AIR FILTER <strong>MEDIA</strong><br />

<strong>FILTRAIR</strong> <strong>G3</strong> <strong>HVAC</strong> <strong>MEDIA</strong><br />

• Pre and Coarse Filtration Barrier to the air<br />

intake systems in general ventilation and air<br />

handling systems<br />

• UL Class 1 and self extinguishing according<br />

DIN 53438-F1<br />

• 100% Synthetic<br />

DESCRIPTION<br />

<strong>Filtrair</strong> <strong>G3</strong> <strong>HVAC</strong> media VNF-290 and PSF-200 are designed<br />

for coarse filtration of the air intake in general ventilation and air<br />

handling systems installed in public buildings, offices, factories<br />

and equipment of all kinds. The products are suited for high air<br />

volume applications which are heavily contaminated.<br />

The <strong>Filtrair</strong> <strong>G3</strong> <strong>HVAC</strong> media combine a high dust holding capacity<br />

with a low pressure drop and are therefore extremely cost<br />

effective with a long filter life.<br />

Synthetic fiber-based filter media developed and produced at<br />

<strong>Filtrair</strong> high-tech media plant based in The Netherlands. The<br />

filter media are constructed from selected high performance,<br />

non-breakable fibers in a progressive density multi-layering<br />

technique to ensure high depth loading with optimal lowest<br />

pressure drop performance, to achieve gravimetric arrestance<br />

in accordance with EN 779:2012 standard ratings.<br />

FLAMMABILITY RATINGS<br />

<strong>Filtrair</strong> VNF-290/PSF-200 conform to German fire classification<br />

standards (DIN 53438-F1) and are self-extinguishing. They<br />

are resistant to evaporated solvents and are produced in a<br />

100% silicone-free environment.<br />

FEATURES AND BENEFITS<br />

<strong>Filtrair</strong> VNF-290/PSF-200 are specially designed to be used in<br />

• GENERAL AIR HANDLING UNITS<br />

• AIR CONDITIONING SYSTEMS<br />

• VENTILATION SYSTEMS OF ALL KINDS<br />

• AIR INTAKE PRE-FILTRATION BANKS<br />

• HOUSE HOLD APPLICATIONS<br />

• RAILROAD CAR VENTILATION<br />

• INTAKE AND EXHAUST AIR SYSTEMS FOR HEAVY INDUS-<br />

TRY AND CHEMICAL PLANTS<br />

SPECIALTY PRODUCTS<br />

<strong>Filtrair</strong> can offer other <strong>G3</strong> specialty products upon request.<br />

