25.11.2014 Views

Security Center 5.1 GA Release Notes - Genetec

Security Center 5.1 GA Release Notes - Genetec

Security Center 5.1 GA Release Notes - Genetec

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Security</strong> <strong>Center</strong><br />

<strong>Release</strong> <strong>Notes</strong><br />

<strong>5.1</strong> <strong>GA</strong><br />

Click here for the most recent version of this document.


Copyright notice<br />

© 2011, 2012 <strong>Genetec</strong> Inc. All rights reserved.<br />

<strong>Genetec</strong> Inc. distributes this document with software that includes an end-user license agreement and is<br />

furnished under license and may be used only in accordance with the terms of the license agreement. The<br />

contents of this document are protected under copyright law.<br />

The contents of this guide are furnished for informational use only and are subject to change without notice.<br />

<strong>Genetec</strong> Inc. assumes no responsibility or liability for any errors or inaccuracies that may appear in the<br />

informational content contained in this guide.<br />

This publication may not be copied, modified, or reproduced in any form or for any purpose, nor can any<br />

derivative works be created therefrom without <strong>Genetec</strong> Inc.’s prior written consent.<br />

<strong>Genetec</strong> Inc. reserves the right to revise and improve its products as it sees fit. This document describes the state<br />

of a product at the time of document’s last revision, and may not reflect the product at all times in the future.<br />

In no event shall <strong>Genetec</strong> Inc. be liable to any person or entity with respect to any loss or damage that is<br />

incidental to or consequential upon the instructions found in this document or the computer software and<br />

hardware products described herein. The use of this document is subject to the disclaimer of liability found in<br />

the end–user license agreement.<br />

"<strong>Genetec</strong>", "Omnicast", "Synergis", "Synergis Master Controller", "AutoVu", "Federation", the <strong>Genetec</strong> stylized<br />

"G" and the Omnicast, Synergis and AutoVu logos are trademarks of <strong>Genetec</strong> Inc., either registered or pending<br />

registration in several jurisdictions.<br />

"<strong>Security</strong> <strong>Center</strong>", "<strong>Security</strong> <strong>Center</strong> Mobile", "Plan Manager", and the <strong>Security</strong> <strong>Center</strong> logo are trademarks of<br />

<strong>Genetec</strong> Inc.<br />

Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or<br />

vendors of the respective products.<br />

All specifications are subject to change without notice.<br />

Document information<br />

Document title: <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> <strong>5.1</strong> <strong>GA</strong><br />

Document number: EN.500.001-V<strong>5.1</strong>.B(6)<br />

Document update date: February 23, 2012<br />

You can send your comments, corrections, and suggestions about this guide to documentation@genetec.com.<br />

ii<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Product documentation<br />

<strong>Security</strong> <strong>Center</strong> includes the following documentation:<br />

• <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong>. Describes the release in detail, including new features, resolved issues,<br />

known issues, and limitations.<br />

• <strong>Security</strong> <strong>Center</strong> Installation and Upgrade Guide. Describes the prerequisites for installing <strong>Security</strong> <strong>Center</strong>,<br />

and provides instructions for installing and upgrading <strong>Security</strong> <strong>Center</strong> on your system.<br />

• <strong>Security</strong> <strong>Center</strong> Administrator Guide. Provides all the instructions and conceptual information you’ll need to<br />

set up, configure, and administer your <strong>Security</strong> <strong>Center</strong> system.<br />

• Getting Started with <strong>Security</strong> Desk. A task-oriented introduction to <strong>Security</strong> Desk that uses real-world<br />

scenarios (viewing a camera, searching/exporting video, and managing alarms) to show new users how to use<br />

the basic product features.<br />

• <strong>Genetec</strong> <strong>Security</strong> Desk User Guide. Provides the instructions and conceptual information you need to get<br />

started with <strong>Security</strong> Desk, to monitor and generate reports for AutoVu LPR, Omnicast video surveillance, and<br />

Synergis access control systems.<br />

• <strong>Security</strong> <strong>Center</strong> Video Unit Configuration Guide. Provides the pre-configuration instructions for integrating<br />

video units into <strong>Security</strong> <strong>Center</strong>, and any configuration steps required for some video unit features to work.<br />

• <strong>Security</strong> <strong>Center</strong> Portable Archive Player User Guide. Explains how to use the Portable Archive Player to view<br />

exported video files.<br />

• AutoVu Patroller <strong>Release</strong> <strong>Notes</strong>. Describes the AutoVu Patroller release in detail, including new features,<br />

resolved issues, known issues, and limitations.<br />

• AutoVu Hardware <strong>Release</strong> <strong>Notes</strong>. Describes the AutoVu Hardware for this release in detail, including new<br />

features, resolved issues, known issues, and limitations.<br />

• AutoVu Handbook. Provides AutoVu installers and administrators with a single source of information about<br />

installing and configuring AutoVu hardware and software.<br />

• AutoVu Patroller User Guides. Quick reference guides to using Patroller, AutoVu’s mobile LPR solution. There<br />

is a separate user guide for each Patroller installation type (Law Enforcement, City Parking Enforcement, City<br />

Parking Enforcement with Wheel Imaging, University Parking Enforcement, and Mobile License Plate<br />

Inventory).<br />

• AutoVu Connecting the Sharp Camera. Explains how to power up and connect your Sharp. A printed version<br />

is provided in the Sharp box.<br />

• AutoVu Connecting the SharpX Camera. Explains how to power up and connect your SharpX. A printed<br />

version is provided in the SharpX box.<br />

• Plugin User Guides. Introduces you to the plugin features and describes what’s new in the current release. It<br />

also explains how to install and configure the plugin in <strong>Security</strong> <strong>Center</strong>, and how to use it in <strong>Security</strong> Desk.<br />

Where can I find the product documentation?<br />

• Product DVD. The documentation is available on the product DVD in the Documentation folder. <strong>Release</strong> notes<br />

and installation guides include a direct link to the latest version of the document.<br />

• <strong>Genetec</strong> Technical Assistance Portal (GTAP). The latest version of the documentation is available from GTAP.<br />

Note, you’ll need a username and password to log on to GTAP.<br />

• Online help. <strong>Security</strong> <strong>Center</strong> client applications include online help, which explain how the product works<br />

and provide instructions on how to use the product features. Patroller and the Sharp portal also include<br />

context-sensitive help for each screen. To access the online help, click Help, press F1, or tap<br />

the ? (question mark) in the different client applications.<br />

iii<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Technical support<br />

<strong>Genetec</strong> Technical Assistance <strong>Center</strong> (GTAC) is committed to providing its worldwide clientele with the best<br />

technical support services available. As a <strong>Genetec</strong> customer, you have access to the <strong>Genetec</strong> Technical Assistance<br />

Portal (GTAP), where you can find information and search for answers to your product questions.<br />

• <strong>Genetec</strong> Technical Assistance Portal (GTAP). GTAP is a support website that provides in-depth support information,<br />

such as FAQs, knowledge base articles, user guides, supported device lists, training videos, product<br />

tools, and much more.<br />

Prior to contacting GTAC or opening a support case, it is important to look at this website for potential fixes,<br />

workarounds, or known issues. You can log in to GTAP or sign up at https://gtap.genetec.com.<br />

• <strong>Genetec</strong> Technical Assistance <strong>Center</strong> (GTAC). If you cannot find your answers on GTAP, you can open a support<br />

case online at https://gtap.genetec.com. For GTAC's contact information in your region see the Contact<br />

page at https://gtap.genetec.com.<br />

NOTE Before contacting GTAC, please have your System ID (available from the About button in your client<br />

application) and your SMA contract number (if applicable) ready.<br />

• Licensing.<br />

• For license activations or resets, please contact GTAC at https://gtap.genetec.com.<br />

• For issues with license content or part numbers, or concerns about an order, please contact <strong>Genetec</strong> Customer<br />

Service at customerservice@genetec.com, or call 1-866-684-8006 (option #3).<br />

• If you require a demo license or have questions regarding pricing, please contact <strong>Genetec</strong> Sales at<br />

sales@genetec.com, or call 1-866-684-8006 (option #2).<br />

Additional resources<br />

If you require additional resources other than the <strong>Genetec</strong> Technical Assistance <strong>Center</strong>, the following is available<br />

to you:<br />

• GTAP Forum. The Forum is an easy to use message board that allows clients and <strong>Genetec</strong> staff to communicate<br />

with each other and discuss a variety of topics, ranging from technical questions to technology tips. You<br />

can log in or sign up at https://gtapforum.genetec.com.<br />

• Technical training. In a professional classroom environment or from the convenience of your own office, our<br />

qualified trainers can guide you through system design, installation, operation, and troubleshooting. Technical<br />

training services are offered for all products and for customers with a varied level of technical experience,<br />

and can be customized to meet your specific needs and objectives. For more information, go to http://<br />

www.genetec.com/English/Support/Training.<br />

iv<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Contents<br />

Product documentation . . . . . . . . . . . . . . . . . . iii<br />

Technical support . . . . . . . . . . . . . . . . . . . iv<br />

<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong><br />

What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong>? . . . . . . . . . . . . . 2<br />

General product enhancements. . . . . . . . . . . . . . . 2<br />

Config Tool enhancements . . . . . . . . . . . . . . . . 4<br />

<strong>Security</strong> Desk enhancements . . . . . . . . . . . . . . . 4<br />

Omnicast video surveillance enhancements. . . . . . . . . . . . 5<br />

Synergis access control enhancements . . . . . . . . . . . . . 6<br />

AutoVu LPR enhancements . . . . . . . . . . . . . . . 7<br />

Supported hardware . . . . . . . . . . . . . . . . . . 9<br />

About hardware certification . . . . . . . . . . . . . . . 9<br />

New supported video units in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> . . . . . . . . . 9<br />

New supported video units in <strong>Security</strong> <strong>Center</strong> 5.0 SR1 Hardware Integration Package 1 . 13<br />

Supported Bosch intrusion detection units . . . . . . . . . . . . 14<br />

Supported Honeywell Galaxy intrusion detection devices . . . . . . . . 15<br />

Supported HID units . . . . . . . . . . . . . . . . . 16<br />

HID unit compatibility . . . . . . . . . . . . . . . . 16<br />

HID unit known issues . . . . . . . . . . . . . . . . 17<br />

HID unit limitations . . . . . . . . . . . . . . . . 17<br />

Where to find more information about supported hardware . . . . . . . 18<br />

Resolved issues . . . . . . . . . . . . . . . . . . . 19<br />

Resolved software issues . . . . . . . . . . . . . . . . 19<br />

Resolved hardware issues . . . . . . . . . . . . . . . . 20<br />

Known issues . . . . . . . . . . . . . . . . . . . . 22<br />

Limitations . . . . . . . . . . . . . . . . . . . . 27<br />

System requirements . . . . . . . . . . . . . . . . . . 31<br />

Supported languages . . . . . . . . . . . . . . . . . . 31<br />

Supported upgrades . . . . . . . . . . . . . . . . . . 32<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version<br />

