EXAMPLE: Assume a DIVIDE number of 41.<br />

That is 1 ONES. Program switch positions 1 thru 4 next to the 1 in the ONES DIVIDE NUMBER column.<br />

That is also 40 TENS. Program switch positions 5 thru 8 next to the 40 in the TENS DIVIDE NUMBER column.<br />

PROGRAM CHART FILTER PROGRAM CHART<br />

Ones Tens Full<br />

Divide Switch Positions Divide Switch Positions Scale<br />

Switch Positions<br />

Number Number Frequency<br />

1 2 3 4 5 6 7 8 9 10 11 12<br />

1 ON OFF OFF OFF 10 ON OFF OFF OFF < 347 ON OFF OFF OFF<br />

2 OFF ON OFF OFF 20 OFF ON OFF OFF 347-388 ON OFF OFF ON<br />

3 ON ON OFF OFF 30 ON ON OFF OFF 389-546 ON OFF ON ON<br />

4 OFF OFF ON OFF 40 OFF OFF ON OFF 547-695 OFF OFF OFF OFF<br />

5 ON OFF ON OFF 50 ON OFF ON OFF 696-748 OFF OFF OFF ON<br />

6 OFF ON ON OFF 60 OFF ON ON OFF 749-808 OFF OFF ON OFF<br />

7 ON ON ON OFF 70 ON ON ON OFF 809-905 OFF OFF ON ON<br />

8 OFF OFF OFF ON 80 OFF OFF OFF ON 906-1072 ON ON ON OFF<br />

9 ON OFF OFF ON 90 ON OFF OFF ON 1073-1286 ON ON ON ON<br />

1287-1497 OFF ON OFF OFF<br />

1498-1771 OFF ON OFF ON<br />

1772-2145 OFF ON ON OFF<br />

> 2145 OFF ON ON ON<br />

Correction formula for <strong>programmable</strong> <strong>speedometers</strong><br />

To change or correct an existing speedometer reading to a different reading, the Program Divide Number<br />

is changed, using Switches 1 through 8 (See Figure above).<br />

Incorrect speed reading (MPH or Km/H) x Program Divide Number<br />

Divided by Actual Speed<br />

= Correct DIVIDE number.<br />

Example:<br />

If the speedometer reads 45 MPH at 55 MPH actual speed, and the switches are set for a Program Divide # of 65:<br />

45 x 65 = 53.18, rounded off to 53<br />

55<br />

In this case, the switch configuration changes from Program DIVIDE # of 65 (101001100101) to Program DIVIDE<br />

# of 53 (110010101111) where 0 = OFF, 1=ON.<br />

Filter switches 9-12 are listed in the chart above. Determine Full Scale Frequency with the new settings by multiplying the<br />

new Divide # x Constant 23.61.<br />

In the above example, 53 x 23.61 = 1,251.33. If Necessary, reset switches 9-12 to reflect the correct new<br />

Full Scale Frequency.<br />