scale.<br />

A vertical post supports the Kopfâ adapter and is graduated in easy to read millimeter increments to measure the coarse<br />

movement of the entire microdrive. When the adapter has been locked, the normal hydraulic movement would be<br />

effective in driving the electrode. The adapter supports the standard Kopfâ hydraulic microdrive.<br />

Fig. 3.7<br />

X-Y Stage Chamber and Grid Assembly<br />

Figure 3.4 X - Y Stage with Kopfâ Microdrive Mounting Adapter<br />

3-MMK-A2<br />

X - Y - Z Stage with Kopfâ Microdrive Mounting Adapter<br />

This is the 3-axis model designed for the Kopfâ microdrive. This model is almost identical to the MMK-A1, except it<br />

has a lead screw driven” Z” axis.<br />

3-MMN-A1<br />

X - Y Stage with a Narishige Microdrive Mounting Adapter<br />

This is the 2-axis model designed for the Narishige hydraulic drive microdrive. This X - Y stage is identical to the<br />

MMK, but the stage adapter is designed to fit the Narishige hydraulic drive microdrive Model MO-95.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


3-MMN-A2<br />

X - Y - Z Stage with the Narishige Microdrive Mounting Adapter<br />

This is the 3-axis model designed for the Narishige hydraulic drive microdrive. It is almost identical to the MMN-A1,<br />

except it has a screw driven “Z” axis.<br />

Fig. 3.5 X-Y Stage Positioner Ring<br />

3-MNJ-S01<br />

X - Y Stage Positioner Ring<br />

This positioner ring is compatible with the Narishige X - Y Stage, as well as the <strong>Crist</strong> <strong>Instrument</strong> X – Y stage. The ring<br />

fits on the grid adapter/positioner with a double groove top and is used when absolute repositioning of the X - Y Stage is<br />

required. It is to be used with our Guide Tube Support advancing device for random sampling. See Figure 3.5. This<br />

Positioner Ring can also be used with a Chamber with a double groove.<br />

3-MGS-AH23<br />

Guide Tube Support<br />

This guide tube support is compatible with the above, modified Narishige<br />

microdrive, which has a larger opening in the plastic platform for general use<br />

with our grid system. The guide tube support should be used in preliminary<br />

searches of general areas. This search should allow you to locate a specific area<br />

from which you intend to do chronic recordings. The MGS-AH23<br />

accommodates a 23-gauge guide tube. In the case that other size guide tubes are<br />

used, the device has a replaceable holder that can be made to your<br />

specifications. The MGS-AH23 will come with the standard 23-gauge holder<br />

unless you specify otherwise. Fig. 3.6.<br />

3-MNJ-P02-M<br />

Modification of Narishige Microdrive - Plastic Base<br />

The Narishige MO 95 top plastic platform must be enlarged in order to see the Guide Tube openings and to facilitate the<br />

passage of the electrode into Guide Tube. This modification requires you to send us your top plastic platform. See Fig.<br />

3.7.<br />

3-MNJ-05M-xx<br />

Modification of Narishige Microdrive - Tubing<br />

This modification extends the distance between the work site and the control site by extending the tubing up to 25 feet of<br />

hydraulic line. When ordering, please specify the length of tubing you require. (This does not include the modification<br />

of the plastic base.) CAUTION: Due to the longer length of Teflon tubing, you may expect some increase in hysteresis.<br />

We therefore recommend that you keep your tube length as short as possible. This modification requires you to send<br />

us your Narishige MO 95.<br />

3-MNJ-MSET<br />

Modifications of Narishige Microdrive - Plastic Base & Tubing<br />

Save time and money by having both modifications done at the same time.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


MICRODRIVES<br />

Miniature Microdrive<br />

3-NRMD<br />

This unit is designed for a multitude of uses. One possibility is to attach it inside the standard or the offset grid. Other<br />

possibilities include inverting the grid and attaching one or more microdrive units with a long guide tube, or attaching it<br />

to the new grid cap. The base on this microdrive is available in three configurations: offset right, offset left, or inline<br />

symmetrical. This miniature unit should be mounted inside of a chamber, preferably with our grid having one millimeter<br />

spacing.<br />

PROCEDURE<br />

The microdrive is assembled into the grid by pushing the position pin into one of the holes of the grid. The 000 selftapping<br />

screw is inserted through the hole, as indicated, and is screwed into one of the holes in the grid. The guide tube<br />

is pressed into the grid in a position that lines up with the slot in the front of the moving carrier. The electrode is then<br />

gently inserted into the guide tube and allowed to lower itself by its own weight until it rests on the dura. The electrode<br />

is then pressed gently into the slot and glued in place (we recommend Duco Cement or thick Crazy Glue) and allowed to<br />

dry. When removing the electrode use acetone to dissolve the glue. The electrode will advance 0.25 mm each time the<br />

screw is fully rotated 365°.<br />

This microdrive will also fit onto the new miniature grids for very<br />

small animals. These microdrives can be arranged to place as many<br />

as four in a standard monkey grid. In addition, the microdrives are<br />

available to each hold one, two or three electrodes. Order as<br />

follows:<br />

Figure 3.8 Minature Microdrive inside Standard Grid<br />

Asymmetric Foot Placement<br />

3-NRMD-A1-R<br />

3-NRMD-A1-L<br />

3-NRMD-A2-R<br />

3-NRMD-A2-L<br />

3-NRMD-A3-R<br />

3-NRMD-A3-L<br />

1 Right Electrode Holder<br />

1 Left Electrode Holder<br />

2 Right Electrode Holder<br />

2 Left Electrode Holder<br />

3 Right Electrode Holder<br />

3 Left Electrode Holder<br />

Symmetric Foot Placement<br />

3-NRMD-S1<br />

3-NRMD-S2<br />

3-NRMD-S3<br />

1 Electrode Holder<br />

2 Electrode Holder<br />

3 Electrode Holder<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


3-MRI-1<br />

New all plastic manual MicroDrive<br />

These Microdrives are 100 % MRI compatable are are very similar to the (3-NRMD serries ) These only come in a 3<br />

electrode Model.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


BIELA MANUAL MICRODRIVES<br />

The Biela Rat Microdrive was designed for use in short<br />

term or chronic experiments. The Biela Microdrive<br />

operates manually and consists of a chamber that is<br />

mounted on the head, the body, the thimble and a cap to<br />

be used when the Microdrive is removed from the<br />

animal’s head. The main feature is that the electrode does<br />

not turn when you rotate the thimble. The chamber is<br />

attached to the skull using accepted surgical procedures.<br />

This chamber is threaded on the outside with a #8-64<br />

right hand thread. The body screws on to the chamber.<br />

The Electrode is inserted into this unit and moves<br />

smoothly through the layers of tissue in a linear direction.<br />

There is a cap and plug to put in place when the<br />

Microdrive is not in use. When the cap and plug are<br />

removed the threads on the chamber are exposed. There<br />

is a short piece of Teflon tubing that fits inside the chamber that acts as an insulator and helps to align the drive with the<br />

chamber. This Microdrive is available in three lengths of travel, the 9mm, 14mm and the 23mm. The overall length of<br />

the 9mm Biela Microdrive is 18mm when closed and the 14mm is 24mm when closed. These units will accept an<br />

electrode up to one (1) mm in diameter, thus allowing for the investigator to use single or multi-electrodes. The Inner<br />

Chamber is designed to support four (4) glass micro-pipettes drawn to a fine tip.<br />

PROCEDURE<br />

To place one of these Microdrives into use, follow the ensuing procedures. Open the<br />

Microdrive to its longest length, being careful not to disassemble the thimble and body.<br />

By hand insert the electrode through the center of the Teflon tube at the top. With the<br />

point of the electrode resting on the durra, apply a small drop of duco cement. It is<br />

important to be extremely careful and not allow any of the cement to come in contact<br />

with the functioning units at the top of the spindle. An alternate method for holding the<br />

electrode is to use a very small piece of shrink tubing to hold the electrode and the top<br />

end of the non rotating barrel while driving the electrode below the dura. All threaded<br />

and moving parts should be lubricated with a very small amount of lanolube to assure<br />

smooth and repeatable movement.<br />

3-MMB-1<br />

Biela Microdrive Set, Miniature 9mm<br />

The miniature, manually driven microdrive is designed for use on mice and rats. The Biela Microdrive design is unique<br />

since it is a manually rotated device that moves the electrode along its axis without rotation. The set includes the<br />

Microdrive, 3 mounts with caps, and a set of tools<br />

3-MMB-2<br />

Biela Microdrive Set, Small 14 mm<br />

The small, manually driven microdrive is designed for use on rats and other small animals. The set includes the<br />

microdrive, 3 mounts with caps, and a set of tools.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


3-MMB-3<br />

Biela Microdrive Set, Medium 23 mm<br />

The 23 mm microdrive with its longer length of travel is expected to be available in early 2007. It is operationally the<br />

same as the Miniature and the Small travel lengths to achieve deeper penetration levels.<br />

3-MMB-SF<br />

Biela Microdrive & Foot<br />

This system anchors the Biela Microdrive into the grid, mounting the miniature microdrive inside the grid cup for long<br />

term chronic studies. Use of the Microdrive in this manner requires special caps for added clearance inside the chamber.<br />

This setup can be utilized with either the 9mm, the 14mm or the 23mm size microdrive. The set includes one miniature<br />

microdrive, one mounting foot, one 000 screw and one guide tumbe up to 60 mm. When ordering specify 3-<br />

MMB-SF-9 for the small size or 3-MMB-SF-14 for the 14 mm unit or 3-MMB-SF-14 for the 23 mm unit.<br />

3-MMB-1D<br />

3-MMB-2D<br />

3-MMB-3D<br />

Biela Microdrive, 9 mm (Microdrive Only)<br />

Biela Microdrive, 14 mm (Microdrive Only)<br />

Biela Microdrive, 23 mm (Microdrive Only)<br />

3-MMB-CM Biela Microdrive, Mount & Cap<br />

One Mount and One Cap included in this item. Fits both the 9 mm & the 14 mm microdrive.<br />

3-MMB-C4 Microdrive Cap<br />

3-MMB-M4<br />

Microdrive Base (Mount)<br />

3-Spare Parts<br />

3-MMB-Tool Biela Microdrive Tool Set<br />

<strong>Co</strong>ntains one each large and small blade tool<br />

3-MMB-STS Stereotaxic Support for Biela Microdrive<br />

The Stereotaxic holder is designed for use when the subject animal is in a stereotaxic device and the normal cranial<br />

holders are not used. The device can be used in this manner with or without the guide tube. If the guide tube is used<br />

you will need a guide tube pressure plate that is a part of the foot.<br />

Section 3 Microdrive Parts<br />

Biela Microdrive<br />

3-MMB-SP1 Inner Sleeve Tubing for -<br />

MMB-1, 2 or 3<br />

3-MMB-SP0<br />

3-MMB-CSP4<br />

Outer Sleeve Tubing for<br />

- MMB-1, 2 or 3<br />

Microdrive Cap Plug<br />

Rod<br />

3 ft. lengths<br />

(91.44cm)<br />

3 ft. lengths<br />

(91.44)<br />

5-3/4 in.<br />

(15cm)<br />

lengths<br />

Lubricant<br />

ZGM-LANO 1 Tube Lubricant Approx. 2 oz.<br />

(59.147ML)<br />

3-MDRV-14 Microdrive Foot Each 1<br />

FS-000x5/32 000 Self Tapping Screw 3 each 3<br />

1<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


CRIST INSTRUMENT CO., INC.<br />

Section 4 – Touch Panels and Interactive Devices<br />

Figure 4.1<br />

Touch Panel Module (4-TPS-E1)<br />

4-TPS-E1<br />

Touch Panel Sensor Module<br />

The 4-TPS-E(x) touch panels are contact sensitive devices designed to activate when a grounded primate touches<br />

it. Attaching one side of the device’s electronics component to the primate chair’s metal perch, then attaching the<br />

other side of the device to a rod (that is easily reached by the primate) achieves the grounding of the primate.<br />

When contact is made, the “normal” output will give a “positive logic” TTL signal. The “invert” output will give<br />

a “negative logic” TTL signal. The signal can then drive another device – like <strong>Crist</strong> <strong>Instrument</strong>s “5-RLD-E(x) or<br />

D(x)” Reward Systems, or it can be sent to the I/O Module in your computer. If your computer is running an<br />

interactive program, e.g. LabVIEW or TestPoint, etc. It will sense the TTL pulse. From there, one can process the<br />

signal, or drive a device like the reward system. For this configuration the outputs will produce a pulse with the<br />

duration is equal to the time the subject is touching the metallic rod or pushing the button.<br />

4-TPS-E2<br />

Touch Panel, Short Duration Module<br />

This Touch Panel is identical to the 4-TPS-E1 except that it is designed to send a short duration pulse. This pulse sends<br />

either a positive (normal) or negative (invert) TTL signal to the computer when the animal touches the sensor bar or a push<br />

button. Like the TPS-E1, the unit’s sensitivity is adjustable. In this configuration the outputs will produce a fixed pulse of a<br />

factory-preset duration. This time is preset to 1/3 second; but can be changed by request at the time of purchase.<br />

<strong>Crist</strong> <strong>Instrument</strong><br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

1<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


CRIST INSTRUMENT CO., INC.<br />

SwivElectra<br />

The SwivElectra, also known as an electrical swivel, or commutator, is<br />

a high-precision instrument. It allows a subject to move freely within its<br />

environment, while keeping multiple electrical recording/stimulation channels<br />

untangled. SwivElectra has continous bi-directional rotation. Available in<br />

up to 36 Channels.<br />

SwivElectra commutators work well when recording EEG or neural signals in studies where subjects are awake and active.<br />

Wires connect between the commutator and the electrodes on the subject. The commutator swivels freely with the animals<br />

movements preventing wires from tangling. When mounted in the ceiling of the testing chamber it permits continuous full<br />

rotation in any horizontal direction.<br />

Rotation is achieved with the use of extremely free running bearings. Torque is approximately .05 inch ounces per channel.<br />

Current is rated at 1 amp per ring. Noise levels for most of our slip<br />

rings show changes in contact resistance of approximately .005 ohms.<br />

When a “run-in” period is used, this level of resistance is usually<br />

reduced. Some “run-in” is generated prior to shipment. To achieve the<br />

best results “run-in” should be completed in the actual environment<br />

where it will be used. Dual contacts on gold slip rings allow for<br />

minimal noise in the transmission of data.<br />

When it is desired to dispense fluid to the subject a cannula may be fed<br />

through the rings of the commutator. At the time of ordering, please let<br />

us know what size tube you need to have installed. SwivElectra<br />

commutators are available in sizes ranging from 9 channels to 80<br />

channels. The output connections on this commutator are sub D<br />

receptacles. <strong>Co</strong>nnectors are available in 9 pins, 15 pins, 25 pins, and<br />

44 pins.<br />

Figure 4-2<br />

<strong>Co</strong>mmutators<br />

4-TBC-9S<br />

SwivElectra <strong>Co</strong>mmutator, 1 to 9 Channels<br />

The 9-channel version of the SwivElectra <strong>Co</strong>mmutator is the smallest unit with the least amount of torque. It has an<br />

extremely free moving rotation suitable for small animals. Two female 9-pin Sub D Receptacles are provided on the 4-TBC-<br />

9S. Cabling and connectors to your data collection equipment are not provided, but are available upon special request.<br />

When ordering cable and connectors, please specify the length of cable and the type of connector required to attach to your<br />

equipment. See Figure 4-2, left side.<br />

4-TBC-9-LT<br />

SwivElectra <strong>Co</strong>mmutator - with Cannula for Liquid Tube<br />

This product operates in the same manner as the 4-TBC-9S. However, this unit is made from the larger 4-TBC-25<br />

commutator to accommodate the addition of the cannula through the center of the unit. This commutator also includes the<br />

same 9-pin connectors as the above unit.<br />

2<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


CRIST INSTRUMENT CO., INC.<br />

4-TBC-25<br />

SwivElectra <strong>Co</strong>mmutator, 18 to 25 Channels<br />

This product operates in the same manner as the 4-TBC-9S. This is a larger unit than the 4-TBC-9S. The torque ratio is not<br />

quite as free as in the 9-pin due to the increased number of rings and brush blocks, but, all 25 pins can be used for data<br />

transmission. Two 25-pin receptacles are provided on the 4-TBC-25. See Figure 4-2 right side.<br />

4-TBC-25-LT<br />

SwivElectra <strong>Co</strong>mmutator - with Cannula for Liquid Tube<br />

This product is the same as the 4-TBC-25, except with the addition of the cannula.<br />

4-TBC-36<br />

SwivElectra <strong>Co</strong>mmutator, 26 to 36 Channels<br />

This product is that same as the 4-TBC-25, except a different connector (44-pin) is used to accommodate more channels.<br />

4-TBC-36-LT<br />

SwivElectra <strong>Co</strong>mmutator - With Cannula for Liquid Tube<br />

This product is the same as the 4-TBC-36, except with the addition of the cannula.<br />

SLICE CHAMBERS<br />

4-BSC-4<br />

Tower Biela Slice Chamber<br />

The Biela-style slice chamber is used to maintain and promote slices of tissue in a warm, moist, oxygenated atmosphere.<br />

There are four separate slice chambers with a central oxygen distribution tower. Each tissue chamber is provided with a fluid<br />

supply and siphon to prevent overflow. Additionally, the chamber has a grounding loop in the bottom. The slice itself is<br />

supported on a special mesh that allows circulation of a nutrient rich fluid. The temperature of the entire chamber is<br />

controlled by a submerged heating element and a thermister that senses the temperature. Slice chambers with different<br />

numbers of towers can be provided upon request.<br />

At the present time we do not provide the electronics controls or pumps.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

3<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


CRIST INSTRUMENT CO., INC.<br />

AUDIO STIMULATORS<br />

4-TAS-FAR<br />

Fixed Angle Rotary Audio Stimulator<br />

This device is designed to provide audio signals that originate equidistant from the center of the subject’s head via a<br />

curvilinear arm. This arm supports the speakers and is suspended from above rotating a full 360 degrees around the animal.<br />

The angular vertical positioning is fixed at angles dependent on the speaker size and number. The speakers are activated<br />

from a preset controller that allows each speaker to be independently selected, thereby providing a known position. It can be<br />

built to fit either in an anechoic chamber or other laboratory space. A minimum of six feet of vertical height is required.<br />

This product is built to order, allowing for customization.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

4<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


CRIST INSTRUMENT CO., INC.<br />

4-TAS-VAR<br />

Variable Angle Rotary Audio Stimulator<br />

Similar to the 4-TAS-FAR, this device is designed to provide audio signals that originate equidistant from the center of the<br />

subject’s head. The arm supports a single movable speaker, which is moved up and down permitting infinite and accurate<br />

positioning. The movement of the speaker is computer controlled; therefore, a single or multiple set(s) of positions can be<br />

preprogrammed and consistently repeated. Other than the movable vertical control of the speaker, this device performs<br />

exactly as the 4-TAS-FAR. This product is built to order, allowing for customization.<br />

CUSTOM INTERACTIVE EQUIPMENT<br />

Vestibular Platforms<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

5<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


CRIST INSTRUMENT CO., INC.<br />

4-VP03<br />

BODY ROTATIONAL VESTIBULAR PLATFORM<br />

This unit is designed to rotate the body while holding the head stationary. The rotational axis of the chair passes through the<br />

rotational axis of the neck allowing 40 degrees rotation to the left and the right without harming the neck of the subject. If<br />

the animal resists a sensor shuts down the experiment and the subject will receive no reward. Rewards will be given when<br />

the computer is satisfied that a complete cycle has been accomplished. <strong>Co</strong>mputer parameters are set by the investigator. We<br />

suggest the use of National <strong>Instrument</strong>s Lab View as the operative platform. In addition, this chair can be modified to hold<br />

the chair in place while rotating the head or it can also be used in standard vestibular experiments where the head and the<br />

animal are swung back and forth or rotated 180 degrees. Call us for further details or customization to your exacting needs.<br />

4-VP02<br />

VESTIBULAR SWING APPARATUS<br />

The Vestibular Swing Apparatus swings the subject from side to side approximately 30 degrees in each direction. It can be<br />

used with varying acceleration/deceleration patterns and variety of distances from the center of arc. The apparatus is<br />

designed to support a <strong>Crist</strong> Primate Chair to hold the subject. Call for further details or customization to your exacting needs.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

6<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


CRIST INSTRUMENT CO., INC.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

7<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


CRIST INSTRUMENT CO., INC.<br />

4-DCM01-G<br />

Digital <strong>Co</strong>mpression Monitor<br />

The new Digital <strong>Co</strong>mpression Monitor (4-DCM01-G) is an intelligent device that monitors grip<br />

strength verses time and provides a means to save and / or plot the data. There is also a trigger output for<br />

use with our Reward Systems or PC. The Monitor is composed of three components:<br />

