Tvrda gas-propusna (RGP) kontaktna sočiva Koncepcija
Tvrda gas-propusna (RGP) kontaktna sočiva Koncepcija
Tvrda gas-propusna (RGP) kontaktna sočiva Koncepcija
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Slide 18<br />
Dizajn zadnje površine:<br />
Cliničko razmatranje<br />
• Centralni model fluoresceinom<br />
• Promene u krivini kornee<br />
• Viđenje<br />
Rigid Gas Permeable Contact Lenses Design<br />
Back Surface Design: Clinical Considerations<br />
Central fluorescein pattern.<br />
The use of sodium fluorescein is a sensitive technique for comparing the cornea’s shape<br />
to that of a trial contact lens by highlighting the differences between them.<br />
Corneal curvature changes.<br />
When a fitting relationship other than alignment is chosen, the possibility that the lens<br />
may alter the corneal curvature and/or shape needs to be considered.<br />
Lens adherence.<br />
Virtually all EW <strong>RGP</strong> wearers will show an episode of lens adherence at some time and it<br />
is still not clear what, if anything, can be done to eliminate the occurrence.<br />
Vision.<br />
If the corneal shape is normal and regular, the tear lens power, and its influence on the<br />
final BVP required, is directly influenced by the BOZR chosen. If the cornea is irregular,<br />
keratoconic or highly astigmatic, the overall back surface shape, as well as the BOZR,<br />
may influence the vision outcome.<br />
Dizajn zadnje površine:<br />
Cliničko razmatranje<br />
Centralni model fluoresceinom.<br />
Korišćenje natrijumovog fluoresceina je osetljiva tehnika za poređenje oblika kornee sa<br />
oblikom probnog <strong>sočiva</strong> tako što su oblasti gde postoje razlike svetlije.<br />
Promene u krivini kornee<br />
Kada se izabere neki drugi način fitovanja od potpuno podešenog, postoji mogućnost ta<br />
sočivo menja krivinu kornee.