02.12.2014 Views

www.texe.com

www.texe.com

www.texe.com

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

1 PHYSICAL<br />

2 ENVIRONMENTAL<br />

3 STANDARDS & APPROVALS<br />

Professional High Immunity PIR<br />

INSTALLATION INSTRUCTIONS<br />

40mm<br />

(1.6”)<br />

Detector Standard: Independently Certified to TS 50131-2-2 Grade 2<br />

Environmental Class II.<br />

System Standard: Suitable for use in a PD 6662/BS EN 50131-1 Grade<br />

2 system. Environmental Class II.<br />

EMC: Independently Certified to EN 50130-4 : 1996<br />

INS 252-4<br />

<strong>www</strong>.<strong>texe</strong>.<strong>com</strong><br />

Ask your distributor today for the Texe<strong>com</strong> full colour Product Guide.<br />

60mm<br />

(2.4”)<br />

112.25mm<br />

(4.4”)<br />

2.5mm (0.1”) ABS<br />

-35°C (-31°F) to +60°C (+140°F)<br />

150g (5oz) approx.<br />

-35°C (-31°F) to +55°C (+131°F)<br />

RF Immunity:<br />

No false alarms from 80MHz to 1GHz at 10V/m.<br />

Complies with BS EN 61000-4-3 : 2002.<br />

Electrostatic Discharge: No false alarms up to 8kV.<br />

Complies with BS EN 61000-4-2 : 1995.<br />

Fast Transient Immunity: No false alarms up to ±4kV.<br />

Complies with BS EN 61000-4-4 : 1995.<br />

High Energy<br />

No false alarms up to ±2kV.<br />

Transient Immunity: Complies with BS EN 61000-4-5 : 1995.<br />

Conducted RF<br />

No false alarms at 10Vrms.<br />

Susceptibility: Complies with BS EN 61000-4-6 : 1996.<br />

Conducted & Radiated Complies with EN 55022 Class B.<br />

Emissions:<br />

Product Identifier: IR<br />

QUALITY ASSURANCE<br />

4<br />

JP1<br />

✗<br />

LED OFF<br />

PULSE COUNT<br />

C e r t i f i c a t e N u m b e r : F M 3 5 2 8 5<br />

Made In England<br />

1<br />

JP1<br />

LED ON<br />

WARRANTY<br />

10 year replacement warranty.<br />

The Prestige IR is designed to detect the movement of an intruder and<br />

activate an alarm control panel. As the Prestige IR is not a <strong>com</strong>plete alarm<br />

system, but only a part thereof, Texe<strong>com</strong> cannot accept responsibility or liability<br />

for any damages whatsoever based on a claim that the Prestige IR failed to<br />

function correctly.<br />

Due to our policy of continuous improvement Texe<strong>com</strong> reserves the right to change<br />

specification without prior notice. All specifications are measured at 20ºC (68ºF).<br />

© 2003-2006 Texe<strong>com</strong> Ltd. Document Ref: PIR/EU/1.0-4<br />

The Prestige IR is protected by UK & International Registered Designs. Registered Design No’s: 3004997, 3004260,<br />

3004261 & 3008616. Prestige, CloakWise and PetWise are Trademarks of Texe<strong>com</strong> Ltd.<br />

DO NOT TOUCH<br />

✗<br />

EOL Resistor<br />

See Section 14<br />

2<br />

3<br />

0.3 - 3.0m/s<br />

1 - 10ft/s<br />

5 COVERAGE AND PICK-UP<br />

6 ANGLING THE DETECTOR<br />

7 MOUNTING HEIGHT AND<br />

SETTINGS<br />

8<br />

ALTERING COVERAGE AT 2m<br />

MOUNTING HEIGHT<br />

15m<br />

50’<br />

✓<br />

90º<br />

2m<br />

6'7"<br />

✓<br />

15m 50'<br />

2.5m/8’2”<br />

3.0m/9’10”<br />

2.0m/6’7”<br />

2m<br />

6'7"<br />

2m<br />

6'7"<br />

2m<br />

6'7"<br />

8m<br />

26'2"<br />

10m<br />

32'9"<br />

2m<br />

6'7"<br />

1.5m/4’11”<br />

2m<br />

6'7"<br />

15m<br />

50'<br />

15m<br />

50’<br />

4m<br />

13'1"<br />

15m<br />

50'


9 COVERAGE PATTERN<br />

Volumetric<br />

10 MOUNTING THE PRESTIGE IR<br />

For indoor use only<br />

11 MOUNTING THE PRESTIGE IR<br />

Mount on a stable surface<br />

12 WIRING<br />

Do not run cable parallel to mains wiring<br />

✗<br />

✓<br />

✗<br />

✓<br />

✓<br />

✓<br />

230V<br />

110V<br />

✗<br />

230V<br />

110V<br />

See Mounting Height Diagram (Section 7)<br />

13 CHOOSING A LOCATION<br />

Avoid <strong>com</strong>mon false alarm sources<br />

✗<br />

✗<br />

✗<br />

✗<br />

14 EOL RESISTOR JUMPER LINKS<br />

The jumper links JP3 and JP4 (see Section 4) are used to select resistances for<br />

End-of-Line (EOL) wiring applications.<br />

JP3 Selects the End-of-Line<br />

resistance. Equivalent to wiring<br />

a resistor of the selected value<br />

as shown.<br />

JP4 Selects the resistance<br />

across the alarm relay.<br />

Equivalent to wiring a resistor<br />

of the selected value as shown.<br />

EXAMPLES OF EOL JUMPER LINK USE<br />

TAMPER - JP3<br />

ALARM - JP4<br />

15 DETECTOR KNOCKOUTS<br />

✗<br />

✗<br />

✗<br />

✗<br />

If EOL wiring is not used, the headers should be left in the default (O/C) position.<br />

If the required resistance values are not available, leave the headers in the O/C position<br />

and wire in external resistors as normal.<br />

EOL Settings for Texe<strong>com</strong> Panels JP3 JP4<br />

Premier & Premier International 2k2 4k7Cexample<br />

Double Pole<br />

(jumper links not used)<br />

Dual End-of-Line<br />

(DEOL)<br />

16 CEILING MOUNT BRACKET<br />

1 2 3<br />

4<br />

✗<br />

5 8<br />

17 WALL MOUNT BRACKET<br />

6<br />

Seal all holes<br />

7<br />

✓<br />

1 2<br />

3 4 5<br />

INS 252-4