RTU560G Series RTU560G Series CMU & Modules
RTU560G Series RTU560G Series CMU & Modules
RTU560G Series RTU560G Series CMU & Modules
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>RTU560G</strong> <strong>Series</strong><br />
<strong>CMU</strong> & <strong>Modules</strong><br />
1KGT 150 648 V1.02<br />
© ABB Group<br />
March 4, 2012 | Slide 1
<strong>Modules</strong><br />
Contents<br />
<strong>RTU560G</strong> DIN rail solutions<br />
<strong>CMU</strong>s<br />
I/Os<br />
Communication modules<br />
Auxiliary<br />
© ABB Group<br />
March 4, 2012 | Slide 2
<strong>Modules</strong><br />
RTU560/RTU211 DIN rail solution<br />
Technical data<br />
RTU560 for DIN rail<br />
Technical data<br />
RTU211 for DIN rail<br />
<strong>CMU</strong>s<br />
I/Os<br />
Communication<br />
modules<br />
Auxiliary<br />
560CMG10<br />
560CIG10<br />
Serial interfaces 3<br />
Ethernet 10/100 BaseT 1<br />
Integrated I/Os<br />
16 binary inputs<br />
8 binary outputs<br />
8 analog inputs (mA)<br />
Extension<br />
I/O modules<br />
Dimensions<br />
W x H x D<br />
Binary inputs/outputs<br />
Analogue inputs/outputs<br />
Direct analog inputs<br />
Optional: fault current detection<br />
204 x 105 x 55 mm 230 x 150 x 84 mm<br />
© ABB Group<br />
March 4, 2012 | Slide 3
<strong>Modules</strong><br />
RTU560/RTU211 DIN rail solution<br />
Technical data<br />
RTU560 for DIN rail<br />
Technical data<br />
RTU211 for DIN rail<br />
<strong>CMU</strong>s<br />
I/Os<br />
Communication<br />
modules<br />
Auxiliary<br />
23CM61<br />
DIN rail RTU211<br />
Serial interfaces 1/4 3<br />
Ethernet 10/100<br />
BaseT<br />
Integrated I/Os<br />
0 1<br />
16 binary inputs<br />
8 binary outputs<br />
560<strong>CMU</strong>01<br />
Up to 4 of the following modules:<br />
16 binary inputs<br />
8 binary outputs<br />
6 analog inputs (mA)<br />
2 analog outputs<br />
6 temperature sensors<br />
Extension<br />
I/O modules<br />
Binary inputs/outputs<br />
Analog inputs/outputs<br />
Binary inputs/outputs<br />
Analog inputs/outputs<br />
Direct analog inputs<br />
Optional: Fault current detection<br />
Dimensions<br />
W x H x D<br />
(290 – 400) x 116 x 81 mm (181 – 741) x 116 x 81 mm<br />
Depending on integrated I/Os<br />
© ABB Group<br />
March 4, 2012 | Slide 4
<strong>Modules</strong><br />
RTU560/RTU211 DIN rail solution<br />
Technical data<br />
RTU560 for DIN rail<br />
Technical data<br />
RTU211 for DIN rail<br />
<strong>CMU</strong>s<br />
I/Os<br />
Communication<br />
modules<br />
Auxiliary<br />
23CM61<br />
512 kByte flash memory<br />
256 kByte RAM<br />
4 x RS232 ports<br />
RP570 communication protocols<br />
IEC 60870-5-101 or DNP3<br />
communication protocols<br />
Built-in “Local Automation Function”<br />
(LAF)<br />
Monitoring of system power<br />
Integrated alarm relay<br />
16 binary inputs<br />
8 binary outputs<br />
6 analog inputs<br />
1 out of n check<br />
© ABB Group<br />
March 4, 2012 | Slide 5
<strong>Modules</strong><br />
RTU560/RTU211 DIN rail solution<br />
Technical data<br />
RTU560 for DIN rail<br />
Technical data<br />
RTU211 for DIN rail<br />
<strong>CMU</strong>s<br />
I/Os<br />
Communication<br />
modules<br />
Auxiliary<br />
RTU211 based on 560<strong>CMU</strong>01<br />
560<strong>CMU</strong>01<br />
<br />
<br />
3 serial interfaces<br />
