APPLICATION - Manuli Hydraulics
APPLICATION - Manuli Hydraulics
APPLICATION - Manuli Hydraulics
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Q.Safe 2010 novelties<br />
www.manuli-hydraulics.com<br />
July, 2010 - Q.Safe 2010
Q.Safe - 2010 NEW PRODUCTS<br />
MQS-FP: Male Flat-face conn. under Pressure MQS-F: 1.000.000 impulses cycles<br />
MQS-FP Male Flat face connectable under Pressure<br />
• Triple valve system that guarantee connection under pressure (female part always with 0MPa) safely with low<br />
connection effort<br />
• Working pressure 35MPa<br />
• Safety factor: 1:4 dynamic pressures and 1:2 for static ones ; IMPULSE PRESSURE: 1.000.000 cycles<br />
(connected and disconnected conditions) at 120% of the rated one (freq.1Hz); - TEST SPECIFICATIONS: ISO<br />
7241-2 and ISO 16028:1997aMD.1.2006(E)<br />
• Interchangeable according to ISO 16028<br />
<strong>APPLICATION</strong><br />
Construction and earth moving machine , Forestry and Industry<br />
MQS-F Flat-Face 1.000.000 impulse cycles<br />
• IMPULSE PRESSURE: 1.000.000 cycles (connected conditions) and 100.000 cycles (disconnected conditions)<br />
at 133% of the rated one (freq.1Hz);<br />
• ISO 16028:1997aMD.1.2006(E)<br />
• Safety factor: 1:4 dynamic pressures and 1:2 for static ones<br />
<strong>APPLICATION</strong><br />
Hyd. Hammers, rock crushers, polyp grab<br />
July, 2010 - Q.Safe 2010<br />
2
Q.Safe - 2010 NEW PRODUCTS<br />
MQS-SH: Screw very High pressure; MQS- Costumized version; MQS- Accessories and spare parts<br />
MQS-SH Screw very High pressure<br />
• Connectable/disconnectable under pressure<br />
• Working pressure from 60MPa to 70MPa<br />
• Internal components reinforced, hardened on the most stressed point<br />
• Mechanical backstop to prevent partial enclosures of valves due to peaks and reverse flow<br />
• IMPULSE PRESSURE: 500.000 cycles (connected and disconnected conditions) at 120% of the rated one<br />
(freq.1Hz);<br />
<strong>APPLICATION</strong><br />
Quick couplings used in application where is necessary GREAT resistance to back-flow, flow impulse, flow<br />
peaks,pressure impulse,pressure peaks,vibration and connection/disconnection<br />
under high pressure (hyd. Hammers, rock crushers, polyp grab)<br />
July, 2010 - Q.Safe 2010<br />
3
Q.Safe - 2010 NEW PRODUCTS<br />
MQS-DHI: Quick couplings Direct Hose Integration maintenance without flexible hose replacement<br />
WITHOUT<br />
DISASSEMBLY OPERATIONS<br />
OF QUICK COUPLING<br />
95% of failures in the quick coupling applications, are caused by a<br />
damage of the sealing system between male and female<br />
couplings<br />
in connected condition.<br />
EASY OPERATIONS TO REPLACE SEALS THANKS TO SPARE PARTS<br />
AND DETAILED INSTRUCTIONS<br />
PUSH-PULL ISO A FLAT-FACE<br />
NO DISASSEBLY Q.SAFE --- NO REPLACEMENT HOSE<br />
July, 2010 - Q.Safe 2010<br />
DHI<br />
MAINTENANCE<br />
WITH<br />
DISASSEMBLY OPERATIONS<br />
OF QUICK COUPLING<br />
Only 5% of failures are caused by damage of<br />
internal sealing areas of quick couplings<br />
REPLACE SEALS & COMPONENTS THANKS TO SPARE PARTS AND<br />
DETAILED INSTRUCTIONS<br />
Spare<br />
part<br />
DISASSEBLY Q.SAFE ---<br />
Hose<br />
NO REPLACEMENT HOSE<br />
4
July, 2010 - Q.Safe 2010<br />
5