Air curtain - Stavoklima.cz
Air curtain - Stavoklima.cz
Air curtain - Stavoklima.cz
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
www.stavoklima.eu<br />
<strong>Air</strong> <strong>curtain</strong><br />
Econ
<strong>Air</strong> <strong>curtain</strong> Econ is intended for wall or underceiling mounting. Standard dimensional range and simple functional<br />
solution of the unit determines this type for usage in individual shops in administrative centers, boutigues, restaurants,<br />
banks or hotels.<br />
In standard inbuilt electronic regulator Econ secures high comfort of service. Main advantage of these units is price availability,<br />
fast and easy installation, low noise level and used material and components of high quality incl. maintenace free<br />
electro motors. An adjustable blade for optimal air flow direction comes standard with every model.<br />
It is possible to deliver wide range of accessories to this unit, as thermostatic valves, outlet thermostats or electronically<br />
controlled electro heaters with inbuilt time delay and protection against overheating. Ambient models are available<br />
as well as water heated models with water temperature parametres max. 90°C/1,6Mpa and many alternatives of electric<br />
heaters.<br />
Technical data:<br />
Econ<br />
100<br />
S<br />
Econ<br />
150<br />
S<br />
Econ<br />
200<br />
S<br />
Econ<br />
100<br />
W<br />
*) heating capacity based on 18˚C air inlet temperature **) acoustic pressure dB(A) measured at a distance of 3m<br />
Econ<br />
150<br />
W<br />
Econ<br />
200<br />
W<br />
<strong>Air</strong> <strong>curtain</strong> length mm 1000 1500 2000 1000 1500 2000<br />
<strong>Air</strong> volume m 3 /h 1400 1750 2350 1220 1850 2265<br />
Heating capacity kW - - - 8,6 13,5 18,1<br />
80/60˚C kPa - - - 6,9 2,7 3,4<br />
I/hod - - - 360 576 756<br />
Heating capacity kW - - - 4,8 7,5 10,3<br />
60/40˚C kPa - - - 2,6 1,00 1,30<br />
I/hod - - - 180 288 432<br />
Unit voltage V 230 V 230 V 230 V 230 V 230 V 230 V<br />
W 115 184 230 115 184 230<br />
A 1 1,6 2 1 1,6 2<br />
Motor degree<br />
of protection<br />
IP 22 22 22 22 22 22<br />
Control Econ Econ Econ Econ Econ Econ<br />
Noise level dB (A)** 54 55 58 54 55 58<br />
Weight kg 18 23 29 22 29 37<br />
<strong>Air</strong> <strong>curtain</strong>´s connection with heat exchanger<br />
<strong>Air</strong> <strong>curtain</strong>´s connection with electro exchanger Heating medium connection 3/4"<br />
Technical data: Econ<br />
100<br />
E2,5<br />
230V<br />
01/09 Technical Modifications Reserved<br />
page 2<br />
Econ<br />
100<br />
E2,5<br />
Econ<br />
100<br />
E5<br />
Econ<br />
100<br />
E7,5<br />
Econ<br />
100<br />
E9<br />
Econ<br />
150<br />
E10<br />
Econ<br />
150<br />
E12,5<br />
Econ<br />
150<br />
E15<br />
Econ<br />
200<br />
E10<br />
Econ<br />
200<br />
E15<br />
Econ<br />
200<br />
E17,5<br />
<strong>Air</strong> <strong>curtain</strong> length mm 1000 1000 1000 1000 1000 1500 1500 1500 2000 2000 2000<br />
<strong>Air</strong> volume m3 /h 1400 1400 1400 1400 1400 1750 1750 1750 2300 2300 2300<br />
Heating capacity electric 2,5 2,5 5 7,5 9 10 12,5 15 10 15 17,5<br />
Grades of electric<br />
kW kW kW kW kW kW kW kW kW kW kW<br />
heater 1 1 2 2 2 2 2 2 2 2 2<br />
Unit voltage V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V<br />
El. data ventilátoru W 115 115 115 115 115 184 184 184 230 230 230<br />
A 1 1 1 1 1 1,6 1,6 1,6 2 2 2<br />
Motor degree<br />
of protection<br />
IP 22 22 22 22 22 22 22 22 22 22 22<br />
Control Econ Econ Econ Econ Econ Econ Econ Econ Econ Econ Econ<br />
Noise level dB (A)** 54 54 54 54 54 55 55 55 58 58 58<br />
Weight kg 22 22 22 22 22 29 29 29 37 37 37
Accessories for Econ air <strong>curtain</strong>s<br />
Valve: according to the customer´s request it is possible to deliver<br />
2-way or 3-way-valve. Control head of the valve can be either<br />
self-acting (thermostatic) or electrothermic. Electrothermic<br />
head of the valve must be connected into the electronic placed<br />
in the unit and it is necessary to connect the thermostat. All valves<br />
are delivered as loose – uninbuilt, due to space reasons.<br />
k v“*t allowed running allowed running allowed pressure<br />
2-way-valve value temperature pressure difference<br />
[°C] [bar] p [bar]<br />
DN 25 (1“) 2,5 120 10 0,25<br />
DN 32 (5/4“) 3,8 120 10 0,25<br />
DN 25 XXL (1“)* 4,3 120 16 0,20<br />
* high flow valve<br />
** for DN23, 32 valid for [K] 3.0; for DN25 XXL valid for [K] 6.0<br />
Room thermostat: 230V wall mounting, version<br />
