400 Watt C-Band Rack Mount High Power Amplifier - Sky-brokers.com
400 Watt C-Band Rack Mount High Power Amplifier - Sky-brokers.com
400 Watt C-Band Rack Mount High Power Amplifier - Sky-brokers.com
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
PRIME POWER<br />
100 to 260 VAC<br />
47 to 63 Hz, Single Phase<br />
1500 VA Maximum, 1<strong>400</strong> VA Typical<br />
0.95 Minimum Prime <strong>Power</strong> Factor<br />
ENVIRONMENT<br />
NONOPERATING TEMPERATURE RANGE<br />
OPERATING TEMPERATURE RANGE<br />
HUMIDITY<br />
ALTITUDE<br />
SHOCK AND VIBRATION<br />
COOLING<br />
-50°C to +70°C<br />
-10°C to +50°C<br />
(2°C/1000 Feet Derating)<br />
Up to 95% Noncondensing<br />
10,000 Feet MSL (maximum)<br />
Normal Transportation<br />
Forced Air<br />
Headquarters<br />
Comtech Xi<strong>com</strong> Technology, Inc.<br />
3550 Bassett Street<br />
Santa Clara, CA 95054<br />
USA<br />
Phone: +1-408-213-3000<br />
Fax: +1-408-213-3001<br />
email: sales@xi<strong>com</strong>tech.<strong>com</strong><br />
Web: www.xi<strong>com</strong>tech.<strong>com</strong><br />
. . . . . . . . . .<br />
INTERFACE<br />
CONTROLS<br />
STATUS<br />
COMPUTER<br />
SERIAL PORT<br />
Type<br />
OPTIONS<br />
• Extended Frequency Coverage<br />
5.85 to 6.725 GHz<br />
6.725 to 7.025 GHz<br />
Function<br />
LOCAL Local/Remote AC <strong>Power</strong> On/OFF<br />
LOCAL AND REMOTE Gain <strong>High</strong> Voltage ON/OFF<br />
Min/Max <strong>Power</strong> Alarm/Fault<br />
Reflected <strong>Power</strong> Alarm/Fault<br />
Fault Reset<br />
Heater Standby ON/OFF<br />
Audio Alarm ON/OFF<br />
Units (<strong>Watt</strong>s, dBm, dBW)<br />
Lamp Test<br />
FRONT PANEL LEDs Standby <strong>Power</strong><br />
FRONT PANEL DIGITAL<br />
DISPLAY<br />
DRY FORM-C RELAY<br />
CONTACTS (2)<br />
HARDWARE INTERFACE<br />
XICOM COMMAND SET<br />
RF SAMPLE PORT<br />
COUPLING<br />
Local<br />
Summary Fault<br />
Heater Time Out (FTD)<br />
<strong>Power</strong> Out<br />
Reflected <strong>Power</strong><br />
TWT Temperature<br />
Heater Hours<br />
Summary Fault<br />
Two Ports: RS-232 & RS-422/RS-485<br />
ASCII Commands<br />
-42 dB Nominal<br />
Remote<br />
<strong>High</strong> Voltage ON/OFF<br />
Heater Standby<br />
Beam Hours<br />
Helix Current<br />
Helix Voltage<br />
Faults:<br />
<strong>High</strong> VSWR<br />
<strong>High</strong> Voltage<br />
Helix Current<br />
TWT Temperature<br />
• 1:1, 1:2, 1:N Redundancy<br />
• Variable Phase Combined<br />
• Integrated Linearizers<br />
Europe Sales Office<br />
Comtech Xi<strong>com</strong> Technology Europe, LTD<br />
4 Portland Business Center<br />
Manor House Lane<br />
Datchet<br />
Berkshire SL3 9EG<br />
United Kingdom<br />
Phone: +011 44 (0) 1753 549 999<br />
Fax: +011 44 (0) 1753 549 997<br />
email: sales@xi<strong>com</strong>europe.<strong>com</strong><br />
Web: www.xi<strong>com</strong>tech.<strong>com</strong><br />
. . . . . . . . . .<br />
Asia Sales Office<br />
Comtech Xi<strong>com</strong> Technology<br />
150 Cecil Street<br />
#08-02<br />
Singapore 069543<br />
Phone: +011 65 6325 1953<br />
Fax: +011 65 6325 1950<br />
email: asiasales@xi<strong>com</strong>tech.<strong>com</strong><br />
Web: www.xi<strong>com</strong>tech.<strong>com</strong><br />
TECHNOLOGY<br />
Document XTRD-<strong>400</strong>C Rev 11, 11/30/2010<br />
© 2010<br />
Note: Technical specifications are subject to change without notice. Please<br />
contact Xi<strong>com</strong> Technology before using this information for system design.