EN.500.001-V<strong>5.1</strong>.B(6)<br />

v


Supported upgrades from Synergis 2.1. . . . . . . . . . . . . . 32<br />

Supported Omnicast migration paths . . . . . . . . . . . . . . 32<br />

Supported AutoVu migration paths . . . . . . . . . . . . . . 33<br />

Supported federations . . . . . . . . . . . . . . . . . . 33<br />

Compatibility . . . . . . . . . . . . . . . . . . . . 34<br />

<strong>Security</strong> <strong>Center</strong> backward compatibility . . . . . . . . . . . . . 34<br />

Backward compatibility with <strong>Security</strong> <strong>Center</strong> 5.0 roles . . . . . . . . 34<br />

Backward compatibility with <strong>Security</strong> Desk 5.0 tasks . . . . . . . . . 35<br />

<strong>Security</strong> <strong>Center</strong> Media Router compatibility . . . . . . . . . . . . 38<br />

Omnicast compatibility . . . . . . . . . . . . . . . . . 39<br />

<strong>Security</strong> <strong>Center</strong> and Patroller compatibility . . . . . . . . . . . . 39<br />

Sharp compatibility . . . . . . . . . . . . . . . . . . 39<br />

About the documentation in this release . . . . . . . . . . . . . 40<br />

Documents added . . . . . . . . . . . . . . . . . . 40<br />

Documents replaced . . . . . . . . . . . . . . . . . 40<br />

Supported documentation languages . . . . . . . . . . . . . 41<br />

vi<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version<br />

EN.500.001-V<strong>5.1</strong>.B(6)


<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong><br />

<strong>Security</strong> <strong>Center</strong> is the unified security platform that seamlessly blends <strong>Genetec</strong>'s IP security<br />

and safety systems within a single innovative solution. The systems unified under <strong>Security</strong><br />

<strong>Center</strong> include <strong>Genetec</strong>'s Omnicast IP video surveillance system, Synergis IP access control<br />

system, and AutoVu IP license plate recognition (LPR) system.<br />

<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> is a general availability release that includes many new features and<br />

enhancements. This document describes the release in detail, and provides late-breaking or<br />

other information that supplements the <strong>Genetec</strong> <strong>Security</strong> <strong>Center</strong> documentation.<br />

This document includes the following topics:<br />

• "What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong>?" on page 2<br />

• "Supported hardware" on page 9<br />

• "Resolved issues" on page 19<br />

• "Known issues" on page 22<br />

• "Limitations" on page 27<br />

• "System requirements" on page 31<br />

• "Supported languages" on page 31<br />

• "Supported upgrades" on page 32<br />

• "Supported Omnicast migration paths" on page 32<br />

• "Supported AutoVu migration paths" on page 33<br />

• "Supported federations" on page 33<br />

• "Compatibility" on page 34<br />

• "About the documentation in this release" on page 40<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 1<br />

EN.500.001-V<strong>5.1</strong>.B(6)


What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong>?<br />

What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong>?<br />

<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> introduces the following new features and enhancements.<br />

This section includes the following topics:<br />

• "General product enhancements" on page 2<br />

• "Config Tool enhancements" on page 4<br />

• "<strong>Security</strong> Desk enhancements" on page 4<br />

• "Omnicast video surveillance enhancements" on page 5<br />

• "Synergis access control enhancements" on page 6<br />

• "AutoVu LPR enhancements" on page 7<br />

General product enhancements<br />

• Installer enhancements. Hotfixes for <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> and later can now be<br />

installed using a hotfix installer. Also, the <strong>Security</strong> <strong>Center</strong> installer now creates the necessary<br />

firewall rules for its applications.<br />

• Forward and backward compatibility. <strong>Security</strong> <strong>Center</strong> Directory can connect to different<br />

versions of <strong>Security</strong> <strong>Center</strong> client and server applications, making it easier to<br />

upgrade large systems. A difference of up to two minor versions forwards and two<br />

minor versions backwards is supported.<br />

• High Availability Directory. Includes the following features:<br />

• Directory failover. If a Directory server fails, a standby server can automatically<br />

replace it.<br />

• Load balancing. The Directory can be spread across multiple servers to share the<br />

workload.<br />

• View live and playback video even if you lose connection to the Directory.<br />

• Active Directory enhancements.<br />

• Support for multiple domains. <strong>Security</strong> <strong>Center</strong> can now connect to more than one<br />

Active Directory domain (designed to support up to 10).<br />

• Custom Field synchronization. You can now synchronize attributes from the Active<br />

Directory to custom fields in <strong>Security</strong> <strong>Center</strong>. This is supported for users, cardholders,<br />

user groups and cardholder groups.<br />

• Health monitoring. You can now monitor the health of your system using the Health<br />

Monitoring role. It includes the following features:<br />

• Monitors the health of the entire system.<br />

• Logs health events in the Windows Event Log that have been triggered by <strong>Security</strong><br />

<strong>Center</strong> services, roles, agents, units, and client applications.<br />

• Provides real time alerts as well as detailed historical reporting.<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 2<br />

EN.500.001-V<strong>5.1</strong>.B(6)


What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong>?<br />

• Calculates statistics within specified time frame (hours, days, months).<br />

• Calculates availability for clients, server, and video/access/LPR units.<br />

• Receives events that are sent directly from various roles and entities.<br />

This features also allows you to view health events in the Health History report, and<br />

retrieve health events via the SDK.<br />

• Move units between manager roles. If you are using multiple manager roles spread<br />

across your network, you can now easily move units between those managers with the<br />

Move Unit tool.<br />

• AutoVu example. If you have a dedicated LPR Manager for each police station precinct<br />

in a city, and a particular patroller unit is transferred to another precinct, you<br />

can use the Move Unit tool to easily move the Patroller unit to the new LPR Manager<br />

without losing data.<br />

• Synergis example. After an office expansion you may want one Access Manager to<br />

control all access control units (door controllers) on one floor and another Access<br />

Manager to control all units on a different floor. You can use the Move Unit tool to<br />

move a door controller to the new Access Manager without losing data.<br />

• Plan Manager. Plan Manager is an advanced map-based interface for <strong>Security</strong> <strong>Center</strong>.<br />

It allows you to create interactive environments from maps or floor plans for easier<br />

monitoring and navigation. Live video, doors, alarms, inputs/outputs, PTZ motors, and<br />

more can be monitored and controlled from the Plan Manager interface in <strong>Security</strong><br />

Desk.<br />

• RF Code Asset Management plugin. <strong>Security</strong> <strong>Center</strong> now supports the RF Code Asset<br />

Management plugin, which enables you to do the following:<br />

• Synchronize RF Code assets with <strong>Security</strong> <strong>Center</strong> assets (a new entity).<br />

• Monitor asset-related events and activities live.<br />

• Synchronize RF Code alerts with <strong>Security</strong> <strong>Center</strong> alarms automatically.<br />

• Acknowledge alarms in <strong>Security</strong> <strong>Center</strong>, which will clear alerts in the RF Code solution.<br />

• View video tied to asset-related activity and alerts.<br />

• Perform real-time tracking of asset locations using the Asset Management Inventory<br />

reporting task.<br />

• View events associated to tracked assets using the Asset Activity reporting task.<br />

• Honeywell Galaxy panel integration. <strong>Security</strong> <strong>Center</strong> now supports the Honeywell<br />

Galaxy control panels, which enables you to do the following:<br />

• Map inputs and devices connected to the alarm panel to intrusion detection areas in<br />

<strong>Security</strong> <strong>Center</strong>.<br />

• Monitor the connection between the <strong>Security</strong> <strong>Center</strong> Server and the alarm panel<br />

using the heartbeat feature.<br />

• Create event-to-actions for events that are sent from the alarm panel.<br />

• Create custom events, which can be monitored in <strong>Security</strong> Desk.<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 3<br />

EN.500.001-V<strong>5.1</strong>.B(6)


What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong>?<br />

• Monitor intrusion detection area state changes in real time in <strong>Security</strong> Desk<br />

• Receive events and alarms from the alarm panel, and monitor them in <strong>Security</strong><br />

Desk.<br />

• Arm and disarm the intrusion detection areas defined on your intrusion panels in<br />

<strong>Security</strong> Desk.<br />

• Receive live reports on input state changes in <strong>Security</strong> Desk.<br />

• Create reports on events received from the alarm panel.<br />

• Trigger intrusion alarms on intrusion detection areas or intrusion detection units in<br />

<strong>Security</strong> Desk.<br />

• Generate detailed activity reports on intrusion detection areas or intrusion detection<br />

units.<br />

• Language support. Hebrew, Hungarian, Polish, Thai, and Traditional Chinese are now<br />

supported in <strong>Security</strong> <strong>Center</strong>.<br />

Config Tool enhancements<br />

• Task-based interface. To improve usability and ensure consistency with <strong>Security</strong> Desk,<br />

the Config Tool is now task-based. It’s redesigned home page lists the available tasks,<br />

favorites, and more.<br />

• New tasks available. The following tasks are now available in the Config Tool: Role<br />

View, Network View, Logical View, System, <strong>Security</strong>, Access Control, and LPR.<br />

• <strong>Security</strong> Desk tasks are now available in Config Tool. Cardholder Management, Credential<br />

Management, and all Maintenance related tasks.<br />

• New reports available. Health Statistics, and Health History reports.<br />

<strong>Security</strong> Desk enhancements<br />

• New Home page. The <strong>Security</strong> Desk’s redesigned home page lists the available tasks<br />

and recently used tasks, and allows you to access your saved private and public tasks,<br />

the Tools menu, the About menu, and the Options dialog box.<br />

• Workspace layout enhancements. The dashboard is now located on the right hand<br />

side of the interface.Video timelines have been moved from the playback widget, to<br />

each display tile.<br />

• New reports available. Health statistics, Asset management and Forensic search<br />

reports.<br />

• Health warnings in notification tray. Health warnings now appear in the notification<br />

tray. If you double-click the icon, it opens the Health History report.<br />

• New custom field filters for reports. There is now a custom fields filter in the Cardholder<br />

configuration and Credential configuration reports.<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 4<br />

EN.500.001-V<strong>5.1</strong>.B(6)


