EQUIPMENT DATA SHEET<br />
Diesel Generating Set<br />
50Hz 500kVA<br />
60Hz<br />
500kW<br />
No.<br />
Rev.<br />
Date<br />
Page<br />
G08.0137<br />
A<br />
Aug 98<br />
1 of 3<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
Model<br />
Part Number<br />
Specification<br />
Installation Drawing<br />
Maximum Ambient<br />
Electrical Output<br />
ISO 8528-1<br />
- Continuous <strong>Power</strong> (COP)<br />
- Prime <strong>Power</strong> (PRP)<br />
- Permissable average of PRP<br />
ISO3046/1<br />
- Fuel Stop <strong>Power</strong>/Standby<br />
Single Step load application<br />
Alternator<br />
Class F Temp. Rise (105°C)<br />
- Three phase<br />
- Single phase<br />
Ends Out<br />
Make & Type<br />
AVR<br />
Regulation<br />
Circuit Breaker<br />
Make & Type<br />
Number of poles<br />
Rating<br />
Trip Unit Type<br />
Overload <strong>Pro</strong>tection Range<br />
Short Circuit <strong>Pro</strong>tection Range<br />
Load Terminals<br />
Type<br />
Fuel Consumption<br />
Standby/Fuel Stop<br />
100% Prime <strong>Power</strong><br />
75%<br />
50%<br />
SEE NOTE (ii)<br />
Ref<br />
Ref<br />
Ref<br />
SEE NOTE (i) Ref<br />
°C (°F)<br />
kW (kVA)<br />
kW (kVA)<br />
kW (kVA)<br />
Amps<br />
Amps<br />
Amps<br />
lit/hr(US gal/hr)<br />
" "<br />
" "<br />
" "<br />
Technical Department - Dumbarton Approved by<br />
Hz<br />
kW (kVA)<br />
kW (kVA)<br />
%<br />
%<br />
%<br />
NHC20 / KTA19G4<br />
602050<br />
602051<br />
602061<br />
602074<br />
G32.0016<br />
A05.0068<br />
56 (132)<br />
50<br />
328 (410)<br />
416 (520)<br />
70<br />
467 (584)<br />
64<br />
443 (554)<br />
176 (220)<br />
12<br />
Newage Stamford HCI534E2<br />
MX321<br />
± 0.5<br />
Terasaki XS1250NE<br />
4<br />
1250<br />
Electronic<br />
630 - 1250<br />
2363 - 15000<br />
Busbar M12<br />
121 (31.9)<br />
107 (28.4)<br />
UNCONTROLLED<br />
82 (21.6)<br />
57 (14.9)<br />
53 (127)<br />
60<br />
397 (496)<br />
470 (588)<br />
70<br />
523 (654)<br />
64<br />
520 (650)<br />
182 (228)<br />
133 (35.2)<br />
120 (31.7)<br />
92 (24.3)<br />
65 (17.0)<br />
FOR INFORMATION ONLY
Manufacturing<br />
Birch Road<br />
Dumbarton, G82 2RF<br />
Tel: 0044 (0)1389 742214<br />
Fax: 0044 (0)1389 742554<br />
EQUIPMENT DATA SHEET<br />
Diesel Generating Set<br />
50Hz 500kVA<br />
60Hz<br />
500kW<br />
No.<br />
Rev.<br />
Date<br />
Page<br />
G08.0137<br />
A<br />
Aug 98<br />
2 of 3<br />
11<br />
Running Hours<br />
100% Prime <strong>Power</strong><br />
Hours<br />
11.7<br />
10.4<br />
75%<br />
15.3<br />
13.6<br />
50%<br />
22.0<br />
19.3<br />
12<br />
Exhaust Emissions<br />
Measurement Method<br />
Cummins Exhaust Emissions Data Sheet<br />
Specific Load<br />
100% Prime ±2%<br />
NOx - Oxides of Nitrogen<br />
(g/kW.h)<br />
12.30<br />
12.06<br />
PM - Particulate Matter<br />
0.20<br />
0.13<br />
CO - Carbon Monoxide<br />
4.29<br />
1.23<br />
HC - Unburnt Hydrocarbons<br />
0.23<br />
0.25<br />
13<br />
Exhaust Silencer<br />
Make & Type<br />