1. Grip Sensor Handle<br />

· Same Grip Handle as used with our Digital Reward System Sensor Interface.<br />

· Range of ~ 20 Mohms (no load) to ~ 60 Kohms (100 lbs).<br />

2. Grip Interface<br />

· Data collection / PC interface module.<br />

· The duration of the data collection can range from 2sec to over 20min.<br />

· A programmable Trigger Output allows connection to our Reward Systems or a PC to facilitate<br />

Training / Data <strong>Co</strong>llection by use of Reward Techniques.<br />

o Reward at User Set Grip Threshold.<br />

o Reward at <strong>Co</strong>mpletion of Data <strong>Co</strong>llection.<br />

o Instant Reward.<br />

3. Grip Monitor GUI<br />

· Designed to operate on a Windows platform under Win 95/98/2000/XP.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

8<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


4-GSI-D1<br />

CRIST INSTRUMENT CO., INC.<br />

SENSOR INTERFACE<br />

The new touch sensor and more!<br />

The new Sensor Interface (4-GSI-D1) is an intelligent device that generates reward triggers to the Digital<br />

Reward <strong>Co</strong>ntroller. It has been designed to work with multiple input devices and to provide data to the controller<br />

in addition to the reward trigger. This device may be used with the previous E(x) series of reward controllers;<br />

HOWEVER, the data reporting and trigger delay features will NOT be functional. This device may also be used<br />

with a PC I/O; BUT the data reporting and trigger delay features will NOT be functional unless the<br />

communications protocol is implemented.<br />

SPECIAL FEATURES<br />

· Easy interface to reward system via standard 6-6 (RJ12) modular phone cable.<br />

· Easy interface to input device via standard stereo audio cable.<br />

· Sensor Interface is powered from the Reward <strong>Co</strong>ntroller through the interface cable. It does not<br />

require any AC source.<br />

· Sensor Interface is designed to work with three different input devices: Switch, Touch bar (or<br />

plate) and a Grip sensor handle.<br />

· The Touch mode has a range of ~ 40 Kohms to ~2000 Kohms.<br />

· The Grip device has a range of ~ 20 Mohms (no load) to<br />

~ 60 Kohms (100 lbs)<br />

· Trigger output may be “On <strong>Co</strong>ntact” (Normal mode) or “On Release” (Invert mode).<br />

· Input device, range and trigger polarity (Mode) are switch selectable.<br />

· Trigger output may be delayed from contact (or release) in increments of 1 second between 0 and<br />

127 seconds, via the reward system GUI.<br />

· For Touch and Grip input devices, trigger threshold may be set by means of a front panel control.<br />

This value is reported to the reward system GUI.<br />

· For the Grip input device, whenever the trigger threshold is met, the maximum and average grip<br />

values are reported to the reward system GUI.<br />

· The new Sensor Interface is mounted in a durable plastic enclosure measuring only 2 by 3 by 5<br />

1/4 inches.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

9<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Section 5 – Reward Systems<br />

Fig. 5.1 <strong>Co</strong>mplete Liquid Reward System (5-RLD-E1) - Dispenser Unit<br />

(left), Rack Mount <strong>Co</strong>ntrol Panel (right).<br />

5-RLD-E1<br />

Liquid Reward System- Liquid Dispenser, Rack Mount <strong>Co</strong>ntrol<br />

The original <strong>Crist</strong> <strong>Instrument</strong> Liquid Delivery System consists of a control panel (5-RLD-E1B), a dispenser unit (5-<br />

RLD-E1C), one mouthpiece (sipper tube) (5-RLD-00A) and a 25-foot midi-cable connecting the <strong>Co</strong>ntrol Module to the<br />

Dispenser Module. The rack mounted control panel provides a variety of features designed to dispense various quantities<br />

of reward. This system has two audible, reward dispensing signals each individually controlled from the <strong>Co</strong>ntrol Module.<br />

One audible signal is on the control unit; the other is on the dispenser unit. A reward can be administered by pressing the<br />

reward button, located on the control panel, via your computer, or by the optional remote. The control panel also<br />

supports a connection for the optional operator controlled Remote Dispenser Switch (5-RRC-E0D). The dispenser unit<br />

is designed to hang or sit near the subject in the experimental setup. This is a gravity fed system using a low voltage,<br />

quick acting solenoid. The mouthpiece (sipper tube) attaches conveniently to your <strong>Crist</strong> <strong>Instrument</strong> primate chair. For<br />

additional information see the individual components listed below.<br />

5-RLD-E1B<br />

<strong>Co</strong>ntrol Panel <strong>Co</strong>mponent for Rack Mount Liquid Reward<br />

The rack mounted <strong>Co</strong>ntrol Panel is designed for your computer rack and can be purchased separately. This is the same<br />

unit, which is provided with the RLD-E1, Liquid Reward System, described above. It was originally designed to<br />

dispense liquid rewards from a gravity fed dispenser module. (See 5-RLD-E1C) The rack mounted control panel<br />

provides a variety of features designed to dispense various reward quantities. The features include from left to right: 1)<br />

A Sonalert, 2) Toggle switches to control both the sonalert on the panel and the Sonalert on the dispenser system. 3)<br />

<strong>Co</strong>mputer inputs, one BNC connector and a double banana jack, which also can be used to plug the Touch Panel Sensor<br />

directly to the Reward System. 4) The DIN connector for the dispenser module. 5) A rotary time selection/computer<br />

override switch labeled “TIME (MS)”. This controls the millisecond volume of liquids dispensed per reward dispensing<br />

larger or smaller drops of liquid. 6) The manual red push button reward switch. 7) A remote control double banana jack<br />

input. 8) A front mounted fuse for easy access. 9) An indicator light that signals when the Power is on. 10) The on-off<br />

Power toggle switch. See control panel in Fig 5.1.<br />

NOTE: Due to the lack of availability of some electronic components, this system may be discontinued. See newer<br />

models below.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


5-RLD-E1C<br />

Gravity Fed Liquid Dispenser Unit<br />

This Dispenser Unit works with the Rack Mount Liquid <strong>Co</strong>ntrol Module (5-RLD-E1), the Free Standing <strong>Co</strong>ntrol Module<br />

(5-RLD-E2), the Digital Rack Mount Reward <strong>Co</strong>ntrol Module (5-RLD-D1) and the Free Standing Digital <strong>Co</strong>ntrol<br />

Module (5-RLD-D2). The dispenser comes with its own bottle for liquids, a sonalert activated from the control panel,<br />

and the quick acting solenoid. The normal/drain selection switch is located on the front of the dispenser unit. The drain<br />

switch setting flushes the system for cleaning. All components are mounted on a chemical resin board to facilitate easy<br />

cleaning and sanitizing. This unit is designed to either hang on the wall or to sit on a shelf. When hanging, unscrew the<br />

shelf support from underneath and use the hanger bracket on the back for mounting on the wall. Included with your<br />

order is approximately 6 inches (15.2 cm) of 1/8” (3.3mm) Tygon® tubing and ten feet (3 meters) of 1/16” (1.5mm)<br />

Tygon® tubing to connect to the Mouthpiece.<br />

5-RLD-00A<br />

Mouthpiece (Sipper Tube)<br />

This Mouthpiece (sipper tube) can be used with both our Liquid Reward Systems (5-RLD-E1, 5-RLD-E2, 5-RLD-D1<br />

and 5-RLD-D2). The sipper tube is made from stainless steel tubing with a specially molded, non-toxic mouthpiece. It<br />

is designed to prevent the system from draining through any sucking action on the part of the primate. When the liquid<br />

is dispensed, the droplet will hang just at the end of the sipper tube briefly to permit the subject time to retrieve its<br />

reward. The sipper tube comes with the mounting block and clamp for attaching to the test chamber. We recommend<br />

that a different sipper tube be used with each subject. The delivery tip is 1.5 x 0.5 inches (3.81cm x 1.27cm).<br />

5-RLD-E2<br />

Free Standing Liquid Reward System<br />

This module has the same features as the Rack Mount Liquid Reward<br />

System 5-RLD-E1; however, the control panel components of this<br />

module are enclosed in a freestanding electronics box that can be<br />

placed up to 25 feet (7.6 meters) from the experimental setup. This<br />

Free Standing <strong>Co</strong>ntrol Module uses the same dispenser unit (5-RLD-<br />

E1B) as the rack mounted system. The Free Standing <strong>Co</strong>ntrol feature is<br />

ideal for use with the isolation chamber. Also included is one<br />

mouthpiece (sipper tube) 5-RLD-00A.<br />

Fig. 5.2<br />

<strong>Co</strong>mplete Liquid Reward System<br />

(5-RLD-E2) - Free-standing<br />

<strong>Co</strong>ntrol Module (left), Liquid<br />

Dispensing Unit (right)<br />

5-RLD-E2B<br />

Reward System Desk Top <strong>Co</strong>ntrol Module<br />

The Reward System Desk Top <strong>Co</strong>ntrol Module can be purchased separately. It is specially designed for liquid reward<br />

systems. This module has the same functioning abilities as the rack mounted module, except it lacks an audible reward<br />

signal in the box. It does, however, include the alarm switch, which will sound only from the dispenser unit when the<br />

switch is in the ON position. NOTE: Due to the lack of availability of some electronic components, this system may<br />

be discontinued. See newer models below.<br />

5-RRC-E01-25<br />

Reward System Remote <strong>Co</strong>ntrol<br />

The Remote <strong>Co</strong>ntroller provides the operator more freedom of movement throughout the experimental setup. The push<br />

button remote control comes with a double banana plug that attaches to the front of the control module. The remote<br />

control function allows the operator to administer the reward from a more remote location, using a 20-foot (6m) cord.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


5-RLD-E3<br />

Increased Volume <strong>Co</strong>ntrol System (<strong>Co</strong>mplete System)<br />

The Increased Volume <strong>Co</strong>ntrol System works well with either the liquid or slurry reward systems. When setting the<br />

center dial on the control panel to midrange, 50ms, the increased volume control system increases the liquid/slurry<br />

reward for the primates to approximately 20ml for every 100 times the reward button is pressed. The following table<br />

gives the approximate volume measurements of both the liquid and slurry reward systems when utilizing the increased<br />

volume control system.<br />

Switch Position Dispense Time Volume<br />

20ms 260ms 8ml<br />

25ms 320ms 10ml<br />

30ms 380ms 11.5ml<br />

40ms 500ms 16ml<br />

50ms 640ms 19.5ml<br />

60ms 750ms 23ml<br />

75ms 950ms 28ml<br />

95ms 1180ms 36ml<br />

These volumes were measured while using the standard 10-foot (3m) length of 1/16-inch (1.5mm) hose. The<br />

mouthpiece was 36 inches (91.4cm) below the reservoir solenoid valve, and the excess hose was coiled up at the same<br />

height as the valve. This model is made to order only.<br />

Note: the dispensed volumes, above, may be changed slightly by adjusting the height of the reservoir above the<br />

mouthpiece.<br />

5-RLD-E3-B<br />

<strong>Co</strong>ntroller Only<br />

The Increased Volume <strong>Co</strong>ntrol System <strong>Co</strong>ntrol Module can also be purchased separately. It<br />

functions exactly the same as the control unit in the 5-RLD-E3.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


NEW<br />

5-RLD-D1<br />

DIGITAL RACKMOUNT REWARD SYSTEM<br />

Our NEW digital rack mount universal reward control which is slated to replace the current<br />

Reward System 5-RLD-E1 opens new horizons in reward distribution systems. You will find<br />

a major improvement in its application in your neurophysiological and behavioral<br />

experiments. While generally developed for primate behavioral and neurophysiological<br />

experiments its basic purpose is to deliver liquid or slurry rewards to experimental subjects<br />

performing some kind of operant task; you may discover new data collection abilities as well.<br />

The 5-RLD-D1 comes as the basic unit or with a variety of options.<br />

Unlike the old systems, these new<br />

controllers are now being designed with<br />

microcontrollers for achieving better<br />

computer control. Experience better<br />

records for each of your research<br />

subjects on their liquid intake and for<br />

monitoring and recording the reward<br />

history.<br />

These programmable reward systems<br />

with improved reliability can enable<br />

investigators to perform and manage<br />

their experimental data in an easy and<br />

efficient way.<br />

Flexible, programmed and precise<br />

reward delivery enables new opportunities for conducting neurophysiological investigations into<br />

reward-related systems in the brain and for other behavioral applications involving precise control<br />

over the volume, timing, and type of primary reinforcement.<br />

A few of the salient features of this controller are:<br />

· Sophisticated controller to maximize the flexibility and ease of operation of the entire<br />

new reward system.<br />

· Suitable for experiments that require control of all three features of reward being<br />

delivered: quantity (volume), timing, and preference.<br />

· This new controller acts as a universal controller for all 3 kinds of dispenser units: liquid,<br />

slurry and pressure dispensers.<br />

· Greater precision and control of rewards and capability to produce patterns of rewards<br />

compared to older versions.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


· Crystal controlled AVR microcontroller is employed for improved timings.<br />

· EMI filtering & Easier Voltage selection is done using the AC Entry Module.<br />

· This unit has an optional user-friendly GUI interface (programmed in C-builder), which<br />

can monitor, control, record, develop patterns and save the data collected from the reward<br />

controller via serial RS232 COM port or USB/RS232 converter.<br />

· The optional remote control is now cordless. The wireless RF reward option enables<br />

the user to activate the reward delivery from a distance within a range of 50m using a key<br />

fob.<br />

· This system is designed to deliver reward of volumes as small as 0.05ml and up to<br />

12.75ml.<br />

· Use your <strong>Co</strong>ntroller to drive a customized dispenser for pellets or other devices.<br />

NOTE: When different (thicker or lighter) liquids are used, different viscosity liquids tend to<br />

be delivered at very different rates. The amount of reward dispensed when a water reward is given<br />

for 20 milli-secs will not be same as the amount dispensed for applesauce for that particular time. In<br />

order to have greater control over the volume of rewards dispensed, calibration tables have been<br />

introduced into our controller.<br />

Certain classes of experiments require greater and more careful control of volume and<br />

timing. For such experiments, Optional Volume GUI software is available for an additional price.<br />

It has the capability to store calibration tables and allows the user to deliver rewards of small and<br />

precise volumes. This GUI establishes a sophisticated user interface.<br />

The complete system includes the <strong>Co</strong>ntrol Module, the Dispenser Unit and a Sipper Tube. As<br />

with the 5-RLD-E1, <strong>Co</strong>ntrol Modules, Dispenser Units and Mouth Pieces (Sipper Tubes) may be<br />

purchased separately.<br />

5-RLD-D2<br />

FREE STANDING DIGITAL REWARD SYSTEM<br />

The Free Standing Digital Reward System has a <strong>Co</strong>ntrol Module that can be placed on any desk, lab<br />

bench or shelf and has the same features as the Rack Mount <strong>Co</strong>ntrol Unit. The <strong>Co</strong>ntroller can be<br />

placed up to 25 feet (7.6 meters) from the experimental setup. The Dispenser Unit and the Sipper<br />

Tube included with this system are the same as the Unit in the 5-RLD-D1. This unit is ideal for use<br />

with our Iso-Chamber in Section 8 of our catalog. The same options are available with this unit as<br />

with the 5-RLD-D1 System including the Volume GUI and the Wireless RF with the Key-Fob<br />

activation.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


5-RPD-M1<br />

Pressure Reward System<br />

The Pressure Reward System (5-RPD-M1) is a complete<br />

reward-system compatible for both liquid and slurry type of<br />

rewards. It has been custom made for the research going on<br />

in NIH Laboratory of Systems Neuroscience.<br />

This system is far more accurate than the gravity fed<br />

Reward Systems, as the reward dispensed is pressure<br />

controlled and has all the control parameters set by a<br />

computer, which is interfaced to this system. The 5-RPD<br />

Dispenser is designed to deliver small, precise volumes of<br />

liquid/slurry foods to the research subject (animal). This system overcomes many of the limitations<br />

of earlier dispensers, like susceptibility to suction created by the research subject.<br />

The Dispenser has three components:<br />

Features<br />

5-RPD-M1A02<br />

CONTROL UNIT<br />

User interface, power supply, & connections to computer<br />

RESERVOIR UNIT<br />

Refill bottle, air pressure control<br />

SOLENOID<br />

Mounts near animal and provides the fluid output<br />

· Delivers different fluid volumes under computer control<br />

· Direct selection of reward volume using stored tables for each fluid<br />

· Pressure driven fluid chamber and remote valve operation for precise volume control<br />

· LCD and web user interfaces for easy programming and operation<br />

· Can be programmed to deliver a reward every N seconds.<br />

· <strong>Co</strong>unts rewards<br />

· > 350 ml reservoir capacity<br />

· Handles thick fluids (e.g., apple sauce).<br />

· Microprocessor controller can be easily reprogrammed for new features<br />

It uses a regulated pressure of air for dispensing the slurry/liquid reward. The controller of this system is<br />

equipped with a programmed RCM microprocessor that interfaces to a computer. Hence, it enables you to<br />

select different features from the controller.<br />

This system can be customized for your research requirements. The <strong>Co</strong>ntrol-Unit has Ethernet,<br />

Serial, and Digital Input connections. The Ethernet connection is<br />

used for the Web interface. It also provides the feature of ‘Free<br />

Rewards’, which enables the user to deliver one reward every “N”<br />

seconds. Unlike other dispensers, the solenoid is mounted near the<br />

animal ensuring accurate amounts of reward delivery. Amount of<br />

reward dispensed is controlled by the solenoid. Along with the<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Dispenser Unit, the complete Pressurized Reward System also includes the 5-RPD <strong>Co</strong>ntroller and a<br />

mouthpiece (sipper tube).<br />

5-Spare Parts<br />

1.1.1.1 Section 5 Reward Systems<br />

5-RLD-00A Mouthpiece, with Block for Reward System Sipper Tube 1<br />

Block 1<br />

5-RLD-31119 Reward System Solenoid 1<br />

5-RLD-TUB Tubing 10 Ft. 1<br />

5-RLD-E2C4 <strong>Co</strong>nnector Cable (5 Pin) 25 Ft. 1<br />

5-RLD-BTL Bottle Assembly w/Fittings 1<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Section 6 – Implant/Alignment Devices & Surgical Aids<br />

Stereotaxic Alignment Tool<br />

Fig. 6.1 is shown with the pointer attached. The<br />

stem for this tool is used to hold the SS cap to<br />

position the recording chamber. The Centering<br />

Device shown to the lower right allows you to set<br />

up the manipulators at 0, and to mark the positions<br />

on the skull.<br />

Figure 6.1<br />

Stereotaxic Alignment Tool<br />

Stereotaxic Alignment Tools<br />

Be sure to specify the diameter you require to fit your Stereotaxic holder if it is different than the shank sizes<br />

listed below. Call for pricing of other sizes.<br />

6-YSA-SET1S<br />

Stereotaxic Alignment Tool Set # 1S, Stainless Steel Cylinders<br />

This set includes the following:<br />

• Alignment Tool for Head Holder on head (6-YST-S1A)<br />

• Alignment Tool for Cylinders (6-YSC-S2S)<br />

• Centering Device (6-YST-S3)<br />

• Pointer (6-YST-S4)<br />

• Grid Alignment Tool (6-YSG-S1).<br />

NOTE: If using Head Holder on the head 6-FHP-S6, please specify set 6-YSA-SET6S or if using Head Holder on the head, 6-<br />

FHP-S4, please specify set 6-YSA-SET4S.<br />

6-YSA-SET1M<br />

Stereotaxic Alignment Tool Set #1M, MRI Style Cylinders<br />

This set includes the following:<br />

• Alignment Tool for Head Holder on head (6-YST-S1A)<br />

• Alignment Tool for Cylinders (6-YSC-S2J)<br />

• Centering Device (6-YST-S3)<br />

• Pointer (6-YST-S4)<br />

• Grid Alignment Tool (6-YSG-S1)<br />

NOTE: If using Head Holder on the head 6-FHP-S6, please specify set 6-YSA-SET6M or if using Head Holder on the head 6-<br />

FHP-S4, please specify set 6-YSA-SET4M.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


6-YSA-SET2S<br />

Stereotaxic Alignment Tool Set # 2S, Stainless Steel Cylinders<br />

This set includes the following:<br />

• Alignment Tool for the Head Post (6-YST-S2)<br />

• Alignment Tool for Cylinders (6-YST-S2S)<br />

• Centering Device (6-YST-S3)<br />

• Pointer (6-YST-S4)<br />

• Grid Alignment Tool (6-YSG-S1)<br />

6-YSA-SET2M<br />

Stereotaxic Alignment Tool Set #2M, MRI Style Cylinders<br />

This set includes the following<br />

• Alignment Tool for the Head Post (6-YST-S2)<br />

• Alignment Tool for Cylinders (6-YSC-S2J)<br />

• Centering Device (6-YSC-S3)<br />

• Pointer (6-YST-S4)<br />

• Grid Alignment Tool (6-YST-S1).<br />

6-YST-XXX<br />

Stereotaxic Alignment Tool for Head Holder on Head and Head<br />

Post<br />

The Alignment Tool facilitates the location and alignment of the Head Holder on the Head or the Head Post on the chair.<br />