What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong>?<br />

• Digital PTZ zoom support. In-tile digital zoom is now supported.<br />

• Event priority enhancements. Event priorities have been replaced by background colors<br />

that are visible the event list and display tiles. To easily distinguish critical events<br />

from less important events, and ensure that critical events stand out, you can assign different<br />

colors to different events.<br />

• Out of process media decoding. The media decoding process now can be executed<br />

outside of the application process, which increases the overall performance of the client<br />

applications.<br />

• Quick archives. When viewing live video, you can quickly play back recordings from<br />

the same camera by browsing date/time and thumbnail previews.<br />

• Two ways to send tasks. There are now two ways to send a task to other <strong>Security</strong> Desk<br />

applications:<br />

• Previous method: Right-click on a task tab to send the task to a user or monitor. A<br />

pop up message appears on the remote workstation asking if the recipient accepts<br />

the sent task.<br />

• New method: Send task is a system action which can be linked to an event (like<br />

alarm triggered), or executed manually through a hot action.<br />

This new method does not produce a dialog asking if the sent task is accepted,<br />

which is useful for video walls. This method also includes the opposite command,<br />

Clear tasks, which removes tasks from a remote workstation.<br />

• Snapshot manager. The Snapshot manager performs some of the tasks that used to be<br />

available from the camera widget, such as delete, rename, or print snapshots, or send<br />

the snapshots by email. The camera widget in <strong>Security</strong> Desk now only has the Save<br />

snapshot button.<br />

Omnicast video surveillance enhancements<br />

• Uninterrupted video streaming. Video streams displayed in the <strong>Security</strong> Desk remain<br />

available even if the Directory or other critical roles become unavailable.<br />

• Video trickling. Video stored on edge devices can be transferred on a schedule, on<br />

demand or by an event, to the <strong>Security</strong> <strong>Center</strong> Archiver.<br />

• Auxiliary Archiver. Cameras can be recorded in a remote location, at different qualities,<br />

and on different schedules than the main Archiver.<br />

• Forensic search task. Ability to perform forensic (video analytic) search using Bosch<br />

video units with edge recording capabilities and IVA enabled.<br />

• AAC audio codec (Axis). Advanced Audio Coding (AAC) audio type, which provides<br />

better audio quality, is now supported on select video units such as Axis.<br />

• Support for watermarking with Bosch VRM. Watermarking verification is now possible<br />

for video recorded by the Bosch VRM using an external tool.<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 5<br />

EN.500.001-V<strong>5.1</strong>.B(6)


What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong>?<br />

• Support for video file protection with Bosch VRM. Video files recorded on a Bosch<br />

VRM can be protected for an indefinite protection period in <strong>Security</strong> Desk.<br />

• Support for ACTi MJPEG and H.264 in full extension. ACTi MJPEG and H.264<br />

video units now benefit from the full ACTi extension capabilities.<br />

• Bosch maximum bit rate. A maximum bit rate value can now be applied in the video<br />

quality configuration page for Bosch video units.<br />

• Axis - disable Bonjour discovery option. The default Bonjour network discovery protocol<br />

can now be disabled if desired for Axis video units.<br />

• Archive viewing limitation now granular to the minute. Users can be limited from<br />

viewing video archives based on a time value of days/hours/minutes. For example, an<br />

operator can be limited to playback recordings created within the last 2 days, 12 hours<br />

and 30 minutes. Any recording older this value cannot be played back by the operator.<br />

• Motion detection configuration utility. The level of sensitivity for a camera’s motion<br />

detection configuration can now be set using an Auto calibrate utility.<br />

• Support for Interlogix . Interlogix MPEG-4 units and DVMRe/Storesafe units are now<br />

supported in <strong>Security</strong> <strong>Center</strong>.<br />

• Support for Sentry 360. Sentry 360 H.264 units are now supported in <strong>Security</strong> <strong>Center</strong>.<br />

Use <strong>Security</strong> <strong>Center</strong> features to dewarp the 360 degree view.<br />

Synergis access control enhancements<br />

IMPORTANT Synergis Web Client is no longer available as of <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong>. It will<br />

be replaced by <strong>Security</strong> <strong>Center</strong> Web Client in early 2012. If you are using the Synergis Web<br />

Client, you should wait to upgrade until Mobile 3.0 is released.<br />

• Global Cardholder Management enhancements. The Cardholder Management task<br />

now allows you to do the following:<br />

• Cardholders, cardholder groups, credentials, custom fields, and badge templates can<br />

be synchronized between sites from a central location.<br />

• Changes to a remote site can be synchronized with the central site, and with other<br />

remote sites.<br />

• Cardholders added centrally can be synchronized to remote sites.<br />

• One card can be used for all sites within a multi-campus, geographically dispersed<br />

organization.<br />

• Synchronize Active Directory custom fields for cardholders. Active Directory custom<br />

fields can be synchronized to cardholder custom fields. This avoids the need to<br />

manage custom fields separately from Active Directory, and extends the synchronization<br />

capabilities of the feature.<br />

• HID unit synchronization enhancements. This feature includes the following:<br />

• Enhanced synchronization between units and the Access Manager.<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 6<br />

EN.500.001-V<strong>5.1</strong>.B(6)


What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong>?<br />

• A unit that gets disconnected from the network or from the Access Manager will no<br />

longer force a full synchronization.<br />

• PIN visibility. You can now view the PIN code digits in Config Tool and <strong>Security</strong> Desk.<br />

The Show PIN settings is available in the Cardholder management task.<br />

AutoVu LPR enhancements<br />

IMPORTANT All AutoVu LPR feature enhancements in this release are only for Law<br />

Enforcement. Only upgrade to <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> if you are using the Patroller Law<br />

Enforcement installation type.<br />

• Patroller and Sharp live updates. You can use <strong>Security</strong> <strong>Center</strong> Config Tool to update<br />

services and send hotfixes to Patroller units and Sharp cameras, as well as send new<br />

sound files to be used for Patroller hit alerts. Both fixed and mobile Sharp cameras can<br />

be updated, with mobile Sharps receiving the updates through Patroller. You can<br />

update individual Patroller and Sharp units or update all units and services simultaneously.<br />

• Health monitoring available for LPR. You can now use <strong>Security</strong> <strong>Center</strong>’s health monitoring<br />

feature to monitor LPR-related information. This allows you to detect health<br />

issues early enough to avoid potential issues in the future. Health monitoring also provides<br />

you with information to help identify the cause of various health problems so you<br />

can prevent them from occurring again.<br />

• Server-configured Patroller options. You can configure several options for individual<br />

Patroller units directly from <strong>Security</strong> <strong>Center</strong> Config Tool. You can also use the Copy<br />

configuration tool to easily copy these settings to any or all of your other Patroller units:<br />

• Sound management settings. Configure Patroller to play a sound when reading a<br />

plate and/or generating a hit, and choose whether sounds should be played even<br />

when Patroller is minimized.<br />

• Acknowledgment buffer settings. Specify a buffer restriction that limits how many<br />

hits can remain unacknowledged (not accepted or rejected) before Patroller starts<br />

automatically rejecting all subsequent hits. You can also choose (by priority) which<br />

hotlists should comply with this restriction.<br />

• Hotlist hit delay settings. Specify a hit delay that tells Patroller to disregard multiple<br />

hits on the same plate for the duration of the delay. For example, if you set a delay of<br />

10 minutes, no matter how many times Patroller reads the same plate during those<br />

10 minutes, it will generate only one hit (assuming the plate is on a hotlist).<br />

• AutoVu Patroller enhancements. For AutoVu Patroller enhancements, see the AutoVu<br />

Patroller <strong>Release</strong> <strong>Notes</strong>. The latest version of this document is available at: http://<br />

downloads.genetec.com/<strong>Security</strong><strong>Center</strong>/<strong>5.1</strong>/<strong>GA</strong>/AutoVu/EN.AutoVu%20Patroller%20<strong>Release</strong>%20<strong>Notes</strong>%20<strong>5.1</strong>%20<strong>GA</strong>.pdf.<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 7<br />

EN.500.001-V<strong>5.1</strong>.B(6)


What’s new in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong>?<br />

• AutoVu hardware enhancements. For AutoVu hardware enhancements, see the AutoVu<br />

Hardware <strong>Release</strong> <strong>Notes</strong>. The latest version of this document is available at: http://<br />

downloads.genetec.com/<strong>Security</strong><strong>Center</strong>/<strong>5.1</strong>/<strong>GA</strong>/AutoVu/EN.AutoVu%20Hardware%20<strong>Release</strong>%20<strong>Notes</strong>%20<strong>5.1</strong>%20<strong>GA</strong>.pdf.<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 8<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Supported hardware<br />

Supported hardware<br />

This section includes the following topics:<br />

• "About hardware certification" on page 9<br />

• "New supported video units in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong>" on page 9<br />

• "New supported video units in <strong>Security</strong> <strong>Center</strong> 5.0 SR1 Hardware Integration Package<br />

1" on page 13<br />

• "Supported Bosch intrusion detection units" on page 14<br />

• "Supported Honeywell Galaxy intrusion detection devices" on page 15<br />

• "Supported HID units" on page 16<br />

• "Where to find more information about supported hardware" on page 18<br />

About hardware certification<br />

There are three levels of integration hardware certification:<br />

• Certified. The Omnicast integration with this device model has been tested and validated<br />

by <strong>Genetec</strong>.<br />

• Supported by design. The device model shares the same API as an existing certified<br />

device unit, but has not been tested or validated by <strong>Genetec</strong>.<br />

• Tested by partner. The Omnicast integration with this camera model has been tested<br />

by the partner and has not been certified by <strong>Genetec</strong>.<br />

New supported video units in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong><br />

The following video units are now supported in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong>. For each unit<br />

model, the Archiver extension and certification level is listed.<br />

Manufacturer Unit Models Extension Certification<br />

ACTi • TCD-2100<br />

• TCM-1511<br />

• TCM-3401<br />

• TCM-3411<br />

• TCM-3511<br />

• TCM-4201<br />

• TCM-5601<br />

• TCM-5611<br />

• TCM-7411<br />

• TCM-7811<br />

ACTi<br />

Supported by design<br />

• TCD-2500 ACTi Certified<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 9<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Supported hardware<br />

