SUB-BASE<br />

The Sub-Base must be dry, clean, smooth & level BS 8204 SR1 (3mm deviation over 2 metre straight<br />

edge), free of nibs or loose material, and constructed to withstand design loads.<br />

Note:<br />

The performance of the System <strong>28</strong> will be adversely affected if it is installed over an uneven<br />

subfloor. Therefore we cannot guarantee the performance if fitted outside the above<br />

recommendations.<br />

VAPOUR BARRIER<br />

A vapour barrier, such as minimum 1200 gauge polythene sheeting, should be installed over all ground<br />

level slabs and new concrete bases above ground level, Joints shall be lapped a minimum of 150mm,<br />

and should be taped and sealed with waterproof adhesive tape, with edges upturned to the same height<br />

as the plywood overlay board at all perimeter walls.<br />

5 – Positioning Perimeter<br />

PERIMETER EDGE DETAIL<br />

“System <strong>28</strong>” sports boards, as in common with other wood based products; attract moisture, resulting in<br />

expansion or contraction when installed in a new building or a building undergoing renovation. We<br />

would recommend for a sports hall up to approx 800 m² that a minimum gap of 20mm is left at all<br />

perimeter and abutments. For sports halls in excess of 800 m² contact <strong>Gerflor</strong> Technical Department.<br />

The expansion gap is then filled with “System <strong>28</strong>” Perimeter Foam (20mm x 50mm) and then trimmed to<br />

finished board level. The <strong>Gerflor</strong> <strong>Taraflex</strong> Sport M Plus or <strong>Taraflex</strong> Surface is then fitted in the normal<br />

manner to within 10mm of the perimeter wall. Skirting/rebound boards should be fitted after the<br />

installation of the floor covering. Any skirting/rebound boards should be wall fixed only 1mm proud of<br />

the surface of the floor.<br />

<strong>Gerflor</strong> Ltd (Technical Dept), Wedgnock Lane, Warwick, CV34 5AP, United Kingdom<br />