<strong>TRAY</strong> <strong>CABLE</strong>/<strong>CONTROL</strong> <strong>CABLE</strong><br />

Type TC, UL 1277 Article 340<br />

XHHW (VW-1) Insulation Hypalon ® Jacket<br />

Copper Conductors 600 Volt 90°C<br />

Application: Control, power, lighting, and signal multi-conductor circuits, rated 600 Volts.<br />

Installation: In cable trays, raceways, suspended with messenger wire, and direct burial, in industrial plants in cable tray in hazardous<br />

areas per NEC Articles 318 and 501. • May be installed in both wet or dry locations or in areas exposed to chemicals and oils.<br />

• Maximum Conductor Temperatures (continuous): XHHW Wet locations: 75°C, XHHW Dry locations: 90°C,<br />

RHH-2 Dry locations - 90°C, • Ampacity: See Ampacity Tables located in Technical Reference Section in this catalog.<br />

Specifications: • Conductors: Soft, tinned annealed copper per ASTM B-33, Class B stranding per ASTM B-8. Sizes 14 AWG - 12<br />

AWG • Insulation: Flame-retardant cross-linked polyethylene. • Assembly: Conductors are cabled together with or without fillers as<br />

required to form a round, compact cable core and with a binder tape. • Grounding Conductors: when required per UL Standard<br />

1277, bare copper ground wires. • <strong>Cable</strong> Jacket: Sunlight resistant (CSPE) Hypalon rated 90°C per UL Standard 1277.<br />

• Flame Test: <strong>Cable</strong> passes IEEE 383 vertical tray ribbon-burner flame test (210,000BTU).<br />

Catalog No. Size No. of No. of Insulation Jacket Overall Net<br />

AWG Conductors Strands Thickness Thickness Diameter Weight<br />

Mils Mils<br />

P01L11** 14 2 7 30 45 .230 x.367" 73 lbs/mft<br />

P02L11 14 3 7 30 45 .387" 109 lbs/mft<br />

P03L11 14 4 7 30 45 .423" 123 lbs/mft<br />

P04L11 14 5 7 30 45 .462" 158 lbs/mft<br />

P05L11 14 7 7 30 45 .504" 189 lbs/mft<br />

P06L11 14 9 7 30 60 .617" 257 lbs/mft<br />

P07L11 14 12 7 30 60 .677" 318 lbs/mft<br />

P08L11 14 19 7 30 60 .808" 545 lbs/mft<br />

P09L11 14 25 7 30 80 .958" 691 lbs/mft<br />

P10L11 14 30 7 30 80 1.039" 801 lbs/mft<br />

P11L11 14 37 7 30 80 1.122" 940 lbs/mft<br />

P12L11** 12 2 7 30 45 .250 x.407" 90 lbs/mft<br />

P13L11 12 3 7 30 45 .430" 144 lbs/mft<br />

P14L11 12 4 7 30 45 .471" 184 lbs/mft<br />

P15L11 12 5 7 30 60 .546" 233 lbs/mft<br />

P16L11 12 7 7 30 60 .594" 286 lbs/mft<br />

P17L11 12 9 7 30 60 .689" 335 lbs/mft<br />

P18L11 12 12 7 30 60 .758" 446 lbs/mft<br />

P19L11 12 19 7 30 80 .948" 735 lbs/mft<br />

P20L11 12 25 7 30 80 1.075" 921 lbs/mft<br />

P21L11 12 30 7 30 80 1.167" 1080 lbs/mft<br />

P22L11 12 37 7 30 80 1.262" 1332 lbs/mft<br />

* Shipping Tolerances+/-10%<br />

** Flat Construction


<strong>TRAY</strong> <strong>CABLE</strong>/<strong>CONTROL</strong> <strong>CABLE</strong><br />

Type TC, UL 1277 Article 340<br />

XHHW (VW-1) Insulation Hypalon® Jacket<br />

Copper Conductors 600 Volt 90°C<br />

Specifications: • Conductors: Soft, tinned annealed copper per ASTM B-33, Class B stranding per ASTM B-8.<br />

Size 10 AWG.• Insulation: Flame-retardant cross-linked polyethylene. • Assembly: Parallel construction for 2 conductors only.<br />

Multiple conductors are cabled together with or without fillers as required to form a round, compact cable core and with a binder<br />

• Shield: When required, is an Aluminum-mylar tape with a copper drain wire applied over the cable. • <strong>Cable</strong> Jacket: Sunlight<br />

resistant (CSPE) Hypalon rated 90°C per UL Standard 1277. • Flame Test: <strong>Cable</strong> passes IEEE 383 vertical tray ribbon-burner flame<br />

test (210,000BTU).<br />

Catalog No. Size No. of No. of Insulation Jacket Overall Net<br />

AWG Conductors Strands Thickness Thickness Diameter Weight<br />

Mils Mils<br />

P01L12** 10 2 7 30 45 .274x.455" 127 lbs/mft<br />

P02L12 10 3 7 30 45 .482" 185 lbs/mft<br />

P03L12 10 4 7 30 60 .559" 246 lbs/mft<br />

P04L12 10 5 7 30 60 .611" 309 lbs/mft<br />

P05L12 10 7 7 30 60 .666" 362 lbs/mft<br />

P06L12 10 9 7 30 60 .776" 499 lbs/mft<br />

P07L12 10 12 7 30 80 .896" 673 lbs/mft<br />

P08L12 10 16 7 30 80 1.013" 836 lbs/mft<br />

P09L12 10 19 7 30 80 1.068" 953 lbs/mft<br />

P10L12 10 25 7 30 80 1.214" 1260 lbs/mft<br />

P11L12 10 30 7 30 80 1.321" 1525 lbs/mft<br />

P12L12 10 37 7 30 80 1.430" 1900 lbs/mft<br />

* Shipping Tolerances+/-10%<br />

** Flat Construction