Manufacturer Unit Models Extension Certification<br />

Arecont • D4F-AV3115<br />

• D4F-AV5115<br />

• D4S-AV3115<br />

• D4S-AV5115<br />

Axis • M3114-VE<br />

• M5013<br />

• M5014<br />

• P5512<br />

• P5512-E<br />

• P5522<br />

• P5522-E<br />

• Q6032<br />

• Q6035<br />

• Q6035-E<br />

• Q7414<br />

Arecont<br />

Axis<br />

Supported by design<br />

Certified<br />

Bosch • Divar 700 Generic Plus Certified<br />

Canon • VB-M40<br />

• VB-M600D<br />

• VB-M600VE<br />

• VB-M700F<br />

CBC • ZN-C1<br />

• ZN-C1M<br />

• ZN-C2M<br />

• ZN-D1A<br />

• ZN-D1MAP<br />

• ZN-D2MAP<br />

• ZN-DT1A<br />

• ZN-DT1MA<br />

• ZN-DT2MA<br />

CISCO • CIVS-IPC-2421<br />

• CIVS-IPC-2521V<br />

Generic Plus (ONVIF)<br />

<strong>Genetec</strong> Protocol<br />

Generic<br />

Tested by partner<br />

Tested by Partner<br />

Certified<br />

• CIVS-IPC-5010 Pelco Certified<br />

• CIVS-IPC-2621V Generic Supported by design<br />

• CIVS-IPC-2930<br />

• CIVS-IPC-5011<br />

Pelco<br />

Supported by design<br />

GSG<br />

International<br />

• KLIS IPCAM-1M-SD<br />

• KLIS IPCAM-2M-SD-H<br />

• KLIS IPCAM-IR1<br />

• KLIS IPCAM-1M-SD<br />

<strong>Genetec</strong> Protocol<br />

Tested by partner<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 10<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Supported hardware<br />

Manufacturer Unit Models Extension Certification<br />

Interlogix • DVMRe Triplex 10CT<br />

• DVMRe Triplex 10CTII<br />

• DVMRe Triplex 16CT<br />

• DVMRe Triplex 16CTII<br />

• StoreSafe Pro<br />

• StoreSafe Pro II<br />

• Legend IP<br />

• SymDec1<br />

• SymDec4<br />

• SymDec16<br />

• SymNet<br />

• SymSafe Pro 4<br />

• SymSafe Pro 8<br />

• SymSafe Pro 16<br />

• SymSafe 4<br />

• SymSafe 8<br />

• SymSafe 16<br />

• SymVeo<br />

IQinVision • IQ832N<br />

• IQA32N<br />

• IQA33N<br />

• IQA35N<br />

• IQD30S<br />

• IQD31S<br />

• IQD32S<br />

• IQM32N<br />

• IQ832S<br />

• IQA30N<br />

• IQA31N<br />

• IQM30N<br />

• IQM30S<br />

• IQM31N<br />

• IQM31S<br />

• IQM32S<br />

GE DVMRe<br />

GE MPEG-4<br />

IQEye<br />

IQEye<br />

Certified<br />

Certified<br />

Certified<br />

Supported by design<br />

Moxa • VPort461 Generic Plus (ONVIF) Tested by partner<br />

Samsung<br />

(ONVIF)<br />

• SNO-5080R Generic Plus (ONVIF) Supported by design<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 11<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Supported hardware<br />

Manufacturer Unit Models Extension Certification<br />

Sentry 360 • FS-IP5000<br />

• FS-IP10K<br />

• FS-IP3000<br />

• IS-IP300<br />

• IS-IP500<br />

• IS-IP10K<br />

Sony • SNC-EP520<br />

• SNC-EP580<br />

• SNC-ER520<br />

• SNC-ER580<br />

Visiowave • EVOLUTION HD<br />

• DISCOVERY 300<br />

Sentry 360<br />

Sentry 360<br />

Sony<br />

Generic Plus<br />

Certified<br />

Supported by design<br />

Certified<br />

Certified<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 12<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Supported hardware<br />

New supported video units in <strong>Security</strong> <strong>Center</strong> 5.0 SR1 Hardware<br />

Integration Package 1<br />

<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> also includes the following video units that were added in <strong>Security</strong><br />

<strong>Center</strong> 5.0 SR1 Hardware Integration Package 1.<br />

NOTE Some of the certification statuses and extension types of these units may have<br />

changed since the last release. For details, see the Supported Devices list on <strong>Genetec</strong>'s<br />

Technical Assistance Portal (GTAP), at https://gtap.genetec.com.<br />

Manufacturer Unit Models Extension Certification<br />

Arecont • AV115<br />

• AV5155<br />

• AV3125<br />

• AV5125<br />

CNB • ISS2765<br />

• ISS2965<br />

• IDC4050VR<br />

Arecont<br />

<strong>Genetec</strong><br />

Certified<br />

Tested by partner<br />

Epiphan • V<strong>GA</strong> Broadcaster Lite Generic Supported by design<br />

HikVision • DS-2CD793NF-E<br />

• DS-2CD7153-E<br />

• DS-2CD853F-E<br />

• DS-2CD876BF<br />

• DS-2CD883F-E<br />

<strong>Genetec</strong><br />

Certified<br />

Mavix • MediaRacer 152 Generic Supported by design<br />

Optelecom-NKF • HSD620<br />

• HSD622<br />

• HSD624<br />

• HSD626<br />

• HSD628<br />

• MSD620<br />

• MSD622<br />

Panasonic • WV-SW352<br />

• DG-SW355<br />

• DG-SP304<br />

• WV-SC384<br />

• BB-SC384<br />

Optelecom-NKF<br />

Panasonic<br />

Tested by partner<br />

Certified<br />

Pelco Sarix • NET5402T Pelco Certified<br />

• NET5401T<br />

• NET5404T<br />

Pelco<br />

Supported by design<br />

Pixel Velocity • Video Commander 2.7 <strong>Genetec</strong> Tested by partner<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 13<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Supported hardware<br />

Manufacturer Unit Models Extension Certification<br />

Samsung<br />

(ONVIF)<br />

• SNB-7000<br />

• SND-5080<br />

• SNV-5080<br />

Generic Plus (ONVIF)<br />

Certified<br />

• SNB-5000<br />

• SND-7080<br />

• SNP-5200<br />

• SNV-5010<br />

• SNV-5080R<br />

• SNV-7080<br />

• SNZ-5200<br />

• SPE-100<br />

• SPE-400<br />

Generic Plus (ONVIF)<br />

Supported by design<br />

Scallop Imaging • D7-180 <strong>Genetec</strong> Tested by partner<br />

Vivotek<br />

(ONVIF)<br />

• IP8161<br />

• IP8362<br />

• VS8102<br />

Generic Plus (ONVIF)<br />

Supported by design<br />

Supported Bosch intrusion detection units<br />

<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> supports the following Bosch GV2 and GV3 alarm panel devices.<br />

For each device, the corresponding firmware and certification status is listed.<br />

Model Device Firmware Certification<br />

D9412GV2/GV3 Alarm panel GV2: ver.7.08<br />

GV3: ver. 8.05<br />

Certified<br />

D1255 Keypad Certified<br />

DX4010V2 USB/Serial interface module Certified<br />

DX4020 Ethernet Network Interface Module Certified<br />

D8128D Input expansion module Certified<br />

D8125 Addressable expansion module Certified<br />

D7412GV2/GV3 Alarm panel Use most recent<br />

version<br />

D7212GV2/GV3 Alarm panel Use most recent<br />

version<br />

Supported by design<br />

Supported by design<br />

D8129 Octo-Relay module Supported by design<br />

D125B Dual Class B Initiating Module Supported by design<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 14<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Supported hardware<br />

Model Device Firmware Certification<br />

D9127 POPIT modules Supported by design<br />

DS7432 Eight-input Remote Module Supported by design<br />

DS7457i Single Zone Multiplex Input module Supported by design<br />

DS7460i Dual-input module Supported by design<br />

DS7461i Single-input Multiplex module Supported by design<br />

DS7465i Input and Output Module Supported by design<br />

DX4010i RS-232 Serial Interface Module Supported by design<br />

Supported Honeywell Galaxy intrusion detection devices<br />

<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> supports the following Honeywell Galaxy Dimension control panel<br />

devices. For each device, the corresponding firmware and certification status is listed.<br />

Model Device Firmware Certification<br />

A234 RS-232 Lead Kit Certified<br />

C072 Rio Expander module Certified<br />

CP037 Keypad Certified<br />

GD-48 Control panel Version 6.7 and later Certified<br />

GD-96 Control panel Version 6.7 and later Supported by design<br />

GD-264 Control panel Version 6.7 and later Supported by design<br />

GD-520 Control panel Version 6.7 and later Certified<br />

For more information on the known issues and limitations for Honeywell Galaxy<br />

Dimension control panel devices in this release, see the Honeywell Galaxy Control Panel<br />

Integration Plugin User Guide <strong>5.1</strong> <strong>GA</strong>.<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 15<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Supported hardware<br />

Supported HID units<br />

This section includes the following topics:<br />

• "HID unit compatibility" on page 16<br />

• "HID unit known issues" on page 17<br />

• "HID unit limitations" on page 17<br />

HID unit compatibility<br />

<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> is compatible with the following HID unit firmware versions:<br />

HID VertX<br />

2.2.7.18<br />

2.2.7.39<br />

2.2.7.49.1<br />

2.2.7.70 a<br />

HID EdgeReader / EdgePlus<br />

2.2.7.18<br />

2.2.7.39<br />

2.2.7.49.1<br />

2.2.7.70<br />

a.Version 2.2.7.70 does not support elevator control and<br />

V1000 with 12 to 16 interface modules connected. If these<br />

features are required, you’ll need to downgrade to<br />

2.2.7.49.1.<br />

HID units should have the following Program and EEPROM firmware:<br />

HID interface unit Program EEPROM<br />

V100<br />

V2000 (has a V100 interface board built-in)<br />

EdgePlus/EdgeReader<br />

113 110<br />

V200 106 105<br />

V300 107 104<br />

For instructions on how to upgrade a unit’s firmware, see the <strong>Security</strong> <strong>Center</strong> Administrator<br />

Guide.<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 16<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Supported hardware<br />

HID unit known issues<br />

The HID units supported by <strong>Security</strong> <strong>Center</strong> include the following known issues.<br />

Issue<br />

Description<br />

57112 Unit discovery does not show the new name you give to a unit (in the unit,<br />

Identities tab) until the unit is rebooted or its power is cycled.<br />

57113 When a Door unlock schedule override is removed, there is a delay of 40<br />

seconds before the door’s unit is fully programmed.<br />

3461 V200/V300: Periodic output behavior does not always toggle properly.<br />

Recommendation: Set output transitions for a minimum duration of 5<br />

seconds or more.<br />

56493 HID VertX V1000: On the first attempt, <strong>Security</strong> <strong>Center</strong> may not be able to<br />

add a VertX V1000 unit (2.2.7.78). The first time you try to add a VertX<br />

V1000 (2.2.7.78) to <strong>Security</strong> <strong>Center</strong>, an error appears. <strong>Security</strong> <strong>Center</strong> will<br />

then reboot the unit. After the unit is rebooted, the second time you try to<br />

add the unit, <strong>Security</strong> <strong>Center</strong> is able to add the unit to the system.<br />

HID unit limitations<br />

The HID units supported by <strong>Security</strong> <strong>Center</strong> include the following known limitations.<br />

