Wiring diagrams<br />

<strong>Charisma</strong> range - Roof circuits<br />

JP5<br />

S<br />

K<br />

S<br />

K<br />

Y/W<br />

Y/B<br />

RC1<br />

W/O<br />

K<br />

S<br />

K<br />

S W/O<br />

Y/W W/O<br />

Y/B<br />

B/U<br />

Fuse Unit part number NE189<br />

K<br />

K/B<br />

Single switch<br />

B/U<br />

W/O<br />

Option<br />

Speed switch<br />

Omnivent<br />

M<br />

See separate sheet for cable<br />

colour chart<br />

Dual coloured cables show in<br />

primary colour<br />

White cables shown in Black<br />

RC1 is roof connector<br />

Con sumer Circu its - Roof<br />

T3B / T4B range (where applicable)<br />

SARGENT ELECTRICAL SERVICES LTD Issue 01 05/02/08<br />

RL1<br />

RL2<br />

RL3<br />

RL4<br />

RL5<br />

RL6<br />

RL7<br />

RL8<br />

RL9<br />

SR1<br />

SR2<br />

R1<br />

TV1<br />

RA1<br />

Front locker lamp<br />

Front locker lamp<br />

Ceiling lamp<br />

Locker lamp<br />

Locker lamp<br />

Ceiling Lamp<br />

Locker lamp<br />

Locker lamp<br />

Awning lamp<br />

Bathroom lamp<br />

Bathroom lamp<br />

Radio/CD<br />

TV amplifier<br />

Powered radio antena<br />

10w<br />

10w<br />

20w<br />

10w<br />

10w<br />

20w<br />

10w<br />

10w<br />

21w<br />

10w<br />

10w<br />

W/O<br />

Single switch<br />

K/U<br />

Speaker<br />

RL6<br />

RL7<br />

RL8<br />

SR1<br />

SR2<br />

RL9<br />

RL1<br />

RL2<br />

RL3 RL4 RL5<br />

Speaker<br />

R1<br />

RA1<br />

Optional<br />

TV1<br />

12S Negative W/O<br />