<strong>Hubbell</strong> <strong>Industrial</strong> <strong>Controls</strong>, Inc.<br />
DC Contactor Type 264, 400 Ampere<br />
<strong>Price</strong> <strong>List</strong> <strong>42264</strong> • February 2006 • New • Discount Code E45<br />
Type 264<br />
Ordering Information<br />
➢ Type 264 contactors are ordered by Catalog Number as follows: 14-£££-£££-£££<br />
Table 1<br />
Table 2<br />
1. The first eight digits specify the arc chute configuration, mounting arrangement, and AC or DC coil operation (see Table 1)<br />
2. Select the last three digits from Table 2 for the desired coil voltage, main contact and auxiliary contact arrangement.<br />
➢ Technical Data see page 2.<br />
➢ Dimensional Data see pages 3-4<br />
➢ Replacement Parts see <strong>Price</strong> <strong>List</strong> 42000<br />
Type 264 400 Ampere—Table 1<br />
Illustration Description Catalog No.<br />
Type 264<br />
With Arc Chute<br />
A. Contactor without Arc Chute<br />
Sheet Mounted j<br />
DC Operation<br />
B. Contactor with Arc Chute k<br />
1. Sheet Mounted j<br />
DC Operation<br />
a. Positive Arc Chute Polarity<br />
b. Negative Arc Chute Polarity<br />
2. Base Mounted<br />
DC Operation<br />
a. Positive Arc Chute Polarity<br />
b. Negative Arc Chute Polarity<br />
3. Base Mounted<br />
with Rectifier for AC Operation lo<br />
a. Positive Arc Chute Polarity<br />
b. Negative Arc Chute Polarity<br />
Without Auxiliary<br />
Contacts<br />
Type <strong>Price</strong> $<br />
14-428-131<br />
{ SPNO<br />
$1,450<br />
SPDT<br />
$1,688<br />
REV mn $3,376<br />
14-429-464<br />
{ SPNO<br />
$1,790<br />
SPDT<br />
$2,028<br />
14-429-470 REV mn $4,056<br />
14-193-805<br />
{ SPNO<br />
$1,968<br />
SPDT<br />
$2,176<br />
14-193-806 REV mn $4,280<br />
14-193-807<br />
{ SPNO<br />
$2,012<br />
SPDT<br />
$2,250<br />
14-193-808 REV mn $4,426<br />
Approx<br />
Ship Wt<br />
Lbs (Kg)<br />
10 (4.5)<br />
10 (4.5)<br />
20 (9.0)<br />
12.6 (5.7)<br />
12.6 (5.7)<br />
25.2 (11.4)<br />
12.6 (5.7)<br />
12.6 (5.7)<br />
25.2 (11.4)<br />
12.6 (5.7)<br />
12.6 (5.7)<br />
25.2 (11.4)<br />
Type 264<br />
Without Arc Chute<br />
Type 264 400 Ampere—Table 2<br />
Complete Last Three Digits of<br />
Catalog Number from this Table<br />
Main<br />
Contacts<br />
SPNO<br />
1 NO<br />
SPDT<br />
1 NO/1 NC<br />
REV<br />
2-SPDT mn<br />
2 NO/2 NC<br />
Coil Voltage (Volts DC) o<br />
Auxiliary Contacts m<br />
12 24 36 48 74 100 125 250 None 1 NO-1 NC 2 NO-2 NC<br />
<strong>Price</strong><br />
Adder $<br />
561 504 501 502 503 562 563 564 Yes — — —<br />
566 567 506 507 508 569 509 510 — Yes — $60<br />
571 572 511 512 513 574 514 515 — — Yes $180<br />
591 592 531 532 533 594 534 535 Yes — — —<br />
601 602 536 537 538 605 539 540 — Yes — $60<br />
606 607 541 542 543 609 544 545 — — Yes $180<br />
611 612 546 547 548 614 549 550 Yes — — —<br />
616 617 551 552 553 619 554 555 — Yes — $60<br />
621 622 556 557 558 624 559 560 — — Yes $180<br />
j Insulated mounting sheet (1/32” thick) provided with contactor.<br />
k For maximum break rating of polarity sensitive arc chutes, connect<br />
indicated polarity to normally open stationary terminal.<br />
l Coil voltage tolerance 85 to 110% of rated voltage<br />
m For reversers, price two auxiliary contacts: (1) for forward, (1) for reverse.<br />
n Configured for series field reversal.<br />
o For 120 volt, 60Hz operation, use 100 volt DC coil with full<br />
