www.stavoklima.eu<br />

<strong>Air</strong> <strong>curtain</strong><br />

Econ


<strong>Air</strong> <strong>curtain</strong> Econ is intended for wall or underceiling mounting. Standard dimensional range and simple functional<br />

solution of the unit determines this type for usage in individual shops in administrative centers, boutigues, restaurants,<br />

banks or hotels.<br />

In standard inbuilt electronic regulator Econ secures high comfort of service. Main advantage of these units is price availability,<br />

fast and easy installation, low noise level and used material and components of high quality incl. maintenace free<br />

electro motors. An adjustable blade for optimal air flow direction comes standard with every model.<br />

It is possible to deliver wide range of accessories to this unit, as thermostatic valves, outlet thermostats or electronically<br />

controlled electro heaters with inbuilt time delay and protection against overheating. Ambient models are available<br />

as well as water heated models with water temperature parametres max. 90°C/1,6Mpa and many alternatives of electric<br />

heaters.<br />

Technical data:<br />

Econ<br />

100<br />

S<br />

Econ<br />

150<br />

S<br />

Econ<br />

200<br />

S<br />

Econ<br />

100<br />

W<br />

*) heating capacity based on 18˚C air inlet temperature **) acoustic pressure dB(A) measured at a distance of 3m<br />

Econ<br />

150<br />

W<br />

Econ<br />

200<br />

W<br />

<strong>Air</strong> <strong>curtain</strong> length mm 1000 1500 2000 1000 1500 2000<br />

<strong>Air</strong> volume m 3 /h 1400 1750 2350 1220 1850 2265<br />

Heating capacity kW - - - 8,6 13,5 18,1<br />

80/60˚C kPa - - - 6,9 2,7 3,4<br />

I/hod - - - 360 576 756<br />

Heating capacity kW - - - 4,8 7,5 10,3<br />

60/40˚C kPa - - - 2,6 1,00 1,30<br />

I/hod - - - 180 288 432<br />

Unit voltage V 230 V 230 V 230 V 230 V 230 V 230 V<br />

W 115 184 230 115 184 230<br />

A 1 1,6 2 1 1,6 2<br />

Motor degree<br />

of protection<br />

IP 22 22 22 22 22 22<br />

Control Econ Econ Econ Econ Econ Econ<br />

Noise level dB (A)** 54 55 58 54 55 58<br />

Weight kg 18 23 29 22 29 37<br />

<strong>Air</strong> <strong>curtain</strong>´s connection with heat exchanger<br />

<strong>Air</strong> <strong>curtain</strong>´s connection with electro exchanger Heating medium connection 3/4"<br />

Technical data: Econ<br />

100<br />

E2,5<br />

230V<br />

01/09 Technical Modifications Reserved<br />

page 2<br />

Econ<br />

100<br />

E2,5<br />

Econ<br />

100<br />

E5<br />

Econ<br />

100<br />

E7,5<br />

Econ<br />

100<br />

E9<br />

Econ<br />

150<br />

E10<br />

Econ<br />

150<br />

E12,5<br />

Econ<br />

150<br />

E15<br />

Econ<br />

200<br />

E10<br />

Econ<br />

200<br />

E15<br />

Econ<br />

200<br />

E17,5<br />

<strong>Air</strong> <strong>curtain</strong> length mm 1000 1000 1000 1000 1000 1500 1500 1500 2000 2000 2000<br />

<strong>Air</strong> volume m3 /h 1400 1400 1400 1400 1400 1750 1750 1750 2300 2300 2300<br />