Issue<br />

Description<br />

57114 AC fail inputs: If the VertX V1000 AC Fail input is used to monitor AC, then the<br />

AC Fail inputs on all interface modules (V100, V200, V300) controlled by the<br />

V1000 must only be used for monitoring AC. Similarly, if the V1000 AC Fail is<br />

used as a general purpose input, the AC Fail interface modules must only be<br />

used for general purpose inputs.<br />

57115 Battery fail inputs: If the VertX V1000 Battery Fail input is used to monitor<br />

battery failure, then the Battery Fail inputs on all interface modules (V100,<br />

V200, V300) controlled by the V1000 must only be used for monitoring battery<br />

failure. Similarly, if the V1000 Battery Fail is used as a general purpose input, the<br />

Battery Fail interface modules must only be used for general purpose inputs.<br />

57116 The HID VertX V1000 inputs and outputs cannot be used for the following<br />

purposes:<br />

• A door REX, door sensor, door lock<br />

• Elevator control or floor tracking<br />

• Interlock, including the override or lockdown functions<br />

• Readerless door<br />

• IO linking (Zone)<br />

• Door buzzer<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 17<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Supported hardware<br />

57118 The HID Edge device (EdgeReader or EdgePlus) can only be used to control a<br />

single door. You cannot use two HID Edge devices to configure a door with two<br />

readers. The supported configuration for an Edge device is a card-in /REX-out<br />

door.<br />

57119 You must stop the Access Manager before initiating a unit swap operation in the<br />

Config Tool. Once the swap is completed, the Access Manager can be restarted.<br />

Where to find more information about supported hardware<br />

• Video unit compatibility. For details such as firmware and certification status of the<br />

hardware supported by <strong>Security</strong> <strong>Center</strong>, see the Supported Devices list on <strong>Genetec</strong>'s<br />

Technical Assistance Portal (GTAP), at https://gtap.genetec.com. You’ll need a username<br />

and password to log on to GTAP.<br />

• <strong>Security</strong> <strong>Center</strong> Video Unit Configuration Guide. Some of the supported video units<br />

require additional configuration before they can be added in <strong>Security</strong> <strong>Center</strong>, or for<br />

their unit features to work in <strong>Security</strong> <strong>Center</strong>. For more information about these configuration<br />

steps, see the <strong>Security</strong> <strong>Center</strong> Video Unit Configuration Guide. The latest version<br />

of this document is available at:<br />

http://downloads.genetec.com/<strong>Security</strong> <strong>Center</strong>/<strong>5.1</strong>/<strong>GA</strong>/<strong>Security</strong>_<strong>Center</strong>/EN.<strong>Security</strong>%20<strong>Center</strong>%20Video%20Unit%20Configuration%20Guide%20<strong>5.1</strong>%20<strong>GA</strong>.pdf.<br />

• Known issues and limitations. For a list of supported hardware known issues and limitations<br />

in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong>, see the GTAP Known Issues page, at https://<br />

gtap.genetec.com. You’ll need a username and password to log on to GTAP.<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 18<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Resolved issues<br />

Resolved issues<br />

This section lists the software and hardware issues that were resolved in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong><br />

<strong>GA</strong>.<br />

Resolved software issues<br />

The following software issues were resolved in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong>.<br />

Issue Solution Description<br />

30056 All After installing or upgrading a <strong>Security</strong> <strong>Center</strong> main server (with Directory<br />

role), the <strong>Genetec</strong> Server service must be restarted.<br />

40466 All Usernames with character '@' or '\' in their name cannot log in.<br />

40392 All <strong>Security</strong> Desk monitoring or reporting tasks display all report fields, even<br />

when those fields are not applicable to the product license.<br />

40382 All “Send email” action sends email twice for certain events.<br />

41140 All Discovery tool option is disabled if the license does not support Synergis.<br />

44483 All Cannot activate <strong>Security</strong> <strong>Center</strong> 5.0 SR1 using web activation.<br />

47683 All Only users with Administrator Privileges can view Investigation Reports.<br />

48728 All SQL 2008 installation fails when installing <strong>Security</strong> <strong>Center</strong> on a main or<br />

expansion server on Windows 2003 64bit.<br />

49614 All Unit Discovery and Unit Replacement Tools are unavailable.<br />

50137 All In Public address field, cannot enter a hostname that starts with digit.<br />

54754 All When modifying an event-to-action, the “Create and edit an action” dialog<br />

box may not display current settings for that action.<br />

29984 Access The battery fail event is not reported on V100, V200, V300 interface panels.<br />

It is only reported on the V1000 master controller.<br />

44384 Access Cannot configure an elevator with more than 10 floors.<br />

49255 Access HID controller must be synchronized before it can be put in maintenance<br />

mode.<br />

50452 Access The image appears stretched when taking a Snapshot for a cardholder<br />

picture from a Federated camera.<br />

55862 Access Cardholder Management task labels are incorrect.<br />

40396 Video Changing the discovery port on an Archiver for Bosch video hardware does<br />

not replace the original port, but rather adds a second discovery port.<br />

Consequently, the wrong video streams may be displayed and recorded.<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 19<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Resolved issues<br />

Issue Solution Description<br />

40469 Video Deleting a camera from one archiver and adding it to another does not<br />

change its recording setting (Inherit from Archiver).<br />

40339 Video It may be possible to add more cameras than allowed by the system license.<br />

40600 Video When attaching a PTZ camera to a door and assigning a PTZ preset, only<br />

the first seven presets are available.<br />

49891 Video DVMRe images are upside down in <strong>Security</strong> Desk.<br />

50871 Video Live video freezes when switching between cameras in <strong>Security</strong> Desk.<br />

53551 Video Playback does not work properly when done from multiple networks.<br />

53859 Video Omnicast Federation role may time out when “Signal lost” events occurs.<br />

54019 Video If you are using two network interface cards (NICs) on your <strong>Security</strong><br />

<strong>Center</strong> server (for example, if all your cameras are on one network and all<br />

your client workstations are on a different network), you may not be able to<br />

view live or playback video, and the cameras will show the message<br />

“Waiting for signal”.<br />

54437 Video When displaying an HTML map in a bottom tile, and switching a camera in<br />

another tile to playback mode, the map overlaps the video thumbnails.<br />

56398 Video Pelco9760 and Pelco KDB300 do not work in <strong>Security</strong> Desk.<br />

57022 Video Video export missing first watermarked sequence.<br />

Resolved hardware issues<br />

The following video unit hardware issues were resolved in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong>. This lists<br />

is categorized by manufacturer and/or extension.<br />

Issue Manufacturer Description<br />

1395 ACTi ACTi–CAM65xx/66xx: Some Dynacolor PTZ commands are not<br />

working (ex. Run a pattern).<br />

45696 ACTi Motion off events are not generated when using Full Screen (Unit)<br />

motion detection on an ACM-5611 unit.<br />

24690 Arecont When using an H.264 stream: The AV8185 and AV8365 units do<br />

not support Unicast TCP.<br />

29424 Arecont Software motion detection is not supported on AV10005 units.<br />

49665 Interlogix UVE-101, UVD-IP-EVRDNR-VA2, and UVD-IP-XP3DNR-VA2:<br />

Still frame alarms do not work.<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 20<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Resolved issues<br />

Issue Manufacturer Description<br />

23952 Panasonic Panasonic WV-SP102: 1280x960 and 1280x720 resolutions are<br />

visible in the Config Tool even though they are not supported by<br />

the unit.<br />

27480 Panasonic DG-SC385: The connection type under the Specific settings tab is<br />

incorrect in some cases.<br />

45531 Panasonic For some unit and firmware combinations, software motion<br />

detection does not analyze the bottom part (approx. 10%) of the<br />

video image in MPEG-4 streaming.<br />

29121 Sanyo (ONVIF) VCC-HD5400: After switching from 30 fps to a higher resolution,<br />

the frame rate cannot be reset to 30 fps.<br />

29244 Sanyo (ONVIF) VCC-HD4600: Pan/tilt commands have no effect on the unit.<br />

29475 Sanyo (ONVIF) VCC-HD4600, VCC-HD5400, and VCC-HD5600: When using<br />

H.264 streaming, RTSP over TCP, multiple unit lost/discovered<br />

events occur while performing a guard tour.<br />

49666 Sanyo (ONVIF) VDC-HD3500, VCC-HD5600: Sometimes the units cannot be<br />

added.<br />

49667 Sanyo (ONVIF) The first PTZ preset cannot be modified with the set/clear preset<br />

commands. The camera position can only be changed using the<br />

SetHomePosition command.<br />

49669 Sanyo (ONVIF) VCC-HD5400, VCC-HD5600: Presets do not work in Omnicast.<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 21<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Known issues<br />

Known issues<br />

<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> includes the following known issues.<br />

NOTE SD stands for <strong>Security</strong> Desk, and CT stands for Config Tool.<br />

Issue Solution Description<br />

21823 All CT: For languages written from right to left, such as Arabic and<br />

Persian, the user interface of some tools and configuration tabs in the<br />

Config Tool may not have been inverted.<br />

56399 All CT: Deleting a unit does not remove the references to its devices in the<br />

configuration of other entities, such as zones.<br />

Workaround: Manually remove the references to devices of deleted<br />

units from other entity configurations.<br />

56928 All Sometimes the event-to-actions list in the Action tab is not<br />

automatically updated.<br />

Workaround: Manually refresh the page by clicking another tab in<br />

General Settings, and then clicking the Actions tab.<br />

56965 All <strong>Security</strong> <strong>Center</strong> stops responding when trying to run a backup on a<br />

folder that does not exist.<br />

56972 All CT: Deleting a role's database whose status is Not connected, may<br />

cause the role to go offline. To bring the role back online, you'll need<br />

to click Deactivate role and then Activate role.<br />

57687 All Federation: When generating an event report on a federation host<br />

with multiple federated systems having custom events defined, the<br />

event sources are sometimes mixed up.<br />

57800 All SD/CT: Under Windows XP, the drop-down menu sometimes appears<br />

behind the window it belongs to.<br />

57908 All SD: When multiple messages are received (via Send a message action)<br />

and not read, only the first one generates an alert in the notification<br />

tray and is logged.<br />

57799 All SD: In Guard Tour mode, when “Tile only” view is selected, the<br />

dashboard may appear briefly.<br />

58186 All SD/CT: Custom filter applied using the Search dialog box does not<br />

always display properly.<br />

Workaround: Select the control where the selection is supposed to<br />

appear and do a right mouse-click or press F5.<br />

59249 All Licensing: An unhandled exception occurs after applying a license.<br />

Workaround: Refresh the Server Admin page and reapply the license.<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 22<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Known issues<br />

