BD Totalys⢠MultiProcessor - Cellab
BD Totalys⢠MultiProcessor - Cellab
BD Totalys⢠MultiProcessor - Cellab
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>BD</strong> Totalys <strong>MultiProcessor</strong><br />
Advanced Automation in Cytology<br />
and Molecular Sample Preparation<br />
The new <strong>BD</strong> Totalys <strong>MultiProcessor</strong> † combines full<br />
automation and rigorous chain of custody for cervical<br />
testing and customizable molecular aliquots<br />
• Full chain of custody from collection vial to sample outputs<br />
• Automated sample transfer, centrifugation, aspiration, and decanting for cytology processes<br />
• LIS integration provides positive sample identification to downstream cervical and molecular diagnostic systems<br />
• Cytology samples processed include:<br />
- <strong>BD</strong> SurePath Liquid-based Pap Test<br />
• Broad menu of selectable molecular aliquots in a contaminant-free environment:<br />
- <strong>BD</strong> ProbeTec CT/GC Q x Amplified DNA Assays<br />
- <strong>BD</strong> hr-HPV-GT*<br />
- <strong>BD</strong> ProbeTec Trichomonas Assay*<br />
• Easy-to-use touch-screen interface<br />
*Sample types in development.<br />
†<br />
Instrument under development. Not yet approved by the FDA.<br />
Twister_SS.indd 1 18/09/2012 14:15:18
Efficiency, flexibility and confidence<br />
for your lab<br />
Efficient Throughput:<br />
• Processes up to 480 cytology samples with molecular aliquots in an eight-hour shift<br />
• Permits continual loading and unloading of samples in system to maximize efficiency<br />
Timely Results:<br />
• 96 cytology samples from vial to cell pellet in 105 minutes, with first 48 samples complete in 70 minutes<br />
• 96 cytology samples from vial to cell pellet with molecular aliquot in 120 minutes, with first 48 samples<br />
complete in 70 minutes<br />
Contamination Prevention:<br />
• Closed system<br />
• Automatically de-caps and re-caps samples to prevent splashing<br />
• Movement channels designed to control cross contamination<br />
SPECIMEN HANDLING<br />
Specimen Collection Type:<br />
Sample Volume:<br />
On-board Sample Capacity:<br />
Positive Sample Identification:<br />
DIMENSIONS<br />
Height:<br />
Width:<br />
Depth:<br />
Weight:<br />
<strong>BD</strong> SurePath Collection Vial<br />
- 8 mL aliquot drawn for cytology testing<br />
- Customizable molecular aliquots from .25 mL – 1.5 mL<br />
Up to 96 patient samples (six trays x 16 samples)<br />
2D barcodes on all patient vials and instrument<br />
consumables ensure chain of custody<br />
203.2 cm (80.0 in)<br />
162.6 cm (64.0 in)<br />
91.4 cm (36 in)<br />
636.4 kg (1400 lbs)<br />
ENVIRONMENTAL REQUIREMENTS<br />
Temperature: 18° C – 30° C (64.4° F – 86° F)<br />
Humidity:<br />
20% – 80% RH @ 18° C – 30° C non-condensing<br />
Locations:<br />
Level surface; no direct heat<br />
Altitude:<br />
up to 2,000 m (6,562 ft)<br />
Light Conditions:<br />
From dark to 15,000 lux; no direct light<br />
ELECTRICAL REQUIREMENTS<br />
Input Voltage: 100/120/220 – 240 VAC ± 10%<br />
Input Current:<br />
Input Line Frequency:<br />
10A/8A/6A<br />
47 – 63 Hz<br />
<strong>BD</strong>, <strong>BD</strong> Logo and all other trademarks are property of Becton, Dickinson and Company.<br />
©2012 <strong>BD</strong> All rights reserved. 980-08378-00 Rev 1 09/12<br />
<strong>BD</strong> Diagnostics<br />
Tullastrasse 8-12<br />
69126 Heidelberg<br />
Germany<br />
www.bd.com/ds<br />
Twister_SS.indd 2 18/09/2012 14:15:21