These tools are required for consistent and repetitive alignment from one animal to another.<br />

Catalog No. Works With Part Name Size Material<br />

6-YST-S1A 6-FHP-S1 Cylinder Type 12.7 mm 8” Long x 8.0 mm Dia Shank 303 Stainless Steel<br />

6-YST-S6A 6-FHP-S6 Cylinder Type 9.5 mm 8” Long x 8.0 mm Dia Shank 303 Stainless Steel<br />

6-YST-S4A 6-FHP-S4 Cylinder Type 7.1 mm 8” Long x 8.0 mm Dia Shank 303 Stainless Steel<br />

6-YSP-S2 6-FHP-S2 Post Style 9.5 mm 8” Long x 8.0 mm Dia Shank 303 Stainless Steel<br />

The Stereotaxic Pointer threads into all the devices, listed above, except for the 6-YSP-S2. The Pointer is used with the<br />

Centering Device 6-(YST-S3) to find the fiducial point for positioning these devices. The 6-FHP-S2 requires a 6-FHP-<br />

SP for this holder and fits on the 6-YSP-S2.<br />

Figure 6.2<br />

Stereotaxic Alignment Tool for Head Holder on Head<br />

(6-YST-S1A), shown with a Head Holder on Head (6-FHP-S1)<br />

6-YSC<br />

Stereotaxic Alignment Tools for Cylinders<br />

The YSC alignment tools are used to position the recording chambers in an absolutely vertical orientation to facilitate<br />

accurate coordinate mapping of cell position. The top of the chamber fits into the cup of the alignment tool and is held by<br />

the three screws. Prior to installation, exact coordinates for the center should be established.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


6-YSC-S2S<br />

The 6-YSC-S2S is intended for use in installing the Stainless Steel Recording Chamber.<br />

6-YSC-S2J<br />

When mounting CILUX adapters, it is preferable to use the 6-YSC-S2J.<br />

If you have the 6-YSC-S2S and wish to mount the CILUX chambers, you can use the adapter on the CILUX chamber,<br />

which will fit the S2S alignment tool.<br />

Catalog No. Works With Part Name Size Material<br />

6-YSC-S2S 6-IAC-S0 /6- IAC-SA-XX Recording Chambers, SS<br />

6-YSC-S2J 6- IAM-J0, 6- ICO-J0, XX Recording Chambers, CILUX<br />

8” (20.32cm) long x 8 mm<br />

Dia Shank<br />

8” (20.32cm) long x 8 mm<br />

Dia Shank<br />

Stainless Steel<br />

Stainless Steel<br />

Figure 6.3<br />

Stereotaxic Alignment Tool for Cylinders,<br />

With a SS Cylinder (6-YSC-S2S).<br />

6-YST-S3<br />

Stereotaxic Centering Device<br />

This device fits between the ear bars and provides a centering setup in your Stereotaxic for aligning the reference for all<br />

manipulators. This is used in conjunction with the Stereotaxic Pointer (6-YST-S4) and/or the 6-YST-S1A, S6A, S4A<br />

series.<br />

6-YST-S4<br />

Stereotaxic Pointer<br />

The Stereotaxic Pointer is made from 303 Stainless Steel. It fits in the end of the 6-YST-S1, or the 6-YSC-S2 if the cup<br />

is removed.<br />

6-YSCT-AF4<br />

Stereotaxic Dual Axis Alignment Pointer<br />

This tool can be placed at compound angles to the skull. Anterior/Posterior and lateral adjustments can be made using<br />

graduations of 2 degrees. The stem portion of this device can be used with the cylinder alignment cup or the pointer<br />

device. It can also be used to mount a Kopf® microdrive on the 8 mm diameter.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Fig. 6.4 Stereotaxic grid<br />

alignment tool, the grid,<br />

and alignment shaft.<br />

6-YSG-S1<br />

Stereotaxic Grid Alignment Tool<br />

The Grid Alignment Tool is used with the 6-YST-S1A to provide accurate Anterior/Posterior alignment when installing<br />

the Standard Grid during surgery.<br />

6-YSG-S2<br />

Stereotaxic Offset Grid Alignment Tool<br />

Use this device with the 6-YST-S1 to provide accurate Anterior/Posterior alignment when installing the Offset Grid<br />

during surgery.<br />

6-YSR-S1<br />

Stereotaxic Grid Alignment Rod<br />

The Grid Alignment Rod includes the plug that fits the 6-YSG-S1 and a 6-inch rod for general alignment of the Grid (6-<br />

YGD-D1 or 6-YGD-J1) on the head while the subject is awake; but held in the chair (Head Holder). Not recommended<br />

for accurate Anterior/Posterior mapping.<br />

X-Y Stage with Chamber and Grid Assembly<br />

3-MMK-A1<br />

3-MNJ-S01<br />

6-YNS-S1A<br />

6-YGD-D1<br />

6-IAC-S0<br />

X-Y Stage<br />

X-Y Stage Positioner Ring<br />

Grid Adapter and Positioner<br />

Grid<br />

Recording Chamber<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


HEAD HOLDER POSITIONERS FOR CHAIRS<br />

Head Holder Positioners for chairs are the connecting devices between the top plate, top bar, or audio post on<br />

your chair and the head holder on the primate subject’s head. This devise limits head movement and arranges<br />

the head in a repeatable position each time the subject is placed in the chair.<br />

Top Plate Top Bar Audio Post MRI Chair<br />

Head Holder Chair Positioners are available in the following four styles:<br />

· Three-Part Head Holder Positioner (6-FHC-Sx) – use this option with chairs that have a top plate<br />

· Universal Head Holder Positioner (6-FHB-Sx) – (two parts) use this option with chairs that have a<br />

top bar<br />

· Universal Head Holder Positioner (6-FHB-S2-Audio)- (two parts) use this option with chairs that<br />

have an audio post<br />

· Head Holder Positioner for MRI Chairs (6-FHD-J9) – use with the horizontal MRI Chair (1-CCM-<br />

CHAIR).<br />

· Swivel Head Holder Positioner (6-FAC-XX-X) – swivel head for use with most style chairs,<br />

including those with top bars, top plates, or audio posts.<br />

Figure 6.6: Swivel Head Holder Positioner (6-FAC-SA)<br />

This adjustable devise allows for a far greater range of positions than<br />

most other head holder positioners. It swivels fore and aft 180°, as<br />

well as side-to-side rotation.<br />

Three-Part Head Holder Positioner<br />

The Three-Part Head Holder Positioner on the Chair (6-FHC-Sxx) is designed to provide absolute<br />

anterior/posterior (A/P) alignment with the centerline of the Chair.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Figure 6-7: 6-FHC-S2CD, Three-part head<br />

holder positioner for use with post style head holders and chairs that have a top plate<br />

The above Head Holder Positioner on the Chair (6-FHC-Sxx)<br />

model consists of three major parts:<br />

· Threaded Top Shaft (6-FHC-S2P)<br />

· Sleeve <strong>Co</strong>upling (6-FHC-S2C)<br />

· Bottom Shafts (four options)<br />

- 6-FHC-S2A (large) – for use with cylinder<br />

style head holders<br />

- 6-FHC-S6A (medium) – for use with cylinder style head holders<br />

- 6-FHC-S4A (small) – for use with cylinder style head holders<br />

- 6-FHB-S2B – for use with post style head holders<br />

The above three parts fit together and function as follows:<br />

The sleeve coupling joins the bottom shaft to the threaded top shaft, providing repeatable positioning and firm<br />

alignment. The four bottom shaft options permit the use of the three-part head holder positioner with a<br />

variety of head holder types and sizes.<br />

Figure 6-8:<br />

6-FHC-S2C<br />

Sleeve <strong>Co</strong>upler<br />

Figure 6-10:<br />

(6-FHB-S2B) Bottom Shaft<br />

for<br />

Universal<br />

Head Positioner, connects<br />

Head Post (6-FHP-xx, series)<br />

with the<br />

The Threaded Top Shaft (6-FHC-S2P) allows for vertical adjustment and eye level alignment. Fore and aft<br />

the slot in the top plate of your primate chair provides adjustment. Measurements for the eye to screen<br />

distance are measured from the front edge of the side head support on your chair. The front edge of the eye<br />

should approximate the plain of the front edge of the two side head supports. See the table below for part<br />

numbers.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Universal Head Holder Positioner<br />

The Universal Head Holder Positioner on the chair (6-FHB-xx) is used on the chairs with a top bar (6-FHB-<br />

Sx) and chairs with an audio post (6-FHB-S2-Audio).<br />

At time of order, please specify whether you will be using a top bar chair or an audio chair. The size and<br />

components of the Universal Head Holder Positioner will vary, depending on the type of chair that will be<br />

used in conjunction with the Universal Head holder Positioning System.<br />

There are two top-bar primate chair models available, both of which are compatible with the Universal Head<br />

Holder Positioning System. The original model (6-FHB-S2) consists of a Hollander cross fitting, which slides<br />

onto the 1.06” (2.69cm) top bar (1-CCx-9B) and secured with setscrews. This allows for rotation, but a<br />

limited amount of tilt, for and aft, of the head. The universal head holder positioner provides fairly accurate<br />

A/P alignment.<br />

The newest model of Adjustable Head Holder Positioners (6-FAC-SA) replaces the Hollander cross fitting<br />

with a top bar positioning block, which is attached to the 1” (2.54cm) top bar of the primate chair. Both the<br />

universal head holder positioners and the swivel head holder positioner attach directly to the block (as<br />

pictured below). The advantage of the using the block, rather than the Hollander cross fitting, is that no<br />

screws are required to hold the block in place. The setscrews of the Hollander cross fitting can cause<br />

indentations in the bar, making repositioning difficult.<br />

Note: The top bar positioning block uses a 1” (2.54cm) diameter top bar, and the Hollander cross fitting uses<br />

a 1.06” (2.69cm) diameter top bar. Both the universal head holder positioner and the swivel head positioner<br />

may be used in conjunction with either the Hollander cross fitting or the top bar positioning block.<br />

Fig. 6.11-6.12: Top view of primate chair with top bar positioning<br />

block and swivel head holder positioner.<br />

The Universal Head Holder Positioner (6-FHB-S2) includes<br />

the following:<br />

· Hollander Cross Fitting or Top Bar Positioning Block<br />

· Universal Top Shaft (a vertical rod, 6-FHB-S2A)<br />

· Bottom Shaft, plus assorted screws and Allen<br />

wrenches that come with the complete assembly. Figure 6-92: Universal Head Holder Positioner<br />

Figure 6-91: 6-FHB-S2A Top Shaft for Universal Head Holder Positioner on the<br />

chair<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


PLEASE NOTE THE FOLLOWING:<br />

· The bottom shaft of this unit can be ordered to fit either the cylinder style head holder on the<br />

head or the head post (post style head holder) on the head.<br />

· The horizontal top bar and the side head support plates are available in the primate chair<br />

section (section 1) of this catalog.<br />

· To ensure that alignment is consistent from animal to animal, the head holders (both post and<br />

cylinder style) must be aligned in surgery using a Stereotaxic frame.<br />

· Universal Head Holder Positioners may also be designed for use with an audio post on a<br />

primate chair (6-FHB-S2-Audio). At the time of order, please specify whether you will be using<br />

a chair that comes with a top bar or audio post. When using the Universal Head Holder<br />

Positioning System in conjunction with an audio chair, neither a Hollander cross fitting nor a<br />

top bar positioning block is necessary. Furthermore, the size of the positioning system is<br />

tailored to the specific type of chair that will be used in the investigations.<br />

MRI Head Holder Positioners<br />

The MRI Head Holder Positioner for primate chairs (6-FHD-J9) is a two-part unit made entirely from<br />

CILUX. Unlike those made from stainless steel or brass, head holder positioners made from CILUX produces<br />

no shadow in MRI imaging. Our CILUX head holder positioners are recommended for MRI use with either<br />

conscious/awake or anaesthetized primates in the MRI only. This unit only attaches to the 6-FHP-J9 MRI<br />

Head Holder on head model.<br />

Fig. 6.13 MRI head holder positioner (positioned on chair) 6-FHD-J9<br />

With MRI head holder (positioned on head) 6-FHP-J9<br />

Adapting <strong>Co</strong>mponents<br />

Listed below are some adapting components, which will enable exchange between the cylinder style and the<br />

universals style head position on the chair.<br />

Note: There are NO exchangeable components with the MRI style head holder positioner.<br />

6-HEAD HOLDER POSITIONERS ON CHAIR:<br />

The following models are designed for use on all chairs with side head supports and top plate or with a top<br />

bar. The head holder positioners allow for vertical adjustment. The design also incorporates a system that<br />

provides absolute rotational resistance. The 6-FHC-S2, 6-FHC-S4, 6-FHC-S6, and the 6-FHB-S2 models fit<br />

standard, small, and large sized chairs. 6-FHC-S5 fits Mini Chairs only.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Three Part Positioners for Cylinder Style Head Holders for Chairs with Top<br />

Plates<br />

Part Number Product<br />

<strong>Co</strong>mpatible Head<br />

Holder Fits Chairs Material<br />

6-FHC-S2 Chair Head Positioner 6-FHP-S1 Sm, Med, & Lg Stainless Steel<br />

6-FHC-S6 Chair Head Positioner 6-FHP-S6 Sm, Med, & Lg Stainless Steel<br />

6-FHC-S4 Chair Head Positioner 6-FHP-S4 Sm, Med, & Lg Stainless Steel<br />

6-FHC-S5 Chair Head Positioner 6-FHP-S4/S5 Mini Chair Only Stainless Steel<br />

Three Part Positioner <strong>Co</strong>mponents<br />

<strong>Co</strong>mpatible Head<br />

Product<br />

Part Number<br />

Holder Fits Chairs Material<br />

6-FHC-S2P Head Positioner Top Shaft 6-FHC-S (2,4,6) Sm, Med, Lg Stainless Steel<br />

6-FHC-S2C Head Positioner Sleeve <strong>Co</strong>upler Fits All Models Fits FHC Models Stainless Steel<br />

6-FHC-S2A Head Positioner, Bottom Shaft 6-FHP-S1 Fits FHC Models Stainless Steel<br />

6-FHC-S6A Head Positioner, Bottom Shaft 6-FHP-S6 Fits FHC Models Stainless Steel<br />

6-FHC-S4A Head Positioner, Bottom Shaft 6-FHP-S4 Fits FHC Models Stainless Steel<br />

Two Part Positioner for Head Posts Fits Chairs with Top Bars<br />

Part Number<br />

6-FHB-S2<br />

<strong>Co</strong>mpatible Head<br />

Product<br />

Material<br />

Holder<br />

Universal Head Positioner, complete 6-FHP-S2, B2, X2 Aluminum/ Stainless Steel<br />

Two Part Positioner <strong>Co</strong>mponents<br />

Part Number<br />

Product<br />

<strong>Co</strong>mpatible Head <strong>Co</strong>mpatible<br />

Holder<br />

Chairs<br />

Material<br />

6-FHB-S2A Universal Vertical Bar (top shaft only) Fits All Models Attaches to Chair Aluminum<br />

6-FHB-S2B Adapter Shaft for Head Post on Head 6-FHB-S2A Fits the 3/8” Posts Stainless Steel<br />

6-FHC-S2B-CX Adapter Shaft for Head Cylinder on Head (6-FHP-S1) Sm, Med, & Lg Stainless Steel<br />

6-FHC-S6B-CX Adapter Shaft for Head Cylinder on Head (6-FHP-S6) Sm, Med, & Lg Stainless Steel<br />

6-FHC-S4B-CX Adapter Shaft for Head Cylinder on Head (6-FHP-S4) Sm, Med, & Lg Stainless Steel<br />

6-Adjustable Head Positioner<br />

Part Number<br />

6-FAC-SD<br />

6-FAC-FD-1<br />

6-FAC-SB-R2<br />

6-FAC-SP<br />

6-FAC-SS<br />

6-FAC-S1<br />

6-FAC-S2<br />

Description<br />

Top Shaft for Audio post<br />

Top Shaft for (6-FHB-RA-1)<br />

Top Shaft for the Universal Head Post (6-FHB-S2) Chairs with top bars<br />

Top Shaft for Chairs with Top Plate<br />

<strong>Co</strong>mpass Attachment, Swivels Head Positioner from “0” to 90degrees in two directions<br />

Bottom Shaft only; for head holder on head parts (6-FHP-x1) large Cylinders<br />

Bottom Shaft only; for Head Post on head (6-FHP-x2) Head Posts<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


6-FAC-S4<br />

6-FAC-S6<br />

6-FAC-SB-S1<br />

6-FAC-SB-S2<br />

6-FAC-SB-S4<br />

6-FAC-SB-S6<br />

6-FAC-SD-S1<br />

6-FAC-SD-S2<br />

6-FAC-SD-S4<br />

6-FAC-SD-S6<br />

6-FAC-SP-S1<br />

6-FAC-SP-S2<br />

6-FAC-SP-S4<br />

6-FAC-SP-S6<br />

Bottom Shaft only, for Head Holder Head Parts (6-FHP-S4) small cylinders<br />

Bottom Shaft only, for Head Holder Head Parts (6-FHP-S6) medium cylinders<br />

Adjustable Head Holder Positioner for Universal Head Post and (6-FHP-x1) large cylinders<br />

Adjustable Head Holder Positioner for Universal Head Post and (FHP-x2) head posts<br />

Adjustable Head Holder Positioner for Universal Head Post and (6-FHP-S4) small cylinders<br />

Adjustable Head Holder Positioner for Universal Head Post and (6-FHP-S6) medium cylinders<br />

Adjustable Head Holder Positioner for Audio post and (6-FHP-x1) large cylinders<br />

Adjustable Head Holder Positioner for Audio post and (FHP-x2) head posts<br />

Adjustable Head Holder Positioner for Audio post and (6-FHP-S4) small cylinders<br />

Adjustable Head Holder Positioner for Audio post and (6-FHP-S6) medium cylinders<br />

Adjustable Head Holder Positioner for Top Plate and (6-FHP-x1) large cylinders<br />

Adjustable Head Holder Positioner for Top Plate and (FHP-x2) head posts<br />

Adjustable Head Holder Positioner for Top Plate and (6-FHP-S4) small cylinders<br />

Adjustable Head Holder Positioner for Top Plate and (6-FHP-S6) medium cylinders<br />

Interlocking MRI Style Chair Positioner<br />

Part Number<br />

Product<br />

<strong>Co</strong>mpatible<br />

Head Holder<br />

Material<br />

6-FHD-J9<br />

Two-part Head Holder Position for primate chairs,<br />

designed for conscious/awake MRI use only<br />

6-FHP-J9<br />

CILUX<br />

6-FHD-J9 with 6-FHP-J9<br />

Head Holders on Head (6-FHP)<br />

Head Holders that are positioned on the primate subject’s head are designed for used with the Head<br />

Positioners on the primate chair. The Head Holders are available in two models: Cylinder Style and<br />

Post Style. Head Holders may be ordered in variety of materials and sizes to meet your research<br />

needs.<br />

Cylinder Head Holders<br />

The Cylinder Style Head Holders, cylindrical in shape are designed to securely attach to the skull<br />

with dental acrylic and bone screws. An optional transverse rod is included for particularly active<br />

primate subjects. For added security, this rod fits through two holes at the base of the Head Holder<br />

where it is attached to the acrylic. The upper end of the cylindrical Head Holder attaches to the<br />

Head Holder Positioner on the chair.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Because the Cylinder Style Head Holders has a broader base then the Post Style Head Holders, there<br />

may be better adhesion to the dental acrylic on the skull. This style is also shorter than the post<br />

style, thus less obtrusive.<br />

The Cylinder Style Head Holder is available in the following materials:<br />

· 316 Stainless Steel<br />

· Titanium<br />

· CILUX – recommended for MRI use<br />

· PEEK – recommended for MRI use<br />

(The use of titanium for MRI studies reduces, but does not eliminate the broad shadowing in the MRI field).<br />

The Cylinder Style Head Holder is available in the following sizes:<br />

· Small<br />

· Medium<br />

· Large<br />

We highly recommend the use of our Stereotaxic Alignment Tools to facilitate fixing the Head<br />

Holders in the proper position.<br />

Head Posts<br />

The Head Post provides slightly a different method of positioning the primate subject’s head in the<br />

same orientation each time he/she is placed in the tasking center. One end of the post can be<br />

securely attached to the head with dental acrylic and bone screws, and the other end easily inserts<br />

into the head positioner on the chair. Unlike the cylinder style, the post style does not require the<br />

primate to be crouched into position when connecting the head holder on the head to the head<br />

positioner on the chair. The design of the head post allows the head post to simply be clamped into<br />

the concave cavity on the side of the head positioner.<br />

Post style head holders are is available in 316 stainless steel and titanium.<br />