These products will cover fire rating standards according<br />

NF-P92-503/504, wash ability requirements and any other<br />

special purpose. Technical data are available upon request.<br />

VNF-290 and PSF-200 are thermally bonded to prevent fiber<br />

release. The clean air sides can be imprinted for easy identification<br />

to ensure the correct installation in pad, roll or pocket<br />

format.<br />

PSF-200 requires minimum order quantities<br />

Member of Filtration Group ®


PERFORMANCE DATA<br />

Product VNF-290 PSF-200<br />

Rated Air Flow (m 3 /h/m 2 ) 5.400 5.400<br />

Rated Air Flow Velocity 1,5 m/sec 1,5 m/sec<br />

Initial Resistance 35 Pa 38 Pa<br />

Final Resistance 250 Pa 250 Pa<br />

Average Arrestance 86% 82%<br />

Dust holding capacity 620 g/m 2 550 g/m 2<br />

Filter Class acc. EN 779:2012 <strong>G3</strong> <strong>G3</strong><br />

APPLICATION PARAMETERS<br />

Product VNF-290 PSF-200<br />

Temperature Resistance Up to 100 o C Up to 100 o C<br />

Temp. short peaks Up to 120 o C Up to 120 o C<br />

Nominal thickness 20 mm +/- 3 20 mm +/- 3<br />

Relative humidity 100% 100%<br />

Roll sizes standard 2 m x 20 m 2 m x 20 m<br />

1 m x 20 m 1 m x 20 m<br />

Regenerable / washable yes yes<br />

PRESSURE DROP VS AIR FLOW RATE<br />

VNF-290/PSF-200<br />

PRESSURE DROP (Pa)<br />

ARRESTANCE (%)<br />

50<br />

45<br />

40<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

100<br />

90<br />

80<br />

70<br />

60<br />

50<br />

40<br />

30<br />

20<br />

VNF-290 / PSF-200<br />

PRESSURE DROP vs AIR FLOW RATE<br />

V NF-290<br />

PSF-200<br />

0 1.500 3.000 4.500 6.000 7.500<br />

AIR FLOW RATE (m³/h)<br />

VNF-290<br />

DUST LOADING vs ARRESTANCE VS PRESSURE DROP<br />

500<br />

450<br />

400<br />

350<br />

300<br />

250<br />

200<br />

150<br />

100<br />

PRESSURE DROP (Pa)<br />

PRESSURE DROP DROP (Pa) (Pa)<br />

ARRESTANCE (%) (%)<br />

ARRESTANCE (%) (%)<br />

45<br />

45<br />

40<br />

40<br />

35<br />

35<br />

30<br />

30<br />

25<br />

25<br />

20<br />

20<br />

15<br />

15<br />

10<br />

10<br />

5<br />

V NF-290 PSF-200<br />

5<br />

0<br />

V NF-290 PSF-200<br />

0 0 1.500 3.000 4.500 6.000 7.500<br />

0 1.500 3.000 4.500 6.000 7.500<br />

AIR FLOW RATE (m³/h)<br />

AIR FLOW RATE (m³/h)<br />

VNF-290<br />

DUST LOADING vs ARRESTANCE<br />

VNF-290<br />

vs PRESSURE DROP<br />

DUST VNF-290 LOADING vs ARRESTANCE VS PRESSURE DROP<br />

DUST LOADING vs ARRESTANCE VS PRESSURE DROP<br />

100<br />

500<br />

100<br />

90<br />

500<br />

450<br />

90<br />

80<br />

450<br />

400<br />

80 70<br />

400 350<br />

70<br />

60<br />

350<br />

300<br />

60<br />

50<br />

300<br />

250<br />

50<br />

40<br />

250<br />

200<br />

40<br />

30<br />

200<br />

150<br />

30 20<br />

150 100<br />

20<br />

10<br />

100<br />

50<br />

Arrestance<br />

Pressure drop<br />

10<br />

0<br />

Arrestance<br />

Pressure drop<br />

50<br />

0<br />

0 0 100 200 300 400 500 600 700 8000<br />

0 100 200 300 400 500 600<br />

DUST LOADING (g/m 2 )<br />

700 800<br />

DUST LOADING (g/m 2 )<br />

DUST LOADING vs ARRESTANCE<br />

PSF-200<br />

vs PRESSURE DROP<br />

PSF-200 PSF-200<br />

DUST LOADING vs ARRESTANCE VS PRESSURE DROP<br />

DUST LOADING vs ARRESTANCE VS PRESSURE DROP<br />

100<br />

500<br />

100<br />

90<br />

500<br />

450<br />

90<br />

80<br />

450<br />

400<br />

80 70<br />

400 350<br />

70<br />

60<br />

350<br />

300<br />

60<br />

50<br />

300<br />

250<br />

50<br />

40<br />

250<br />

200<br />

40<br />

30<br />

200<br />

150<br />

30 20<br />

150 100<br />

20<br />

10<br />

100<br />

50<br />

Arrestance<br />

Pressure drop<br />

10<br />

0<br />

Arrestance<br />

Pressure drop<br />

50<br />

0<br />

0 0 100 200 300 400 500 600 700 8000<br />

0 100 200 300 400 500 600<br />

DUST LOADING (g/m 2 )<br />

700 800<br />

DUST LOADING (g/m 2 )<br />

<strong>Filtrair</strong> B.V.<br />

De Werf 16<br />

8447 GE Heerenveen<br />

PO Box 611<br />

8440 AP Heerenveen<br />

The Netherlands<br />

P. +31 (0) 513-626 355<br />

F. +31 (0) 513-627 306<br />

E. marketing@filtrair.com<br />

www.filtrair.com<br />

10<br />

50<br />

Arrestance<br />

Pressure drop<br />

VNF-290-PSF-200-124001061-V1<br />

0<br />

0<br />

0 100 200 300 400 500 600 700 800<br />

All data are average indicative values with usual manufacturing and testing tolerances. We reserve the right to modify performance data without prior notice.<br />

Specific performance data DUST will require LOADING our written (g/mconfirmation.<br />

2 )<br />

<strong>Filtrair</strong> ® is the registered trade mark of <strong>Filtrair</strong> bv. Member of Filtration Group ®<br />

PRESSURE DROP DROP (Pa) (Pa)<br />

PRESSURE DROP DROP (Pa) (Pa)