Find this product online at www.eland.co.uk | Electrical <strong>Cable</strong> | <strong>Traffic</strong> <strong>Signal</strong> <strong>Cable</strong><br />

<strong>Traffic</strong> <strong>Signal</strong> <strong>Cable</strong> <strong>–</strong> <strong>BS</strong> <strong>6346</strong> <strong>SWA</strong> <strong>PVC</strong><br />

<strong>Eland</strong> Product Group A6T<br />

Application<br />

For the interconnection of traffic signal equipment or other applications requiring high core configurations with mechanical robustness.<br />

Standards<br />

Generally to <strong>BS</strong> <strong>6346</strong>, <strong>BS</strong> EN/IEC 60228, <strong>BS</strong> EN/IEC 60332-1-2, <strong>BS</strong> EN/IEC 50363-2:2007<br />

Technical Data<br />

Conductor<br />

Class 1 plain annealed copper conductor to <strong>BS</strong> EN 60228.<br />

Insulation<br />

Type TI1 to <strong>BS</strong> EN 50363-3:2007<br />

Bedding<br />

Polymeric compound with a tensile strength of not less than N/mm 2<br />

and an elongation break at not less than 50%.<br />

Armouring<br />

Single layer of galvanized wires laid in a right direction.<br />

Sheath<br />

<strong>PVC</strong> (PolyVinyl Chloride) conforming to the requirements of TM1 as<br />

specified in <strong>BS</strong> EN 50363-4-1:2005.<br />

Sheath Colour<br />

Orange (Ral 2008)<br />

Voltage Rating<br />

600/1000V<br />

Temperature Rating<br />

-15°C to +70°C<br />

Minimum Bending Radius<br />

6 x overall diameter<br />

Core Identification<br />

8 cores:<br />

Centre Lay (Right Hand Lay) - Brown<br />

Second Layer (Left Hand Lay) - Yellow, Green/Blue, Red, White, Blue,<br />

Black, Orange<br />

12 cores:<br />

Centre Lay (Right Hand Lay) - Brown , Yellow, Green/Blue<br />

Second Layer (Left Hand Lay) - Red, White, Blue, Black, Orange,<br />

Red/White, Grey, Red/Blue, Violet<br />

16 cores:<br />

Centre Lay (Right Hand Lay) - Brown , Yellow, Green/Blue, Red, White<br />

Second Layer (Left Hand Lay) - Blue, Black, Orange, Red/White, Grey,<br />

Red/Blue, Violet, Brown/Red, Yellow/Red, Grey/Red, Black/Red<br />

20 cores:<br />

Centre Lay (Right Hand Lay) - Brown , Yellow, Green/Blue, Red,<br />

White, Blue, Black<br />

Second Layer (Left Hand Lay) - Orange, Red/White, Grey, Red/Blue,<br />

Violet, Brown/Red, Yellow/Red, Grey/Red, Black/Red, Violet/Red,<br />

Orange/Red, Green/Red, Blue/White<br />

Short Circuit Temperature<br />

160ºC<br />

Dimensions<br />

<strong>Traffic</strong> <strong>Signal</strong> - <strong>BS</strong> <strong>6346</strong> <strong>SWA</strong> <strong>PVC</strong><br />

<strong>Eland</strong> Part<br />

Number<br />

No. of Cores x<br />

Nominal Cross<br />

Sectional Area<br />

# x mm²<br />

No. and<br />

Diameter of<br />

Wires<br />

mm<br />

Nominal<br />

Thickness<br />

of Insulation<br />

mm<br />

Bedding<br />

Thickness<br />

mm<br />

Diameter of<br />

Steel Wire<br />

mm<br />

Thickness of<br />

Sheath<br />

mm<br />

Nominal<br />

Overall<br />

Diameter<br />

mm<br />

A6T08010<strong>SWA</strong> 8 x 1.00 1.13 0.6 0.8 0.90 1.4 13.2 388<br />

A6T08015<strong>SWA</strong> 12 x 1.00 1.13 0.6 0.8 1.25 1.4 16.2 615<br />

A6T12010<strong>SWA</strong> 16 x 1.00 1.13 0.6 0.8 1.25 1.5 17.6 725<br />

A6T12015<strong>SWA</strong> 20 x 1.00 1.13 0.6 0.8 1.25 1.6 19.0 841<br />

A6T16010<strong>SWA</strong> 8 x 1.50 1.38 0.6 0.8 0.90 1.4 13.9 451<br />

A6T16015<strong>SWA</strong> 12 x 1.50 1.38 0.6 0.8 1.25 1.5 17.4 729<br />

A6T20010<strong>SWA</strong> 16 x 1.50 1.38 0.6 0.8 1.25 1.6 18.9 864<br />

A6T20015<strong>SWA</strong> 20 x 1.50 1.38 0.6 0.8 1.25 1.6 20.2 997<br />

Nominal<br />

Weight<br />

kg/km<br />

Issue 03.0910<br />

sales@eland.co.uk www.eland.co.uk tel +44 (0)20 7241 8787 fax +44 (0)20 7241 8700<br />

Page 1 of 2


Find this product online at www.eland.co.uk | Electrical <strong>Cable</strong> | <strong>Traffic</strong> <strong>Signal</strong> <strong>Cable</strong><br />

Conductors<br />

Class 1 solid conductors for Single Core and Multi-Core cables<br />

1 2<br />

Nominal Cross Sectional Area<br />

mm 2 Maximum Resistance of Conductor at 20ºC<br />

Circular, Annealed Copper Conductors<br />

Plain<br />

ohms/Km<br />

Table in accordance with <strong>BS</strong> EN 60228:2005 (previously <strong>BS</strong>6360)<br />

Electrical Characteristics<br />

Current Carrying Capacity (amperes)<br />

No. of Cores x Nominal<br />

Cross Sectional Area<br />

# x mm²<br />

1.00 18.1000<br />

1.50 12.1000<br />

Maximum Conductor<br />

Resistance at 20ºC<br />

ohm/km<br />

Voltage Drop<br />

mV/A/m<br />

In Air<br />

Current Carrying Capacity<br />

Direct Burial<br />

8 x 1.00 18.1 25 12 10.5<br />

12 x 1.00 18.1 25 10 8.7<br />

16 x 1.00 18.1 25 9 8.0<br />

20 x 1.00 18.1 25 8 7.1<br />

8 x 1.50 12.1 38 15 13.5<br />

12 x 1.50 12.1 38 13 11.7<br />

16 x 1.50 12.1 38 11 10.0<br />

20 x 1.50 12.1 38 10 9.1<br />

The information contained within this datasheet is for guidance only. When selecting accessories such as cleats, glands, etc please note that actual cable<br />

dimensions may vary due to manufacturing tolerances.<br />

sales@eland.co.uk www.eland.co.uk tel +44 (0)20 7241 8787 fax +44 (0)20 7241 8700<br />