Note: Using titanium for MRI studies reduces, but does not eliminate the broad shadowing of metals<br />

in the MRI field.<br />

PEEK Head Holders, Cylinder Style<br />

<strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>., Inc. is now offering a new MRI compatible product in addition to our CILUX<br />

made products. We have developed Head Holders made from PEEK. PEEK is a high temperature<br />

resistant engineered thermoplastic with excellent chemical and fatigue resistance and thermal<br />

stability.<br />

Advantages of Peek:<br />

‣ Very high continuous working temperature – mechanical properties are retained even at<br />

temperatures in excess of 250°C (482° F)<br />

‣ Very high heat distortion temperature – HDT is 160° C (320° F)<br />

‣ Exceptional chemical resistance – Peek is insoluble in all common solvents and is extremely<br />

resistant to attack by a very wide range of organic and inorganic chemicals<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


‣ Excellent hydrolysis resistance – Peek has an excellent resistance to hydrolysis in boiling water and<br />

superheated steam at temperatures in excess of 250° C (482° F).<br />

‣ Good radiation resistance – Peek can absorb more than 100 M rads of irradiation with no<br />

significant reduction in mechanical properties and it exhibits exceptional resistance to high doses of<br />

gamma radiation.<br />

‣ Outstanding wear and abrasion resistance – Peek has excellent wear and<br />

abrasion resistance characteristics with low coefficient of friction and high limiting<br />

PV properties<br />

6-HEAD HOLDERS ON HEAD:<br />

Figure 6-15: FHP Head Holders on Head<br />

FHP-S4; FHP-S6; FHP-S1<br />

Cylinder Type Head Holder Sets<br />

Catalog No. Product Size Material<br />

6-FHP-S1 Head Holder on Head (Cylinder Type) 1/2” id (12.7 mm) T316 Stainless Steel<br />

6-FHP-S6 Head Holder on Head (Cylinder Type) 3/8” id (9.5 mm) T316 Stainless Steel<br />

6-FHP-S4 Head Holder on Head (Cylinder Type) 9/32” id (7.1 mm) T316 Stainless Steel<br />

6-FHP-X1 Head Holder on Head (Cylinder Type) 1/2” id (12.7 mm) Titanium<br />

6-FHP-X6 Head Holder on Head (Cylinder Type) 3/8” id (9.5 mm) Titanium<br />

6-FHP-X4 Head Holder on Head (Cylinder Type) 9/32” id (7.1 mm) Titanium<br />

6-FHP-J1 Head Holder on Head (Cylinder Type) 1/2” id (12.7 mm) CILUX<br />

6-FHP-J6 Head Holder on Head (Cylinder Type) 3/8” id (9.5 mm) CILUX<br />

6-FHP-J4 Head Holder on Head (Cylinder Type) 9/32” id (7.1 mm) CILUX<br />

6-FHP-K1 Head Holder on Head (Cylinder Type) 1/2” id (12.7mm) PEEK<br />

6-FHP-K1-A Head Holder on Head (no set, just cylinder) 1/2” id (12.7mm) PEEK<br />

6-FHP-K6 Head Holder on Head (Cylinder Type) 3/8” id (9.5 mm) PEEK<br />

6-FHP-K4 Head Holder on Head (Cylinder Type) 9/32” id (7.1mm) PEEK<br />

Note: cylinder type head holder sets include the following:<br />

· Stainless steel ring<br />

· Screw<br />

· Cylinder (K#-A)<br />

· Stainless steel rod for stainless steel cylinder, nylon rod for all other cylinder materials<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


· Allen wrench for screw<br />

PLUGS (HP-01P, HP-04P and HP06P)<br />

This device is a plastic plug that fits into the Head Holders on the Head to prevent dirt and other debris from<br />

getting inside the cylinder. Plugs are also available to fit the Head Holders used with MRI PRODUCTS. Call<br />

for price quotes.<br />

Catalog No. Product Size Material<br />

6-FHP-01P Plugs for Large Head Holder on Head with Screw 1/2” od (12.7 mm) CILUX<br />

6-FHP-06P Plugs for Medium Head Holder on Head with Screw 3/8” od (9.5 mm) CILUX<br />

6-FHP-04P Plugs for Small Head Holder on Head with Screw 9/32” od (7.1 mm) CILUX<br />

Retaining collars<br />

Catalog No. Product Used with Material<br />

6-FHP-SC1 Stainless Steel Retainer <strong>Co</strong>llar 6-FHP-J1 or 6-FHP-KI Stainless Steel<br />

6-FHP-SC6 Stainless Steel Retainer <strong>Co</strong>llar 6-FHP-J6 or 6-FHP-K6 Stainless Steel<br />

6-FHP-SC4 Stainless Steel Retainer <strong>Co</strong>llar 6-FHP-J4 or 6-FHP-K4 Stainless Steel<br />

6-HEAD POSTS<br />

Figure 6-16: FHP Head Posts FHP-X2; FHP-B2; FHP-S2<br />

Catalog No. Product Size Material<br />

6-FHP-S2 Head Post on Head 3/8” od (9.5 mm) T316 Stainless Steel<br />

6-FHP-B2 Head Post on Head 3/8” od (9.5 mm) Brass<br />

6-FHP-X2 Head Post on Head 3/8” od (9.5 mm) Titanium<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


6-MRI HEAD HOLDER for MRI CHAIRS ONLY<br />

Catalog No. Product Fits Material<br />

6-FHP-J9<br />

Interlocking Head Holder on Head – MRI Use 6-FHD-J9 or 6-FHD-<br />

CILUX<br />

Only<br />

K9<br />

6-FHP-K9<br />

Interlocking Head Holder on Head – MRI Use 6-FHD-J9 or 6-FHD-<br />

PEEK<br />

Only<br />

K9<br />

6-GUIDE TUBES & SPACERS<br />

Guide tubes from <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>mpany may be cut to fit your specified lengths. Our guide tubes are<br />

made from 23TW gauge Stainless Steel or Titanium with flared tops for increased ease when inserting<br />

electrodes. For your convenience, a plug is included.<br />

Price is determined by guide tube size and quantity.<br />

Stainless Steel Guide Tubes<br />

6-YGTS-XX<br />

6-YGTSA-XX<br />

6-YGTSL-XX<br />

Guide Tubes, SS, to 60 mm<br />

Guide Tubes, SS, custom cut to longer length (over 60 mm)<br />

Guide Tubes, SS, with Larger Bore (please specify size)<br />

GUIDE TUBE SPACERS<br />

6-YGSS-23 - Stainless steel spacers come in a standard length of 23 mm. If longer<br />

spacers are required, we can custom cut them for you. Shorter spacers also are available.<br />

(Please Note: For each mm change in size, $0.25 will be added to total price.)<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


GRID ADAPTERS<br />

“Smokestacks”<br />

Grid adapters hold grids rigidly in position. The adapters can be easily removed and replaced in the exact<br />

position in order to allow for cleaning the dura. A pin on the cylinder and slot on the adapter aligns the grid.<br />

Four slots on adapter allow for rotation of grid. A fourfold increase in penetration sites is created with each<br />

style grid.<br />

6-YNS-S1A<br />

Stainless Steel Grid Adapter and Positioner for Stainless<br />

Steel Chambers (<strong>Co</strong>mpatible with Stainless Steel Chambers)<br />

Figure 6-17:<br />

Stainless steel “smoke stacks” grid adapters<br />

6-YNS-J1A<br />

6-YNP-S3<br />

CILUX Grid Adapter & Positioner For Stainless Steel Chambers<br />

(The same as the 6-YNS-S1A except the material is CILUX.)<br />

Stainless Steel Grid Adapter & Positioner, for Pin Style MRI<br />

Chambers or MRI Style Chambers with opposing nylon screws<br />

This Stainless Steel unit provides the interface between the recording cylinder and a Narishige Microdrive<br />

model MO95 without the X-Y Stage Positioner Ring (3-MNJ-S01). This unit fits either the MRI style<br />

chambers, which have opposing nylon screws, or the Pin Style chambers. When the adapter is removed, a<br />

new style cap (6-IP1-J1) should be installed. If, however, you wish to leave the adapter in place, the old style<br />

caps will fit the top of the adapter.<br />

6-YNP-J3<br />

CILUX Grid Adapter & Positioner, for Pin Style MRI Chambers<br />

and the MRI Style Chambers with opposing nylon screws<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


This Grid Adapter Positioner is the same as the 6-YNP-S3 and is used in the same manner. The only<br />

difference is the material. When leaving the adapter in place, use the flat one side CILUX cap.<br />

6-YSS-SU1<br />

Adapter for Cat Chambers, matches with 6-ISC-XX<br />

This unit is Stainless Steel. It also has four (4) slots for rotational fixing and functions much the same as the<br />

6-YNP-S3. When selecting the adapter for cats, the correct chambers, grid, and caps must be selected.<br />

NOTE: The 6-YNP-S3 and the 6-YNP-J3 replaces the 6-YNS-S2. They will fit<br />

on both MRI Chamber Styles.<br />

6-RECORDING CHAMBERS<br />

Figure 6-17: Pictured above, Stainless Steel Angle Recording Chamber, IAC-SA. At<br />

right, the IAM-JA-XX “ CILUX” Angle Chamber, Pin Style.<br />

<strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>mpany's recording chambers are designed to provide vertical penetrations along the<br />

curvature of the skull. As you move outward from the centerline, the recording chamber's degree of angle<br />

should be greater to accommodate. Recording chambers are available with varying degrees of angles, ranging<br />

from 0 to 70 degrees.<br />

Recording chambers angled at "0" degrees are available in stock. Angled recording chambers can be custom<br />

designed to the degree you specify. Please include the angle sizes when ordering. We suggest not ordering in<br />

less than two degree increments.<br />

Our recording chambers are available in a variety of sizes, shapes, and materials:<br />

‣ Stainless Steel chambers are excellent when strength and durability are essential. However,<br />

because Stainless Steel recording chambers are heavier than those made from products like<br />

Titanium and CILUX plastic, you may feel that use with Stainless Steel chambers on small<br />

subjects is limited. Furthermore, Stainless Steel cannot be used for research investigations<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


that include MRI testing. Products that are readily available in Stainless Steel are listed on<br />

the next page.<br />

‣ Titanium Chambers have been found to be very tissue compatible. Titanium is a strong, hard,<br />

and lightweight material. Although, Titanium may be used in the MRI, it does a cast a<br />

shadow, which may reduce the ability to visualize areas located close to the Titanium<br />

Chamber. Titanium Chambers are featured on the following page.<br />

‣ CILUX Chambers, an innovation by <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>mpany, were created in an effort to<br />

find a material that possessed strength, durability, and tissue compatibility that could be used<br />

in MRI testing and could effectively be sterilized. This lightweight plastic suitably meets<br />

these all these requirements. Our CILUX recording chambers work well with animal subjects<br />

of most sizes. CILUX does not absorb water or other fluids readily, and therefore it does not<br />

tend to miss-shape, as many plastics do. Look at the Chambers on the next page for your<br />

choices made from “CILUX”.<br />

MORE ON RECORDING CHAMBERS<br />

“0” DEGREE RECORDING CHAMBER (IAC AND ICO) SERIES:<br />

Designed for use with the Narishige Model MO95B Hydraulic Drive with the “X - Y” Manipulator Base, it<br />

serves as the entry port to the brain. The 6-IAC-S0 does not require the cutting of the skull for screw slots to<br />

facilitate attachment; like the 6-FHP-S1, this device is mounted with a knurl set in the acrylic. This unit<br />

provides a positioning pin for use with the 6-YNS-S2, Chamber to Microdrive Adapter. This pin allows the<br />

removal and replacement (in exactly the same position) of the adapter with the Grid (6-YGD-D1) inside. This<br />

permits cleaning of the dura and flushing of the grid holes.<br />

Furthermore, the 6-YNP-S3 now has four slots allowing a 30 degree angle of rotation, tripling the number of<br />

penetration sites available to you with the standard grid and still allows the use of the Offset Grid (6-YGD-<br />

D2) for four times the penetration sites. Also the use of the Offset Grid will provide “X - Y” aligned<br />

positions. When using the 30/60-degree positions you must consider the angle and the strange pattern<br />

developed.<br />

ANGLE RECORDING CHAMBER (6-IAC-S-XX and 6-ICO-J-XX)<br />

SERIES:<br />

Identical to the IAC and ICO Series “0” Degree, except for its additional length on the long side of the angle.<br />

These chambers are custom cut to various angles to position the chamber on the outer periphery of the skull<br />

and still remain in the vertical axes. We can supply any angle up to 70 degrees per your request. When<br />

ordering this item, the angle you require must be specified in place of the two X’s at the end of the catalog<br />

number. Angle Chambers are available in Stainless Steel and non-magnetic materials.<br />

Pin Style Stainless Steel Chambers<br />

6-IAC-S0 Recording Chamber, “0” degree<br />

6-IAC-SA-xx Recording Chamber, 2 - 45 degree Angle<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


This model, made from Stainless Steel, has a positioning pin that allows exact repositioning of the grid in the<br />

chamber.<br />

6-IAM-J0 Recording Chamber, “0” degree Pin Style for MRI<br />

6-IAM-JA-xx Recording Chamber, 2 - 45-degree Angle Pin Style for MRI<br />

Pin Style Chambers used in the MRI are manufactured from CILUX or PEEK. This model has a positioning<br />

pin that allows exact repositioning of the grid in the chamber. If the adapter is left on for any length of time,<br />

your old standard cap can be used. Use the new matching cap with this product when the adapter is removed.<br />

This adapter can be removed with the manipulator still mounted.<br />

The advantage of the CILUX and PEEK Chambers is that they can be sterilized without absorbing water and<br />

misshaping, unlike many other plastics. CILUX and PEEK materials are also harder and threads are more<br />

slip resistant than many other plastics.<br />

This product can be purchased in its separate components or it can be purchased as a set. Sets include either a<br />

“0” Degree Chamber (6-IAM-J0) or an “Angle” Chamber (6-IAM-J2A-xx) with one matching cap 6-(IP1-<br />

J1) and a matching Adapter/Positioner (6-YNP-S3).<br />

6-MRI Style with Opposing Nylon Screws<br />

6-ICO-J0<br />

6-ICO-J2A-xx<br />

Recording Chamber,“0” degree<br />

Recording Chamber, 2 - 45 degree Angle<br />

NEW MRI Style w/opposing nylon screws 6-ICO-J2A-zz. Recording Chamber, 46 - 65 degree Angle NEW<br />

MRI Style w/opposing nylon screws. The CILUX chambers have an overall outside diameter of 1” (25.3<br />

mm). The inside diameter of the CILUX chambers is 3/4” (19 mm).<br />

The MRI Style chambers provide a lower profile and stronger construction. The Chambers are made from<br />

our new stronger CILUX. The advantage of the CILUX Chambers is that they can be sterilized without<br />

absorbing water and misshaping as many other plastics. It is also harder than many other plastics and threads<br />

do not strip as readily as in other plastic materials. If the Adapter is left on for any length of time, your old<br />

Standard Cap can be used. Use the new matching cap with this product when the Adapter is removed. This<br />

Adapter can be removed with the manipulator still mounted. This product can be purchased in its separate<br />

components or it can be purchased as a set. Sets include either a “0” Chamber (6-ICO-J0) or an “Angle”<br />

Chamber (6-ICO-J2A-xx) with one matching cap 6-(IP1-J1) and a matching Adapter/Positioner (6-YNP-<br />

S3).<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Figure 6-19: 6-ICO-J2A Recording Chamber and old style 6-YNS-J1A Grid Adapter.<br />

Note: the New Grid Adapters have slots as well as the cut away for the screws.<br />

Recording Chambers for Other Animals<br />

6-ISM-J-00<br />

Recording Chamber for Squirrel Monkeys<br />

6mm o.d. Specify 0 to 60 Degree angle, CILUX<br />

6-ISC-xx<br />

Recording Chamber for Felines<br />

Chamber is curved (form fitted), Stainless Steel. The o.d. on this chamber is approximately<br />

.750” and the i.d. is .630”.<br />

NOTE: Please remember that the “-S” and “-J” in the Chamber part number denotes the<br />

product material Stainless Steel and CILUX respectively.<br />

6-Recording Chamber Sets<br />

For your convenience, sets are available as defined below. They include the chamber<br />

with the angle you specify a matching cap and an adapter (“smokestack”)<br />

Catalog No. Product Material<br />

6-IAM-J2AS-0 Recording Chamber, SET, MRI Pin Style “0” deg Cilux<br />

6-IAM-JAS-xx Recording Chamber, SET, MRI Pin Style Angle deg Cilux<br />

6-ICO-J2AS-00 Recording Chamber SET, MRI “0” deg, w/ opposing nylon screws Cilux<br />

6-ICO-J2AS-xx Recording Chamber SET, MRI 2 - 45 deg. Angle with opposing nylon screws Cilux<br />

6-ICO-J2AS-zz Recording Chamber, SET, MRI 46 - 65 deg. Angle with opposing nylon screws Cilux<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


PEEK RECORDING CHAMBERS: BLANK AND ANGLE<br />

Catalog No. Product Material<br />

6-IAM-K2A-0 Recording Chamber, MRI Pin Style “0” deg PEEK<br />

6-IAM-KA-xx Recording Chamber , MRI Pin Style Angle deg PEEK<br />

6-YGD – GRIDS<br />

The Grid is used to align Guide Tubes for a straight and accurate penetration. Holes are 1 mm apart in a<br />

rectangular array within a 19 mm diameter. Accurate alignment is accomplished by 1 cm long guide holes. A<br />

Spacer is recommended to bring the Guide Tube Top (flared end) near the top of the Grid Cup. The Offset<br />

Grid is identical except the holes are offset .5 mm in one direction in the array. The direction of the offset is<br />

indicated by a missing hole near the perimeter of the grid. When used in conjunction with the Standard Grid<br />

(6-YGD-D1) it provides three times as many penetration points when the offset is rotated 90 degrees.<br />

Catalog No. Product Size Material<br />

6-YGD-D1 Grid, Standard w/ Pattern 1 mm o.c. 19 mm diameter x 40 mm tall Delrin<br />

6-YGD-D2 Grid, Offset, w/ Pattern 1 mm o.c. offset .5 mm 19 mm x 40 mm tall Delrin<br />

6-YGD-D1A Grid, Short Version w/ Standard Pattern 19 mm Dia x 19.5 mm tall Delrin<br />

6-YGD-D2A Grid, Short Version w/ Offset Pattern 19 mm Dia x 19.5 mm tall Delrin<br />

6-YGD-D1-DM Grid, w/ dye Markers, 4 markers at 90 degree intervals Delrin<br />

6-YGD-J1 Grid, Standard w/ Pattern 1 mm o.c. 19 mm x 40 mm tall CILUX<br />

6-YGD-J2 Grid, Standard w/ Pattern 1mm o.c. offset .5mm 19 mm x 40 mm tall CILUX<br />

6-YGD-J1A Grid, Short Version w/ Standard Pattern 19 mm Dia x 19.5 mm tall CILUX<br />

6-YGD-J2A Grid, Short Version w/ Offset Pattern 19 mm Dia x 19.5 mm tall CILUX<br />

6-YGD-BP Grid Base Plate Stainless Steel<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Plate provides an attachment point for guide tubes and electrodes that are to be implanted for long term<br />

chronic studies of a single site. (Cannot be used with Biela Microdrive System.)<br />

Catalog No. Product Material<br />

6-YGD-D1-XX<br />

Custom Angle Grids, up to 10 degrees, the same size and hole pattern as the<br />

standard grid<br />

Delrin<br />

6-YGD-J1-XX<br />

Custom Angle Grids, up to 10 degrees, the same size and hole pattern as the<br />

standard grid<br />

Cilux<br />

6-YGD-D3<br />

6-YGDIPI-J1<br />

6-YGDIPI-J2<br />

6-YGDIPO-J1<br />

6-YGDIPO-J2<br />

Flat Grid<br />

Grid Cap a unique combination of the standard grid pattern made directly in the<br />

cap, F Round<br />

Grid Cap a unique combination of the offset grid pattern made directly in the cap,<br />

F Round<br />

Grid Cap a unique combination of the standard grid pattern made directly in the<br />

cap, Flat Side<br />

Grid Cap a unique combination of the offset grid pattern made directly in the cap,<br />

Flat Side<br />

Cilux<br />

Cilux<br />

Cilux<br />

Cilux<br />

MINIATURE GRIDS<br />

Catalog No. Product Material<br />

6-RGDIPI-J1 Grid Cap for rat chambers or other small animals CILUX<br />

6-RGP-J1 Grid Plug fits into small chambers for rats or other small animals CILUX<br />

6-IPO & IPI CAPS<br />

Caps are made in two styles. IP0 works with the Stainless Steel Chambers, the 6-YNS-S1A Adapter and the<br />

“Old Style” GF Delrin Chamber styled like the Stainless Steel Chambers. The IPI fits the New MRI Style<br />

