ECLIPSE TM DRYER OPERATION<br />
5<br />
Dry air exits dryer for use<br />
4<br />
<strong>ZEKS</strong> particulate afterfilter protects<br />
pneumatic tools and equipment<br />
7<br />
Purge air flows countercurrent<br />
to regenerate the<br />
desiccant media in the<br />
offline (regenerating)<br />
tower, assisted by the<br />
heat-of-adsorption<br />
6<br />
A portion of<br />
dry purge air<br />
is directed to<br />
the offline<br />
tower for<br />
regeneration<br />
8<br />
Moisture is exhausted to<br />
atmosphere through muffler 2<br />
<strong>ZEKS</strong> coalescing prefilter<br />
protects dryer<br />
ZHAmodels use a small<br />
amount of dry, heated compressed<br />
air to regenerate the offline tower.<br />
1<br />
Moist compressed air enters dryer<br />
2<br />
<strong>ZEKS</strong> coalescing prefilter<br />
protects dryer<br />
3<br />
Inlet flow valves automatically<br />
direct moist compressed air<br />
through online (drying) tower.<br />
As air passes over the<br />
desiccant, moisture is<br />
adsorbed by the media<br />
3<br />
Inlet flow valves automatically<br />
direct moist compressed air through<br />
online (drying) tower. As air passes over<br />
the desiccant, the moisture is adsorbed<br />
by the desiccant. Heat is generated by<br />
this removal of the moisture from the air<br />
(Heat-of-Adsorption)<br />
1<br />
Moist compressed air<br />
enters dryer<br />
1<br />
Moist compressed air enters dryer<br />
2<br />
<strong>ZEKS</strong> coalescing prefilter<br />
protects dryer<br />
3<br />
Inlet flow valves automatically<br />
direct moist compressed air through<br />
online (drying) tower. As air passes over the<br />
desiccant, moisture is adsorbed by the media<br />
HEATER<br />
4<br />
<strong>ZEKS</strong> particulate afterfilter protects<br />
pneumatic tools and equipment<br />
HEATER<br />
4<br />
<strong>ZEKS</strong> particulate afterfilter protects<br />
pneumatic tools and equipment<br />
8<br />
Moisture is exhausted to<br />
atmosphere through muffler<br />
7<br />
Purge air flows counter-current to<br />
regenerate the desiccant media in<br />
the offline (regenerating) tower<br />
6<br />
Purge air is generated by blower and<br />
directed through heater then into the<br />
offline tower for regeneration<br />
5<br />
Dry air exits dryer for use<br />
ZPAmodels use a portion of dry,<br />
unheated compressed air to regenerate<br />
the offline tower.<br />
8<br />
Moisture is exhausted to<br />
atmosphere through muffler<br />
7<br />
Purge air flows counter-current to<br />
regenerate the desiccant media in<br />
the offline (regenerating) tower<br />
6<br />
A portion of dry purge air is directed<br />
through heater then into the offline<br />
tower for regeneration<br />
5<br />
Dry air exits dryer for use<br />
ZBAmodels use air from a dedicated<br />
blower that passes through a heater to<br />
regenerate the offline tower.