Fault Isolation Procedures<br />

Power Up Sequence Test, continued<br />

Step H Procedure Condition Action<br />

1. Key off.<br />

2. Disconnect Shift Control 30-way<br />

connector.<br />

3. Key on.<br />

4. Measure voltage between<br />

Shift Control 30-way pins<br />

C1 and J3.<br />

If voltage is within 1 volt of<br />

battery voltage<br />

Replace Shift Control. Go<br />

Step V.<br />

to<br />

If voltage is outside of range Go to Step I.<br />

VOLTS<br />

V COM A<br />

K<br />

J<br />

H<br />

G<br />

F<br />

E<br />

D<br />

C<br />

B<br />

A<br />

3 2 1<br />

2-7