PRODUCT DATA SHEET<br />

<strong>ACO</strong> - <strong>ATTENDANT</strong><br />

<strong>CONTROL</strong> <strong>OPENBUS</strong><br />

Features:<br />

• Controls up to 5 channels in connection with<br />

CB16 and CB20, CB6S (only 4 ch)<br />

• Ergonomically shaped and easy to hold and<br />

operate with two hands<br />

• Standard front cover has improved user layout.<br />

The self-explanatory buttons and their<br />

functions are easy to locate and operate<br />

• High strength plastic housing protects the<br />

electronics<br />

• Cleaning is made fast and easy because of<br />

rounded contours and assembly of the cover<br />

onto a low edged surface<br />

• Protection against single fault condition<br />

according to EN 60601-1 when connected with<br />

control boxes that use an OpenBus interface<br />

e.g. CB20.<br />

• A LED indicates when the battery is being<br />

charged (yellow)<br />

• Protection class: IPX6 or IPX6W<br />

• Colour: Grey RAL 7035<br />

• Connection to CB or MJB via a “modular jack”<br />

cable<br />

• Flexible “hook” (dimensioned to fit onto either<br />

a Ø32 mm or 42 mm rail)<br />

• The front cover seals the <strong>ACO</strong> housing<br />

Options:<br />

• Customised front cover<br />

It is possible to design front covers where the<br />

keys and LED´s are placed differently than on<br />

the standard LINAK front covers. This involves<br />

some development and tooling changes / costs.<br />

Usage:<br />

• Compatible with OpenBus e.g. CB20, CB6S<br />

and CB16<br />

• Ambient temperature +5˚ to + 40˚C<br />

• <strong>ACO</strong> IPX6-Washable is approved according to<br />

EN60601-2-52.<br />

In order to comply with the norm the <strong>ACO</strong> must<br />

hang vertically from it’s hook during the<br />

washing process, see the picture next page<br />

Current consumption:<br />

• 15 mA (Standard versions with 5 no. LED’s<br />

(5 LED’s x 2 mA = 10 mA) + microprocessor<br />

5 mA, total = 15 mA<br />

The <strong>ACO</strong> (Attendant Control OpenBus) is a cost<br />

optimised and compact unit with up to 15 buttons that<br />

can be used as Handset keys or Lock-outs.<br />

The lock-out function can be made visable by using<br />

yellow LED´s.<br />

The <strong>ACO</strong> is compatible with control boxes that use an<br />

OpenBus interface i.e. CB6S, CB16 and CB20.<br />

The <strong>ACO</strong> is for use with advanced hospital and patient<br />

care beds (nursing beds) where patient positioning must<br />

be carefully controlled by medical staff.<br />

The <strong>ACO</strong> allows nursing staff to retain direct control over<br />

critical positioning functions while giving the patient a<br />

limited degree of adjustment.<br />

This high degree of selective control is vital in cases such<br />

as spinal injuries and other similar conditions where<br />

backrest positioning must be carefully supervised.<br />

The <strong>ACO</strong> is ergonomically designed and easy to install on<br />

even the most advanced equipment.<br />

The <strong>ACO</strong> has a flexible “hook” which enables it to be<br />

positioned according to the nurses wishes, out of reach<br />

of the patient (for example at the end of the bed),<br />

and serves to block the handset functions that may be<br />

inappropriate, or even dangerous to the patient, (for<br />

example in connection with a broken leg).


<strong>ACO</strong> in the vertical position.<br />

Recommendations:<br />

• Always use Locking ring and cables with O-rings.<br />

• Locking ring and cables with O-rings must be fitted to ensure IP degree.<br />

• If other front covers than standards are requested, the customer must design them.<br />

• Cables are inclusive an O-ring.<br />

Dimensions<br />

R16<br />

29.6<br />

Dimensions with Ø42 hook


<strong>ACO</strong><br />

Ordering example:<br />

AC O 6 0 01 02 + 0 0 0 00<br />

<strong>ACO</strong> always without cable<br />

Not Used<br />

Hook:<br />

0: ø 32mm<br />

1: ø 42mm<br />

Activator type: 0 = Normal touch (Dome = A)<br />

Box colour:<br />

+ = Grey - RAL7035<br />

Front cover number:<br />

Functionality:<br />

Charging indicator:<br />

IP degree:<br />

Type:<br />

See overview<br />

01-99<br />

0 = No<br />

1 = Yes<br />

6 = IPX6<br />

9 = IPX6 - Washable<br />

O = Open Bus -(Attendant Control Open Bus)<br />

Attendant Control<br />

Cables:<br />

0277054-300 : Modular Jack-modular Jack (5-wire straight)<br />

0277054-1250 : Modular Jack-modular Jack (5-wire straight)<br />

0277054-2500 : Modular Jack-modular Jack (5-wire straight)<br />

0964110-500 : Modular Jack 6-wire, straight, RAL7035, length 500 mm<br />

0964110-600 : Modular Jack 6-wire, straight, RAL7035, length 600 mm<br />

0964110-800 : Modular Jack 6-wire, straight, RAL7035, length 800 mm<br />

0964233 : Modular Jack-modular Jack, Jacket material: PVC; (6-wire 650 mm coiled; a 6-wire cable is needed when<br />

e.g. using backlight)<br />

0964541 : Modular Jack-modular Jack, Jacket material: PU; (6-wire 650mm coiled; a 6-wire cable is needed when<br />

e.g. using backlight). This cable should be selected if there is a washable product.


How to connect the <strong>ACO</strong> box:<br />

OpenBus CB (CB6S) <strong>ACO</strong> Handset<br />

Alternatively:<br />

OpenBus CB (CB16) <strong>ACO</strong> Handset<br />

Functionality Overview and Standard front covers:<br />

01 OpenBus (via xx-p. Mod. Jack (RJ45)


Standard front covers:<br />

00<strong>ACO</strong>1A-001<br />

Especially designed for use with CB16 OBL<br />

00<strong>ACO</strong>1A-002<br />

Especially designed for use with CB6S OBL.<br />

CB6S does not support charging indicator and CPR.<br />

00<strong>ACO</strong>1A-004<br />

Designed to be used for sample orders,<br />

SW specification, tests etc.”<br />

00<strong>ACO</strong>1A-005<br />

00<strong>ACO</strong>1A-017<br />

00<strong>ACO</strong>1A-018<br />

00<strong>ACO</strong>1A-019<br />

For customised front covers please contact LINAK A/S.


Terms of use<br />

The user is responsible for determining the suitability of LINAK products for specific application.<br />

LINAK takes great care in providing accurate and up-to-date information on its products.<br />

However, due to continuous development in order to improve its products, LINAK products are<br />

subject to frequent modifications and changes without prior notice. Therefore, LINAK cannot<br />

guarantee the correct and actual status of said information on its products.<br />

While LINAK uses its best efforts to fulfil orders, LINAK cannot, for the same reasons as<br />

mentioned above, guarantee the availability of any particular product. Therefore, LINAK reserves<br />

the right to discontinue the sale of any product displayed on its website or listed in its catalogues<br />

or other written material drawn up by LINAK.<br />

All sales are subject to the Standard Terms of Sale and Delivery for LINAK. For a copy hereof,<br />

please contact LINAK.<br />

Copyright © LINAK 2013.06 MA M9-02-241-E . Chapter 9.20