RACK & ACCESSORY GUIDE - Exide Technologies
RACK & ACCESSORY GUIDE - Exide Technologies
RACK & ACCESSORY GUIDE - Exide Technologies
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
MARATHON M12V40(F) ACCESSORIES AND <strong>RACK</strong>S<br />
The sketch shown below is for connector<br />
selection only; it does not represent a typical RATE<br />
CABLE KITS<br />
PART NUMBER<br />
KIT CONTENTS<br />
system layout. LOW K17-CABLMSB-001 (qty 1) #2 AWG, 36" long, 1 hole lug<br />
(½”)<br />
MEDIUM K17-CABLMSB-001 (qty 1) #2 AWG, 36" long, 1 hole lug<br />
CROSS-AISLE CABLES ARE NOT PROVIDED<br />
1 2<br />
3<br />
5<br />
4<br />
6<br />
(½”)<br />
I & O MANUAL<br />
Z99-MARSPT<br />
BATTERY HANDLE<br />
K01-M12V40<br />
TERMINAL PLATE KIT<br />
K17-MSBTP B<br />
CABLE LUG INSULATOR<br />
L14-LUGBOOT C<br />
COPPER CONNECTOR BARS<br />
LOW<br />
MEDIUM<br />
CONN # RATE A RATE A<br />
1 L03-106397-026 L03-106397-026<br />
2* L03-109210-041 L03-109210-041<br />
3 L03-109210-001 L03-109210-001<br />
4 L03-106397-007 L03-106397-007<br />
5 L03-106397-003 L03-106397-003<br />
6 L03-106397-038 L03-106397-038<br />
* Standard inter-unit connector for racks.<br />
CENTER TO CENTER LENGTH<br />
CONN # INCHES MILLIMETERS<br />
1 7.00 177.8<br />
2 9.38 238.3<br />
3 2.12 53.8<br />
4 4.91 124.7<br />
5 2.62 66.5<br />
6 11.63 295.4<br />
NON-SEISMIC (ZONE 0) <strong>RACK</strong>S<br />
DESCRIPTION<br />
PART NUMBER MAX UNITS<br />
1-TIER, 1-ROW D<br />
GNB114S170Z0<br />
GNB115S170Z0<br />
GNB116S170Z0<br />
4<br />
5<br />
6<br />
2-TIER, 1-ROW D<br />
3-TIER, 1-ROW D<br />
4-TIER, 1-ROW D GNB214S170Z0<br />
GNB215S170Z0<br />
GNB216S170Z0<br />
GNB314S170Z0<br />
GNB315S170Z0<br />
GNB316S170Z0<br />
GNB414S170Z0<br />
GNB415S170Z0<br />
8<br />
10<br />
12<br />
12<br />
15<br />
18<br />
16<br />
20<br />
5-TIER, 1-ROW D GNB416S170Z0<br />
GNB514S170Z0<br />
GNB515S170Z0<br />
GNB516S170Z0<br />
24<br />
20<br />
25<br />
30<br />
CONNECTOR BAR COVERS<br />
CONN #<br />
PART NUMBER<br />
1<br />
L14-401128<br />
2<br />
L14-401129<br />
3<br />
L14-401126<br />
4<br />
L14-401127<br />
5<br />
L14-401126<br />
6<br />
L14-401130<br />
CELL NUMERALS & GREASE<br />
# UNITS<br />
PART NUMBER<br />
A Low rate = 180+ minutes to 1.75 VPC<br />
1-30 K17-418291S<br />
Medium rate = 60-179 minutes to 1.75 VPC<br />
31-60<br />
K17-418292S<br />
B Terminal plate will accept two cables.<br />
61-120<br />
K17-418293S<br />
C Lugboot will accept one cable.<br />
121-150<br />
K17-418294S<br />
D This rack style is available in a seismic (Zone 1 - 4)<br />
151-180 K17-418295S<br />
version; use -Z4 suffix in lieu of -Z0 suffix.<br />
181-210<br />
211-240<br />
K17-418296S<br />
K17-418299S<br />
19