wave bridge rectifier.<br />
Page 1 of 4
DC Contactor Type 264, 400 Ampere<br />
Type 264, ,<br />
Contactor Configuration<br />
Single-pole, normally open, SPNO<br />
Single-pole, double throw, SPDT (1 NO/1 NC)<br />
Series field reverser (2 SPDT bussed together)<br />
Special combinations are available<br />
Consult local <strong>Hubbell</strong> sales office.<br />
Voltage Rating<br />
600V DC standard<br />
Consult local <strong>Hubbell</strong> sales office for special ratings<br />
Mechanical Life<br />
2 million operations<br />
Connection<br />
One 5 / 16-18 tapped hole per terminal<br />
Full Wave Bridge Rectifier Connections (for AC operation)<br />
2 million operations<br />
Mounting<br />
Two ¼-20 screws through contactor and insulation sheet<br />
Three ¼-20 screws through mounting base<br />
Weights j Reversing Non-Reversing<br />
Contactor without Arc Chute 20.0 (9.0) 10.0 (4.5)<br />
Contactor with Arc Chute 25.2 (11.4) 12.6 (5.7)<br />
j Weights are in pounds (kilograms)<br />
k Minimum pickup voltage is 55% of rated coil volts, with cold (20°) coil<br />
and 80% of rated coil volts with hot (105°) coil. Dropout is from 5% to<br />
25% of rated coil volts. All temperatures in °C.<br />
l Resistive load—consult <strong>Hubbell</strong> sales office for inductive load break<br />
ratings. For arc chute spacings to ground, consult <strong>Hubbell</strong> sales office.<br />
m Each normally open and normally closed pair must be wired to the same<br />
side of the same supply (same polarity).<br />
Operating Coil k<br />
Volts DC Ohms (20° C) Volts DC Ohms (20° C)<br />
12<br />
24<br />
36<br />
48<br />
3.42<br />
13.6<br />
31.3<br />
47.9<br />
74<br />
100<br />
125<br />
250<br />
Coil voltage tolerance 80% to 110% of rated voltage<br />
Main Contact Rating<br />
130<br />
307<br />
507<br />
1895<br />
Description Normally Open Normally Closed<br />
Continuous Carry Current<br />
Convection Cooled<br />
425 Amps 400 Amps<br />
Max Make Rating 2000 Amps, 600V DC 2000 Amps, 500V DC<br />
Max Break Rating (Resistive Load, consult local <strong>Hubbell</strong> sales office for<br />
inductive loads).<br />
Without Arc Chute 2000 Amps, 48V DC —<br />
With Arc Chute<br />
1000 Amps, 500V DC<br />
2000 Amps, 300V DC<br />
—<br />
—<br />
For arc spacings to ground, consult local <strong>Hubbell</strong> sales office.<br />
Arc Chute is permanent magnet type. Polarities must be observed.<br />
Auxiliary Contacts<br />
Configuration Continuous Current Make and Break<br />
1 NO and 1 NC 15 Amps<br />
2 NO and 2 NC 10 Amps<br />
15 Amps, 600V AC, resistive<br />
0.4 Amps, 115V DC, inductive<br />
0.2 Amps, 230V DC, inductive<br />
10 Amps, 600V AC, resistive<br />
0.2 Amps, 115V DC, inductive<br />
0.1 Amps, 230V DC, inductive<br />
Page 2 of 4
Page 3 of 4<br />
DC Contactor Type 264, 400 Ampere
DC Contactor Type 264, 400 Ampere<br />
All dimensions shown in inches (millimeters). For<br />
reference purposes only. Not to be used for design<br />
or construction purposes.<br />
<strong>Price</strong>s subject to change without notice.<br />
<strong>Hubbell</strong> <strong>Industrial</strong> <strong>Controls</strong>, Inc.<br />
A subsidiary of <strong>Hubbell</strong> Incorporated<br />
4301 Cheyenne Dr., Archdale, NC 27263<br />
Telephone (336) 434-2800 • FAX (336) 434-2803<br />
http://www.hubbell-icd.com<br />
sales@hubbell-icd.com