Technical Specifications<br />
Probe tone:<br />
Air pressure:<br />
Function:<br />
Eustachian Tube<br />
Function:<br />
Acoustic Reflex tests:<br />
Frequencies <strong>and</strong><br />
intensity ranges:<br />
Attenuator:<br />
Memory:<br />
Audiometer<br />
Functions:<br />
PC Communication:<br />
Printer<br />
Compatible Windows<br />
software:<br />
Power Supply:<br />
Consumption:<br />
Dimensions/weight:<br />
Frequency: 226Hz. <strong>AT235</strong>h also: 678Hz, 800Hz, 1000Hz for traditional IYI-curve tympanometry.<br />
Level: 85 db SPL. Gain Control: AGC.<br />
Control: Automatic. Range: Default +200 to –400daPa (max. +300 to -600daPa).<br />
Safety limitation: -800 daPa <strong>and</strong> +600 daPa.<br />
Pressure change rate: Selectable in the set-up between 50, 150 <strong>and</strong> >250 daPa/s or automatic.<br />
Compliance: Range: 0.1 to 6.0 ml (numerical: 0.1 to 8.0 ml).<br />
Automatic, where pump speed, start <strong>and</strong> stop pressure can be userprogrammed in the set-up.<br />
<strong>AT235</strong>h: Auto <strong>and</strong> manual pump functions.<br />
<strong>AT235</strong>: Function test for use when the eardrum is intact.<br />
<strong>AT235</strong>h: Function tests for use with both intact <strong>and</strong> perforated eardrums.<br />
Atomatic reflex: Two independent user selectable protocols. Series of fixed intensities available.<br />
Automated intensity search functions available for threshold search <strong>and</strong> reflex growth indication.<br />
Free mixing of Ipsi <strong>and</strong> Contra.<br />
Manual reflex: Manual control of all stimuli. May also be used to redo part of automated test results.<br />
Reflex decay: Manual control, with stimulus duration of 10 sec. Ipsi or contralateral stimulation.<br />
Ipsilateral: Intensitiy up to 110dBHL. Frequency: 250, 500, 1000, 2000, 3000, 4000, WB, HP, LP noise<br />
Contralateral: Intensity up to 120dBHL. Frequency: 125 to 8000Hz, WB, LP, HP noise<br />
Audiometry: Intensity from -10 to 120dBHL. Frequency from 125Hz to 8000Hz<br />
1dB or 5dB steps.<br />
Internal memory for two ears. Each ear: 6 Ipsi <strong>and</strong> 6 Contra recordings. Each may have up to 6 stimuli.<br />
Also, there is memory for additional manual reflex recordings. (Total max. 78 reflexes per ear).<br />
Manual Audiometry.<br />
Automatic Audiometry according to ISO 8253-1 (Patient controlled Hughson-Westlake).<br />
Input/output for computer communication via USB. One mode allows an external PC to both monitor<br />
<strong>and</strong> control the instrument. The control actions can be followed on the display <strong>and</strong> operation panel.<br />
Online communication, where the measurement data are sent to an external PC can be selected.<br />
Built-in fast thermal printer with paper width: 112 mm.<br />
Interacoustics OtoAccess Database.<br />
IA-NOAH-Imp Module for interfacing to NOAH.<br />
UPS400 (Included) 100-240V.<br />
15VA, max. 45VA.<br />
(LxWxH): 36x26x10 cm / 14x10x4 inches. Weight: 2.8 kg / 6 lbs.<br />
Impedance st<strong>and</strong>ard: IEC 60645-5/ANSI S3.39, Type 2.<br />
Audiometer st<strong>and</strong>ard:<br />
IEC 60645-1/ANSI S.3.6, Type 4 Tone.<br />
Safety st<strong>and</strong>ard: IEC 60601-1, Class I, Type B.<br />
Medical CE-mark:<br />
Printer Option:<br />
Included Parts:<br />
Yes<br />
<strong>AT235</strong>/<strong>AT235</strong>h-xp is identical to the <strong>AT235</strong>/<strong>AT235</strong>h but has no built-in printer. Suitable for<br />
installations where computer connection takes care of printing.<br />
ATP-<strong>AT235</strong>u Universal Probe System with<br />
shoulder strap <strong>and</strong> wrist strap<br />
HBZ235u Single Contralateral Headset<br />
UPS400 External Switch Mode Power Supply<br />
Power Cable (110/220V, please specify)<br />
BET50 Box of 65 assorted Eartips<br />
TPR26 3 Rolls of Recording Paper<br />
PCR-<strong>AT235</strong> Dust Cover<br />
Operation manual CD<br />
Multilingual CE manual<br />
Other Middle Ear Analyzers:<br />
• MT10 H<strong>and</strong>held Tympanometer<br />
Audiometry <strong>and</strong> Middle Ear<br />
Analyzer in one:<br />
• AA220 Audio Traveller<br />
• AA222 Audio Traveller<br />
Hard shell carrying case<br />
Printout from <strong>AT235</strong><br />
Optional Parts:<br />
Sales <strong>and</strong> service in your area:<br />
Interacoustics A/S<br />
TDH39 Audiometric Headset<br />
EAR-Tone5A Insert Phones for Audiometry<br />
ACC25 Carrying Case<br />
CIR22 Contralateral Insert Phone<br />
APS3 Response switch<br />
Phone: +45 6371 3555 · Fax: +45 6371 3522<br />
E-mail: info@interacoustics.com<br />
DK-5610 Assens, Denmark<br />
Web: www.interacoustics.com<br />
CAT40 Calibration Unit 0.2-0.5-2.0-5.0 ml<br />
IES-2 Impedance Ear Simulator<br />
OtoAccess Database <strong>and</strong> diagnostic modules<br />
software<br />
IA-NOAH-Imp module<br />
Printout from <strong>AT235</strong>h<br />
Read more here:<br />
www.interacoustics.com/com/<strong>AT235</strong> or <strong>AT235</strong>h<br />
Interacoustics ®<br />
®<br />
leading diagnostic solutions<br />
83004703 - 4 - 10/2008