TECHNICAL SPECIFICATIONS - <strong>DUALEX</strong> ® <strong>SCIENTIFIC</strong><br />

Measured material<br />

Measured parameters<br />

Measurement process<br />

Measured area<br />

Sample thickness<br />

Measurement area access<br />

Acquisition time<br />

Storage capacity<br />

Data classification<br />

Flavonoids<br />

Absorbance accuracy (σ) 5%<br />

Repeatability (σ) 2.5%<br />

Reproducibility (σ) 3.5%<br />

Plant leaves<br />

Optical absorbance at a UV wavelength (flavonoid content)<br />

Optical transmittance at 2 near-infrared wavelengths (chlorophyll content)<br />

Main button pressure or clips closing (free choice)<br />

5 mm in diameter<br />

1 mm maximum<br />

8.5 cm maximum (half-leaf width)<br />

< 500 ms<br />

> 10 000 multiparametric measurements<br />

3 levels (file, group and measurement number)<br />

From 0.00 to 3.00 (<strong>DUALEX</strong> ® units, convertible to μg/cm² after calibration)<br />

Chlorophyll<br />

From 0.00 to 150.00 (<strong>DUALEX</strong> ® units, corresponds to μg/cm² of chlorophyll a+b)<br />

Repeatability (σ) 1.3%<br />

Reproducibility (σ) 4.5%<br />

NBI ®<br />

From 0.00 to 999.00 (<strong>DUALEX</strong> ® units)<br />

Temperature range From 5 to 40°C (variation of absorbance < 2%)<br />

Light sources<br />

4 LED: 1 UV-A, 1 Red and 2 Near Infra-Red (NIR)<br />

Detector<br />

1 Silicon Photodiode<br />

User interface<br />

LCD screen<br />

Sound warning<br />

Data downloading<br />

USB connexion for data transfer<br />

Data organisation compatible with any data processing software<br />

Power source<br />

Li-ion rechargeable battery<br />

Autonomy<br />

10 hours<br />

Charging time<br />

4 hours<br />

Total weight<br />

220 g (with battery)<br />

Size<br />

205 mm x 65 mm x 55 mm<br />

Positioning<br />

Internal GPS<br />

Accuracy (pass to pass)<br />

> 1 m<br />

Languages<br />

English, French<br />

Safety<br />

Ring for leash<br />

Updating<br />

Internet online updating<br />

Warning: as FORCE-A is continuously improving its products, technical specifications can be changed without prior notice.<br />

USB Interface<br />

Ring for leach<br />

Keyboard<br />

LCD screen<br />

Cartelat, A., Cerovic, Z.G., Goulas, Y., Meyer, S., Lelarge, C., Prioul, J.-L., Barbottin, A., Jeuffroy, M.-H., Gate, P., Agati, G., Moya, I., 2005. Optically assessed contents of leaf<br />

polyphenolics and chlorophyll as indicators of nitrogen deficiency in wheat (Triticum aestivum L.). Field Crops Res. 91, 35-49.<br />

Cerovic, Z.G., Ounis, A., Cartelat, A., Latouche, G., Goulas, Y., Meyer, S., Moya, I., 2002. The use of, chlorophyll fluorescence excitation spectra for the nondestructive in situ<br />

assessment of UV–absorbing compounds in leaves. Plant Cell Environ. 25, 1663-1676.<br />

Demotes-Mainard, S., Boumaza, R., Meyer, S., Cerovic, Z.G., 2008. Indicators of nitrogen status for ornamental woody plants based on optical measurements of leaf polyphenolics<br />

and chlorophyll contents. Sci. Hort. 115, 377-385.<br />

FORCE-A<br />

Centre Universitaire Paris Sud, Bât. 503<br />

91893 ORSAY Cedex - France<br />

Tel : +33 (0)1 69 35 88 62<br />

Fax : +33 (0)1 69 35 88 97<br />

Opening lever<br />

Optical emitting<br />

head<br />

Optical<br />

detecting head<br />

www.force-a.com<br />

e-mail : info@force-a.fr<br />