<strong>Step</strong> <strong>by</strong> <strong>Step</strong><br />

<strong>Street</strong> <strong><strong>Light</strong>ing</strong> <strong>Simulation</strong><br />

<strong>with</strong> OSRAM <strong>LED</strong>s in DIALux


Agenda<br />

Page<br />

• Introduction and Install of DIALux<br />

• Import IES files of OSRAM <strong>LED</strong>s<br />

• Quick <strong>Street</strong> Planning Wizard <strong>with</strong> DIALux<br />

• <strong>Step</strong> <strong>by</strong> <strong>Step</strong> – Design <strong>with</strong> OSRAM <strong>LED</strong>s in DIALux<br />

3<br />

8<br />

12<br />

20<br />

Event / Title | December 17, 2008 | Page 2<br />

SSL | Application Design Center Asia | V.Chen


What is special about DIALux<br />

• DIALux - a planning software <strong>for</strong> <strong>you</strong>r project presentation.<br />

• Calculation: latest radiosity procedures, fast and always correct.<br />

• Results: Results can be printed out or transmitted as a pdf file. Each<br />

view and each rendering can be saved as a .jpg file.<br />

• Interactive 3-D visualization: Simply move around the room.<br />

• Visualization: Use of textures and furniture <strong>for</strong> realistic rendering.<br />

• Photo realism: <strong>with</strong> integrated raytracing module.<br />

• False colours: False colours provide quantitative analysis of<br />

complex geometries at a glance.<br />

• Movies: Walk through the photo realistic visualization of <strong>you</strong>r light<br />

planning and send the film to <strong>you</strong>r customer via email.<br />

• Interaction: Import and export: .dwg and .dxf files can be imported<br />

and exported <strong>with</strong> results after completion of the planning process.<br />

• DIALux <strong>Light</strong>: Easy to use, step-<strong>by</strong>-step lighting design.<br />

Event / Title | December 17, 2008 | Page 3<br />

SSL | Application Design Center Asia | V.Chen


Free Download DIALux from website<br />

• Download the DIALux Setup (version DIALux 4.5.0.1 ) from homepage (www.DIAL.de or<br />

www.dialux.com) on <strong>you</strong>r hard-disk.<br />

• Language available<br />

www.DIAL.de or www.dialux.com<br />

– deutsch<br />

– english<br />

– français<br />

– italiano<br />

– español<br />

– 中 文<br />

• Download file size:<br />

about 250MB<br />

Event / Title | December 17, 2008 | Page 4<br />

SSL | Application Design Center Asia | V.Chen


Online Update<br />

• If <strong>you</strong> have already installed old version of DIALux, <strong>you</strong> could use “ online update” to<br />

newest version.<br />

• In DIALux <strong>you</strong> will find a new menu named “Online”.<br />

• After selecting “Online Update…” DIALux automatically checks <strong>for</strong> newer versions of the<br />

software and <strong>for</strong> new online PlugIns.<br />

• But it will take some time to finish update.<br />

Event / Title | December 17, 2008 | Page 5<br />

SSL | Application Design Center Asia | V.Chen


The DIALux User Interface<br />

• These three work areas enable effective and clearly arranged planning of lighting<br />

installation <strong>with</strong> DIALux.<br />

CAD-Window<br />

Task Pane<br />

Project manager<br />

<strong>with</strong> Inspector<br />

Event / Title | December 17, 2008 | Page 6<br />

SSL | Application Design Center Asia | V.Chen


Agenda<br />

Page<br />

• Introduction and Install of DIALux<br />

• Import IES files of OSRAM <strong>LED</strong>s<br />

• Quick <strong>Street</strong> Planning Wizard <strong>with</strong> DIALux<br />

• <strong>Step</strong> <strong>by</strong> <strong>Step</strong> – Design <strong>with</strong> OSRAM <strong>LED</strong>s in DIALux<br />

3<br />

8<br />

12<br />

20<br />

Event / Title | December 17, 2008 | Page 7<br />

SSL | Application Design Center Asia | V.Chen


.IES or .Idt files<br />

• .IES or .Idt file describe the<br />

in<strong>for</strong>mation of light distribution,<br />

luminous flux, and power.<br />

• .IES or .Idt file are very small<br />

( only about 10K) compared to<br />

ray data (about 200M).<br />

• OSRAM OS provide both .IES<br />

(or .Idt) file and ray data of our<br />

<strong>LED</strong> products on website.<br />

Event / Title | December 17, 2008 | Page 8<br />

SSL | Application Design Center Asia | V.Chen


Download .IES file of OSRAM <strong>LED</strong> from website<br />

• http://www.ledlight<strong>for</strong><strong>you</strong>.com<br />

• Tools & Downloads >> Optical Tools<br />

Event / Title | December 17, 2008 | Page 9<br />

SSL | Application Design Center Asia | V.Chen


Import .IES file to DIALux<br />

Event / Title | December 17, 2008 | Page 10<br />

SSL | Application Design Center Asia | V.Chen


Agenda<br />

Page<br />

• Introduction and Install of DIALux<br />

• Import IES files of OSRAM <strong>LED</strong>s<br />

• Quick <strong>Street</strong> Planning Wizard <strong>with</strong> DIALux<br />