1 ethernet interface<br />
Up to 4 of the following I/O modules:<br />
<br />
<br />
<br />
<br />
<br />
16 binary inputs<br />
8 binary outputs<br />
6 analog inputs (mA)<br />
2 analog outputs<br />
6 temperature sensors<br />
560PSU10<br />
<br />
Total output of approx. 38 W, split to:<br />
+ 5 V DC and 1 A = 5 Watt<br />
+ 15 V DC and 0.5 A = 7.5 Watt<br />
15 V DC and 0.5 A = 7.5 Watt<br />
+ 18 V DC and 1A = 18 W<br />
© ABB Group<br />
March 4, 2012 | Slide 6
<strong>Modules</strong><br />
RTU560/RTU211 DIN rail solution<br />
Technical data<br />
RTU560 for DIN rail<br />
Technical data<br />
RTU211 for DIN rail<br />
Binary input Binary output Analog input Analog output<br />
23BI61<br />
23BO62/63<br />
23AI60<br />
23AO60<br />
<strong>CMU</strong>s 16 inputs 24/ 48/ 60 VDC 3A @ 110 VDC / 3A Analog inputs mA DC Analog output mA DC<br />
I/Os<br />
Communication<br />
modules<br />
Auxiliary<br />
23BE40<br />
16 inputs 110/ 220/250 VDC<br />
23BA40<br />
50 VA (L/R=40ms) @ 220 VDC / 8A<br />
560CVT02<br />
Analog inputs A/V AC<br />
23BE50<br />
64 inputs 24/ 48/ 60 VDC<br />
560CVT10<br />
Analog inputs<br />
© ABB Group<br />
March 4, 2012 | Slide 7
<strong>Modules</strong><br />
RTU560/RTU211 DIN rail solution<br />
Technical data<br />
RTU560 for DIN rail<br />
Technical data<br />
RTU211 for DIN rail<br />
<strong>CMU</strong>s<br />
I/Os<br />
Communication<br />
modules<br />
Auxiliary<br />
Binary input 23BI61<br />
16 binary inputs for single or double<br />
indication, digital measurands,<br />
pulse counter<br />
R0001: 2448 VDC<br />
R0002: 60110 VDC<br />
Grouped with common return per 8<br />
inputs<br />
One LED per input<br />
1 ms time resolution<br />
Length 105 mm<br />
Housing should be ordered<br />
separately<br />
© ABB Group<br />
March 4, 2012 | Slide 8
<strong>Modules</strong><br />
RTU560/RTU211 DIN rail solution<br />
Technical data<br />
RTU560 for DIN rail<br />
Technical data<br />
RTU211 for DIN rail<br />
<strong>CMU</strong>s<br />
I/Os<br />
Communication<br />
modules<br />
Auxiliary<br />
Direct process-interface 23BE40<br />
16 binary input channels<br />
Input Voltage<br />
110 VDC: 23BE40 R0011<br />
220 VDC: 23BE40 R0012<br />
Inputs without common<br />
return<br />
Galvanic insulation by optocouplers<br />
Input current 1,5 mA (chopped)<br />
Oxide film break function for 8<br />
inputs<br />
LEDs for signalization of input<br />
channels<br />
Power supply: 24 Vdc<br />
© ABB Group<br />
March 4, 2012 | Slide 9
<strong>Modules</strong><br />
RTU560/RTU211 DIN rail solution<br />
Technical data<br />
RTU560 for DIN rail<br />
Technical data<br />
RTU211 for DIN rail<br />
<strong>CMU</strong>s<br />
I/Os<br />
Communication<br />
modules<br />
Auxiliary<br />
64 binary input module 23BE50<br />
64 binary inputs<br />
Input range: 2460 VDC<br />
Input functions as 23BE23<br />
Groups with common return per 16<br />
inputs<br />
Galvanic insulation by optical<br />
couplers<br />
LEDs for signalization of each input<br />
channel<br />
Power supply: 24 VDC<br />
Usable without additional terminals<br />
© ABB Group<br />
March 4, 2012 | Slide 10
<strong>Modules</strong><br />
RTU560/RTU211 DIN rail solution<br />
Technical data<br />
RTU560 for DIN rail<br />
Technical data<br />
RTU211 for DIN rail<br />
<strong>CMU</strong>s<br />
I/Os<br />
Communication<br />