Recording Chambers. Caps made from Delrin, Polypropylene CILUX and Stainless Steel. The Delrin and<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Polypropylene are water sensitive and may distort if submerged for any length of time in liquid. We<br />

recommend you use only short-term liquid or gas sterilization for these materials. The CILUX material is<br />

substantially more resistant to water absorption. Stainless Steel Caps are significantly more durable;<br />

however, they are also much heavier. For smaller animals, the lighter weight materials are recommended.<br />

Caps are available in CILUX and Stainless Steel. They are designed to protect openings in the Recording<br />

Cylinders. They fit all cylinders; and also the 6-YNS-S1A when left in place with the Grid and Guide Tube<br />

(YGTS-SS and YGTSA-XX) for chronic studies. In addition, special caps are available for use with the Beila<br />

Microdrives that have been specially modified to fit inside the Grid cup for long-term chronic studies.<br />

Catalog No. Product Material<br />

6-IP0-J1 Caps, Flat one side Cilux<br />

6-IP0-S1 Caps, Flat one side Stainless Steel<br />

6-IPI-J1 Caps, Full Round Style for NEW MRI Cilux<br />

6-IPI-S1 Caps, Full Round Style for Stainless Steel Stainless Steel<br />

6-IRO-J3 Cap, fits Cat Chamber & Adapter Cilux<br />

CRANIAL IMPLANT FASTENERS & SELF TAPPING SCREWS<br />

We manufacture 2 styles of Cranial Screws. Cranial Implant Head Bolts are available in 3 types of materials<br />

and several different sizes to meet your exacting needs. Our Cranial Fasteners slip securely under the skull<br />

and are held in place with a double nut imbedded in dental acrylic. They are available in Stainless Steel,<br />

Titanium and “CILUX”. The titanium self-tapping screws thread into the skull and are available in two sizes.<br />

6-CRANIAL FASTENERS (HEAD BOLTS) - STAINLESS STEEL packaged in sets of 5<br />

6-YCI-06 Cranial Fasteners, w/nuts & washer,<br />

(Formerly YCX-01)<br />

6-32 x 1/2” (12.7mm long)<br />

6-YCI-06L Cranial Fasteners, w/nuts & washer, 6-32 x 5/8” (15.87mm long)<br />

6-YCI-06S Cranial Fasteners, w/nuts & washer, 6-32 x 7/16” (11.1mm long)<br />

6-YCI-08 Cranial Fasteners, w/nuts & washer, 8-32 x 5/8” (15.98mm long)<br />

6-CRANIAL FASTENERS (HEAD BOLTS) - TITANIUM packaged in sets of 3 or 5 (for sets<br />

of 3 add a -3 to your choice below; for sets of 5 add a -5 to your choice below.<br />

6-YCX-06 Cranial Fasteners, w/nuts & washer,<br />

(Formerly YCX-01)<br />

6-32 x 1/2” (12.7mm)<br />

6-YCX-06L Cranial Fasteners, w/nuts & washer<br />

6-32 x 5/8” (15.87mm)<br />

6-YCX-06S Cranial Fasteners, w/nuts & washer 6-32 x 7/16” (11.1mm)<br />

6-YCX-08<br />

Cranial Fasteners, w/nuts & washer, (Formerly YCX-02)<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


6-CRANIAL FASTENERS (HEAD BOLDS) - “CILUX” (packaged in sets of 5)<br />

6-YCJ-08 Cranial Fasteners, w/nuts & washer 8-32 x 9/16”<br />

6-YCJ-10 Cranial Fasteners, w/nuts & washer 10-32 x 5/8”<br />

6-YCJ-10L Cranial Fasteners, w/nuts & washer 10-32 x 3/4”<br />

6-YCJ-10S Cranial Fasteners, w/nuts & washer 10-32 x 9/16”<br />

6-YCJ-10P Cranial Fasteners, w/nuts & washer with reinforced head 10-32 x .800”<br />

6-YCJ-14 Cranial Fasteners, w/nuts & washer 1/4-20 x 5/8”<br />

6-SELF-TAPPING BONE SCREWS -<br />

TITANIUM packaged in sets of 3 or 5<br />

These screws have a Taper Thread and require a<br />

small wrench to tighten.<br />

Screws have a .104” thread<br />

diameter (2.6 mm) x .217”<br />

(5.5mm long) thread length<br />

and an overall length of<br />

.315” (8mm). For sets of 3<br />

add a-3 to your order<br />

selection as shown below or<br />

for sets of 5 add a -5 as shown.<br />

6-YCX-03-5 Bone Screws, Allen Head<br />

6-SPAW-3/32 Allen Wrench 3/32<br />

6-YCX-03-3 Bone Screws, Allen<br />

Head<br />

NOTE: To avoid drilling too deep, remember to always use a 6-T50 depth gauge with your selftapping<br />

bone screws<br />

6-SURGICAL AIDS<br />

6-20: 6-YWP-D01 Wurtz Pusher (Pictured<br />

at Left)<br />

Use to push wire from eye to top of skull. Low<br />

trauma instrument.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Figure 6-21: Surgery Ring (Pictured to the Right)<br />

This device holds the skin flap(s) away from the skull during<br />

surgery. Made of Stainless Steel, it<br />

provides clear open area to work without a clutter<br />

of hemostats around the work area.<br />

Figure 6-22: 6-YET-H2 Eye <strong>Co</strong>il Template (Pictured at Left) Provides a variety of diameters to size<br />

your Eye <strong>Co</strong>ils for implant. The diameters range in size from 8 mm. to 17 mm in 1/2 mm<br />

increments.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


6-HCD-30-25 Tantalum Matrix Disk<br />

This is a unique, highly porous and highly biocompatible device that allows cells to grow in three dimensions<br />

the way they do normally in the body. Made from inert materials through a sophisticated manufacturing process.<br />

This breakthrough biomaterial takes cell culture to a new dimension. This line of 3-Dimensional Cytomatrix culture<br />

devices can be used:<br />

· To grow primary cells and established lines<br />

· To grow tumor cells isolites and lines<br />

· To grow high density attachment dependent cell cultures<br />

· To close and repair holes in bone left from the removal of recording chambers and the like.<br />

Matrix<br />

Features<br />

· 3-Dimensional Structure<br />

o biomimetic architecture<br />

· High Porosity<br />

o >90% open space<br />

· High surface area to volume<br />

rationo<br />

available growth area<br />

60-70 cm 2 /ml<br />

· Excellent biocompatibility<br />

o inert metal composite<br />

o clinical product is FDA<br />

compliant*<br />

· Fully interconnected geometry<br />

o uniform mass transfer<br />

· Surface coatable<br />

o<br />

antibodies, adhesion<br />

molecules etc.<br />

· Multiple configurations<br />

o<br />

6, 12, 24, 48, 96 well<br />

units and 30 x 60mm<br />

format<br />

· Scalable Technology<br />

Features<br />

· High Density growth<br />

o 2 x 10 7 to 8 x 10 7 cells/ml attainable<br />

o tissue-like density<br />

· Variety of applications and configurations<br />

o basic research<br />

o bioproduction<br />

o protein/expressed product<br />

o cell mass<br />

o drug candidate screening<br />

o Theranostics/Diapeutics<br />

o co-culture systems<br />

· Pilot scale, custom assemblies<br />

· Successful culture of:<br />

o primary cells; hepatocytes,<br />

fibroblasts, mesenchymal, islet and<br />

neuronal cells<br />

o transformed cells: cancer cells and<br />

lines<br />

o production cells: CHO, 3T3, and<br />

HEK 293 cells<br />

· No dead space in growth area<br />

*Clinical product is not for commercial<br />

sale<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Scanning electron micrographs of Cytomatrix<br />

Advantages<br />

· Uniform 3-Dimensional Structure<br />

o The 3-Dimensional structure and porosity of the Cytomatrix bears a remarkable resemblance of that<br />

of human bone marrow trebeculae. This provides cells with an in vivo, tissue-like cellular growth<br />

scaffold for a variety of cell culture applications.<br />

· Unique Textured Surface<br />

o The Cyotmatrix inert metallic coating provides the cells with a novel, highly textured surface to<br />

which attachment-dependent cells have a remarkable affinity for attachment and growth. This provides<br />

the cells with a desirable substrate on which to adhere and thrive.<br />

· Biomimetic Microenvironment<br />

o The unique 3-Dimensional architecture of the Cytomatrix is a highly desirable structure with in situlike<br />

properties. This provides attachment-dependent cells with a biomimetic microenvironment, which<br />

fosters natural inter-cellular signaling and simulates growth in an in vivo, tissue-like setting.<br />

· Versatile<br />

o The reliability of the highly consistent architecture of the Cytomatrix allows for a wide variety of<br />

product formats and presentations. This provides the end-user with a highly versatile research tool to<br />

investigate a wide variety of cell culture applications.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


6-Spare Parts<br />

6-HPS-<br />

01A<br />

6-HPP-<br />

01A<br />

6-ST-<br />

02J<br />

6-ST-<br />

01S<br />

Head Holder on<br />

Head, SS, Screw<br />

Set<br />

Head Holder on<br />

Head, CILUX,<br />

Screw Set<br />

Stereotaxic<br />

Alignment Tool<br />

Parts Set, MRI<br />

Type set Parts<br />

for: Alignment<br />

Tool for Head<br />

Holder on Head,<br />

Alignment Tool<br />

for Cylinders<br />

Alignment Tool<br />

for Grids and<br />

Support Ring<br />

Screws for Head<br />

Holder on Head<br />

Stereotaxic<br />

Alignment Tool<br />

Parts Set, SS set<br />

1<br />

Parts for:<br />

Alignment Tools<br />

for Head Holders<br />

on Head,<br />

Alignment Tools<br />

for Cylinders<br />

and Grid<br />

Section 6 Implant & Alignment Parts<br />

8-32 x 3/4” Flat<br />

Head Allen Cap<br />

1<br />

1/8” x 1-1/2” Rod 1<br />

9/64 Allen Wrench 1<br />

Same as above<br />

w/CILUX Rod<br />

8-32 x 1” Flat Head<br />

Allen Cap Screws<br />

8-32 x 7/8” Flat<br />

Head Allen Cap<br />

Screws<br />

6-32 x 5/8” Flat<br />

Head Allen Cap<br />

Screws<br />

6-32 x 1/2” Flat<br />

Head Allen Cap<br />

Screws<br />

2-56 x 1/8” <strong>Co</strong>ne<br />

Point Set Screws<br />

4-40 x 1/8” <strong>Co</strong>ne<br />

Point Set Screws<br />

3/32, 5/64, 7/64, .035<br />

and .050 Allen<br />

Wrenches<br />

8-32x 7/8” Flat Head<br />

Allen Cap Screws<br />

8-32x 3/4” Flat Head<br />

Allen Cap Screws<br />

6-32x 3/8” Flat Head<br />

Allen Cap Screws<br />

6-32x 1/2” Flat Head<br />

Allen Cap Screws<br />

4-40x 1/8” Flat<br />

Head Allen Cap<br />

Screws<br />

1<br />

1<br />

2<br />

1<br />

1<br />

6<br />

3<br />

1 Each<br />

2<br />

1<br />

1<br />

1 each<br />

3<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Alignment Tools:<br />

3/32, 5/64, 7/64 and<br />

.050 Allen<br />

Wrenches<br />

1<br />

Part No.<br />

6-NCO-J1A<br />

6-NCS-01A<br />

6-NCS-02C<br />

6-NSS-01AA<br />

<strong>Co</strong>mponent Name &<br />

Parts<br />

<strong>Co</strong>ne Pt. Set Screw for Caps<br />

(IPO, IPI)<br />

<strong>Co</strong>ne Pt. Set Screw for two<br />

Caps (IPO, IPI)<br />

Screws, for New MRI<br />

Chambers<br />

Chamber Adapter (Smoke<br />

Stack) Screws set<br />

Parts<br />

Total per set<br />

Eye Bar Plate Thumb Screw Q20 1<br />

4-40 x 1/8” <strong>Co</strong>ne Pt. Set Screw 3<br />

.050 Allen Wrench 1<br />

4-40 x 1/8” <strong>Co</strong>ne Pt. Set Screw 6<br />

.050 Allen Wrench 2<br />

4-40 x 1/4” Nylon Pan Head Screws 10<br />

2-56 x 1/8” <strong>Co</strong>ne Point Set Screws 6<br />

.035 Allen Wrench 2<br />

6-SB-000 Base Plate Screws 4<br />

6-SPAW035 Small Allen Wrenches, .035<br />

2<br />

6-SPAW050 Small Allen Wrenches, .050<br />

2<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


New Products Available 1 ST Quarter ‘08<br />

7-MTS-4xxx Eye Tracker 4000<br />

Front View of the Magnetrack<br />

.<br />

<strong>Co</strong>mplete set-up of Magnetrack with the coil-frame (Oscilloscope not included)<br />

Our new Digital Eye Tracking system is based on our proven Magnetrack 3000 Analog system with<br />

the addition of easier to use Operator controls, <strong>Co</strong>nfiguration Selection, Subject parameter memory<br />

and PC configuration ability.<br />

This is the First in our new line of MultiRack Family of systems. MultiRack systems will utilize a<br />

one, two or eight slot enclosure to house various configurations of standard function modules.<br />

SPECIAL FEATURES<br />

· All configuration parameters are digitally controlled to allow saving / recalling of calibration<br />

data.<br />

· All configuration and calibration is done from a master control unit.<br />

o 2D / 3D and number of sensor (eye) coils<br />

o Driver <strong>Co</strong>il size.<br />

o Subject selection.<br />

o Frequency selection.<br />

o <strong>Co</strong>il drive level and phase<br />

o Receiver Gain, Offset and phase<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


· <strong>Co</strong>il Drive Frequency is digitally generated to provide high stability. This also allows only<br />

one version driver module to be needed instead of the previous two.<br />

· Sensor coil receivers are designed to provide all three axis outputs from one module. Unlike<br />

the previous system, no sharing of receivers or complicated cross configuration of modules is<br />

required.<br />

· <strong>Co</strong>il tuning is now done with a capacitor array, based on supplied inductance of coil.<br />

Removable / replaceable capacitor boards are no longer required.<br />

· Tuning data for the system is provided by the PC <strong>Co</strong>nfiguration software using supplied<br />

frequency and coil inductance.<br />

· Up to eight sets of calibration data can be stored to allow multiple subject selection.<br />

· Calibration data may also be read by the PC <strong>Co</strong>nfiguration software and stored in text files.<br />

This provides for an unlimited number of subjects.<br />

· PC <strong>Co</strong>ntrol is via standard RS-232 serial port. All message protocol is published to allow<br />

control from any software system that has access to the serial ports. (A USB to Serial<br />

converter can also be used)<br />

· The system may be operated totally without a PC connection if desired.<br />

· A Digital Reward module is available for use with the eye tracking system. This module is<br />

also a member of our MultiRack Family of systems and has all the same great features of our<br />

5-RLD-D1-B: PC control / data collection, Wireless remote, and an expanded line of Sensors<br />

and Dispensers.<br />

Available system configurations:<br />

Catalog #<br />

7-MTS-4210<br />

7-MTS-4211<br />

7-MTS-4220<br />

7-MTS-4221<br />

7-MTS-4230<br />

7-MTS-4231<br />

7-MTS-4310<br />

7-MTS-4311<br />

7-MTS-4320<br />

7-MTS-4321<br />

7-MTS-4330<br />

7-MTS-4331<br />

7-MTS-4000<br />

<strong>Co</strong>nfiguration<br />

2D / 1 sense coil<br />

2D / 1 sense coil / Reward<br />

2D / 2 sense coil<br />

2D / 2 sense coil / Reward<br />

2D / 3 sense coil<br />

2D / 3 sense coil / Reward<br />

3D / 1 sense coil<br />

3D / 1 sense coil / Reward<br />

3D / 2 sense coil<br />

3D / 2 sense coil / Reward<br />

3D / 3 sense coil<br />

3D / 3 sense coil / Reward<br />

MultiRack Rack Only<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


<strong>Co</strong>ntroller Driver Receiver Reward<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


MAGNETIC FIELD COILS (SEARCH COILS)<br />

The Magnetic Field <strong>Co</strong>il has a non-conductive frame that supports the coil windings to produce a linear<br />

magnetic field at the center of a cube. It is driven by an electronic driver system, which when operating<br />

creates the linear magnetic field. Our field coils work best with the Magnetrack 3000; but, can be configured<br />

to work with other manufacturers control units. These coils come in a variety of frequencies and power levels.<br />

<strong>Crist</strong> <strong>Instrument</strong> coil frames are available in a variety of sizes to fit various eye detector systems. The coils are<br />

available in 15-inch, 18-inch, 22-inch and 36-inch. <strong>Co</strong>ils of other sizes can be produced upon request. If your<br />

organization owns a coil driver system produced by another manufacturer that does not provide the coil<br />

frame, we would be glad to produce it to their specifications in any size.<br />

7-SSCP-15<br />

Search <strong>Co</strong>il, 15-inch (38.10cm)<br />

Designed to fit over most Standard size Chairs and to rest on side supports (wings). The inside opening<br />

diameter is 13 inches (33.02cm). The <strong>Co</strong>il diameter at the winding is 15 inches (38.1cm) and the outside<br />

diameter is 18 inches (45.72cm) on each side.<br />

7-SSCP-18<br />

Search <strong>Co</strong>il, 18-inch (45.72cm)<br />

Designed to fit over a Large Chair or when your Standard Chair has options which would interfere with the<br />

15 inch fitting over those options. As with the 15 inch, it rests on side supports (wings). The inside opening<br />

diameter is 17 inches (43.18cm). The <strong>Co</strong>il diameter at the winding is 18 inches (45.72cm) and the outside<br />

diameter is 22 ½ inches (57.15cm) on each side.<br />

7-SSCP-22<br />

Search <strong>Co</strong>il, 22-inch (55.88cm)<br />

Special order. The inside opening diameter is 20.125 inches (51.12cm). The <strong>Co</strong>il diameter at the winding is<br />

22 inches (55.88cm) and the outside diameter is 26.375 inches (66.99cm) on each side.<br />

7-SSCW-36<br />

Search <strong>Co</strong>il, 36-inch (91.44cm)<br />

Special order. This is one of our full sized coils. To make it easier to center the chair within the coil a lifting<br />

device is recommended. See Section 8, Laboratory Structures. The inside opening diameter is 34.5 inches<br />

(87.63cm). The <strong>Co</strong>il diameter at the winding is 36 inches (91.44cm) and the outside diameter is 41.5 inches<br />

(105.41cm) on each side.<br />

Figure7.1<br />

<strong>Co</strong>il Frame<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


OPTICAL SECTION<br />

7-OIM-AF (0)<br />

Eye Mask<br />

The Eye Mask is designed to hold different color filters and occluders. This mask fits over the eyes similar<br />

to a pair of glasses and can be mounted on the three-part head holder (6-FHC-S2) on the primate chair. It can<br />

also be adapted to mount on a variety of other fixtures.<br />

TANGENT SCREENS<br />

Tangent Screens are one of the components used in studying the central visual system and visual behavior<br />

modes. Our Tangent Screens create a minimal image distortion and provide remarkably good light<br />

transmission. This screen works well for both front and rear projection. It is the result of over two years of<br />

developmental work and has been used since before 1989.<br />

The screen material used is Lumiplex, providing a smooth texture with minimal pattern. As tested with a light<br />

source of 32.4 cd/m2, it has been attenuated to 15.8 cd/m2 when measured by a Tektronics Luminance Probe.<br />

Image intensity, under those conditions, for rear projections is reduced no more than 51%. It has been<br />

reported to us by some investigators to be reduced by no more than 15%. When establishing and repetitively<br />

recording visual receptive fields, the screen can be written on with a wax crayon or a felt-tip pen.<br />

7-QTS-L1<br />

Moveable Tangent Screen<br />

This Tangent Screen is mounted on a frame that hangs from the ceiling. It can be moved in a straight line for<br />

a selected distance from the subject in order to aid in radian calculation. If it is preferred, it can be swung<br />

upward and latched in place near the ceiling. This will allow for a Touch Screen Monitor or some other<br />

device to be positioned in its place without interference. This is also a good storage position in that it is less<br />

likely to be damaged when not in use. The top of the screen has a hinge mechanism and linear bearings that<br />

allow it to travel easily along the visual center line, while the hinge allows for the storage position.<br />

We recommend that installation of this type of screen be executed by <strong>Crist</strong> <strong>Instrument</strong> Technical Staff or at<br />

the very least by highly skilled craftsmen. Detailed instructions can be provided as needed. Help is only a<br />

phone call away. Installation is not included in the price of the screen.<br />

7-QTS-L2<br />

Stationary Tangent Screen<br />

This model is fixed in place from the floor to ceiling with a preset distance from the center.<br />

7-QTS-L3<br />

Tangent Screen on Platform<br />

This model is mounted on a rolling platform for use in multiple laboratory locations.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Section 9 – Stereotaxic Devices<br />