Discom or IMS type MAA<br />
Certificate<br />
No<br />
M-8872 or M-8154<br />
Permissable back pressure<br />
mm (ins) Hg<br />
12 (0.5”)<br />
12 (0.5”)<br />
14<br />
Noise<br />
Sound <strong>Power</strong> - EEC<br />
dBA (Lw)<br />
98.7<br />
Certificate<br />
No<br />
GB/02/778/97<br />
Sound Pressure at 1 metre<br />
dBA<br />
77<br />
80<br />
Sound Pressure at 7 metre<br />
dBA<br />
74<br />
77<br />
15<br />
Engine<br />
Make & Type<br />
Cummins KTA19G4<br />
Cylinders & Form<br />
6 Inline<br />
Aspiration<br />
Turbocharged and Aftercooled<br />
Fuel Pump<br />
Cummins PT<br />
Governor Type<br />
Electronic<br />
Make & Model<br />
Cummins EFC<br />
Steady State frequency<br />
%<br />
± 0.25<br />
Battery Voltage<br />
Volts<br />
24<br />
16<br />
Overall Dimensions<br />
SEE NOTE (i)<br />
- Length<br />
Metres (feet)<br />
6.06 (20’0”)<br />
- Width<br />
Metres (feet)<br />
2.44 (8’0”)<br />
- Height<br />
Metres (feet)<br />
2.60 (8’6”)<br />
17<br />
Weight<br />
SEE NOTE (i)<br />
- Without fuel<br />
Kg (lbs)<br />
10856 (23933)<br />
- With fuel<br />
Kg (lbs)<br />
12072 (26614)<br />
UNCONTROLLED<br />
Technical Department - Dumbarton Approved by<br />
FOR INFORMATION ONLY
Manufacturing<br />
Birch Road<br />
Dumbarton, G82 2RF<br />
Tel: 0044 (0)1389 742214<br />
Fax: 0044 (0)1389 742554<br />
EQUIPMENT DATA SHEET<br />
Diesel Generating Set<br />
50Hz 500kVA<br />
60Hz<br />
500kW<br />
No.<br />
Rev.<br />
Date<br />
Page<br />
G08.0137<br />
A<br />
Aug 98<br />
3 of 3<br />
18<br />
Capacities<br />
- Fuel gross<br />
Litres (US gall)<br />
1431 (378)<br />
usable<br />
1253 (331)<br />
- Lub oil total<br />
50 (13)<br />
pan<br />
38-32 (10-8.5)<br />
- Coolant<br />
112 (30)<br />
19<br />
External fuel supply<br />
- maximum above base<br />
Metres (feet)<br />
2.40 (7’10”)<br />
- maximum below base<br />
Metres (feet)<br />
1.50 (4’11”)<br />
Notes<br />
(i)<br />
(ii)<br />
On the DNV model the following applies:<br />
4. Installation Drawing Ref A05.0107<br />
16. Length Metres (feet) 6.18 (20’3”)<br />
17. Weight<br />
- Without fuel Kg (lbs) 12336 (27196)<br />
- With fuel Kg (lbs) 13552 (29877)<br />
On USA and AIP (602074) specification sets, the following UL approved circuit breaker is fitted:<br />
Make and Type<br />
Merlin Gerin UL Masterpact MP20 ACB<br />
Number of Poles 3<br />
Rating Amps 2000<br />
Trip Unit Type<br />
STR58U<br />
Overload <strong>Pro</strong>tection Range Amps 800 - 2000 (rating plug dependent)<br />
Short Circuit <strong>Pro</strong>tection Range Amps 1200 - 20000 (rating plug dependent)<br />
On plant numbers 7921 onwards an IEC type control unit is fitted in place of rating plugs. Therefore, the<br />
protection ranges, dependent on position of selector switch are as follows:<br />
Overload <strong>Pro</strong>tection Range Amps 800 - 2000<br />
Short Circuit <strong>Pro</strong>tection Range Amps 4000 - 40000<br />
UNCONTROLLED<br />
Technical Department - Dumbarton Approved by<br />
FOR INFORMATION ONLY