Single Axis NC Controllers<br />

TPC CONTROLLER INSTALLATION<br />

To be prepared by <strong>the</strong> customer:<br />

u Air supply<br />

v M signal<br />

w Power supply<br />

x Stand (optional)<br />

u Air supply<br />

Coupling Air Hose Coupling<br />

1/4” NPT<br />

Regulator/Filter<br />

Air supply<br />

All rotary tables use a pneumatic or air-hydraulic clamping<br />

<strong>system</strong>, so an air supply with <strong>the</strong> following items is required.<br />

• Air filter and regulator suitable for 72 psi.<br />

• Air hose<br />

• 1/4” NPT fitting for <strong>the</strong> rotary table<br />

v M signal<br />

The figure TPC-Jr shows <strong>the</strong> controller example for example <strong>the</strong> TPC-Jr controller.<br />

w Power supply<br />

When a machining center controls <strong>the</strong> rotary table, <strong>the</strong><br />

command is normally made by M signal. All machine tool<br />

M signal cables must be connected to a terminal block in <strong>the</strong><br />

machine tool control cabinet. For connection with an interlocking<br />

cable, see <strong>the</strong> examples shown on pages 60 and 61.<br />

The TPC-Jr controller is supplied with a NEMA L6-20P plug<br />

(20 amp, 1 phase, 250V). The TPC3 controller is supplied with<br />

a NEMA L15-20P plug (20 amp, 3 phase, 250 V).<br />

If connectors o<strong>the</strong>r than <strong>the</strong> above are used, <strong>the</strong>y are to be<br />

supplied by <strong>the</strong> customer. For <strong>the</strong> power requirements of TPC<br />

controllers, refer to <strong>the</strong> TPC specifications page.<br />

The TPC controller should be connected to <strong>the</strong> machine tool<br />

emergency stop circuit. If <strong>the</strong> available power supply voltage is<br />

different from <strong>the</strong> required voltage, a transformer must be used.<br />

The PE terminal must be grounded. See <strong>the</strong> TPC specifications<br />

page for complete power requirements.<br />

x Stand<br />

A stand for <strong>the</strong> TPC controller should be provided by <strong>the</strong><br />

customer. For <strong>the</strong> dimensions and weight of <strong>the</strong> controller, refer<br />

to <strong>the</strong> <strong>the</strong> TPC specifications page.<br />

www.komaprecision.com • info@komaprecision.com<br />