• <strong>Step</strong> <strong>by</strong> <strong>Step</strong> – Design <strong>with</strong> OSRAM <strong>LED</strong>s in DIALux<br />

3<br />

8<br />

12<br />

20<br />

Event / Title | December 17, 2008 | Page 11<br />

SSL | Application Design Center Asia | V.Chen


Quick <strong>Street</strong> Planning Wizard<br />

This wizard guides <strong>you</strong> through the quick planning <strong>for</strong> streets.<br />

• <strong>you</strong> will find the wizards in<br />

the menu File >> Wizard<br />

Event / Title | December 17, 2008 | Page 12<br />

SSL | Application Design Center Asia | V.Chen


<strong>Street</strong> profile and illumination class<br />

• <strong>Street</strong> profile<br />

• <strong>Street</strong> name and maintenance factor are likewise inserted on this page.<br />

• In the following window <strong>you</strong> can fix the individual or combined valuation<br />

fields <strong>for</strong> the street. In order to define photometric requirements <strong>for</strong> the<br />

street, select an illumination class <strong>for</strong> every valuation field.<br />

Event / Title | December 17, 2008 | Page 13<br />

SSL | Application Design Center Asia | V.Chen


Luminaire arrangement<br />

• In the window Luminaire arrangement <strong>you</strong> can select a luminaire and place this<br />

in an arrangement. (You need to import the IES file of OSRAM <strong>LED</strong>s first,<br />

otherwise <strong>you</strong> can only select the existing traditional luminaire in DIALux)<br />

• You can optimize the arrangement parameters depending on the predefined<br />

photometric requirements.<br />

Event / Title | December 17, 2008 | Page 14<br />

SSL | Application Design Center Asia | V.Chen


Start Calculation<br />

• Afterwards a final dialogue will appear automatically. If <strong>you</strong> activate the checkbox, the generated<br />

street will be calculated immediately.<br />

• Click on the Finish button and <strong>you</strong>r street project will be displayed.<br />

Event / Title | December 17, 2008 | Page 15<br />

SSL | Application Design Center Asia | V.Chen


Rotate 3D View<br />

Rotate 3D View; left-click and move the mouse<br />

while holding the mouse button pressed.<br />

Event / Title | December 17, 2008 | Page 16<br />

SSL | Application Design Center Asia | V.Chen


3D light distribution Display<br />

Help Rays <strong>for</strong> Luminaires / 3D light distribution Display / Show false colors in CAD<br />

Event / Title | December 17, 2008 | Page 17<br />

SSL | Application Design Center Asia | V.Chen


Show false colors in CAD<br />

• Display the 3D rendering in a false colour<br />

rendering<br />

• Easy to check the illuminance uni<strong>for</strong>mity<br />

• Freely scaleable value ranges and definable<br />

colour gradients<br />

Event / Title | December 17, 2008 | Page 18<br />

SSL | Application Design Center Asia | V.Chen


Agenda<br />

Page<br />

• Introduction and Install of DIALux<br />

• Import IES files of OSRAM <strong>LED</strong>s<br />

• Quick <strong>Street</strong> Planning Wizard <strong>with</strong> DIALux<br />

• <strong>Step</strong> <strong>by</strong> <strong>Step</strong> – Design <strong>with</strong> OSRAM <strong>LED</strong>s in DIALux<br />

3<br />

8<br />

12<br />

20<br />

Event / Title | December 17, 2008 | Page 19<br />

SSL | Application Design Center Asia | V.Chen


<strong>Step</strong> 1: Collecting road in<strong>for</strong>mation<br />

<strong>Street</strong> profile, width, N of lanes, coating…<br />

In<strong>for</strong>mation list be<strong>for</strong>e design:<br />

1. <strong>Street</strong> location and photos<br />

2. Width of street<br />

3. N of lanes<br />

4. Coating material<br />

5. Existing mounting height or pole distance<br />

Decide the road classification and required E av<br />

and U o<br />

according to street lighting standards<br />

In<strong>for</strong>mation needed <strong>for</strong> lighting simulation<br />

