RISK OF ELECTRICAL SHOCK.<br />
DO NOT OPEN.<br />
<strong>AudiaFLEX</strong> SPECIFICATIONS<br />
Frequency Response (20Hz~20kHz @ +4dBu):<br />
+0/-0.4dB<br />
Phantom Power:<br />
+48 VDC (7mA/input<br />
THD+N (20Hz~20kHz @ +4dBu):<br />
line level < 0.006%<br />
mic level < 0.04%<br />
Input Gain Range (variable trim):<br />
Sampling Rate:<br />
0dB ~ +66dB<br />
48kHz<br />
Equivalent Input Noise (20Hz~20kHz, 66dB gain, 150 ohm):<br />
-125dBu<br />
A/D - D/A Converters:<br />
24-bit<br />
Dynamic Range (20Hz~20kHz, 0dB):<br />
> 107dB<br />
Power Consumption (100~240VAC 50/60Hz):<br />
< 150 watts<br />
Maximum Gain (input channels):<br />
Crosstalk (channel-to-channel @ 1kHz):<br />
line level<br />
mic level<br />
Output Impedance (balanced):<br />
Input Impedance (mic/line balanced):<br />
Maximum Output (balanced):<br />
Maximum Input (mic/line):<br />
66dB<br />
< -80dB<br />
< -75dB<br />
200 ohms<br />
8k ohms<br />
+24dBu<br />
+24dBu<br />
Dimensions:<br />
height<br />
width<br />
depth<br />
Weight (max. - fully loaded with PA-2 cards):<br />
Compliance:<br />
3.5 inches (89mm)<br />
19 inches (483mm)<br />
11.15 inches (283mm)<br />
15.25 lbs. (6.9kg)<br />
AES48-2005 Grounding & EMC practices<br />
EU Directive 2002/95/EC, RoHS directive<br />
CE marked<br />
UL / C-UL listed<br />
<strong>AudiaFLEX</strong> 12x12CM REAR PANEL DIAGRAM<br />
100-240V~<br />
50/60Hz<br />
Serial Control Port<br />
CAUTION<br />
Installation Instructions: Telephone Interface TI-2<br />
This device must be installed by qualified, trained personnel.<br />
Connections to the telephone network must be made with<br />
#26 AWG solid copper wire for continued safety.<br />
BIAMP SYSTEMS MODEL TI-2<br />
US:6RMBR00BAUDIATI2<br />
IC:3184A-AUDIATI-2<br />
BIAMP SYSTEMS<br />
designed and assembled in the USA<br />
www.biamp.com<br />
150 Watts<br />
In 23<br />
In 21<br />
In 19<br />
In 17<br />
In 15<br />
In 13<br />
In 11<br />
In 9<br />
In 7<br />
In 5<br />
In 3<br />
In 1<br />
CobraNet ® connections only<br />
primary secondary<br />
in use / conductor<br />
LEDs<br />
link / activity<br />
Out 1<br />
In 24<br />
Out 3<br />
In 22<br />
Out 5<br />
In 20<br />
Out 7<br />
In 18<br />
Out 9<br />
In 16<br />
Out 11<br />
In 14<br />
Out 13<br />
In 12<br />
Out 15<br />
In 10<br />
Out 17<br />
In 8<br />
Out 19<br />
In 6<br />
Out 21<br />
In 4<br />
Out 23<br />
In 2<br />
U.S. pat. no. 4,922,536<br />
C<br />
UR<br />
L<br />
US<br />
24VDC<br />
1.5A<br />
Out 2<br />
Out 4<br />
Out 6<br />
Out 8<br />
Out 10<br />
Out 12<br />
Out 14<br />
Out 16<br />
Out 18<br />
Out 20<br />
Out 22<br />
Out 24<br />
LISTED<br />
52SJ<br />
link<br />
Ethernet<br />
term<br />
hi lo<br />
Remote Control Bus<br />
class 2 wiring<br />
YELLOW connectors = AMP OUTPUTS<br />
BLACK connectors = OUTPUTS<br />
ORANGE connectors = AEC INPUTS<br />
GREEN connectors = INPUTS<br />
<strong>AudiaFLEX</strong> BLOCK DIAGRAM<br />
TCP/IP<br />
Control<br />
Comms<br />
Remote<br />
Control<br />
Bus<br />
RS-232<br />
MicroProcessor<br />
Memory<br />
CobraNet<br />
Control<br />
Comms<br />
Analog<br />
Inputs<br />
A/D<br />
DSP Cluster<br />
D/A<br />
Analog<br />
Outputs<br />
Biamp Systems, 10074 S.W. Arctic Drive, Beaverton, Oregon 97005 U.S.A. (503) 641-7287 www.biamp.com<br />
03Dec08