TP1 or TP2 with a switch (delivered loose)<br />
picture – Thermostat.<br />
Control: Econ<br />
Control description: the control is intended for fan and heater<br />
regulation (water heated and also electric) with connection<br />
possibility of external elements (door contact, room or outlet<br />
thermostat). For electric versions is a part of the electronic<br />
in the unit a protection against heater overheating with an<br />
automatic fan delay.<br />
Dimensions: w. 71 x h. 71 x d. 25 [mm]<br />
The control is intended only for wall mounting. IP 20<br />
Econ control functions:<br />
Free potential door contact<br />
incl. adjustable delay<br />
of the unit<br />
Processor control of the<br />
unit against overheating<br />
of the electro heater<br />
Room thermostat, control<br />
via external remote contact<br />
standard<br />
standard<br />
standard<br />
Small control dimensions,<br />
wall mounting, ergonomical<br />
design<br />
Possibility of electrothermic<br />
valve control<br />
Chaining possibility<br />
in the system Master/Slave<br />
standard<br />
standard<br />
is not possible<br />
01/09 Technical Modifications Reserved<br />
page 3<br />
pressure loss<br />
flow quantity<br />
Door contact: 24 V, DKM or DKMG<br />
DKM - mechanical door contact<br />
DKMG - magnetical door contact<br />
Outlet thermostat:<br />
230V, mounting into the unit, the capillary is placed<br />
in the outlet space, the thermostat is delivered loose
Water heated air <strong>curtain</strong>s – diagram<br />
Water heated air <strong>curtain</strong>s – diagram<br />
L1<br />
L1<br />
N<br />
N<br />
Control ECON<br />
Control ECON<br />
PE<br />
PE<br />
10 x 1<br />
10 x 1<br />
Order key:<br />
Econ - 100 − W<br />
100;150; 200<br />
100 - unit length 1000mm<br />
150 - unit length 1500mm<br />
200 - unit length 2000mm<br />
FA1<br />
FA1<br />
3x2,5<br />
3x2,5<br />
W - heat exchanger 80/60°C event. 60/40°C<br />
S - ambient unit without heater<br />
E 2,5 / 230 V - electric heater 230V - 2,5kW; unit length 1m<br />
E 2,5 - electric heater 400V - 2,5kW; unit length 1m<br />
E 5 - electric heater 400V - 5kW; unit length 1m<br />
E 7,5 - electric heater 400V - 7,5kW; unit length 1m<br />
E 9 - electric heater 400V - 9kW; unit length 1m<br />
E 10 - electric heater 400V - 10kW; unit length 1,5 and 2m<br />
E 12,5 - electric heater 400V - 12,5kW; unit length 1,5m<br />
E 15 - electric heater 400V - 15kW; unit length 1,5 and 2m<br />
E 17,5 - electric heater 400V - 17,5kW; unit length 2m<br />
Accessories:<br />
� Flexible tubes<br />
� Thermostatic valve<br />
� Room thermostat<br />
� Variable outlet thermostat<br />
Representative:<br />
2 x 1<br />
2 x 1<br />
Door contact<br />
Door contact<br />
External contact,<br />
External thermostat contact,<br />
thermostat<br />
110,0 53,0<br />
Electric air <strong>curtain</strong>s – diagram<br />
Electric air <strong>curtain</strong>s – diagram<br />
L3<br />
L3<br />
R4,5<br />
20,5<br />
182,5 640 / 1140 / 1640<br />
182,5<br />
9,0<br />
L2<br />
L2<br />
L1<br />
L1<br />
Control ECON<br />
Control ECON<br />
N<br />
N<br />
PE<br />
PE<br />
WL3<br />
FA3<br />
FA3<br />
WL3 WL2<br />
WL2<br />
10 x 1<br />
10 x 1<br />
Tablet of cables and protection for water heated models<br />
FA1 1 X 10A/C WL1 3Cx 1,5 (2,5)<br />
FA2 See tablet. EO WL2 See tablet. EO<br />
FA3 See tablet. EO WL3 See tablet. EO<br />
Tablet of cables and protection for electric heated models (EO)<br />
Electric heater cable<br />
(WL2)<br />
circuit breaker<br />
(FA2)<br />
FA1<br />
FA1<br />
WL1<br />
WL1<br />
cable<br />
(WL3)<br />
170,0 29,5<br />
964,0 / 1464 / 1964 20,5<br />
293<br />
circuit breaker<br />
(FA3)<br />
2,5 kW / 230 V 3C x 4 1 x 16 A/B - -<br />
2,5 kW 5C x 4 3 x 16 A/B - -<br />
5 kW 5C x 4 3 x 16 A/B 5C x 4 3 x 16A/B<br />
7,5 kW 5C x 4 3 x 16 A/B 5C x 4 3 x 16A/B<br />
9 kW 5C x 2,5 3 x 10 A/B 5C x 2,5 3 x 10A/B<br />
10 kW 5C x 4 3 x 16 A/B 5C x 4 3 x 16A/B<br />
12,5 kW 5C x 4 3 x 16 A/B 5C x 4 3 x 16A/B<br />
15 kW 5C x 4 3 x 16 A/B 5C x 4 3 x 16A/B<br />
17,5 kW 5C x 4 3 x 16 A/B 5C x 6 3 x 25A/B<br />
Wall suspension<br />
FA2<br />
FA2<br />
2 x 1<br />
2 x 1<br />
External contact,<br />
External thermostat contact,<br />
thermostat<br />
Underceiling suspension<br />
Door contact<br />
Door contact<br />
228<br />
246<br />
239,0<br />
34<br />
239<br />
STAVOKLIMA V.O.S.<br />
HORNÍ 22 • CZ-370 04 • ČESKÉ BUDĚJOVICE<br />
tel.: +420 387 001 946, +420 387 001 931<br />
fax: +420 387 001 950<br />
e-mail: info@stavoklima.<strong>cz</strong><br />
http://www.stavoklima.eu<br />
Econ /01/09-AN