<strong>Model</strong> <strong>AC</strong>-<strong>32</strong><br />

Vertical sealless pump<br />

Specifications<br />

Flow Range<br />

gpm 4 – 460<br />

lpm 15 – 1,514<br />

NPSHR<br />

feet 0.5 – 16<br />

meter 0.15 – 3.67<br />

Differential Head<br />

feet 21 – 625<br />

meter 6.40 – 207<br />

Pump Design Rating<br />

hp 3 – 25<br />

kw 2.24 – 19<br />

Speed Range rpm 1,500 – 7,200<br />

Consult <strong>AC</strong>D engineering for actual performance ratings.<br />

Features & Benefits<br />

• Pump and motor are fully flooded<br />

with liquid, minimizing start-up and<br />

downtime and guaranteeing quick,<br />

responsive pumping<br />

• Sealless design minimizes maintenance<br />

requirements – no mechanical seal<br />

• No sump required – lowers cost<br />

• Sealless zero leakage design is environmentally<br />

safe, releasing no volatile organic<br />

chemicals and contaminates (VOC’s) into<br />

the atmosphere<br />

• Multi-frequency motor provides an efficient<br />

and broad range of operation and power<br />

• Electrical motor and bearing life is extended<br />

being cooled by the cryogen it is pumping,<br />

heat input is minimal and carried off by<br />

discharging liquid<br />

• Low NPSH inducer coupled with a variable<br />

speed soft start motor eliminates cavitation<br />

at pump start-up<br />

• Suitable for Class I, Div I (IEC Zone 0 and 1)<br />

• Pass-thru connection<br />

Applications<br />

• LNG filling station pump<br />

• Fuel loading pump<br />

• LNG peaking plant<br />

Liquids Pumped<br />

• N 2 , Ar, CO 2<br />

• Methane (LNG), Ethylene (C 2 H 2 )


