ALARM<br />

A <strong>Division</strong> <strong>of</strong> <strong>Advanced</strong> <strong>Protection</strong> <strong>Technologies</strong>, <strong>Inc</strong>.<br />

Main Zone Protector<br />

TE/1C40<br />

The surgeassure TM TE/1C40 shields motor-driven appliances<br />

in residential and light commercial applications against<br />

electrical power surge damage from entering through the<br />

main electrical service panel.<br />

Multiple MOV technology with thermal disconnect to prevent<br />

catastrophic failure.<br />

Two LED lights indicate protection status. An audible alarm<br />

alerts you when protection is disrupted.<br />

Unique Ground Status Monitoring Circuit provides notifi cation<br />

if excessive Neutral-Ground voltage is present, a red indicator<br />

light will fl ash and the audible alarm will activate.<br />

Major household electrical and electronic equipment are<br />

covered against surge damage for 10 years when a TE/1C40<br />

is installed by a licensed electrician.<br />

If the TE/1C40 surge protector is damaged during the fi rst 10<br />

years <strong>of</strong> ownership surgeassure TM will replace it free <strong>of</strong> charge!<br />

INSTALLATION: SEE TE/1C40 USER’S MANUAL<br />

N<br />

A<br />

B<br />

BREAKER<br />

G<br />

• Use closest breaker to SPD<br />

• Locate SPD close to<br />

intended breaker<br />

• Keep Leads Short as Possible<br />

• Avoid Sharp Bends<br />

• Rotate SPD such<br />

that LED indicator is<br />

most visible<br />

• Outdoor installation requires<br />

appropriate weather sealing at<br />

nipple (sealing conduit, etc.)<br />

FEATURES AND BENEFITS<br />

• UL 1449 3rd Edition listed Type 2 Surge<br />

Protective Device<br />

• Rated for single phase panels up to 400 Amps<br />

• Installation flexibility<br />

• Audible Alarm<br />

• Internal diagnostics keep you informed<br />

• Ground Status Monitoring<br />

• 10 Year product warranty<br />

TECHNICAL SPECIFICATIONS<br />

AC SURGE PROTECTION<br />

Thermal Fusing<br />

Yes<br />

Catastrophic Surge Circuit Yes<br />

Spike Capacity<br />

40,000 Amps<br />

Line Voltage<br />

120/240 1 Phase 50/60 Hz<br />

Initial Clamping Level<br />

700V<br />

Rated Voltage<br />

150V<br />

Response Time<br />

Hooray! Your file is uploaded and ready to be published.