New developments and accessories for the CoMeT test set-up<br />
<strong>bedea</strong> – <strong>Rosenberger</strong><br />
CoMeT- newsletter - 01/2003 - S. 2<br />
There are different improvements, complements and accessories to the CoMeT test set-up<br />
about which we want to inform you more detailed.<br />
Due to the modular construction, the different components or complements may be assembled<br />
without any restriction.<br />
1 Stretching device<br />
When measuring the screening attenuation in the tube, the cable under test shall be centred in<br />
the middle of the tube to avoid changes of the characteristic impedance in the second system.<br />
This may be achieved by maintain the measurement with vertical mounted tube but with<br />
incumber handling<br />
With the stretching device, one can keep the sample centred in the horizontal mounted tube.<br />
Care should be taken not to apply to high stretching forces to the screen of the sample because<br />
this will change its characteristics.<br />
The stretching device is equipped with a torque wrench which allows to control the stretching<br />
force.<br />
Figure 2 – Stretching device for the CoMeT test set-up<br />
Supply schedule: Stretching device, 1 set of contact slices, 2,2 to 9,8 mm, torque wrench<br />
An investigation of the influence of stretching forces to the test results of screening<br />
measurements may be ordered from <strong>bedea</strong>.<br />
2 Extension set for 10mm to 15mm diameter<br />
Measuring the screening attenuation and the transfer impedance up to 15mm diameter over<br />
screen with the CoMeT 40/2 (standard application up to 9,8mm over screen).<br />
The additional reflection due to the enlarged case shall be taken into account when evaluating<br />
the test results.<br />
An investigation of the influence of additional reflections to the test results of screening<br />
measurements may be ordered from <strong>bedea</strong>.<br />
Supply schedule: Enlarged contact case, contact slices from 9,8mm to 14,8 mm.<br />
<strong>bedea</strong> <strong>Berkenhoff</strong>&<strong>Drebes</strong> <strong>GmbH</strong>, Postfach 1140, D-35607 Asslar, Germany, bmund@<strong>bedea</strong>.com