Technical Specifications<br />

Probe tone:<br />

Air pressure:<br />

Function:<br />

Eustachian Tube<br />

Function:<br />

Acoustic Reflex tests:<br />

Frequencies <strong>and</strong><br />

intensity ranges:<br />

Attenuator:<br />

Memory:<br />

Audiometer<br />

Functions:<br />

PC Communication:<br />

Printer<br />

Compatible Windows<br />

software:<br />

Power Supply:<br />

Consumption:<br />

Dimensions/weight:<br />

Frequency: 226Hz. <strong>AT235</strong>h also: 678Hz, 800Hz, 1000Hz for traditional IYI-curve tympanometry.<br />

Level: 85 db SPL. Gain Control: AGC.<br />

Control: Automatic. Range: Default +200 to –400daPa (max. +300 to -600daPa).<br />

Safety limitation: -800 daPa <strong>and</strong> +600 daPa.<br />

Pressure change rate: Selectable in the set-up between 50, 150 <strong>and</strong> >250 daPa/s or automatic.<br />

Compliance: Range: 0.1 to 6.0 ml (numerical: 0.1 to 8.0 ml).<br />

Automatic, where pump speed, start <strong>and</strong> stop pressure can be userprogrammed in the set-up.<br />

<strong>AT235</strong>h: Auto <strong>and</strong> manual pump functions.<br />

<strong>AT235</strong>: Function test for use when the eardrum is intact.<br />

<strong>AT235</strong>h: Function tests for use with both intact <strong>and</strong> perforated eardrums.<br />

Atomatic reflex: Two independent user selectable protocols. Series of fixed intensities available.<br />

Automated intensity search functions available for threshold search <strong>and</strong> reflex growth indication.<br />

Free mixing of Ipsi <strong>and</strong> Contra.<br />

Manual reflex: Manual control of all stimuli. May also be used to redo part of automated test results.<br />

Reflex decay: Manual control, with stimulus duration of 10 sec. Ipsi or contralateral stimulation.<br />

Ipsilateral: Intensitiy up to 110dBHL. Frequency: 250, 500, 1000, 2000, 3000, 4000, WB, HP, LP noise<br />

Contralateral: Intensity up to 120dBHL. Frequency: 125 to 8000Hz, WB, LP, HP noise<br />

Audiometry: Intensity from -10 to 120dBHL. Frequency from 125Hz to 8000Hz<br />

1dB or 5dB steps.<br />

Internal memory for two ears. Each ear: 6 Ipsi <strong>and</strong> 6 Contra recordings. Each may have up to 6 stimuli.<br />

Also, there is memory for additional manual reflex recordings. (Total max. 78 reflexes per ear).<br />

Manual Audiometry.<br />

Automatic Audiometry according to ISO 8253-1 (Patient controlled Hughson-Westlake).<br />

Input/output for computer communication via USB. One mode allows an external PC to both monitor<br />

<strong>and</strong> control the instrument. The control actions can be followed on the display <strong>and</strong> operation panel.<br />

Online communication, where the measurement data are sent to an external PC can be selected.<br />

Built-in fast thermal printer with paper width: 112 mm.<br />

Interacoustics OtoAccess Database.<br />

IA-NOAH-Imp Module for interfacing to NOAH.<br />

UPS400 (Included) 100-240V.<br />

15VA, max. 45VA.<br />

(LxWxH): 36x26x10 cm / 14x10x4 inches. Weight: 2.8 kg / 6 lbs.<br />

Impedance st<strong>and</strong>ard: IEC 60645-5/ANSI S3.39, Type 2.<br />

Audiometer st<strong>and</strong>ard:<br />

IEC 60645-1/ANSI S.3.6, Type 4 Tone.<br />

Safety st<strong>and</strong>ard: IEC 60601-1, Class I, Type B.<br />

Medical CE-mark:<br />

Printer Option:<br />

Included Parts:<br />

Yes<br />

<strong>AT235</strong>/<strong>AT235</strong>h-xp is identical to the <strong>AT235</strong>/<strong>AT235</strong>h but has no built-in printer. Suitable for<br />

installations where computer connection takes care of printing.<br />

ATP-<strong>AT235</strong>u Universal Probe System with<br />

shoulder strap <strong>and</strong> wrist strap<br />

HBZ235u Single Contralateral Headset<br />

UPS400 External Switch Mode Power Supply<br />

Power Cable (110/220V, please specify)<br />

BET50 Box of 65 assorted Eartips<br />

TPR26 3 Rolls of Recording Paper<br />

PCR-<strong>AT235</strong> Dust Cover<br />

Operation manual CD<br />

Multilingual CE manual<br />

Other Middle Ear Analyzers:<br />

• MT10 H<strong>and</strong>held Tympanometer<br />

Audiometry <strong>and</strong> Middle Ear<br />

Analyzer in one:<br />

• AA220 Audio Traveller<br />

• AA222 Audio Traveller<br />

Hard shell carrying case<br />

Printout from <strong>AT235</strong><br />

Optional Parts:<br />

Sales <strong>and</strong> service in your area:<br />

Interacoustics A/S<br />

TDH39 Audiometric Headset<br />

EAR-Tone5A Insert Phones for Audiometry<br />

ACC25 Carrying Case<br />

CIR22 Contralateral Insert Phone<br />

APS3 Response switch<br />

Phone: +45 6371 3555 · Fax: +45 6371 3522<br />

E-mail: info@interacoustics.com<br />

DK-5610 Assens, Denmark<br />

Web: www.interacoustics.com<br />

CAT40 Calibration Unit 0.2-0.5-2.0-5.0 ml<br />

IES-2 Impedance Ear Simulator<br />

OtoAccess Database <strong>and</strong> diagnostic modules<br />

software<br />

IA-NOAH-Imp module<br />

Printout from <strong>AT235</strong>h<br />

Read more here:<br />

www.interacoustics.com/com/<strong>AT235</strong> or <strong>AT235</strong>h<br />

Interacoustics ®<br />

®<br />

leading diagnostic solutions<br />

83004703 - 4 - 10/2008

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!