Figure 9-1: Stereotaxic Apparatus for MRI Work (9-YST1-30)<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Stereotaxic Apparatus<br />

<strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>., Inc. now provides a variety of different sizes and models of Stereotaxic<br />

Frames. Because we are expanding this product, we are changing the part numbers and moving these<br />

products from Section 6 to Section 9 in our catalog. This should aid you in locating these products<br />

and their optional parts.<br />

The Primate Stereotaxic Models are listed in the table below. In addition, there is a model that is<br />

especially useful when working with cats (9-YSTC-1). We will also be adding a model for rats,<br />

mice, and other small animals in the near future.<br />

Our Primate Stereotaxic Frames are suitable for use in the MRI and for light surgery. The device is<br />

compatible with a variety of Kopf Manipulators and Positioners. It is designed principally for<br />

holding the animal's head in the MRI. When it is used in surgery, there will be no discrepancies in<br />

the positioning. All models of Stereotaxic Frames are determined by the bore size of your MRI. Each<br />

model is available in two material types; aluminum/plastic and all plastic. The magnetic power of<br />

your MRI will determine which material you will require in your frame. The Metal and Plastic frame<br />

is usable in surgery with care and delicacy.<br />

A number of options are available with each model. These include Offset and Straight Ear and Eye<br />

Bars, a variety of Ear Tips, different Eye Bar Position Plates and an Anterior Dye Marker There are<br />

two sizes of anterior/posterior sidebars for these models. When ordering, please specify which size<br />

you require 19 cm. and 22 cm. Note that the A/P Bars for Baboons are available in only one size 22<br />

cm. The Ear Bar Tips are available in the sizes and shapes listed as A through M (See Drawing).<br />

Please specify which tip you need for your project. All Tips have dye markers in the center. The<br />

smaller model Stereotaxic Frames (e.g. 9-YSTI-22 and 9-YST-18) are especially recommended for<br />

new world monkeys and infant macaques.<br />

Part No. Model Name Material Type Included Options Old Part #<br />

9-YSTI-35-A-O<br />

9-YSTI-35-P-O<br />

9-YSTI-30-A-O<br />

9-YSTI-30-P-O<br />

Stereotaxic Frame<br />

for 35 cm. Bore<br />

MRI<br />

Stereotaxic Frame<br />

for 35 cm. Bore<br />

MRI<br />

Stereotaxic Frame<br />

for 30 cm. Bore<br />

MRI<br />

Stereotaxic Frame<br />

for 30 cm. Bore<br />

MRI<br />

Aluminum and<br />

Acrylic<br />

All Plastic<br />

Materials<br />

Aluminun and<br />

Acrylic<br />

All Plastic<br />

Materials<br />

Offset ear and Eye<br />

Bars<br />

Offset Ear and Eye<br />

Bars<br />

Offset Ear and Eye<br />

Bars<br />

Offset Ear and Eye<br />

Bars<br />

6-YSMRI-10<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Part No.<br />

9-YSTI-24-A-O<br />

9-YSTI-24-P-O<br />

9-YSTI-22-A-O<br />

9-YSTI-22-P-O<br />

9-YSTI-18-A-O<br />

9-YSTI-18-P-O<br />

9-YSTI-38-A-O<br />

9-YSTI-38-P-O<br />

9-YSTI-35-A-S<br />

9-YSTI-35-P-S<br />

9-YSTI-30-A-S<br />

9-YSTI-30-P-S<br />

9-YSTI-24-A-S<br />

9-YSTI-24-P-S<br />

9-YSTI-22-A-S<br />

Model Name Material Type Included<br />

Options<br />

Stereotaxic Aluminum and<br />

Frame for 24 Acrylic<br />

cm. Bore MRI<br />

Stereotaxic<br />

Frame for 24<br />

cm.<br />

Stereotaxic<br />

Frame for 22<br />

cm. Bore MRI<br />

Stereotaxic<br />

Frame for 22<br />

cm. Bore MRI<br />

Stereotaxic<br />

Frame for 18<br />

cm. Bore MRI<br />

Stereotaxic<br />

Frame for 18<br />

cm. Bore MRI<br />

Stereotaxic<br />

Frame for 38<br />

cm. Bore MRI<br />

Stereotaxic<br />

Frame for 38<br />

cm. Bore MRI<br />

Stereotaxic<br />

Frame for 35<br />

cm. Bore MRI<br />

Stereotaxic<br />

Frame for 35<br />

cm. Bore MRI<br />

Stereotaxic<br />

Frame for 30<br />

cm. Bore MRI<br />

Stereotaxic<br />

Frame for 30<br />

cm. Bore MRI<br />

Stereotaxic<br />

Frame for 24<br />

cm. Bore MRI<br />

Stereotaxic<br />

Frame for 24cm.<br />

Bore MRI<br />

Stereotaxic<br />

Frame for 22<br />

cm. Bore MRI<br />

All Plastic<br />

Aluminum and<br />

Acrylic<br />

All Plastic Materials<br />

Aluminum and<br />

Acrylic<br />

All Plastic Materials<br />

Aluminum and<br />

Acrylic<br />

All Plastic Materials<br />

Aluminum and<br />

Acrylic<br />

All Plastic Materials<br />

Aluminum and<br />

Acrylic<br />

All Plastic Materials<br />

Aluminum and<br />

Acrylic<br />

All Plastic Materials<br />

Aluminum and<br />

Acrylic<br />

Offset Ear and<br />

Eye Bars<br />

Offset Ear and<br />

Eye Bars<br />

Offset Ear and<br />

Eye Bars<br />

Offset Ear and<br />

Eye Bars<br />

Offset Ear and<br />

Eye Bars<br />

Offset Ear and<br />

Eye Bars<br />

Offset Ear and<br />

Eye Bars<br />

Offset Ear and<br />

Eye Bars<br />

Straight Ear<br />

and Eye Bars<br />

Straight Ear<br />

and Eye Bars<br />

Straight Ear<br />

and Eye Bars<br />

Straight Ear<br />

and Eye Bars<br />

Straight Ear<br />

and Eye Bars<br />

Straight Ear<br />

and Eye Bars<br />

Straight Ear<br />

and Eye Bars<br />

Old Part #<br />

6-YSTMRI-22<br />

6-YSTMRI-<br />

22S<br />

6-YSTMRI-<br />

10S<br />

6-YSTMRI-<br />

Bab<br />

6-YSTMRI-10<br />

6-YSTMRI-22<br />

6-YSTMRI-<br />

22S<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Part No. Model Name Material Type Included<br />

Options<br />

9-YSTI-22-P-S Stereotaxic All Plastic Materials<br />

Frame for 22<br />

cm. Bore MRI<br />

9-YSTI-18-A-S<br />

9-YSTI-18-P-S<br />

Stereotaxic<br />

Frame for 35<br />

cm. Bore MRI<br />

Stereotaxic<br />

Frame for 35<br />

cm. Bore MRI<br />

Aluminum and<br />

Acrylic<br />

All Plastic Materials<br />

Straight Ear<br />

and Eye Bars<br />

Straight Ear<br />

and Eye Bars<br />

Straight Ear<br />

and Eye Bars<br />

Old Part #<br />

6-YSTMRI-<br />

10S<br />

9-YSTMRI-30-P-S<br />

Standard 30 cm MRI Stereotax<br />

Front View<br />

Rear View<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


9-YSTMRI-22-A-O<br />

22 cm Stereotaxic System<br />

Lower right oblique view:<br />

View from Posterior:<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


9-CSTI-16/12<br />

Bird Cage RF Stereotaxic System<br />

Side View<br />

Front View<br />

Eyebar System showing eyebars<br />

with dye markers, and Pallet bar<br />

Eyebar showing dye marker &<br />

bone-hook<br />

Bone Hook<br />

Dye Marker<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


9-RMS1<br />

Rat Stereotaxic System<br />

Front View<br />

Top View<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Figure 6-2: Available Ear Bar Tips<br />

Figure 6-2: NOTE: Different Ear Bar Tip styles are available. Please select one of the following<br />

tip styles and specify with your order. See above for drawing of the Ear Bar Tip Styles.<br />

9-YSTI-8<br />

Ear Bar Tip Styles<br />

Refer to the parts listed below for extras and replacements for your Ear Bar Tips.<br />

9-YSTI-1-8A Ear Bar Tip for .312 size Shank, Style A, set of 2.<br />

9-YSTI-1-8B Ear Bar Tip for .312 size Shank, Style B, set of 2.<br />

9-YSTI-1-8C Ear Bar Tip for .312 size Shank, Style C, set of 2.<br />

9-YSTI-1-8D Ear Bar Tip for .312 size Shank, Style D, set of 2.<br />

9-YSTI-1-8E Ear Bar Tip for .312 size Shank, Style E, set of 2.<br />

9-YSTI-1-8G Ear Bar Tip for .250 size Shank, Style G, set of 2.<br />

9-YSTI-1-8H Ear Bar Tip for .250 size Shank, Style H, set of 2.<br />

9-YSTI-1-8J Ear Bar Tip for .250 size Shank, Style J, set of 2.<br />

9-YSTI-1-8K Ear Bar Tip for .250 size Shank, Style K, set of 2.<br />

9-YSTI-1-8L Ear Bar Tip for .250 size Shank, Style L, set of 2.<br />

9-YSTI-1-8M Ear Bar Tip for .250 size Shank, Style M, set of 2<br />

Note: Ear tips not to size<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


YST STEREOTAXIC FRAME PARTS<br />

Refer to the list below for extras and replacement parts on your MRI Stereotaxic Frame. When<br />

selecting additional Eye or Ear Bars, please remember that they MUST match.<br />

As the model 22 is narrower at the base to accommodate a small bore MRI, a detachable base is<br />

available to provide a stable platform during surgeries.<br />

9-YST-1-X EYE BARS, EAR BARS & EYE BAR ASSEMBLIES<br />

9-YSTI-1-12 Eye Bars, Offset, Small 1/4” dia. formerly YIO-BS<br />

9-YSTI-1-12B Eye Bars, Offset, Large 5/16” dia formerly YIO-BL<br />

9-YSTI-1-11 Eye Bars, Straight, Small 3/8 x 3/16 bar, formerly YIL-BS<br />

9-YSTI-1-11A Eye Bars, Straight, Large 5/16” bar, formerly YIL-BL<br />

9-EYE BAR POSITION PLATES<br />

9-YSTI-1-9B Eye Bar Position Plate, Standard size<br />

9-YSTI-1-9A Eye Bar Position Plate, Small size<br />

9-YSTI-1-9C Eye Bar Position Plate, Nursery size<br />

9-EYE BAR POSITION PLATE ASSEMBLY<br />

These assemblies include the Eye Bars, Position Plate, the Locking Screw, Palate Bar and Main<br />

Block Attaching Screws. Eye Bars must Match Existing Ear Bars for Straight or Offset style.<br />

9-YSTI-1-119A<br />

9-YSTI-1-129A<br />

9-YSTI-1-119B<br />

9-YSTI-1-129B<br />

9-YSTI-1-119C<br />

9-YSTI-1-129C<br />

Eye Bar Position Plate Assembly, small, straight Eye Bars<br />

Eye Bar Position Plate Assembly, small, offset Eye Bars<br />

Eye Bar Position Plate Assembly, large, straight Eye Bars<br />

Eye Bar Position Plate Assembly, large, offset Eye Bars<br />

Eye Bar Position Plate Assembly, Nursery Size, straight Eye Bars<br />

Eye Bar Position Plate Assembly, Nursery Size, offset Eye Bars<br />

NEW<br />

9-YSTI-1-11C<br />

Anterior Reference Marker eye bars<br />

Also see Spare Parts Section for Small items; e.g. screws.<br />

All of the above Stereotaxic Frame Parts are made from Brass, Aluminum or Plastic.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


Note: Caution must be taken if using small animal ear bars or eye bars on larger animals. The points are<br />

smaller and may penetrate deep enough to cause ear damage. We strongly suggest that if using the standard<br />

frame for larger primates, order the larger size of Ear Bar ends. Standard rails for the Stereotaxic Frame are<br />

19 mm. 22 mm rails can be supplied if you have manipulators that fit this larger size. Ear Bars and Eye Bars<br />

must be matched at the time of purchase.<br />

9-YSTC-1 The Visual System Investigator<br />

The Visual System Investigator offers the ultimate in flexibility for visual systems studies of cats<br />

and monkeys. The experimental Animal’s eyes are allowed an unobstructed view to nearly 90<br />

degrees from central vision, while maintaining the ability to move in stereotaxic coordinates. This is<br />

accomplished by reversing the position of the animal in the carrier. Instead of a conventional<br />

straight piece connecting the side rails into a “U” shape, a generous curve allows greater room to<br />

accommodate larger experimental animals. The palate<br />

and eye clamps are mounted to a slot rail, which allows<br />

the clamps to be slid in from the side with minimal<br />

invasion of the visual field. A pair of specially machined<br />

“L” shaped ear bars allows a single investigator to easily<br />

secure the animal to the frame. The frame tilts forward to<br />

normalize visual receptive fields, and is made of anodized<br />

aluminum – compatible with applications requiring nonferrous<br />

metals. The side rails can be used with currently<br />

manufactured manipulators, which can be slid in from the<br />

front or back of the frame. Talk with a <strong>Crist</strong> <strong>Instrument</strong><br />

<strong>Co</strong>mpany sales person about your application and how<br />

the VSI can be tailored to suit your needs.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


9-YSTI-18 Stereotaxic Frame Parts<br />

Part No. Model Name/Material Works With<br />

9-YSTI-18-PA2 Main Block/Acrylic 9-YSTI-18<br />

9-YSTI-18-PJ4SL AP Bar, Small Left/Cilux 9-YSTI-18<br />

9-YSTI-18-PJ4SR AP Bar, Small Right/Cilux 9-YSTI-18<br />

9-YSTI-18-PJ5 Ear Bar Block/Cilux 9-YSTI-18<br />

9-YSTI-18-PJ7L Straight Ear Bar Left/Cilux 9-YSTI-18<br />

9-YSTI-18-PJ7R Straight Ear Bar Right/Cilux 9-YSTI-18<br />

9-YSTI-18-PJ7-ASSY Ear Bar Assembly/Cilux 2ea 9-YSTI-18<br />

9-YSTI-18-PJ9 Eye Bar Plate/Cilux 9-YSTI-18<br />

9-YSTI-18-PJ9-ASSY Eye Bar Assembly/Cilux 2ea 9-YSTI-18<br />

9-YSTI-18-PJ10 Pallet Bar/Cilux 9-YSTI-18<br />

9-YSTI-18-PJ11 Eye Bar/Cilux 2ea 9-YSTI-18<br />

9-YSTI-18-PJ15 AP Bar Supports/Cilux 9-YSTI-18<br />

9-YSTI-18-PJ16-S Leveling Screws/Cilux Set 9-YSTI-18<br />

9-YSTI-18-PA3 Base 9-YSTI-18<br />

9-YSTI-22 Stereotaxic Frame Parts<br />

Part No. Model Name/Material Works With<br />

9-YSTI-22-PA2 Main Block/Acrylic 9-YSTI-22<br />

9-YSTI-22S-PJ4L AP Bars, Small Left/Cilux 9-YSTI-22<br />

9-YSTI-22S-PJ4R AP Bars, Small Right/Cilux 9-YSTI-22<br />

9-YSTI-22-PJ15 AP Bar Supports/Cilux 9-YSTI-22<br />

Only<br />

9-YSTI-22-PA3 Base 9-YSTI-22<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


9-YSTI-27<br />

Part No. Model Name/Material Works With<br />

9-YSTI-27-PA2 Main Block/Plastic Acrylic 9-YSTI-27<br />

9-YSTI-27-PA2 Base 9-YSTI-27<br />

9-YSTI-30<br />

Part No. Model Name/Material Works With<br />

9-YSTI-30-PA2 Main Block/Plastic Acrylic 9-YSTI-30<br />

9-YSTI-30-PA3 Base 9-YSTI-30<br />

9-YSTI-35<br />

Part No. Model Name/Material Works With<br />

9-YSTI-35-PA2 Main Block/Plastic Acrylic 9-YSTI-35<br />

9-YSTI-35-PA3 Base 9-YSTI-35<br />

Universal Stereotaxic Frame Parts<br />

Part No. Model Name/Material Works With<br />

9-YSTI-1L-MA4L AP Bars, Large Left/Aluminum Universal to<br />

all Frames<br />

9-YSTI-1L-MA4R AP Bars, Large Right/Aluminum Universal to<br />

all Frames<br />

9-YSTI-1S-MA4L AP Bars, Small Left/Aluminum Universal to<br />

all Frames<br />

9-YSTI-1S-MA4R AP Bars, Small Right/Aluminum Universal to<br />

all Frames<br />

9-YSTI-1L-MA5 Ear Bar Block, Large/Aluminum Universal to<br />

all Frames<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


9-YSTI-1S-MA5 Ear Bar Block, Small/Aluminum Universal to<br />

all Frames<br />

9-YSTI-1L-PA5 Ear Bar Block, Large/ Cilux Universal to<br />

all Frames<br />

9-YSTI-1S-PA5 Ear Bar Block, Small/Cilux Universal to<br />

all Frames<br />

9-YSTI-1L-MA6B Offset for Ear Bars, Large 3/8 x 1/2”Rect/ Brass Universal to<br />

all Frames<br />

9-YSTI-1L-MA6-L Offset Ear Bars, Large Left 3/8” Square/ Brass Universal to<br />

all Frames<br />

9-YSTI-1L-MA6-R Offset Ear Bars, Large Right 3/8” Square/Brass Universal to<br />

all Frames<br />

9-YSTI-1S-MA6B Offset for Ear Bars, Small 3/8 x 1/2” Rect/ Brass Universal to<br />

all Frames<br />

9-YSTI-1S-MA6-L Offset Ear Bars, Small Left ¼” Square/ Brass Universal to<br />

all Frames<br />

9-YSTI-1S-MA6-R Offset Ear Bars, Small Right ¼” Square/ Brass Universal to<br />

all Frames<br />

9-YSTI-1L-PJ6B Offset for Ear Bars, Large 3/8 x 1/2” Rect/Cilux Universal to<br />

all Frames<br />

9-YSTI-1L-PJ6-L Offset Ear Bars, Large Left 3/8” Square/Cilux Universal to<br />

all Frames<br />

9-YSTI-1L-PJ6-R Offset Ear Bars, Large Right 3/8” Square/Cilux Universal to<br />

all Frames<br />

9-YSTI-1S-PJ6B Offset for Ear Bars, Small 3/8 x 3/8” Square/Cilux Universal to<br />

all Frames<br />

9-YSTI-1S-PJ6-L Offset Ear Bars, Small Left ¼” Square/Cilux Universal to<br />

all Frames<br />

9-YSTI-1S-PJ6-R Offset Ear Bars, Small Right ¼” Square/Cilux Universal to<br />

all Frames<br />

9-YSTI-1L-MA7L Straight Ear Bars, Large Left 3/8” Square/Brass Universal to<br />

all Frames<br />

9-YSTI-1L-MA7R Straight Ear Bars, Large Right 3/8 Square/Brass Universal to<br />

all Frames<br />

9-YSTI-1L-PJ7L Straight Ear Bars, Large Left 3/8” Square/Cilux Universal to<br />

all Frames<br />

9-YSTI-1L-PJ7R Straight Ear Bars, Large Right 3/8” Square/Cilux Universal to<br />

all Frames<br />

9-YSTI-1S-MA7L Straight Ear Bars, Small Left ¼” Square/Aluminum Universal to<br />

all Frames<br />

9-YSTI-1S-MA7R Straight Ear Bars, Small Right ¼” Square/Aluminum Universal to<br />

all Frames<br />

9-YSTI-1-PJ8-(A-Q) Ear Bar Tips (choose style)/Cilux, All come with Dye<br />

Markers<br />

Universal to<br />

all Frames<br />

9-YSTI-1-PJ9-FO Eye Bar Plate/Cilux, New Style Solid Offset Universal to<br />

all Frames<br />

9-YSTI-1-MA9-FO Eye Bar Plate/Aluminum, New Style Solid Offset Universal to<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


all Frames<br />

9-YSTI-1L-MA9-L Eye Bar Plate/Aluminum Long Universal to<br />

all Frames<br />

9-YSTI-1L-MA9-STD Eye Bar Plate/Aluminum Universal to<br />

all Frames<br />

9-YSTI-1L-PJ9-STD Eye Bar Plate/Cilux Universal to<br />

all Frames<br />

9-YSTI-1S-MA9-F Eye Bar Plate/Aluminum For Flat Eye Bars Universal to<br />

all Frames<br />

9-YSTI-1S-MA9-S Eye Bar Plate/Aluminum, Use with<br />

9-YSTI-1-MA12-S<br />

Universal to<br />

all Frames<br />

9-YSTI-10-MA11 Flat Eye Bar /Aluminum Universal to<br />

all Frames<br />

9-YSTI-10-MA11-S Flat Eye Bar /Aluminum Universal to<br />

all Frames<br />

9-YSTI-1L-MA11-S Flat Eye Bar /Aluminum Universal to<br />

all Frames<br />

9-YSTI-1-MA11-L Flat Eye Bar /Aluminum Universal to<br />

all Frames<br />

9-YSTI-1-PJ11 Flat Eye Bar/Cilux Universal to<br />

all Frames<br />

9-YSTI-1-PJ12 Offset for Flat Eye Bar/Cilux, Use with Eye Bar Plate<br />

9-YSTI-1-PJ9-FO<br />

Universal to<br />

all Frames<br />

9-YSTI-1-MA12-S Offset Eye Bars/Aluminum, Use with<br />

9-YSTI-1S-MA9-S<br />

Universal to<br />

all Frames<br />

9-YSTI-1-MA12 Offset Eye Bars/Aluminum, Use with<br />

9-YSTI-1L-MA9-STD or 9-YSTI-1L-MA9-L<br />

Universal to<br />

all Frames<br />

9-YSTI-1-MA12A Offset For Eye Bars/Aluminum, Use with Eye Bar<br />

Plate 9-YSTI-1-MA9-FO<br />

Universal to<br />

all Frames<br />

9-YSTI-1-MA13S Pallet Bar Lock for Cilux MRI, Use Thumb Screw Universal to<br />

all Frames<br />

9-YSTI-1-PN16 Leveling Screws/Nylon Fits all<br />

standard flat<br />

based<br />

9-YSTI-1-PJ17 Anterior Dye Marker/Cilux to level computer image Universal to<br />

all Frames<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


9-Spare Parts<br />

Part No. <strong>Co</strong>mponent Name & Parts<br />

Total per set<br />

Parts<br />

9-YSTI -01F Stereotaxic Parts Bubble Level 1<br />

9-YSTI-16 Leveling Screws 3<br />

Palate Bar Lock Screw, Brass<br />

1<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


CRIST INSTRUMENT COMPANY, INC.<br />

111 W. First Street<br />

Hagerstown, Maryland 21740 USA<br />

Telephone 1-301/393-8615 Fax 1-301/393-8618<br />

E-mail neurotoys@msn.com<br />

TECH BRIEF VOL. 1-3<br />

SINGLE CELL RECORDING SYSTEMS<br />

In the past, when working with single cells on chronically implanted primates, it has been difficult to establish that a<br />

given microelectrode penetration corresponds to particular electrode track on histological sections, or indeed, whether<br />

they were parallel. As a result of work done by Charles <strong>Crist</strong>, and Doctors Yamasaki, Komatsu and Robert Wurtz, a<br />

