30.12.2014 Views

Condenser exploder TZK-350N - Kopex Electric Systems

Condenser exploder TZK-350N - Kopex Electric Systems

Condenser exploder TZK-350N - Kopex Electric Systems

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Condenser</strong> <strong>exploder</strong><br />

<strong>TZK</strong>-<strong>350N</strong><br />

<strong>Kopex</strong> <strong>Electric</strong> <strong>Systems</strong> S.A.<br />

ul. Biskupa Burschego 3, 43 - 100 Tychy<br />

tel.: 00 48 32 249 94 80<br />

fax: 00 48 32 241 34 57<br />

serwis: 00 48 601 462 818<br />

e-mail: poczta@kessa.com.pl<br />

www.kessa.com.pl


CHARACTERISTIC<br />

FEATURES<br />

The <strong>TZK</strong>-<strong>350N</strong> condenser <strong>exploder</strong> is assigned for<br />

starting of electric igniters 0.2 A, 0.45 A & 2 A connected<br />

in series, in parallel, in series & parallel or triring<br />

system, in the ore or mineral mines, quarries, etc.<br />

in the non-methane fields, within the explosion-free<br />

zones. The tester may be used inside excavations<br />

(rooms) of hard coal mining factories in the fields with<br />

the „a”, „b” & „c” methane explosion hazard category<br />

or the „A”, „B” coal dust explosion hazard class.<br />

TECHNICAL DATA<br />

Shot condenser charging voltage<br />

STRUCTURE<br />

The <strong>TZK</strong>-<strong>350N</strong> <strong>exploder</strong> has a fully plastic hermetic<br />

casing having the IP 67 casing protection grade.<br />

FUNCTIONAL<br />

DESCRIPTION<br />

The <strong>TZK</strong>-<strong>350N</strong> <strong>exploder</strong>’s power source is the accumulator<br />

battery from which, after switching of the shot<br />

connector the converter charging the shot condenser<br />

is supplied.<br />

After 15 ÷ 30 s the shot condenser is charged and<br />

<strong>exploder</strong> is ready to send a shot impulse to the shot<br />

circuit. The exploding readiness is signalized by lighting<br />

of a red electroluminescent diode. Turning the shot<br />

key into “S” position causes a shot and switching-off<br />

the <strong>exploder</strong>’s supply.<br />

670 ÷ 700 V<br />

Shot condenser capacity 400 μF +25%<br />

Shot impulse duration<br />

Shooting readiness time<br />

Supply<br />

Accumulator charging current<br />

Accumulator charging time<br />

Signalization<br />

Signalization<br />

4 ms<br />

≤30 s<br />

4 accumulators 1,2 V / 3,5 ÷ 5 Ah<br />

400 mA<br />

14 h<br />

shooting readiness – red diode<br />

accumulators are charged – green diode<br />

Working temperature range -10 ºC ÷ 40 ºC<br />

Technical Opinion of KDB „Barbara” No. 13/07<br />

Dimensions<br />

Weight<br />

φ160x255mm<br />

3,5kg<br />

ACCORDANCE WITH<br />

STANDARDS<br />

DEVICE MARK<br />

KDB 07 EXP D-33<br />

The <strong>exploder</strong> meets requirements of the PN-EN 13763-<br />

26 standard: „Explosives for civil use. Exploders & relays.<br />

Part 26: Definitions, testing methods and requirements<br />

for devices and accessories necessary for reliable<br />

and safe functioning of <strong>exploder</strong>s and relays” The <strong>TZK</strong>-<br />

<strong>350N</strong> <strong>exploder</strong> meets requirements relating to electromagnetic<br />

compatibility and resistance for interferences<br />

described in the Annex A of a/m standard.<br />

www.kessa.com.pl<br />

e-mail: poczta@kessa.com.pl<br />

<strong>Kopex</strong> <strong>Electric</strong> <strong>Systems</strong> S.A.<br />

ul. Biskupa Burschego 3, 43 -100 Tychy<br />

tel.: 00 48 32 249 94 80<br />

fax: 00 48 32 241 34 57<br />

serwis: 00 48 601 462 818

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!