<strong>Catalog</strong> <strong>604</strong><br />
Programming Symbols Legend<br />
Pressure Sensors<br />
MPS-32 2-Color Panel Mount<br />
Output 1<br />
Output 2<br />
Output 3<br />
Output 4<br />
Output Normally Closed (Passing)<br />
Output Normally Open (Non-Passing)<br />
Pressure Units (Pascal).<br />
Negative Units for Vacuum Sensors<br />
Pressure Units (Bar).<br />
Negative Units for Vacuum Sensors<br />
Pressure Units (mm.Hg).<br />
Negative Units for Vacuum Sensors<br />
Pressure Units (in.Hg).<br />
Negative Units for Vacuum Sensors<br />
Pressure Units (kgf/cm2).<br />
Negative Units for Vacuum Sensors<br />
Pressure Units (PSI)<br />
Easy Mode. Sensor will only allow<br />
changes to set points<br />
Off, or Energy Saving Display; reduces current<br />
consumption of Sensor<br />
On<br />
Hysteresis Mode. Select Hysteresis<br />
Set Point and Hysteresis Range<br />
Windows Comparative Mode<br />
Select High and Low Set Point<br />
Hysteresis Mode Set Point. Output 1<br />
Hysteresis Mode Set Point. Output 2<br />
Hysteresis Mode.<br />
Hysteresis Range Output 1<br />
Hysteresis Mode.<br />
Hysteresis Range Output 2<br />
Windows Comparative Mode<br />
Low Set Point Output 1<br />
Windows Comparative Mode<br />
High Set Point Output 1<br />
Windows Comparative Mode<br />
Low Set Point Output 2<br />
Windows Comparative Mode<br />
High Set Point Output 2<br />
Automatic Teach Mode. Automatically sets<br />
Outputs 1 and 2 while cycling system. Output 1<br />
set to Hysteresis Mode, Output 2 set to Window<br />
Comparative Mode<br />
Auto Surveillance Mode On/Off.<br />
Set after Automatic Teach<br />
Auto Surveillance based on cycles times.<br />
Provides output if Peak Value is not obtained in<br />
a specified number of cycles. (1-100)<br />
Display Refresh Setting. Display updates from<br />
.1 to 1 sec. .3 sec factory set. Does not affect<br />
Sensor Response Time<br />
Output Response Time. Multiples the sensor<br />
response time. Increases sensor response time.<br />
(Anti-chatter Mode)<br />
Zero Reset<br />
Pressure Value Display Mode. Displays Pressure<br />
for a specific time period and then updates for<br />
next time period<br />
Time Range for Pressure Value Display Mode<br />
Value Setting for Pressure Value Display Mode<br />
Display Peak Value over selected time range<br />
Display Bottom Value over selected time range<br />
Display Difference over selected time range<br />
Display Function Mode. On/Off<br />
Display Function. Selects display types.<br />
Display blinks pressure when Output 1 is Passing<br />
Normal when Output 1 is Non-Passing<br />
Display blinks pressure when Output 2 is Passing<br />
Normal when Output 2 is Non-Passing<br />
Display shows pressure when Output 1 is Passing<br />
Display shows special screen when Non-Passing<br />
Display shows pressure when Output 2 is Passing<br />
Display shows special screen when Non-Passing<br />
Select Switch Output setting for MPS-31<br />
Color Setting for MPS-31<br />
MPS-4, Port Reference Selection<br />
MPS-4, Display change of B port to A port static<br />
MPS-4, Display change of A port to B port static<br />
MPS-4, Display change of A port to<br />
change of B port<br />
MPS-7, Pressure Range Selection Vacuum<br />
MPS-7, Pressure Range Selection Low Pressure<br />
MPS-7, Pressure Range Selection<br />
Positive Pressure<br />
MPS-7, Pressure Range Selection<br />
Compound Pressure<br />
MPS-7, Energy Savings Mode, reduces<br />
current consumption<br />
MPS-7, Peak Surveillance<br />
Digital Input Sensors Only. Digital Input Mode for<br />
remote Zero reset of sensors<br />
Digital Input<br />
Digital Channel<br />
MPS-7 Scan Mode. Sensor scans and displays<br />
each channel for 3 sec.<br />
Locked. Sensor programs cannot be changed<br />
Unlocked. Sensor programs can be changed<br />
Sets Sensors reference point to current<br />
atmospheric conditions<br />
24<br />
<strong>Pneumatic</strong> Division<br />
Richland, Michigan<br />
www.wilkersoncorp.com