modules<br />
Auxiliary<br />
Binary output 23BO62<br />
8 binary relay outputs for 1, 1,5 or 2<br />
pole commands<br />
Isolated outputs<br />
One LED per output<br />
High switching capacity:<br />
3A @ 110 VDC<br />
Continuous current: 3A<br />
Length 140 mm<br />
Housing should be ordered<br />
separately<br />
© ABB Group<br />
March 4, 2012 | Slide 11
<strong>Modules</strong><br />
RTU560/RTU211 DIN rail solution<br />
Technical data<br />
RTU560 for DIN rail<br />
Technical data<br />
RTU211 for DIN rail<br />
<strong>CMU</strong>s<br />
I/Os<br />
Communication<br />
modules<br />
Auxiliary<br />
1 out of n check 23BO63<br />
1 out of n supervision in<br />
combination with 23BO62<br />
High switching capacity up to 110<br />
VDC, 3 A<br />
Length 70 mm<br />
Housing should be ordered<br />
separately<br />
© ABB Group<br />
March 4, 2012 | Slide 12
<strong>Modules</strong><br />
RTU560/RTU211 DIN rail solution<br />
Technical data<br />
RTU560 for DIN rail<br />
Technical data<br />
RTU211 for DIN rail<br />
<strong>CMU</strong>s<br />
I/Os<br />
Communication<br />
modules<br />
Auxiliary<br />
Direct process-interface 23BA40<br />
16 binary relay output channels<br />
Outputs without common return<br />
(23BA40 R0011)<br />
Galvanic insulation by relays<br />
Switching voltage<br />
max. 250 VDC/AC<br />
Switching capacity:<br />
50 VA (L/R=40ms) @ 220 VDC<br />
Continuous current: 8A<br />
© ABB Group<br />
March 4, 2012 | Slide 13
<strong>Modules</strong><br />
RTU560/RTU211 DIN rail solution<br />
Technical data<br />
RTU560 for DIN rail<br />
Technical data<br />
RTU211 for DIN rail<br />
<strong>CMU</strong>s<br />
I/Os<br />
Communication<br />
modules<br />
Auxiliary<br />
Analog input 23AI60<br />
6 analog inputs<br />
Resolution: 11 bit +sign<br />
Accuracy class: 0,25<br />
Ranges: ± 5mA, ± 10 mA,<br />
+20 mA, 420 mA, ± VDC, ±<br />
10VDC<br />
Length: 70 mm<br />
Housing should be ordered<br />
separately<br />
© ABB Group<br />
March 4, 2012 | Slide 14
<strong>Modules</strong><br />
RTU560/RTU211 DIN rail solution<br />
Technical data<br />
RTU560 for DIN rail<br />
Technical data<br />
RTU211 for DIN rail<br />
<strong>CMU</strong>s<br />
I/Os<br />
Communication<br />
modules<br />
Auxiliary<br />
Direct transducer interface 560CVT02<br />
3 voltage inputs 110 VAC<br />
110 VAC: 560CVT02 R000x<br />
(for measurement with voltage<br />
transformers)<br />
230 VAC: 560CVT02 R001x<br />
(for direct voltage measurement at<br />
the low voltage side)<br />
3 Current Inputs<br />
1A: 560CVT02 R00x1<br />
5A: 560CVT02 R00x5<br />
Accuracy: 0,2%<br />
Calculated values:<br />
Active, reactive, apparent power<br />
Active, reactive energy<br />
Power factor<br />
Frequency<br />
Harmonic distortion (THD)<br />
Integrated in RTU560 engineering<br />
© ABB Group<br />
March 4, 2012 | Slide 15
<strong>Modules</strong><br />
RTU560/RTU211 DIN rail solution<br />
Technical data<br />
RTU560 for DIN rail<br />
Technical data<br />
RTU211 for DIN rail<br />
<strong>CMU</strong>s R0011: 1A<br />
I/Os<br />
Communication<br />
modules<br />
Auxiliary<br />
Over Current Detection<br />
Saturation<br />
Phase x Current<br />
OCx_FV<br />
Over Current detected<br />
Time<br />
Direct transducer interface 560CVT10<br />
3 current inputs<br />
<br />
R0015: 5A<br />