Issue Solution Description<br />

59831 All Information about query results greater than 500 appears as<br />

an error message ("error occurred while processing" or "Query<br />

failure"), leading the user to think an error occurred.<br />

This message should be displayed as an information message, not as an<br />

error message, since <strong>Security</strong> <strong>Center</strong> is letting the user know that the<br />

report is not displaying images in order to prevent timeout errors.<br />

59916 All SD: The Alarms list in the Actions tab of the Monitoring task is not<br />

populated until a Trigger alarm Hot action is created.<br />

59968 All SD: Email sent for an “Email report” hot action contains wrong report<br />

title.<br />

59982 All SD: Events filter does not work for Zone activities report.<br />

60932 All CT - Entities created with a wrong relationship (for example, a door<br />

under a door or a zone under a door) are not displayed in the Logical<br />

view.<br />

Workaround:<br />

1 Use the filter to find the new entity you just created.<br />

2 Delete it.<br />

3 Recreate the entity under an area in the Logical view.<br />

40220 Access SD: “Door locked” and “Door unlocked” events are not shown in the<br />

Door activity report.<br />

40596 Access The limitations when triggering outputs in a zone are as follows:<br />

• The entry delay is applied for both the Normal-to-Active and<br />

Active-to-Normal zone state transitions.<br />

• When an Active-to-Normal zone state transition occurs, all<br />

corresponding event-to-actions will launch immediately except for<br />

the trigger output, which will launch after entry delay expires.<br />

57416 Access Move unit: Access control unit stays offline after moving it from one<br />

Access Manager to another.<br />

Workaround: Manually restart the Access Manager after moving the<br />

unit.<br />

57748 Access Global Cardholder Management: Adding entities to a global partition<br />

on the sharing host while sharing guests are synchronizing with it<br />

might cause a synchronization error to be logged.<br />

Workaround: Repeat the synchronization manually.<br />

58001 Access Cardholder Management: Cardholder search does not work in Cards<br />

view.<br />

Workaround: Use Details view instead.<br />

58207 Access Cannot use the copy configuration tool to copy access rules.<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 23<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Known issues<br />

Issue Solution Description<br />

59077 Access CT - VertX units: After changing the Analog 2 Digital (A/D) input<br />

calibration value, the Refresh button becomes unavailable.<br />

Workaround: On the Properties page, click another input or output.<br />

The Refresh button reappears.<br />

59075 Access CT - VertX units: Cannot refresh or view current Analog 2 Digital<br />

(A/ D) values, when Config Tool window is at it's minimum size.<br />

59362 Access Cardholder Management: Cropping feature does not crop the area<br />

defined by the user.<br />

59530 Acess CT: Not all required fields for Honeywell intrusion detection units are<br />

validated by the entity creation wizard.<br />

Workaround: When creating a Honeywell intrusion detection unit,<br />

the Account number and the Remote user code must be numeric and<br />

not exceed 6 digits each.<br />

59965 Access The Area presence and People counting reports do not report on<br />

newly added access control units.<br />

Workaround: After adding an access control unit to an Access Manager,<br />

deactivate and reactivate the Access Manager, and then run the<br />

reports.<br />

60634 Access Global Cardholder Management: The first scheduled synchronization<br />

fails.<br />

Workaround: Perform a manual synchronization first. The following<br />

scheduled synchronizations will then run successfully.<br />

52686 Video When a server is configured as a proxy (with a public address) on a<br />

network, all stream requests are redirected through it, even when the<br />

request is issued from inside the network.<br />

Workaround: To avoid having the proxy server becoming a bottleneck,<br />

create a dummy network entity and assign the proxy server to it.<br />

55909 Video Panasonic BB-HCM735: PTZ coordinates dialog box does not display<br />

Pan, Tilt, Zoom coordinates.<br />

Workaround: Using the PTZ widget, change the PTZ position. The<br />

PTZ dialog is updated and displays the PTZ coordinates.<br />

57147 Video SD: Viewing multiple video streams federated from Omnicast 4.x in<br />

synchronized playback mode does not always work.<br />

57265 Video SD: When you move playback to the beginning of a sequence, audio<br />

may stop. To turn audio back on, click Listen twice.<br />

57433 Video Auxiliary Archiver: No warning message appears when adding a<br />

network location that does not meet minimum space requirements.<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 24<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Known issues<br />

Issue Solution Description<br />

57553 Video Auxiliary Archiver: when you deactivate and activate the role, a<br />

warning appears briefly on screen. This is a false-positive warning<br />

notification.<br />

57555 Video Archiver: When you move a unit to a new Archiver, the destination<br />

archiver does not automatically add the extension to support the<br />

camera.<br />

57634 Video Export: When exporting a video sequence that straddles the recording<br />

schedules of multiple Archivers and Auxiliary Archivers, some<br />

segments of the selected video sequence might be missing from the<br />

export.<br />

57829 Video SD: The playback timeline might not display correctly when switching<br />

between valid and invalid video sources.<br />

Workaround: Select the valid playback source a second time.<br />

57915 Video Export: When exporting video with a specific playback source from<br />

the tile, the export dialog does not remember the selected playback<br />

source.<br />

Workaround: Select again the source from the export dialog box.<br />

58555 Video CT: PTZ calibration for the direct XYZ positioning feature is very<br />

difficult because the specific field of view parameters are not supplied<br />

by default for the specific camera model.<br />

58892 Video Video feed may flicker when changing the resolution.<br />

59245 Sentry 360 Camera may stop responding and require a power cycle to come back<br />

online.<br />

60803 Sentry 360 In the Config Tool Video tab, the M-JPEG tab is available, even<br />

though M-JPEG is not supported.<br />

60818 Sentry 360 Frame rate changes are not applied to the video stream.<br />

60836 Sentry 360 When using the dewarping feature in <strong>Security</strong> Desk, the zoomed 360 o<br />

image does not support pan/tilt hand grip manipulation.<br />

60837 Sentry 360 When using the dewarping feature in <strong>Security</strong> Desk, the image<br />

thumbnail does not exactly match what is shown in the zoomed<br />

image.<br />

60838 Sentry 360 When using the dewarping feature in <strong>Security</strong> Desk, you cannot<br />

navigate the zoomed image using your keyboard arrows.<br />

60839 Sentry 360 When using the dewarping feature in <strong>Security</strong> Desk, if you zoom<br />

using your mouse wheel button, it zooms to the center of the image,<br />

not where your mouse is pointing.<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 25<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Known issues<br />

Issue Solution Description<br />

60840 Sentry 360 When using the dewarping feature in <strong>Security</strong> Desk, the overview<br />

image does not match the zoom regions.<br />

60841 Sentry 360 When using the dewarping feature in <strong>Security</strong> Desk, the overview<br />

image displays the first frame when the camera was dropped in the<br />

tile.<br />

60643 Sentry 360 Cameras using H.264 can produce large increases in bandwidth usage<br />

that result in video glitches.<br />

Workaround: Install camera on a Gigabit network.<br />

60026 Upgrading When upgrading a secondary Archiver server, the Archiver role does<br />

not automatically fail back to the primary Archiver server, resulting in<br />

the loss of video recordings during the upgrade period.<br />

Workaround:<br />

Before you upgrade the secondary Archiver server, you'll need to stop<br />

the ArchiverDomain service on the secondary Archiver server.<br />

1 Upgrade the main server.<br />

The primary Archiver server continues to record video.<br />

2 Upgrade the primary Archiver server.<br />

The Archiver role fails over to the secondary Archiver server.<br />

3 On the secondary Archiver server, open the Server Admin console:<br />

from a web browser, type ///genetec/console#/Services.<br />

4 From the Service domains list, select ArchiverDomain, and then<br />

click X at the bottom of the list.<br />

The Archiver role fails back to the primary Archiver server.<br />

5 Upgrade the secondary Archiver server<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 26<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Limitations<br />

Limitations<br />

<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> includes the following known limitations.<br />

NOTE SD stands for <strong>Security</strong> Desk, and CT stands for Config Tool.<br />

Issue Solution Description<br />

10997 All (Ref. 17369) Scheduled tasks with “On startup” recurrence property<br />

may not run on startup. Workaround: Limit the “On startup” tasks to<br />

“Execute a macro” actions.<br />

11280 All The status of a device (camera or door) shown in a <strong>Security</strong> <strong>Center</strong><br />

map is not updated on the map when the device goes temporarily<br />

offline (red) and back online.<br />

Workaround: Remove the map from the canvas and drag it back to<br />

the canvas.<br />

12224 All Time zone abbreviations are not supported in the printed reports.<br />

13097 All The Active Directory role may stop working after the Microsoft Active<br />

Directory domain controller is restarted.<br />

Workaround: Deactivate the role for at least 3 minutes and reactivate<br />

it.<br />

13616 All Database backups cannot be purged when the database server is not<br />

on the same computer as the server role (<strong>Security</strong> <strong>Center</strong> Directory or<br />

Synergis Access Manager).<br />

22169 All Server Admin cannot use the default HTTP port 80 on a Windows XP<br />

32-bit machine if IIS service is installed. (Workaround modify port to<br />

use one other than port 80).<br />

24428 All <strong>Security</strong> Desk keyboard shortcuts cannot be used (such as space to<br />

acknowledge an alarm) when the focus is on a tile displaying a map.<br />

Workaround: Use the command buttons found in the map instead.<br />

51058 All IPV6 is not supported.<br />

56703 All SD: Not all query filters in reporting tasks are updated live when the<br />

system configuration changes, such as when new custom fields or<br />

custom events are added.<br />

Workaround: To view the new query filter options, delete the task and<br />

recreate it.<br />

16721 Access Synergis: Modifying the members (doors, elevators, captive areas) of<br />

an area might disrupt the Time and attendance report of that area for<br />

the time range prior to the change.<br />

Workaround: Restoring the old membership settings also restores the<br />

old time and attendance values.<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 27<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Limitations<br />

