Q.Safe 2010 novelties<br />

www.manuli-hydraulics.com<br />

July, 2010 - Q.Safe 2010


Q.Safe - 2010 NEW PRODUCTS<br />

MQS-FP: Male Flat-face conn. under Pressure MQS-F: 1.000.000 impulses cycles<br />

MQS-FP Male Flat face connectable under Pressure<br />

• Triple valve system that guarantee connection under pressure (female part always with 0MPa) safely with low<br />

connection effort<br />

• Working pressure 35MPa<br />

• Safety factor: 1:4 dynamic pressures and 1:2 for static ones ; IMPULSE PRESSURE: 1.000.000 cycles<br />

(connected and disconnected conditions) at 120% of the rated one (freq.1Hz); - TEST SPECIFICATIONS: ISO<br />

7241-2 and ISO 16028:1997aMD.1.2006(E)<br />

• Interchangeable according to ISO 16028<br />

<strong>APPLICATION</strong><br />

Construction and earth moving machine , Forestry and Industry<br />

MQS-F Flat-Face 1.000.000 impulse cycles<br />

• IMPULSE PRESSURE: 1.000.000 cycles (connected conditions) and 100.000 cycles (disconnected conditions)<br />

at 133% of the rated one (freq.1Hz);<br />

• ISO 16028:1997aMD.1.2006(E)<br />

• Safety factor: 1:4 dynamic pressures and 1:2 for static ones<br />

<strong>APPLICATION</strong><br />

Hyd. Hammers, rock crushers, polyp grab<br />

July, 2010 - Q.Safe 2010<br />

2


Q.Safe - 2010 NEW PRODUCTS<br />

MQS-SH: Screw very High pressure; MQS- Costumized version; MQS- Accessories and spare parts<br />

MQS-SH Screw very High pressure<br />

• Connectable/disconnectable under pressure<br />

• Working pressure from 60MPa to 70MPa<br />

• Internal components reinforced, hardened on the most stressed point<br />

• Mechanical backstop to prevent partial enclosures of valves due to peaks and reverse flow<br />

• IMPULSE PRESSURE: 500.000 cycles (connected and disconnected conditions) at 120% of the rated one<br />

(freq.1Hz);<br />

<strong>APPLICATION</strong><br />

Quick couplings used in application where is necessary GREAT resistance to back-flow, flow impulse, flow<br />

peaks,pressure impulse,pressure peaks,vibration and connection/disconnection<br />

under high pressure (hyd. Hammers, rock crushers, polyp grab)<br />

July, 2010 - Q.Safe 2010<br />

3


Q.Safe - 2010 NEW PRODUCTS<br />

MQS-DHI: Quick couplings Direct Hose Integration maintenance without flexible hose replacement<br />

WITHOUT<br />

DISASSEMBLY OPERATIONS<br />

OF QUICK COUPLING<br />

95% of failures in the quick coupling applications, are caused by a<br />

damage of the sealing system between male and female<br />

couplings<br />

in connected condition.<br />

EASY OPERATIONS TO REPLACE SEALS THANKS TO SPARE PARTS<br />

AND DETAILED INSTRUCTIONS<br />

PUSH-PULL ISO A FLAT-FACE<br />

NO DISASSEBLY Q.SAFE --- NO REPLACEMENT HOSE<br />

July, 2010 - Q.Safe 2010<br />

DHI<br />

MAINTENANCE<br />

WITH<br />

DISASSEMBLY OPERATIONS<br />

OF QUICK COUPLING<br />

Only 5% of failures are caused by damage of<br />

internal sealing areas of quick couplings<br />

REPLACE SEALS & COMPONENTS THANKS TO SPARE PARTS AND<br />

DETAILED INSTRUCTIONS<br />

Spare<br />

part<br />

DISASSEBLY Q.SAFE ---<br />

Hose<br />

NO REPLACEMENT HOSE<br />

4