3 voltage inputs max. 300V<br />
Accuracy up to 0.2%<br />
Low input burden<br />
<br />
<br />
Voltage 0.15VA at 300 V<br />
Current 0.2 VA of rating<br />
Additional fault current measurement<br />
up to 20 x line<br />
Over current detection<br />
Total harmonic distortion (THD)<br />
PLC applications for voltage dip<br />
detection available<br />
Power supply: 24V DC (± 20%)<br />
MODBUS interface<br />
Integrated in RTU560 engineering<br />
© ABB Group<br />
March 4, 2012 | Slide 16
<strong>Modules</strong><br />
RTU560/RTU211 DIN rail solution<br />
Technical data<br />
RTU560 for DIN rail<br />
Technical data<br />
RTU211 for DIN rail<br />
<strong>CMU</strong>s<br />
I/Os<br />
Communication<br />
modules<br />
Auxiliary<br />
Analog output 23AO60<br />
2 analog outputs for set points<br />
Resolution: 11 bit +sign<br />
Accuracy class: 0,25<br />
Ranges: ± 2,5 mA, ± 5mA, ± 10 m,<br />
± 20 mA, 420 mA, ± 1 VDC,<br />
± 10VDC<br />
Length: 105 mm<br />
Housing should be ordered<br />
separately<br />
© ABB Group<br />
March 4, 2012 | Slide 17
<strong>Modules</strong><br />
RTU560/RTU211 DIN rail solution<br />
Technical data<br />
RTU560 for DIN rail<br />
Technical data<br />
RTU211 for DIN rail<br />
<strong>CMU</strong>s<br />
I/Os<br />
Communication<br />
modules<br />
Auxiliary<br />
Analog line modems<br />
560FSM10/11<br />
1872 VDC<br />
Serial optical interfaces<br />
560FOC40<br />
18...30VDC<br />
560FOC80<br />
5 VDC<br />
23SC60<br />
R008 glass fiber<br />
R009 plastic fiber<br />
ABB 560FOC80<br />
© ABB Group<br />
March 4, 2012 | Slide 18
<strong>Modules</strong><br />
RTU560/RTU211 DIN rail solution<br />
Technical data<br />
RTU560 for DIN rail<br />
Technical data<br />
RTU211 for DIN rail<br />
<strong>CMU</strong>s<br />
I/Os<br />
Communication<br />
modules<br />
Auxiliary<br />
Modem 560FSM10 and 560FSM11<br />
560FSM10<br />
V.23 modem<br />
Functionality comparable to<br />
23WT23<br />
Power supply: 1872 VDC<br />
560FSM11 R0001<br />
9600 baud modem<br />
Functionality comparable to<br />
23WT24<br />
Power supply: 18..72 VDC<br />
© ABB Group<br />
March 4, 2012 | Slide 19
<strong>Modules</strong><br />
RTU560/RTU211 DIN rail solution<br />
Technical data<br />
RTU560 for DIN rail<br />
Technical data<br />
RTU211 for DIN rail<br />
<strong>CMU</strong>s<br />
I/Os<br />
Communication<br />
modules<br />
Auxiliary<br />
Serial optical interface 560FOC40 and<br />
560FOC80<br />
Opto coupler unit<br />
Power supply:<br />
560FOC40: 24 VDC (18..30VDC)<br />
560FOC80: 5 VDC<br />
Support of glass fiber (62,5/125µm)<br />
BFOC 2,5 connector<br />
RS485 electrical interface<br />
ABB 560FOC80<br />
Compatible to 23OK22/24<br />
© ABB Group<br />
March 4, 2012 | Slide 20
<strong>Modules</strong><br />
RTU560/RTU211 DIN rail solution<br />
Technical data<br />
RTU560 for DIN rail<br />
Technical data<br />
RTU211 for DIN rail<br />
<strong>CMU</strong>s<br />
I/Os<br />
Communication<br />
modules<br />
Auxiliary<br />
Star coupler 23SC60<br />
Used to connect decentralize I/O<br />
racks up to 2 km<br />
Versions for different medias<br />
R008x: multi mode glass fiber<br />
R009x: plastic fiber<br />
2..5 optical interfaces per housing<br />
available<br />
To be used to connect 23BE40,<br />
23BA40 and 23BE50 to DIN rail<br />
RTUs<br />
© ABB Group<br />
March 4, 2012 | Slide 21