Event / Title | December 17, 2008 | Page 20<br />

SSL | Application Design Center Asia | V.Chen


<strong>Step</strong> 2: Edit street in DIALux<br />

Arrangement of street component according<br />

to the road in<strong>for</strong>mation.<br />

Event / Title | December 17, 2008 | Page 21<br />

SSL | Application Design Center Asia | V.Chen


<strong>Step</strong> 3: Decide which <strong>LED</strong> (color bin and brightness group)<br />

• CCT: from 5000K-6500K (LW, LUW)<br />

• If need CCT from 4000K-5000K, can be mixed <strong>by</strong> LUW and LY.<br />

Golden DRAGON<br />

<strong>with</strong> Oval Lens<br />

Golden DRAGON Plus<br />

No need of secondary<br />

optical design<br />

Need lens or reflector<br />

Higher brightness<br />

Event / Title | December 17, 2008 | Page 22<br />

SSL | Application Design Center Asia | V.Chen


<strong>Step</strong> 4: Change luminous flux<br />

You can change the luminous flux and power here.<br />

It’s related to how many <strong>LED</strong>s in one lamp.<br />

Event / Title | December 17, 2008 | Page 23<br />

SSL | Application Design Center Asia | V.Chen


<strong>Step</strong> 5: luminaire arrangement<br />

Normal methods of<br />

luminaire arrangement<br />

<strong><strong>Light</strong>ing</strong> Class<br />

Single row<br />

Double row,<br />

<strong>with</strong> offset<br />

Double row,<br />

opposing<br />

• Single row<br />

• Double row, opposing<br />

• Double row, <strong>with</strong> offset<br />

Road in<strong>for</strong>mation<br />

Uni<strong>for</strong>mity<br />

W ≤ 6m<br />

N ≤2<br />

0.4~0.5<br />

W ≥ 8m<br />

N ≥2<br />

0.5~0.8<br />

W ≥ 16m<br />

N ≥4<br />

0.5~0.8<br />

! Rules<br />

of<br />

thumb<br />

Luminaire arrangement<br />

will be decided based on<br />

• street profile<br />

• requirements<br />

Figure<br />

• For LUW W5JM, Double<br />

row, opposing was<br />

recommended.<br />

Event / Title | December 17, 2008 | Page 24<br />

SSL | Application Design Center Asia | V.Chen


<strong>Step</strong> 6: Optimize arrangement parameters<br />

Optimize arrangement parameters<br />

• (1) Mounting Height: 6m~10m<br />

• (2) Overhang: 1m~2m<br />

• (3) Boom Angle: 10°~15°<br />

• (4) Boom Length: 1m~3m<br />

• (5) Pole Distance<br />

Boom Angle<br />

Mounting Height<br />

Boom Length<br />

• These parameter will be optimized<br />

according to street profile to achieve<br />

best per<strong>for</strong>mance: E av and U o .<br />

• If a certain Uo was required, the most<br />

economic mounting height and pole<br />

distance could be optimized.<br />

• Lower distance, longer pole distance<br />

could save energy and pole cost.<br />

Overhang<br />

(5)Pole Distance<br />

Lamp<br />

Event / Title | December 17, 2008 | Page 25<br />

SSL | Application Design Center Asia | V.Chen


<strong>Step</strong> 7: calculation and simulation<br />

E av<br />

(lx)<br />

17<br />

E min<br />

(lx)<br />

8.6<br />

E max<br />

(lx)<br />

24<br />

Uo<br />

0.52<br />

E min<br />

/E max<br />

0.36<br />

Change to double row, offset<br />

Double row, opposing<br />

2<br />

Not so uni<strong>for</strong>m,<br />

need to be improved<br />

1<br />

Optimized results<br />

3<br />

E av<br />

(lx)<br />

19<br />

E min<br />

(lx)<br />

16<br />

E max<br />

(lx)<br />

22<br />

Uo<br />

0.83<br />

E min<br />

/E max<br />

0.72<br />

Event / Title | December 17, 2008 | Page 26<br />

SSL | Application Design Center Asia | V.Chen


<strong>Step</strong> 8: Save the selected output as PDF file<br />

Event / Title | December 17, 2008 | Page 27<br />

SSL | Application Design Center Asia | V.Chen


<strong>Step</strong> 9: output design plan<br />

Luminaire arrangement<br />

Event / Title | December 17, 2008 | Page 28<br />

SSL | Application Design Center Asia | V.Chen


<strong>Step</strong> 10: output simulation results<br />

Isolines (E)<br />

Table (E)<br />

E av (lx)<br />

19<br />

E min (lx)<br />

16<br />

E max (lx)<br />

22<br />

Uo<br />

0.83<br />

E min /E max<br />

0.72<br />

Main results<br />

Event / Title | December 17, 2008 | Page 29<br />

SSL | Application Design Center Asia | V.Chen


Thank <strong>you</strong> <strong>for</strong> <strong>you</strong>r attention.