Issue Solution Description<br />

21998 Access PIN credential active state is ignored when used with a CARD & PIN<br />

reader. To support units that have a combination of normal readers<br />

and CARD & PIN readers, only the CARD's credential status is used.<br />

19239 Access Elevator control – Configuring an exception to unlock schedule<br />

(controlled access) on a floor without a corresponding unlock<br />

schedule (free access) may cause the VertX controller to stop sending<br />

events to the Access Manager.<br />

37088 Access <strong>Security</strong> <strong>Center</strong> does not support Reactivation threshold settings for<br />

zones entities.<br />

51996 Access When the association between a credential and a badge template is<br />

changed at a remote site (in a roaming environment), this change is<br />

not updated at the central site.<br />

57615 Access Denying a Global Cardholder Synchronizer role the “Modify<br />

credential information” privilege does not prevent its users on the<br />

sharing site from changing the shared PIN credentials.<br />

Workaround: In the context of Global Cardholder Management, in<br />

order to prevent the sharing site users from modifying the shared PIN<br />

credentials, the Global Cardholder Synchronizer roles must be denied<br />

the “Add/delete credentials” privilege on the sharing host.<br />

26345 Intrusion Bosch GV2 alarm panel: If an intrusion area is not ready to be armed,<br />

the alarm panel will still accept the command to arm it. However, it<br />

will only be armed once the intrusion area is actually ready to be<br />

armed.<br />

15199 LPR AutoVu LPR: Sharp units under Patrollers always appear as online in<br />

SD and CT, regardless of their real status, as long as the Patroller is<br />

connected to the LPR Manager external system.<br />

15676 LPR AutoVu LPR: When configuring a permit restriction, it is not possible<br />

to define a time restriction that spans only one day.<br />

16619 LPR AutoVu LPR: While parsing hotlist or permit data files, parsing errors<br />

such as the use of wrong delimiter characters, are not indicated.<br />

Workaround: Always double-check that the files are loaded correctly<br />

in the Patroller.<br />

17892 LPR SD – Geographical map: Regions drawn on maps as filters for certain<br />

type of reports appear on top of the Bing map controls, blocking their<br />

access.<br />

Workaround: Move the map around or zoom in/out with the mouse<br />

wheel.<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 28<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Limitations<br />

Issue Solution Description<br />

18525 LPR AutoVu LPR – SD: When the thumbnail LPR images are not shown in<br />

a LPR report (for queries returning more than 1000 rows), they are not<br />

displayed in the tiles either.<br />

Workaround: Click on the “Magnifying glass” button in the tile to display<br />

the LPR image.<br />

20489 LPR SD: The timestamp associated to a hit corresponds to the time the<br />

patrolling officer took action on the hit (Accepted, Rejected, or Not<br />

enforced), not the time the hit was raised.<br />

25725 LPR LPR Manager database cleanup begins when the LPR Manager<br />

database table reaches 20,000 reads. Previously, the LPR Manager<br />

database cleanup did not start until the database table reached<br />

100,0000 reads. If using SQL 2008 Express, the database could not<br />

reach 100,000 reads before reaching the 4 GB limit in SQL Express.<br />

26008 LPR While upgrading <strong>Security</strong> <strong>Center</strong> from 4.0 to 5.0, the server and<br />

database used in 4.0 are not automatically reassigned to the LPR<br />

Manager role in 5.0.<br />

Workaround: You need to reassign the resources manually in the<br />

Config Tool.<br />

56903 LPR In Config Tool, after moving a Patroller unit to another LPR Manager,<br />

it still appears under the previous LPR Manager.<br />

Workaround: Click Refresh in the Entity browser.<br />

57731 LPR Moving a Patroller unit to a new LPR Manager requires additional<br />

setting changes in Patroller Config Tool. For more information, see<br />

“Move Patroller or LPR units betweenLPR Managers” in the AutoVu<br />

Handbook.<br />

11781 Video If live video is displayed in a tile before any recording took place, then<br />

switching the display mode to playback will not show any recorded<br />

video even after the recording took place.<br />

11998 Video Omnicast 4 alarm priorities are not converted when federated in the<br />

<strong>Security</strong> <strong>Center</strong>. All federated Omnicast alarms have a priority of 1.<br />

Workaround: Adjust the priorities of federated Omnicast alarms<br />

manually in the Config Tool.<br />

12908 Video The nVidia video card may cause the <strong>Security</strong> Desk to stop working<br />

when hardware acceleration is turned on and set to “Full”.<br />

Workaround: Set hardware acceleration to “None”.<br />

13195 Video If UltraVNC is installed on a computer, the <strong>Security</strong> Desk may be<br />

unable to display video.<br />

Workaround: Uninstall UltraVNC.<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 29<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Limitations<br />

Issue Solution Description<br />

25318 Video Federated camera sequences does not show video from cameras that<br />

are blocked to any user on the remote system, regardless of the<br />

privileges of the user account used to connect to the federated<br />

Directory.<br />

25322 Video All cameras in a federated camera sequence are displayed on the<br />

federation host even though the user account used to connect to the<br />

federated Directory does not have access to all of them.<br />

28991 Video SD: When displaying an HTML map in a tile while viewing video in<br />

the tile next to it, the map will overlap the video thumbnails.<br />

40314 Video Alarm playback loop is permanently set in <strong>Security</strong> Desk.<br />

The alarm playback loop is set between the following time ranges:<br />

• Start time: Alarm trigger minus pre-trigger setting.<br />

• End time: Alarm trigger plus 10 seconds.<br />

52172 Video When attempting to back up an Auxiliary Archiver that is installed on<br />

an expansion server to a file on that computer, you may receive an<br />

error because the SQL Server may not have permission to back up to<br />

that location.<br />

Workaround: Back up to a folder the SQL Server has access to.<br />

58329 Video Backward compatibility: <strong>Security</strong> Desk 5.0 and earlier cannot play<br />

AAC audio coming from <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong>.<br />

58556 Video SD: Using the direct XYZ positioning feature (cursor shown as a cross)<br />

to pan the camera in one direction will block when the camera reaches<br />

the limit of its pan-tilt range. The wrap around is not automatic.<br />

Workaround: Switch to normal pan-tilt-zoom (click and drag from<br />

the blue center dot) to position the camera to where you want it to<br />

point.<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 30<br />

EN.500.001-V<strong>5.1</strong>.B(6)


System requirements<br />

System requirements<br />

For system requirements, see the <strong>Security</strong> <strong>Center</strong> Installation and Upgrade Guide. The latest<br />

version of this document is available at: http://downloads.genetec.com/<strong>Security</strong> <strong>Center</strong>/<strong>5.1</strong>/<br />

<strong>GA</strong>/Securitization/EN.<strong>Security</strong> <strong>Center</strong> Installation and Upgrade Guide <strong>5.1</strong> <strong>GA</strong>.pdf.<br />

Supported languages<br />

<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> software is available in the following languages:<br />

• Arabic<br />

• Dutch<br />

• English<br />

• French<br />

• German<br />

• Hebrew<br />

• Hungarian<br />

• Italian<br />

• Japanese<br />

• Korean<br />

• Persian<br />

• Polish<br />

• Portuguese–Brazil<br />

• Spanish<br />

• Simplified Chinese and Traditional Chinese<br />

• Thai<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 31<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Supported upgrades<br />

Supported upgrades<br />

Before you begin: Please note the following:<br />

• Synergis Web Client is not available in <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong>. If you are using the Synergis<br />

Web Client, you should wait to upgrade until Mobile 3.0 is released.<br />

• Upgrading AutoVu Patroller. In <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong>, the LPR feature enhancements<br />

are only for Law Enforcement. Only upgrade to <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> if you are using<br />

the Patroller Law Enforcement installation type.<br />

<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> supports the following upgrade paths:<br />

• <strong>Security</strong> <strong>Center</strong> 3.0 (<strong>GA</strong> and SR1) to <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong><br />

• <strong>Security</strong> <strong>Center</strong> 4.0 (<strong>GA</strong> and SR1) to <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong><br />

• <strong>Security</strong> <strong>Center</strong> 5.0 (<strong>GA</strong> and SR1) to <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong><br />

Supported upgrades from Synergis 2.1<br />

You cannot upgrade directly from Synergis 2.1 to <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong>. To upgrade, you’ll<br />

need to do the following:<br />

1 Upgrade from Synergis 2.1 to <strong>Security</strong> <strong>Center</strong> 4.0 SR1.<br />

For more information, see “Upgrading from Synergis 2.1” in the <strong>Security</strong> <strong>Center</strong> 4.0<br />

SR1 Installation and Upgrade Guide, available at:<br />

http://downloads.genetec.com/<strong>Security</strong><strong>Center</strong>/4.0/SR1/EN.<strong>Security</strong> <strong>Center</strong> Installation<br />

and Upgrade Guide 4.0 SR1.pdf<br />

2 Upgrade from <strong>Security</strong> <strong>Center</strong> 4.0 to <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong>.<br />

Supported Omnicast migration paths<br />

<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> supports migrations from Omnicast 4.5 and later. For more<br />

information, see “Migrating from Omnicast 4.5 and later” in the <strong>Security</strong> <strong>Center</strong> Installation<br />

and Upgrade Guide. The latest version of this document is available at: http://<br />

downloads.genetec.com/<strong>Security</strong> <strong>Center</strong>/<strong>5.1</strong>/<strong>GA</strong>/Securitization/EN.<strong>Security</strong> <strong>Center</strong><br />

Installation and Upgrade Guide <strong>5.1</strong> <strong>GA</strong>.pdf.<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 32<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Supported AutoVu migration paths<br />

Supported AutoVu migration paths<br />

<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> does not support migrations from AutoVu 4.3. You must migrate<br />

AutoVu 4.3 data to <strong>Security</strong> <strong>Center</strong> 5.0 SR1 using the Data import tool. For more<br />

information, see “Migrating from AutoVu 4.3” in the <strong>Security</strong> <strong>Center</strong> 5.0 SR1 Installation<br />

and Upgrade Guide. The latest version is available at: http://downloads.genetec.com/<br />

<strong>Security</strong><strong>Center</strong>/5.0/SR1/<strong>Security</strong>_<strong>Center</strong>/EN.<strong>Security</strong> <strong>Center</strong> Installation and Upgrade<br />

Guide 5.0 SR1.pdf<br />

Supported federations<br />

The <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> supports the following federations:<br />

• <strong>Security</strong> <strong>Center</strong> 4.0 <strong>GA</strong> and SR1, 5.0 <strong>GA</strong> and SR1, <strong>5.1</strong> <strong>GA</strong><br />

• Omnicast 4.2, 4.6, 4.7, and 4.8<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 33<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Compatibility<br />

Compatibility<br />

This section describes how <strong>Security</strong> <strong>Center</strong> components work together with other <strong>Security</strong><br />

<strong>Center</strong> components and other <strong>Genetec</strong> products.<br />

<strong>Security</strong> <strong>Center</strong> backward compatibility<br />

<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> is backward compatibile with a number of <strong>Security</strong> <strong>Center</strong> 5.0 (<strong>GA</strong><br />

and SR1) components, allowing the system administrator to upgrade the system in stages.<br />

IMPORTANT The main server hosting the Directory role and Config Tool must be upgraded<br />

to <strong>5.1</strong> <strong>GA</strong>.<br />

NOTE<br />

• A <strong>Security</strong> <strong>Center</strong> server must be upgraded in order to use the new features introduced<br />

in version <strong>5.1</strong> <strong>GA</strong>.<br />

• If a role is assigned to multiple servers (failover configuration), all its servers must be<br />

running the same version of <strong>Security</strong> <strong>Center</strong>.<br />