<strong>Modules</strong><br />
RTU560/RTU211 DIN rail solution<br />
Technical data<br />
RTU560 for DIN rail<br />
Technical data<br />
RTU211 for DIN rail<br />
<strong>CMU</strong>s<br />
I/Os<br />
Communication<br />
modules<br />
Auxiliary<br />
Power supply units<br />
560PSU10<br />
560PSU40<br />
Input 110220<br />
VDC<br />
Output 24<br />
VDC/2,5A<br />
560PSU41 23PU63<br />
Input 2460 VDC Input 24110 VDC<br />
Output 24 VDC/2,5A Output 5V/1A, ±15V/0,<br />
18V/1A, 24V/0,5A<br />
23VG23/24<br />
© ABB Group<br />
March 4, 2012 | Slide 22
<strong>Modules</strong><br />
RTU560/RTU211 DIN rail solution<br />
Technical data<br />
RTU560 for DIN rail<br />
Technical data<br />
RTU211 for DIN rail<br />
<strong>CMU</strong>s<br />
I/Os<br />
Communication<br />
modules<br />
Auxiliary<br />
Power supply 23PSU40/41<br />
Input voltage<br />
560PSU40: 110220 VDC<br />
560PSU41: 2460 VDC<br />
Max. output power 60 W, 24 VDC:<br />
2,5 A<br />
1 LED for voltage supervision<br />
24VDC<br />
Overload and short-circuit<br />
protection<br />
Power good signal available (only<br />
560PSU40)<br />
Parallel peration possible (only<br />
560PSU40)<br />
© ABB Group<br />
March 4, 2012 | Slide 23
<strong>Modules</strong><br />
RTU560/RTU211 DIN rail solution<br />
Technical data<br />
RTU560 for DIN rail<br />
Technical data<br />
RTU211 for DIN rail<br />
<strong>CMU</strong>s<br />
I/Os<br />
Communication<br />
modules<br />
Auxiliary<br />
560PSU10<br />
560PSU10: Power supply unit for<br />
RTU560 DIN rail in cooperation with<br />
560<strong>CMU</strong>01<br />
The 560PSU10 supplies a total<br />
output of approx. 38 W. This is split<br />
to:<br />
<br />
<br />
<br />
<br />
+ 5 V DC and 1 A = 5 Watt<br />
+ 15 V DC and 0.5 A = 7.5 Watt<br />
15 V DC and 0.5 A = 7.5 Watt<br />
+ 18 V DC and 1A = 18 W<br />
© ABB Group<br />
March 4, 2012 | Slide 24
<strong>Modules</strong><br />
RTU560/RTU211 DIN rail solution<br />
Technical data<br />
RTU560 for DIN rail<br />
Technical data<br />
RTU211 for DIN rail<br />
<strong>CMU</strong>s<br />
Power supply 23PU63<br />
25W power supply<br />
Input voltage<br />
24 – 110 VDC (+/- 20%)<br />
Output voltage<br />
5V 1A (internal usage)<br />
+/-15V 0,2 A (RS232, AI/AO)<br />
18 V 1A (relays, AO)
<strong>Modules</strong><br />
RTU560/RTU211 DIN rail solution<br />
Technical data<br />
RTU560 for DIN rail<br />
Technical data<br />
RTU211 for DIN rail<br />
<strong>CMU</strong>s<br />
I/Os<br />
Communication<br />
modules<br />
Auxiliary<br />
Main adapter 23VG23<br />
Input Voltage 115 / 230 V AC<br />
without switch over<br />
24 VDC output voltage<br />
Power output 48 W<br />
Output current min. 0.2 A and max.<br />
2 A<br />
Integrated components:<br />
<br />
<br />
<br />
Battery charging device<br />
Switch over device<br />
Exhaustive discharge protection<br />
© ABB Group<br />
March 4, 2012 | Slide 26
<strong>Modules</strong><br />
RTU560/RTU211 DIN rail solution<br />
Technical data<br />
RTU560 for DIN rail<br />
Technical data<br />
RTU211 for DIN rail<br />
<strong>CMU</strong>s<br />
I/Os<br />
Communication<br />
modules<br />
Auxiliary<br />
Main adapter 23VG24<br />
Input Voltage 115 / 230 V AC<br />
Power output approx. 240 W<br />
24 VDC output voltage<br />
Output current max. 10 A<br />
© ABB Group<br />
March 4, 2012 | Slide 27