Heating capacity electric 2,5 2,5 5 7,5 9 10 12,5 15 10 15 17,5<br />

Grades of electric<br />

kW kW kW kW kW kW kW kW kW kW kW<br />

heater 1 1 2 2 2 2 2 2 2 2 2<br />

Unit voltage V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V<br />

El. data ventilátoru W 115 115 115 115 115 184 184 184 230 230 230<br />

A 1 1 1 1 1 1,6 1,6 1,6 2 2 2<br />

Motor degree<br />

of protection<br />

IP 22 22 22 22 22 22 22 22 22 22 22<br />

Control Econ Econ Econ Econ Econ Econ Econ Econ Econ Econ Econ<br />

Noise level dB (A)** 54 54 54 54 54 55 55 55 58 58 58<br />

Weight kg 22 22 22 22 22 29 29 29 37 37 37


Accessories for Econ air <strong>curtain</strong>s<br />

Valve: according to the customer´s request it is possible to deliver<br />

2-way or 3-way-valve. Control head of the valve can be either<br />

self-acting (thermostatic) or electrothermic. Electrothermic<br />

head of the valve must be connected into the electronic placed<br />

in the unit and it is necessary to connect the thermostat. All valves<br />

are delivered as loose – uninbuilt, due to space reasons.<br />

k v“*t allowed running allowed running allowed pressure<br />

2-way-valve value temperature pressure difference<br />

[°C] [bar] p [bar]<br />

DN 25 (1“) 2,5 120 10 0,25<br />

DN 32 (5/4“) 3,8 120 10 0,25<br />

DN 25 XXL (1“)* 4,3 120 16 0,20<br />

* high flow valve<br />

** for DN23, 32 valid for [K] 3.0; for DN25 XXL valid for [K] 6.0<br />

Room thermostat: 230V wall mounting, version<br />

TP1 or TP2 with a switch (delivered loose)<br />

picture – Thermostat.<br />

Control: Econ<br />

Control description: the control is intended for fan and heater<br />

regulation (water heated and also electric) with connection<br />

possibility of external elements (door contact, room or outlet<br />

thermostat). For electric versions is a part of the electronic<br />

in the unit a protection against heater overheating with an<br />

automatic fan delay.<br />

Dimensions: w. 71 x h. 71 x d. 25 [mm]<br />

The control is intended only for wall mounting. IP 20<br />

Econ control functions:<br />

Free potential door contact<br />

incl. adjustable delay<br />

of the unit<br />

Processor control of the<br />

unit against overheating<br />

of the electro heater<br />

Room thermostat, control<br />

via external remote contact<br />

standard<br />

standard<br />

standard<br />

Small control dimensions,<br />

wall mounting, ergonomical<br />

design<br />

Possibility of electrothermic<br />

valve control<br />

Chaining possibility<br />

in the system Master/Slave<br />

standard<br />

standard<br />

is not possible<br />

01/09 Technical Modifications Reserved<br />

page 3<br />

pressure loss<br />

flow quantity<br />

Door contact: 24 V, DKM or DKMG<br />

DKM - mechanical door contact<br />

DKMG - magnetical door contact<br />

Outlet thermostat:<br />

230V, mounting into the unit, the capillary is placed<br />

in the outlet space, the thermostat is delivered loose


Water heated air <strong>curtain</strong>s – diagram<br />

Water heated air <strong>curtain</strong>s – diagram<br />

L1<br />

L1<br />

N<br />

N<br />

Control ECON<br />

Control ECON<br />

PE<br />

PE<br />

10 x 1<br />

10 x 1<br />

Order key:<br />

Econ - 100 − W<br />

100;150; 200<br />

100 - unit length 1000mm<br />

150 - unit length 1500mm<br />

200 - unit length 2000mm<br />

FA1<br />

FA1<br />

3x2,5<br />

3x2,5<br />

W - heat exchanger 80/60°C event. 60/40°C<br />

S - ambient unit without heater<br />

E 2,5 / 230 V - electric heater 230V - 2,5kW; unit length 1m<br />

E 2,5 - electric heater 400V - 2,5kW; unit length 1m<br />

E 5 - electric heater 400V - 5kW; unit length 1m<br />

E 7,5 - electric heater 400V - 7,5kW; unit length 1m<br />

E 9 - electric heater 400V - 9kW; unit length 1m<br />

E 10 - electric heater 400V - 10kW; unit length 1,5 and 2m<br />

E 12,5 - electric heater 400V - 12,5kW; unit length 1,5m<br />

E 15 - electric heater 400V - 15kW; unit length 1,5 and 2m<br />

E 17,5 - electric heater 400V - 17,5kW; unit length 2m<br />

Accessories:<br />

� Flexible tubes<br />

� Thermostatic valve<br />

� Room thermostat<br />

� Variable outlet thermostat<br />

Representative:<br />

2 x 1<br />

2 x 1<br />

Door contact<br />

Door contact<br />

External contact,<br />

External thermostat contact,<br />

thermostat<br />

110,0 53,0<br />

Electric air <strong>curtain</strong>s – diagram<br />

Electric air <strong>curtain</strong>s – diagram<br />

L3<br />

L3<br />

R4,5<br />

20,5<br />

182,5 640 / 1140 / 1640<br />

182,5<br />

9,0<br />

L2<br />

L2<br />

L1<br />

L1<br />

Control ECON<br />

Control ECON<br />

N<br />

N<br />

PE<br />

PE<br />

WL3<br />

FA3<br />

FA3<br />

WL3 WL2<br />

WL2<br />

10 x 1<br />

10 x 1<br />

Tablet of cables and protection for water heated models<br />

FA1 1 X 10A/C WL1 3Cx 1,5 (2,5)<br />

FA2 See tablet. EO WL2 See tablet. EO<br />

FA3 See tablet. EO WL3 See tablet. EO<br />

Tablet of cables and protection for electric heated models (EO)<br />

Electric heater cable<br />

(WL2)<br />

circuit breaker<br />

(FA2)<br />

FA1<br />

FA1<br />

WL1<br />

WL1<br />

cable<br />

(WL3)<br />

170,0 29,5<br />

964,0 / 1464 / 1964 20,5<br />

293<br />

circuit breaker<br />

(FA3)<br />

2,5 kW / 230 V 3C x 4 1 x 16 A/B - -<br />

2,5 kW 5C x 4 3 x 16 A/B - -<br />

5 kW 5C x 4 3 x 16 A/B 5C x 4 3 x 16A/B<br />

7,5 kW 5C x 4 3 x 16 A/B 5C x 4 3 x 16A/B<br />

9 kW 5C x 2,5 3 x 10 A/B 5C x 2,5 3 x 10A/B<br />

10 kW 5C x 4 3 x 16 A/B 5C x 4 3 x 16A/B<br />

12,5 kW 5C x 4 3 x 16 A/B 5C x 4 3 x 16A/B<br />

15 kW 5C x 4 3 x 16 A/B 5C x 4 3 x 16A/B<br />

17,5 kW 5C x 4 3 x 16 A/B 5C x 6 3 x 25A/B<br />

Wall suspension<br />

FA2<br />

FA2<br />

2 x 1<br />

2 x 1<br />

External contact,<br />

External thermostat contact,<br />

thermostat<br />

Underceiling suspension<br />

Door contact<br />

Door contact<br />

228<br />

246<br />

239,0<br />

34<br />

239<br />

STAVOKLIMA V.O.S.<br />

HORNÍ 22 • CZ-370 04 • ČESKÉ BUDĚJOVICE<br />

tel.: +420 387 001 946, +420 387 001 931<br />

fax: +420 387 001 950<br />

e-mail: info@stavoklima.<strong>cz</strong><br />

http://www.stavoklima.eu<br />

Econ /01/09-AN