<strong>Model</strong> <strong>AC</strong>-<strong>32</strong><br />

Manufacturing<br />

overall Dimensions: Typical<br />

Pump Performance Curve<br />

Differential Head [feet]<br />

900<br />

800<br />

700<br />

600<br />

500<br />

400<br />

300<br />

200<br />

100<br />

9.38 [238]<br />

Electric Motor<br />

2<br />

1<br />

3<br />

16.88 [430]<br />

.63 [16]<br />

6.0 [152]<br />

2.45<br />

[62]<br />

4.61 [117]<br />

Typical Scope of Supply<br />

• Pump and integral VFD designed<br />

motor with hermetically sealed lead<br />

through shown<br />

• Mounting flanges for mating connections<br />

• Electrical pass-thru connection<br />

4.50 [114]<br />

Discharge:<br />

Mates with 1"–150#<br />

Flat Faced Flange<br />

8.75 [222] 7.50 [191]<br />

Suction:<br />

Mates with 2"–150#<br />

Flat Faced Flange<br />

22.5º<br />

Conduit:<br />

3.75 [95]<br />

3/4" [19] Farside<br />

.63 [16]<br />

.63 [16]<br />

9.9<br />

[251]<br />

3.75 [95]<br />

378 757 1135 1514 1892 2271 2649 3028 3406 3785 4163<br />

0 100 200 300<br />

5<br />

4<br />

Flow Rate [lpm]<br />

6<br />

400 500 600 700 800 900 1000 1100<br />

Flow Rate [gpm]<br />

7<br />

7.6<br />

[193]<br />

7.50 [191]<br />

8.75 [222]<br />

274<br />

244<br />

213<br />

183<br />

152<br />

122<br />

Optional Accessories<br />

• Variable frequency drive<br />

2.65<br />

[67]<br />

• Differential pressure gauge<br />

• Loss of prime detector (cavitation protection)<br />

• Stainless steel safety relief valve<br />

Mouting Hole:<br />

.50 – 13 UNC-2B<br />

One Place<br />

Speed Range:<br />

1: 1 x 2 x 4.5<br />

1,500 to 7,900 rpm<br />

2: 1 x 2 x 6<br />

1,500 to 4,000 rpm<br />

3: 1.5 x 3 x 6<br />

1,500 to 7,350 rpm<br />

4: 2 x 4 x 6<br />

1,500 to 5,720 rpm<br />

5: 2 x 4 x 8.5<br />

1,500 to 5,650 rpm<br />

6: 3 x 5 x 8.5<br />

1,500 to 3,800 rpm<br />

7: 4 x 5 x 10.5<br />

1,500 to 3,500 rpm<br />

• Dual conduit box per NFPA standards for<br />

LNG service<br />

91<br />

61<br />

30<br />

Differential Head [meters]<br />

Discharge Flange<br />

may be rotated in<br />

increments of 45 o<br />

Mouting Holes:<br />

.63Ø 3 Places<br />

inch / [mm]<br />

Specifications subject to change without notice<br />

2<strong>32</strong>1 S. Pullman Street<br />

Santa Ana, CA 92705 USA<br />

Tel 800.525.4216 (USA only)<br />

Tel +1.949.261.7533<br />

Fax +1.949.261.6285<br />

acd@acdcom.com<br />

www.acdcom.com<br />

Global service<br />

North America<br />

Atlanta<br />

Atlanta, Georgia, USA<br />

+1 404.696.8113 • Fax +1 404.696.8116<br />

sales@cryoatlanta.com • cryoindservice.com<br />

California (<strong>AC</strong>D Service)<br />

Santa Ana, California, USA<br />

+1 714.568.0201 • Fax +1 714.641.1921<br />

service@acdcom.com • acdcom.com<br />

Houston<br />

Houston, Texas, USA<br />

+1 281.590.4800 • Fax +1 281.590.4801<br />

sales@cihouston.com • cryoindservice.com<br />

Pittsburgh<br />

Imperial, Pennsylvania, USA<br />

+1 724.695.1910 • Fax +1 724.695.1926<br />

pittcryo@pittcryogenic.com • cryoindservice.com<br />

Red Deer<br />

Red Deer, Alberta, Canada<br />

+1.403.352.4436 • Fax +1.403.352.4439<br />

sales@cryocanada.com • cryoindservice.com<br />

Toronto<br />

Toronto, Ontario, Canada<br />

+1 416.502.1950 • Fax +1 416.502.1952<br />

info@cryocanada.com • cryoindservice.com<br />

International<br />

Australia<br />

Dandenong, Victoria, Australia<br />

+61.3.9791.7888 • Fax +61.3.9769.2788<br />

sales.au@cryoquip.com • cryoquip.com<br />

Brasil<br />

São Paulo - SP, Brasil<br />

Tel/Fax +55.11.2015.4288/4289<br />

acd@cibrazil.com • cryoindservice.com<br />

China<br />

Hangzhou, China<br />

+86.571.8869.0788 • Fax +86.571.8869.0715<br />

hci@mail.hz.zj.cn • cryoindservice.com<br />

Europe (<strong>AC</strong>D CRYO)<br />

CH-4142 Muenchenstein Switzerland<br />

Tel: +41.61.413.0230<br />

Fax: +41.61.413.0233<br />

sales@acdcryo.com • acdcryo.com<br />

D-79415 Bad Bellingen Germany<br />

+49.7635.8105.0 • Fax: +49.7635.8965<br />

info@acdcryo.com • acdcryo.com<br />

Dubai<br />

United Arab Emirates<br />

+1.949.838.7023<br />

acd@acdcom.com • acdcom.com<br />

India<br />

A Division of Rhine Engineering Pvt. Ltd.<br />

Vadodara, Gujarat, India<br />

+91.265.283 0113 • Fax +91.265.283 0112<br />

info@acdcom.com • acdcom.com<br />

Kolkatta, West Bengal, India<br />

+91.973.216 0010<br />

rmukherjee@acdindia.com • acdcom.com<br />

Korea<br />

Yongin-si, Gyeonggi-do, Korea<br />

+82.31.286.6114 • Fax +82.31.286.6118<br />

info@ci-korea.co.kr • cryoindservice.com<br />

Malaysia<br />

Shah Alam, Selangor D.Ehsan, Malaysia<br />

+603.5740.8770 • Fax +603.5740.8775<br />

cryogen@po.jaring.my • cryoindservice.com<br />

Bulletin No. <strong>AC</strong>D <strong>AC</strong><strong>32</strong>-R3.12<br />

© 2012 <strong>AC</strong>D LLC, Printed in USA