Grid System was developed to work in conjunction with microelectrodes, Guide Tubes and a Recording Microsyringe<br />

for chemical injections. The success of this system has resulted in it’s becoming a standard for use in the research<br />

environment when accurate mapping or lesion placement is required.<br />

<strong>Crist</strong> <strong>Instrument</strong> had the Grid System (6-YGD-D1, 6-YGD-J1, 6-YGD-D2 and 6-YGD-J2) with Guide Tubes<br />

and Grids available for this type of study since early testing proved the efficiency of this apparatus. We worked on a<br />

method for commercially producing the Recording Microsyringe that was brought to the marketplace in June 1992.<br />

Since that time, it has been proven a highly effective device for simultaneous recording and injection of various<br />

substances in a single cell site. This brief describes the use of the Grid System and the Recording Microsyringe (3-<br />

MRM-S02).<br />

The <strong>Crist</strong> Grid System uses a “Grid Cup” that fits within the grid holder (Chamber Adapter) and an implanted<br />

Recording Cylinder. The Grid is made from Delrin or CILUX to keep it light in weight and also invisible to the MRI. It<br />

has an outside diameter of 19.05 mm and an inside diameter of 16.80 mm. The grid area consists of a format of 221<br />

holes spaced 1 mm apart on the X-Y plane. It is in a well deep enough to stabilize a thin walled Guide Tube (6-YGTSxx,<br />

for Guide Tubes up to 60 mm, or 6-YGTSA-xx for Guide Tubes over 60 mm) holding it virtually rigid. The Guide<br />

Tube is sufficiently large to allow the passage of a thin tungsten microelectrode or the Recording Microsyringe. The<br />

holes in the grid also accommodate thin platinum-iridium microelectrodes used for exploration. We recommend when<br />

using the grid that it be aligned stereotaxically to the Recording Chamber. This allows the grid assembly to be removed<br />

and replaced repeatedly, still maintaining it’s anterior - posterior position. The Adapter (Smokestack) has three slots for<br />

the key pin located on the Recording Chamber. This allows a rotation of 30-degree steps of the grid with three times the<br />

penetration sites. Chamber Adapters and Head Holders are made from high quality 316 Stainless Steel or from CILUX.<br />

Guide Tubes are all custom cut to length with a squared off end and a flared top to facilitate insertion of the<br />

microelectrode.<br />

The Recording Microsyringe (3-MRM-S02) uses a modified Hamilton Syringe with an extended recording<br />

barrel. The wire is thin enough to allow the flow of relatively high viscosity solutions through the barrel. The wire<br />

extends .750 mm beyond the tip of the tube to prevent tissue displacement from interfering with recordings. Wire<br />

impedance measure in a range of 0.3 and 1.0 micro ohm at 1000 Hz. The Recording Microsyringe permits the<br />

occurrences of simultaneous single unit recordings and injections of various substances. It is possible to create a<br />

temporary or permanent lesion at or near a single neuron and observe the changes, which occur. Lesion effectiveness is<br />

measured with immediate response as the active neuron signal changes or ceases to fire. For convenience and cost, we<br />

are packaging the Recording Microsyringe in units that consist of three recording barrels and one modified Hamilton<br />

syringe.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


CRIST INSTRUMENT COMPANY, INC.<br />

111 W. First Street<br />

Hagerstown, Maryland 21740 USA<br />

Telephone 1-301/393-8615 Fax 1-301/393-8618<br />

E-mail neurotoys@msn.com<br />

TECH BRIEF VOL. 2 - 1.2<br />

ADAPTING THE SINGLE CELL RECORDING SYSTEM FOR USE WITH<br />

THE MRI<br />

AND UPDATES OF OTHER APPARATUS<br />

Because of increasing interest in the use of MRI to locate exact areas of the brain for study<br />

and to verify the location of head holders and cylinders after attachment, we have designed and are now<br />

producing a line of non-magnetic products expressly for use with MRI equipment. These items include our<br />

“0” degree and angle chambers, which are similar in style to the Evarts’ cylinder (6-ICO-J0, 6-ICO-J2A, 6-<br />

IAM-J0 & 6-IAM-JA); the Head Holder on the Head (6-FHP-J1, J6 & J4), the Head Post (6-FHP-X2 & B2),<br />

the Head Positioner on the Chair (FHD-J9) and the matching Head Holder on the Head (6-FHP-J9), as well as<br />

the Chamber to Microdrive Adapter, “Smokestack” (6-YNP-S3 & 6-YNP-J3). These are all comparable to<br />

our Stainless Steel devices for the same purpose, although some minor design changes were necessary.<br />

In addition to the standard size line of cylinders and head holders we have also developed a<br />

new line of head holders in 316 Stainless Steel (not for MRI use), Titanium and CILUX for small animals (6-<br />

FHP-J6 and 6-FHP-J4) such as rats, rabbits, cats and new world monkeys. We have also designed a new<br />

Head Holder on the Chair (6-FHC-S6 and 6-FHC-S4) for smaller and lighter animals and the 6-FHC-S5 to<br />

work with the Mini Chairs (1-CM).<br />

The latest addition to our repertoire of useful products is the Adjustable Head Positioner (6-<br />

FAC-SB series). It swivels, it pivots and turns to the position you need. With this unit the Head Holders for<br />

the Head can be placed in almost any position or location you require for your investigations.<br />

For your convenience, store your microdrive adjacent to your work center in a Microdrive<br />

Storage Box (3-MMD-P1). The box hangs on a wall near your work center or hangs underneath a shelf. It<br />

has a specifically designed hanger for your Microdrive. Leave it connected, hang it up. The box is<br />

constructed of plastic with Stainless Steel hinges and a Brass door latch.<br />

Of course, the Stereotaxic for MRI (6-YSTMRI-10 or 6-YSTMRI-22) will be a must. It is<br />

made from plastic, with aluminum side bars and brass ear, eye and palate bars.<br />

When it is freedom to work as you need you need to think of <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>., Inc.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


CRIST INSTRUMENT COMPANY, INC.<br />

111 W. First Street<br />

Hagerstown, Maryland 21740 USA<br />

Telephone 1-301/393-8615 Fax 1-301/393-8618<br />

E-mail neurotoys@msn.com<br />

Tech Brief Vol. V-2.2<br />

NEW MRI COMPATIBLE PRODUCTS<br />

The <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>mpany is a leading provider of MRI compatible implant devices for<br />

single cell recording. We have recently begun using a new material we call CILUX. It has<br />

properties that are far superior to the reinforced Delrin used previously. It is stronger and more rigid<br />

than the Delrin. As a result, screws hold firmly for a longer period of time. This product can be<br />

autoclaved without absorbing water and it appears to retain its shape and dimensional stability. This<br />

is a product with greater endurance and strength. The products available in this new material include<br />

Recording chambers from “0” to 45 degrees of angle, now in two models; Chamber Caps; Implant<br />

Screws; Grids, both Standard and Offset; Head Holders and Ear Bar tips for the MRI Stereotaxic<br />

Frame. Because of higher material costs and additional matching costs to manufacture, these<br />

products are being offered at a slightly higher price than the Delrin.<br />

The CILUX Recording Chambers are available in two styles. One style is made with<br />

opposing nylon screws; the other is similar to the stainless steel chamber and is made with set<br />

screws.<br />

<strong>Co</strong>ntinuing with our MRI compatible products, we are now providing a new brass or titanium<br />

Head Post (6-FHP-B2 and 6-FHP-X2). The head Post Pin is designed with tapered sides on the pin<br />

that fit into a vertical slot on the Chair Mounted Universal Head Positioner. A pin prevents vertical<br />

movement in the slot and the tapered sides prevent any torsional movement. The assembly is held<br />

with a single screw. Adapters are also available to make these compatible with our standard Head<br />

Positioner on the Chair 6-(FHC-S2, 6-FHC-S6 and 6-FHC-S4). Extreme care must be taken when<br />

using any brass material in this type of research. At no time may the brass make contact with living<br />

tissue. The brass must be FULLY encapsulated in the dental acrylic. Using brass and titanium for<br />

MRI studies reduces, but does not eliminate the broad shadowing of metals in the MRI field. For<br />

this reason, care should be taken in positioning any metal parts near those areas you are interested in<br />

examining in the MRI. While the <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>mpany, Inc. is aware that brass head posts are<br />

in common use in some laboratories, the <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>mpany, Inc. does not fully endorse or<br />

accept the responsibility for any deleterious results ensuing from the use of brass so closely<br />

conjoined with biological material. But, being fully aware of the limited funds available in research,<br />

we are willing to supply these products with the understanding that the use of these products is<br />

solely the responsibility of the investigator.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


CRIST INSTRUMENT COMPANY, INC.<br />

111 W. First Street<br />

Hagerstown, Maryland 21740 USA<br />

Telephone 1-301/393-8615 Fax 1-301/393-8618<br />

E-mail neurotoys@msn.com<br />

TECH BRIEF VOL. 3-1<br />

STEREOTAXIC AND RELATED EQUIPMENT FOR THE MRI<br />

The response to our Tech Brief Vol. 2-1, adapting the Single Cell Recording System for use<br />

with the MRI, has created significant interest. Those responses have encouraged us to develop a<br />

MRI compatible Stereotaxic. It incorporates features consonant with the Kopf, with the addition of<br />

MRI compatibility and dye markers in the ear bars to provide a fiducial mark in the MRI display.<br />

The standard model for use with macaques comes with offset ear and eye bars. Straight ear and eye<br />

bars are available. These are recommended for use with small animals such as cats or new world<br />

monkeys.<br />

We have placed dye markers visible to the MRI in the ear bars to provide you with a<br />

reference when selecting the area for making your recordings more accurately. The vitamin E used<br />

as a dye marker is clearly visible on the MRI imaging screen. It will not cause any disturbance or<br />

loss of clarity to the image. The ear bars also have graduations one millimeter apart with a fiftymillimeter<br />

range for precise centering of the subject.<br />

The fixed eye bars position the lower eye sockets even with the aural canal. Adjustable eye<br />

bars are available so you may use any tilt angle you desire. We recommend the use of a preset<br />

incisor contact device mounted in your manipulator to obtain a degree of repeatability when using<br />

other that the “0” angle.<br />

The side bars are graduated one millimeter apart, one hundred millimeters in each direction<br />

from “0” at the ear bar center line. This allows for accurate positioning of manipulators when doing<br />

operations similar to those done in normal surgery. In fact, this device can be used in place of your<br />

regular surgical set up.<br />

If you use manipulators in this or any similar Stereotaxic apparatus, we have available a very<br />

inexpensive centering and positioning device (6-ST03). This will set the X-Y- and Z Zero (0)<br />

reference of your pointer system in your manipulators.<br />

In addition to the MRI Stereotaxic, we developed a dye marker system integrated into our<br />

Standard Guide Tube Grid. When used with our Recording Chamber (6-IAC and 6-ICO, nonmagnetic<br />

series) and the Chamber to Microdrive Adapter (6-YNS and 6-YNP series), which holds<br />

the Grid in place. MRI studies can be performed after surgery to verify exact positioning and the<br />

correct orientation of your surgical implants. Four dye markers are provided in the x-y coordinate<br />

positions of the Grid (6-YGD and 6-RGP series). These can be used to delineate the positioning and<br />

angle of alignment of the Guide Tube Grid. For information on the use of the Single Cell Recording<br />

System, refer to our Tech Brief, Volume 1-3.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


CRIST INSTRUMENT COMPANY, INC.<br />

111 W. First Street<br />

Hagerstown, Maryland 21740 USA<br />

Telephone 1-301/393-8615 Fax 1-301/393-8618<br />

E-mail neurotoys@msn.com<br />

TECH BRIEF VOL. 3-2<br />

Liquid Reward System (RLDE1 or RLDE2)<br />

The liquid reward system that we manufacture is as versatile as we can possibly make it. It consists<br />

of two models, the delivery tube (5-RLD-00A); the controller, which comes in either a 19” panel mount (5-<br />

RLD-E1) or a free standing box (5-RLD-E2) that can be placed on the table or shelf and the dispenser units<br />

(5-RLD-E1C, E2C) which mount on the wall or a shelf high enough to provide gravity feed. A stand is also<br />

available for the dispenser unit.<br />

The controller utilizes eight time selections to control the amount of reward given. The operator or<br />

the computer can control any one of these eight selections. In addition, there is a selection that allows the<br />

duration to be completely controlled by the computer. The selection of when to give the reward can be<br />

controlled manually by the operator or a five-volt TTL signal from the computer. The operator has two<br />

options in triggering the reward; one is a push button on the panel (box) or a remote cable switch. Input from<br />

the computer can be with a BNC connector or two banana plugs. An audible signal is provided on the panel<br />

as well as on the dispenser unit. The volume of these audible units can be controlled by adjustable<br />

potentiometers accessible on the back of the panel or inside the box. <strong>Co</strong>ntrol is also provided to select either<br />

one or both of the audible devices. This equipment operates from standard 110-volt supply line. All power<br />

supplies necessary for the operation of the equipment are built in. For systems using other voltages we can<br />

change the transformer to accommodate your needs. Please advise when you place your order.<br />

The dispenser unit consists of a liquid container, rapid response solenoid, drain switch and the audible<br />

device. These elements are mounted securely to the panel. The freestanding control box model comes with a<br />

stand for the dispenser unit that can be set on a shelf. Units include either a twenty-five foot or a fifteen foot<br />

control cable, with connector. If a longer cable is required, it must be requested at the time of order. Five feet<br />

of Tygon tubing (1/8”) is provided to connect to the feeder tube. If more is needed, it must be requested at the<br />

time of the order.<br />

The feeder tube is approximately seventeen inches long (43 cm) and is made from stainless steel hypo<br />

tubing. It terminates with a molded mouthpiece made of dental acrylic with two vacuum breaker tubes on<br />

either side. The design is such that a drop coming from the main tube will be supported briefly by the<br />

vacuum breaker tubes. The vacuum breaker tubes prevent the subject from siphoning the water or other liquid<br />

from the system. Also included is a mounting block and clamp. We feel the tube is long enough to be bent<br />

carefully by hand to position near enough to the subjects mouth that they can, with little or no effort, receive<br />

the reward as it is given. We highly recommend purchasing extra feeder tubes. This will permit continued<br />

use of the system while one is being cleaned.<br />

Even with the versatility we have designed into our equipment, we realize there are variations and<br />

changes that may suit your needs more precisely. We offer our services in modification to any and all<br />

equipment manufactured by <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>., Inc. Please contact us for your special needs.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


CRIST INSTRUMENT COMPANY, INC.<br />

111 W. First Street<br />

Hagerstown, Maryland 21740 USA<br />

Telephone 1-301/393-8615 Fax 1-301/393-8618<br />

E-mail neurotoys@msn.com<br />

TECH BRIEF VOL. 5-1<br />

ISOLATION BOOTHS<br />

Because of the growing trend toward multiple, on-going experiments in a single room, the <strong>Crist</strong> <strong>Instrument</strong><br />

<strong>Co</strong>mpany has developed a line of Isolation Booths for both vision, hearing, behavioral or other types of research. These<br />

booths are designed to restrict to a minimum the outside distractions to the experiment in progress within the booth.<br />

The vision and behavioral booths are designed to work with interactive Touch Screen Monitors and/or provide<br />

space for scleral coils used in tracking cicads during single cell recordings. Access is provided for loading the animal<br />

and chair through the rear. An additional opening is provided on the side (right or left) to perform the necessary<br />

investigator tasks in setting up the experimental equipment. Additional access is provided in the top for insertion of<br />

microdrives, water tubes or electronic cabling. A track with sliding base facilitates easy positioning of the chair in<br />

relation to the Monitor Screen. The chair clamps on to the base and an adjustable lock positioner holds the base in place<br />

during the experiments. A shelf is included on the outside for mounting a Touch Sensitive Monitor at the vision port or<br />

to provide a platform for tasking. This shelf is adjustable to accommodate the various models and sizes of Monitors or<br />

other devices.<br />

Audio booths are similar in design without the video port. They are provided with sonex sound attenuating<br />

foam on the inside surfaces. Facilities can be provided for a variety of speakers and speaker positions within the box.<br />

Because it is important that the chair has no barriers to the surrounding sound, if the animal’s head must be held in some<br />

fixed position, a head holder can be mounted to the top of the box. This allows for a full 360 degree sound clearance to<br />

the audio canal. Audio booths, because of the added sound attenuation material are generally constructed somewhat<br />

larger and are usually preferred to be square rather than rectangular along the base dimension. Similar to the vision<br />

booth, there is a rear loading and side access so the investigator can set up the equipment and position the animal for a<br />

variety of experiments.<br />

All booths are constructed of wood with foam fillers and completely covered on all surfaces, inside and out,<br />

with water proof, easy to clean Formica. Booths come in a variety of sizes to meet individual protocols. All of the<br />

elements of the booth are precision cut and pre-assembled to verify fit. The booths are shipped assembled but because of<br />

the size generally required for the audio booths, they may require disassembly to fit through a standard door. Units can<br />

be provided with or without locking castors. Without the castors, the unit sits directly on the floor. If they must be<br />

moved frequently for cleaning or to move experiments from one place to another, we recommend the castors. In general,<br />

most laboratories set them up in an appropriate system for both experimental ease and convenience in the room. When<br />

ordering your booth you can also select your Formica color options in standard black, or white.<br />

The <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>mpany is able and willing to custom design any shape or size isolation booth or<br />

Wisconsin box that you may require. As with all laboratory set-ups on site installation services are available. We<br />

particularly recommend site installation for the larger units. These boxes can be fabricated with a variety of options, see<br />

our catalog, Section 8.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


CRIST INSTRUMENT COMPANY, INC.<br />

111 W. First Street<br />

Hagerstown, Maryland 21740 USA<br />

Telephone 1-301/393-8615 Fax 1-301/393-8618<br />

E-mail neurotoys@msn.com<br />

TBV Vol. XII-1.1<br />

Miniature Microdrives<br />

Miniature Microdrives are devices for performing single or multiple cell recordings in small<br />

mammals. They are manually operated. We make two types of Miniature Microdrives, The Biela<br />

model (3-MMB-1) and the Miniature Model (3-NRMD series).<br />

The Biela Microdrive uses a unique system to provide non-rotating linear movement of the<br />

electrode. It is designed to be used with either four each glass micropipette electrodes, a bundle of<br />

fine wire electrodes or a single electrode. The electrodes pass through the device and are insulated<br />

by Teflon tubing (glass pipettes do not require the insulation). One full turn of the thimble results in<br />