• Legends:<br />

• – Backward compatible<br />

• X – Upgrade required<br />

• NA – Not applicable (only introduced in <strong>5.1</strong> <strong>GA</strong>)<br />

Backward compatibility with <strong>Security</strong> <strong>Center</strong> 5.0 roles<br />

<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong>’s backward compatibility with <strong>Security</strong> <strong>Center</strong> 5.0 (<strong>GA</strong> and SR1)<br />

roles is summarized in the following table.<br />

Role type<br />

Media Router<br />

Access Manager<br />

Archiver<br />

Auxiliary Archiver<br />

Active Directory<br />

Intrusion Manager<br />

Backward compatibility to 5.0 (<strong>GA</strong> and SR1)<br />

X<br />

<br />

<br />

NA<br />

Since the Active Directory role is a single instance role<br />

in 5.0, you need to upgrade the old server to <strong>5.1</strong> <strong>GA</strong><br />

before you can add additional instances of this role to<br />

your new system.<br />

<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 34<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Compatibility<br />

Role type<br />

<strong>Security</strong> <strong>Center</strong> Federation<br />

Omnicast Federation<br />

Plugin Manager<br />

LPR Manager<br />

Point of Sale<br />

Directory Manager<br />

Health Monitor<br />

Global Cardholder Synchronizer<br />

Backward compatibility to 5.0 (<strong>GA</strong> and SR1)<br />

<br />

<br />

X<br />

X<br />

X<br />

NA<br />

NA<br />

NA<br />

Backward compatibility with <strong>Security</strong> Desk 5.0 tasks<br />

<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong>’s backward compatibility with <strong>Security</strong> Desk 5.0 (<strong>GA</strong> and SR1) tasks<br />

is summarized in the following table.<br />

Task category<br />

Task type<br />

Backward compatibility to<br />

<strong>Security</strong> Desk 5.0 (<strong>GA</strong> and SR1)<br />

Operation Monitoring <br />

Cardholder management<br />

Visitor management<br />

People counting<br />

Crendential management<br />

Hotlist and permit editor<br />

Inventory management<br />

<br />

<br />

<br />

<br />

X<br />

X<br />

Investigation Incidents <br />

Zone activities<br />

Transactions<br />

<br />

X<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 35<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Compatibility<br />

Task category<br />

Investigation<br />

/Access control<br />

Investigation<br />

/Asset management<br />

Investigation<br />

/Intrusion detection<br />

Investigation<br />

/LPR<br />

Task type<br />

Area activities<br />

Door activities<br />

Cardholder activities<br />

Visitor activities<br />

Area presence<br />

Time and attendance<br />

Credential activities<br />

Elevator activities<br />

Visit details<br />

Asset activities<br />

Asset inventory<br />

Intrusion detection area activities<br />

Intrusion detection unit events<br />

Hits<br />

Reads<br />

Route playback<br />

Inventory report<br />

Daily usage per Patroller<br />

Logons per Partroller<br />

Reads/hits per day<br />

Reads/hits per zone<br />

Zone occupancy<br />

Backward compatibility to<br />

<strong>Security</strong> Desk 5.0 (<strong>GA</strong> and SR1)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

X<br />

X<br />

<br />

<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 36<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Compatibility<br />

Task category<br />

Investigation<br />

/Video<br />

Task type<br />

Archives<br />

Bookmarks<br />

Motion search<br />

Camera events<br />

Forensic search<br />

Backward compatibility to<br />

<strong>Security</strong> Desk 5.0 (<strong>GA</strong> and SR1)<br />

<br />

<br />

<br />

<br />

NA<br />

Maintenance System status <br />

Maintenace<br />

/Access control<br />

Maintenance<br />

/Video<br />

Audit trails<br />

Activity trails<br />

Health history (5.0)<br />

Health history (<strong>5.1</strong>)<br />

Health statistics<br />

Access control unit events<br />

Cardholder access rights<br />

Door troubleshooter<br />

Access control unit configuration<br />

Access rule configuration<br />

Cardholder configuration<br />

Credential configuration<br />

IO configuration<br />

Archiver events<br />

Archiver storage details<br />

<br />

<br />

The <strong>Security</strong> Desk 5.0 Heath<br />

history task has been renamed<br />

to Access control health history<br />

in <strong>5.1</strong> <strong>GA</strong>.<br />

NA – The Health history in <strong>5.1</strong> <strong>GA</strong><br />

is a new task.<br />

NA<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 37<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Compatibility<br />

Task category<br />

Task type<br />

Backward compatibility to<br />

<strong>Security</strong> Desk 5.0 (<strong>GA</strong> and SR1)<br />

Alarm management Alarm monitoring Moved to Operation tasks in<br />

<strong>5.1</strong> <strong>GA</strong>.<br />

Alarm report<br />

Moved to Investigation tasks in<br />

<strong>5.1</strong> <strong>GA</strong>.<br />

<strong>Security</strong> <strong>Center</strong> Media Router compatibility<br />

The <strong>Security</strong> <strong>Center</strong> Media Router can only redirect <strong>Security</strong> <strong>Center</strong> video streams. The<br />

<strong>Security</strong> <strong>Center</strong> Media Router cannot stream video from federated Omnicast systems.<br />

Video streams from federated Omnicast systems are streamed directly to the <strong>Security</strong> Desk<br />

client using the Omnicast Compatibility Pack. This means that the <strong>Security</strong> Desk client<br />

must be able to connect directly to the Omnicast server.<br />

For information about installing the Omnicast Compatibility Pack, see the <strong>Security</strong> <strong>Center</strong><br />

Installation and Upgrade Guide. The latest version of this document is available at: http://<br />

downloads.genetec.com/<strong>Security</strong> <strong>Center</strong>/<strong>5.1</strong>/<strong>GA</strong>/Securitization/EN.<strong>Security</strong> <strong>Center</strong><br />

Installation and Upgrade Guide <strong>5.1</strong> <strong>GA</strong>.pdf.<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 38<br />

EN.500.001-V<strong>5.1</strong>.B(6)


Compatibility<br />

Omnicast compatibility<br />

IMPORTANT The <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> Archiver role and the Omnicast 4.x Archiver service<br />

cannot run on the same server.<br />

If the Archiver role is not running on the Omnicast server, then <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> can<br />

coexist on the same server as Omnicast.<br />

Best practice: If Omnicast supports more than 30 cameras, it is best practice to host <strong>Security</strong><br />

<strong>Center</strong> and Omnicast on different computers.<br />

<strong>Security</strong> <strong>Center</strong> and Patroller compatibility<br />

Sharp compatibility<br />

AutoVu Patroller <strong>5.1</strong> <strong>GA</strong> is compatible with <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong>.<br />

To use any Sharp camera with <strong>Security</strong> <strong>Center</strong> or Patroller <strong>5.1</strong> <strong>GA</strong>, you need to upgrade<br />

Sharp drivers and services using the new Sharp Upgrade Tool. After upgrading the drivers<br />

and services, you'll also need to upgrade the Sharp firmware. For more information on the<br />

upgrade process, contact your <strong>Genetec</strong> representative.<br />

<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> supports the following AutoVu Sharp cameras:<br />

• Sharp (versions 1.5 and 2.0)<br />

• Sharp EX (version 2.0)<br />

• Sharp V<strong>GA</strong><br />

• SharpX<br />

• SharpX V<strong>GA</strong><br />

IMPORTANT If you are using EX model Sharp cameras with the Patroller, only one LPR<br />

camera can be used per unit.<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 39<br />

EN.500.001-V<strong>5.1</strong>.B(6)


About the documentation in this release<br />

About the documentation in this release<br />

Documents added<br />

Documents replaced<br />

This section describes the documents that were added, updated, or replaced in <strong>Security</strong><br />

<strong>Center</strong> <strong>5.1</strong> <strong>GA</strong>.<br />

This section includes the following topics:<br />

• "Documents added" on page 40<br />

• "Documents replaced" on page 40<br />

• "Supported documentation languages" on page 41<br />

The following documents were added in this release:<br />

• Getting Started with <strong>Security</strong> Desk. Task-oriented introduction to <strong>Security</strong> Desk that<br />

uses real-world scenarios (Viewing a camera, searching/exporting video, and managing<br />

alarms) to show new users how to use the basic product features.<br />

• AutoVu Hardware <strong>Release</strong> <strong>Notes</strong>. Describes the AutoVu Hardware for this release in<br />

detail, including new features, resolved issues, known issues, and limitations.<br />

• AutoVu Handbook. Provides AutoVu installers and administrators with a single<br />

source of information about installing and configuring AutoVu hardware and software.<br />

The following documents were removed in this release:<br />

• AutoVu Hardware Installation Guide. The information from this document was<br />

moved to the AutoVu Handbook.<br />

• AutoVu Patroller Administrator Guide. The information from this document was<br />

moved to the AutoVu Handbook.<br />

• AutoVu Plate Reader Server Administrator Guide. The information from this document<br />

was moved to the AutoVu Handbook.<br />

• SharpX changing LPR unit IP address. The information from this document was<br />

moved to the AutoVu Handbook.<br />

• Creating a <strong>Security</strong> <strong>Center</strong> Map. The information from this document was merged<br />

with the SDK Reference.<br />

• Synergis Web Client Quick Reference. This product was replaced by <strong>Security</strong> <strong>Center</strong><br />

Web Client in <strong>5.1</strong> SR1. Information on how to use the Web Client was moved to the<br />

<strong>Security</strong> <strong>Center</strong> Mobile User Guide.<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 40<br />

EN.500.001-V<strong>5.1</strong>.B(6)


About the documentation in this release<br />

Supported documentation languages<br />

<strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> documentation is available in the following languages:<br />

• All documentation is available in English.<br />

• The following documents are available in French:<br />

• <strong>Security</strong> <strong>Center</strong> <strong>Release</strong> <strong>Notes</strong> (available soon)<br />

• AutoVu Patroller <strong>Release</strong> <strong>Notes</strong><br />

• AutoVu Hardware <strong>Release</strong> <strong>Notes</strong><br />

• AutoVu Patroller Law Enforcement User Guide<br />

• AutoVu Handbook (available soon)<br />

• <strong>Security</strong> Desk User Guide (available soon)<br />

• <strong>Security</strong> <strong>Center</strong> Administrator Guide (available soon)<br />

• The following documents are available in Spanish:<br />

• <strong>Security</strong> Desk User Guide (available soon).<br />

genetec.com | <strong>Security</strong> <strong>Center</strong> <strong>5.1</strong> <strong>GA</strong> <strong>Release</strong> <strong>Notes</strong> | Download latest version 41<br />

EN.500.001-V<strong>5.1</strong>.B(6)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!