.0156 inches (approximately .4 mm) of advancement of the electrode. The electrode is normally<br />

fastened with duco cement or a small amount of acrylic to the insulating tube that protrudes through<br />

the top center of the thimble. The microdrive is mounted on the subject’s head with a threaded<br />

mounting device fastened with acrylic. The microdrive then becomes removable when not in the<br />

experimental set up. A cap with plug is provided to seal the mount to prevent debris or infection<br />

from reaching the surface of the brain. It is normally used on anesthetized animals; but can be used<br />

in awake animals if they are appropriately restrained.<br />

Another situation where the Biela Microdrive can serve as a useful research tool is with a<br />

mount that fits inside of 6-YGD-D1, Standard Grid, or the 6-YGD-D2, Offset Grid. This would be<br />

used in awake monkeys for long-term chronic implants in a situation where you would need to move<br />

the electrode from one position to another without changing the X-Y location. To change the X-Y<br />

location retract the electrode into the guide tube, remove and select another hole in the grid to start<br />

another series of depth recordings. We also have available a double eccentric mount that is not used<br />

with the grid but allows for wide coverage and many penetration sites in a cylinder that is 34 mm<br />

inside diameter.<br />

The Miniature Microdrive (3-NRMD) is a different style of manually operated microdrive,<br />

which comes with six options. This permits a multitude of ways this unit can be utilized. For<br />

example, attach it inside the Standard (6-YGD-J1) or Offset (6-YGD-J2) Grids. When the Grid is<br />

inverted one or more microdrive units can be attached. For placement within the Grid one can use<br />

either the model with the Asymmetric Foot or with the Symmetric Foot. Each of those styles comes<br />

with optional 1, 2, or 3 Electrode Holders.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


CRIST INSTRUMENT COMPANY, INC.<br />

111 W. First Street<br />

Hagerstown, Maryland 21740 USA<br />

Telephone 1-301/393-8615 Fax 1-301/393-8618<br />

E-mail neurotoys@msn.com<br />

Tech Brief Vol. XII-3.1<br />

Recording Chambers, Caps and Adaptors<br />

<strong>Crist</strong> <strong>Instrument</strong> has been a major provider of Recording Chambers, Caps, Adaptors and<br />

Grids for many years. They have been designed to permit a wide variety of choices when studying<br />

the brain. Recording Cylinders recommended by <strong>Crist</strong> <strong>Instrument</strong> are available for “Single Cell”<br />

and “Multi Cell” recordings in either the near term or the chronic environment. Caps provide a<br />

protective cover to the dura when placed atop the Recording Chamber. The Adaptor is the holder for<br />

the Grid and serves as the interface between the Chamber and the Microdrive. The Grid is the device<br />

that provides accurate spacing (1mm) and alignment (A/P) of the penetration sites when performing<br />

single and multi cell recordings.<br />

Recording Chambers (Cylinders) can be placed on the skull in a number of different<br />

locations. This is achieved by varying the angle at the base of the cylinder from “0” degrees to “45”<br />

degrees. “0” degree Chambers can be placed on the flat area of the skull to achieve vertical<br />

positioning or can be placed on the side of the skull for compound angle or straight in penetrations.<br />

Angle Chambers are used principally to provide a pattern with a common plane, i.e. horizontal; even<br />

when working to the periphery of the skull. These devices are attached during surgery using the<br />

Cylinder Alignment Tool (6-YSC-S2J or 6-YSC-S2S) the materials they are available in include 316<br />

Stainless Steel or CILUX. Bases of the Chambers are knurled to provide grip when attaching to the<br />

skull with acrylic. Stainless Steel units have an overall diameter of 7/8 inch (22.2 mm) with an<br />

inside diameter (id) of 3/4 inch (19 mm). The overall height of the “0” Chamber is 5/8 inch ( ). The<br />

CILUX devices overall diameter is a bit larger 1 inch (25.3 mm) to provide extra strength in the<br />

plastic and the id is 3/4 inch (19 mm). The height of the “0” degree Chamber is .75 inch ( ). Angle<br />

Chambers are measured in a minus direction from horizontal anti clockwise for what ever angle up<br />

to 45 degrees. The length of the short side of the chamber is the same as the “0” Chamber in the<br />

respective material. The “New MRI Style” made from CILUX has two opposing nylon screws for<br />

securing the grid in the chamber. This requires hand drilling into the CILUX Grid for the screws to<br />

grip. Many clients prefer this type of set up. It has the following drawbacks, it is difficult to remove<br />

the Grid and realign it in the same place when you want to clean the dura. The advantage appears to<br />

be use of a shorter chamber, i.e. without adaptor. There is also a Pin Style that uses 3-cone point set<br />

screws to secure the grid in the Adaptor. The removable pin style adaptor is preferred due to its<br />

repeatability when removed and replaced.<br />

The adaptor is made either of CILUX or 316 Stainless Steel. The adaptor also has the option<br />

of 3 additional positions, increasing the penetration sites. When you remove the adaptor the grid is<br />

locked inside it in a pre-selected position.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


CRIST INSTRUMENT COMPANY, INC.<br />

111 W. First Street<br />

Hagerstown, Maryland 21740 USA<br />

Telephone 1-301/393-8615 Fax 1-301/393-8618<br />

E-mail neurotoys@msn.com<br />

TECH BRIEF XIII-1.4<br />

MRI Primate Chair<br />

The <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>., Inc. in collaboration with Varian <strong>Co</strong>rporation have developed a vertical<br />

design for primate chairs to be used with Awake monkeys in the MRI/FMRI. The chair consists completely of<br />

non-metallic materials including the head holding and positioning apparatus mounted to a cylindrical body.<br />

As many MRI machines are horizontal <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>., Inc. also developed a horizontal model. The two<br />

models; one for the horizontal bore MRI and one for the vertical bore MRI machines can be designed and<br />

fabricated in sizes to fit the bore of your machine. The current models accommodate primates between 7 to 9<br />

kilos. Other sizes may be custom designed if your need exists. All MRI chairs are built to order upon receipt<br />

of purchase order. This is necessary due to the lack of tolerances in available materials.<br />

Working within strict parameters, we have found that CILUX is an adequately strong material to<br />

manufacture the head post and its supporting structure. The design we have used allows for some<br />

manipulation of the head position. The Head Holder on the Head combines with the stem that is held in the<br />

positioning structure of the chair in a reliable and error free Anterior/Posterior position.<br />

Both models are tubular in shape and have an overall outside diameter from 10 ½ inches (26 ¾ cm) to<br />

12 ½ inches. The horizontal chair is carried on a cradle in the horizontal position such that the head of the<br />

animal can be inserted into the MRI for studies. The monkey would be looking toward the rear of the magnet<br />

tube where it can be presented with a variety of stimuli. MRI Chair Models (1-CCM-V and 1-CCM-H)<br />

include: A removable waste tray; the Head Holding and positioning apparatus; an adjustable Perch Bar for<br />

standing or kneeling; ventilation holes in the rear of the chair and other features. One Interlocking MRI Style<br />

Chair Positioner on the Chair (6-FHD-J9) is also included; however, if extra units are required, they can be<br />

purchased separately. One matching Interlocking Head Holder on the Head (6-FHP-J9) is also included. One<br />

of these units is required for each research subject used in the MRI Chair. The Interlocking MRI Style Chair<br />

Positioner and the Interlocking Head Holder on the Head are made from CILUX.<br />

The MRI tube (bore) diameter is the controlling factor. Options include a rear door that provides<br />

access to the animal. Other options can be designed to meet specific investigator needs.<br />

These chairs have been carefully designed for normal use and cleaning. Few parts need to be removed<br />

from them, nearly eliminating the chance of lost or misplaced parts, including bolts. As always, there are no<br />

sharp edges anywhere on our chairs. For technical assistance and comments or technical suggestions, contact<br />

Mike <strong>Crist</strong>, Chair Department, or Chuck <strong>Crist</strong>, V. P. Engineering.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


CRIST INSTRUMENT COMPANY, INC.<br />

111 W. First Street<br />

Hagerstown, Maryland 21740 USA<br />

Telephone 1-301/393-8615 Fax 1-301/393-8618<br />

E-mail neurotoys@msn.com<br />

TECH BRIEF Vol. XIV-1.3<br />

PRIMATE CHAIRS<br />

<strong>Crist</strong> <strong>Instrument</strong> is known to make one of the most versatile primate chairs for your research<br />

requirements. We manufacture these chairs with the primate’s health and well being in mind while<br />

facilitating diverse usage by the researcher. Many of our chairs presently come in a variety of different<br />

models and sizes to fit your experimental protocols. Because of our many years of experience with a number<br />

of laboratory environments you may find existing models that meet your needs. You will find that many of<br />

the features are present in each of the different models and sizes. In some cases you may want to select<br />

features present in one chair and incorporate them on another. If that is what you need, we will find a way to<br />

do that also. In addition, since our chairs are semi-custom, we can design a chair to meet your unique needs<br />

when models featured in our catalog are not appropriate for your protocols.<br />

Our chairs are made from high impact polycarbonate with corners that are reinforced with our custom<br />

aluminum frame to minimize cracking of the plastic. For the researcher this translates into a tough, sturdy<br />

chair, which can be cleaned and sterilized. In addition, all parts are replaceable. This permits easy changes<br />

and modifications as your research progresses; or, if a part is damaged, replacement of that part only.<br />

Because health and safety are a prime consideration, many features are designed into all chair models<br />

to meet the highest standards. For example there are no sharp edges to come in contact with the animal. The<br />

Neck Plates were designed to provide restraint while allowing full mobility of body and limbs. It provides a<br />

range of positions without chafing when properly adjusted. The fully adjustable platform (Perch) allows the<br />

primate to crouch comfortably and naturally. This design aides in the prevention of atrophy and strain on the<br />

leg muscles. It is fabricated of stainless steel and aluminum to provide a continuity contact point for the use<br />

of a Touch Bar or other sensor. Another unique feature in all of our chairs includes the waste tray which is<br />

easy to remove without disturbing any of the chair settings or the comfort of the animal while experiments are<br />

in progress; thus, providing greater health and cleanliness for both the primate and the researcher. There are<br />

presently five distinct models and four different sizes. For example the spacious 10” x 10” x 23” compartment<br />

of the Standard size chair provides ample room for primates up to 9 kilograms. Most Models are ordered with<br />

either the Travel Trolley or the Taller Base and can be easily removed and reattached as needed.<br />

Our smallest chair, the MINI CHAIR, was designed by <strong>Crist</strong> <strong>Instrument</strong> staff to contain Squirrel<br />

Monkeys and similar size primates. Between the MINI Chair and our STANDARD Chair, that holds primates<br />

between 6 and 9 kilos, is our SMALL Chair made for primates ranging in weight from 2 to 6 kilos. The<br />

LARGE chairs have compartments capable of containing primates up to 15 or 16 kilograms.<br />

The Training or Vision Chair (one of our most popular models) comes in all four sizes, Standard,<br />

Small, Large and Mini for New World Monkeys. These Chairs all come with a Touch Bar built into the front<br />

panel as standard equipment for training and for eye-hand responses. The Side Head supports and Top Plate<br />

are designed to provide maximum rigidity and stability in holding the head in a fixed position, even when the<br />

monkey is moving about in the chair. This head brace can be modified in a number of ways to accommodate<br />

a variety of experimental modes. This Chair comes standard with the Tall Base, which includes large 5”<br />

locking swivel casters making it easy to roll over thresholds and elevator entries. The Tall Base Model places<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


CRIST INSTRUMENT COMPANY, INC.<br />

111 W. First Street<br />

Hagerstown, Maryland 21740 USA<br />

Telephone 1-301/393-8615 Fax 1-301/393-8618<br />

E-mail neurotoys@msn.com<br />

the eye height of your primate at approximately 47 to 48 inches from the floor. The base is pre-drilled to<br />

accommodate the Chair Positioner (1-V-50 series) for attaching to the floor. For those who prefer, the Travel<br />

Trolley is available. It has a 2-inch non-locking caster and is an excellent choice when using our Isolation<br />

Chamber.<br />

Another popular model is very similar except the Touch Bar is attached to a removable panel. This<br />

panel can be exchanged for a Joy Stick or other device. Normally it includes a low transport trolley instead of<br />

the taller base. This chair can be easily removed from the Trolley and inserted into an Isolation Chamber or<br />

other activity module. It is also available in the same four sizes.<br />

The TV Front Model is the perfect choice for behavioral or other studies that require some tasking or<br />

the use of a Touch Sensitive TV Screen. The basic design model controls which hand is to be used for<br />

reaching out; the left, the right or both hands can be tested. This model also includes a waist restraint to<br />

prevent the extension of feet through the front opening. When transporting from place to place, the Safety<br />

Barrier Plate keeps hands and feet inside. TV models are available in four sizes with either the Travel Trolley<br />

or the Tall Base.<br />

When large movements are required of arms or legs the Open Front and Sides Model is the one to<br />

select. It is the perfect choice when “reach out”, and manipulative tasks to the side are required. The “Open”<br />

Chair does not include head restraints; but, they can be added if needed. This model also features the Waist<br />

Restraint and comes with a Travel Trolley. This chair is presently made to accommodate the 4 to 9 kilo<br />

monkey. Tall Bases are available upon request as part of your individual requirements.<br />

Last, but not least in this line up of chairs is the model built for Audio Studies. It is very similar to<br />

the Standard Training Model. Its differences include a front opening door and the Special Base, which<br />

supports a Rear Head Restraint. This permits approximately 350 degrees of unobstructed work area in the<br />

horizontal plane. We believe that the vertical work range extends from “0” at the top of the chair to<br />

approximately 30 degrees below horizontal due to the interference of the chair main body. Several variations<br />

of this Chair exist as well.<br />

When none of these models are quite right for your individual needs please call our engineer. We<br />

will be happy to discuss your Chair requirements with you. To receive a more detailed list of chair<br />

components, as well as other equipment and apparatus manufactured by <strong>Crist</strong> <strong>Instrument</strong>, complete the<br />

attached mailer. We look forward to assisting with your research needs.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


CRIST INSTRUMENT COMPANY, INC.<br />

111 W. First Street<br />

Hagerstown, Maryland 21740 USA<br />

Telephone 1-301/393-8615 Fax 1-301/393-8618<br />

E-mail neurotoys@msn.com<br />

TECH BRIEF VOL. XIV-3.3<br />

RECORDING CYLINDERS, GRIDS AND ADAPTERS<br />

<strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>., Inc. has been a major provider of Recording Chambers, Caps, Adapters<br />

(Smokestacks) and Grids for many years. They have been designed to permit a wide variety of choices when<br />

studying the brain. Recording Cylinders manufactured by <strong>Crist</strong> <strong>Instrument</strong> <strong>Co</strong>., Inc. are available for single<br />

cell and multi-cell recordings in either the short term or the chronic environment. Caps provide a protective<br />

cover to the dura when placed atop the Recording Chambers. The Adapter is the holder for the Grid and<br />

serves as the interface between the chamber and the micro-dive. The Grid is the device that provides precise<br />

spacing (1mm) and alignment (A/P) of the penetration sites when performing single and multi-cell recordings.<br />

Our Chambers, Caps, Adapters and Grids are available in a variety of styles and materials.<br />

Recording Chambers (6-IAC-S0 and SA, 6-IAM-J0 and JA, 6-ICO-J0 and JA, 6-ISM-J-xx, and 6-<br />

ISC-xx series) are available in one or more of the following materials: 316 Stainless Steel, Titanium or<br />

CILUX. All of our cylinders include knurled bases to facilitate attachment to the acrylic skullcap. The<br />

Stainless Steel units have an overall diameter of 7/8” (22.2 mm) with an i.d. of ¾” (19 mm). The height of<br />

the stainless steel units is 5/8” (16 mm). This also applies to the Titanium Chambers. The CILUX units have<br />

an overall diameter of 1” (25.3 mm) and an i.d. of ¾” (19 mm). CILUX Chambers have a height of ¾” (19<br />

mm). Chambers have been made from Stainless Steel for years and are highly reliable. Titanium and CILUX<br />

are both used in the FMRI. CILUX, of course, is the most transparent. Titanium is useful in the MRI if it is<br />

located far enough away from the target site to avoid the shadowing that occurs.<br />

We have one style Stainless Steel Chamber (6-IAC-S0, “0” degree, and 6-IAC-SA-xx, Angled degree<br />

to 60”). These chambers are sturdy and rugged. They will last many years and can, with thorough cleaning,<br />

be reused. When placing the Grid in the Chamber the same technique is used as described below for the MRI<br />

Pin Style Chamber. The only drawbacks are their greater weight and the fact that they cannot be used in MRI<br />

equipment.<br />

There are two MRI style Chambers. Each style uses a different option for securing the Grid within<br />

the Chamber. The older style (6-ICO-J0 and JA-xx) uses two screws that screw directly to the Chamber and<br />

into the Grid. This method is not as precisely repositioned when the Grid has to be removed to clean or<br />

scrape the dura. The MRI style with opposing screws does not require an adapter. The microdrive mounts<br />

directly on to the Chamber. The Pin Style MRI Chamber (IAM-J0 and IAM-JA) is especially good for<br />

accurate repositioning of the grid in the same place every time. In addition, it offers three more positions for<br />

the Grid thereby tripling the number of penetration sites. The Grid Adapter grips the grid with three cone<br />

point screws. We recommend when turning the screws that the investigator does not over-tighten. The grid<br />

slides down into the Chamber until it is positioned with the Grid Adapter on the outside of the Chamber and<br />

three more cone point screws grip the ring groove around the top of the Chamber. (Again do not over-tighten<br />

these screws.) As stated before, this system is extremely reliable for repositioning when the Grid has to be<br />

removed.<br />

Due to the need for other research subjects such as New World Monkeys, Felines, Rodents and other<br />

small animals we are manufacturing a smaller line of Chambers. These Chambers are available in Stainless<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com


CRIST INSTRUMENT COMPANY, INC.<br />

111 W. First Street<br />

Hagerstown, Maryland 21740 USA<br />

Telephone 1-301/393-8615 Fax 1-301/393-8618<br />

E-mail neurotoys@msn.com<br />

Steel and CILUX. The feline Chamber is identical in inner and outer diameters and has the same pin<br />

arrangement as the standard primate chambers. Because the skull of a feline is more square with a sharper<br />

radius as you move outward to the edge of the skull we have found it necessary to modify the angle by<br />

curving the chamber base rather than a straight angle cut. When selecting the Stainless Steel material ask for<br />

part number 6-ISC-S-xx. The CILUX model part number is 6-ISC-J-xx where “xx” indicates the degree of<br />

angle you require. The New World animals require a smaller chamber. The sizes of these Chambers (6-<br />

ISM-S-xx and 6-ISM-J-xx) are as follows: the i.d. is .5118” (13 mm) and the o.d. is .630” (16 mm). The<br />

overall height of the “0” degree Chamber is ½” (12.65 mm). It is turned down at the top to a diameter of .59”<br />

(14.986 mm) and also has a groove for attaching an adapter if one is needed. The locating pin is provided on<br />

one side for positioning repeatability. It is available in angles from “0” to 60 degrees.<br />

The smaller Chambers function very much the same way as our larger Chambers for primates.<br />

Placement on the skull in a given location is achieved by varying the angle of the base of the Cylinder from<br />

“0” degrees to 45 degrees. This angle is used to correct the curvatures of the surface of the skull falling away<br />

as you move to the outer fringe. With the Chamber held in place by the Alignment Tools you can fill the<br />

voids that occur between the bottom edge of the chamber and the skull with the acrylic. This will maintain<br />

when properly done a perfectly vertical penetration resulting in the accurate planar mapping of the selected<br />

area.<br />

Any of these units need to be aligned and attached during surgery using The Grid Alignment Tools,<br />

set number 6-YSA-SET-1A. This is done to assure that all elements are located in the correct grid position of<br />

the horizontal plane and are absolutely vertical unless otherwise desired. Any angles or variations in<br />

positioning must be recorded at this time to assure an accurate map.<br />

The Chambers, Grids and Adapter mentioned here are the recommended standard styles and sizes that<br />

we normally stock. We also supply Chambers in a variety of shapes and sizes with matching Adapters or<br />

devices to use the Narishige type MO 95 microdrive.<br />

Placement on the skull in a given location is achieved by varying the angle of the base of the cylinder<br />

from “0” degrees to 45 degrees. This will maintain if properly done a perfectly vertical penetration resulting<br />

in the accurate planar mapping of the selected area.<br />

111West First Street, Hagerstown MD 21740 USA<br />

Telephone: 301-393-8615 · FAX: 301-393-8618<br />

E-mail: Pat@cristinstrument.com · Website: http://www.cristinstrument.com<br />

PDF created with pdfFactory trial version www.pdffactory.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!