15.01.2015 Views

Balanced Drive technical paper - Wavecor

Balanced Drive technical paper - Wavecor

Balanced Drive technical paper - Wavecor

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

TECHNICAL PAPER<br />

<strong>Wavecor</strong> <strong>Balanced</strong> <strong>Drive</strong> Technology<br />

Bxl [Tm]<br />

80%<br />

70%<br />

60%<br />

50%<br />

40%<br />

30%<br />

20%<br />

10%<br />

0%<br />

-10%<br />

-20%<br />

-30%<br />

-40%<br />

-50%<br />

-60%<br />

-70%<br />

-80%<br />

-90%<br />

-100%<br />

-110%<br />

-120%<br />

Symmetry check of Bxl curve, non-mirror less mirror curve<br />

relative to non-mirrored Bxl value<br />

DIRECTION OUT<br />

TOP PLATE<br />

DIRECTION IN<br />

20.50<br />

19.48<br />

18.45<br />

17.43<br />

16.40<br />

15.38<br />

14.35<br />

13.33<br />

12.30<br />

11.28<br />

10.25<br />

9.23<br />

8.20<br />

7.18<br />

6.15<br />

5.13<br />

4.10<br />

3.08<br />

2.05<br />

1.03<br />

Distance [mm]<br />

Fig. 7a. Bxl as a function of voice coil position for a traditional magnet structure as shown fig. 3a. The figure shows<br />

the relative symmetry as the difference when measuring Bxl out/in, held relative to the value outwards.<br />

0.00<br />

-1.03<br />

-2.05<br />

-3.08<br />

-4.10<br />

-5.13<br />

-6.15<br />

-7.18<br />

-8.20<br />

-9.23<br />

-10.25<br />

-11.28<br />

-12.30<br />

-13.33<br />

-14.35<br />

-15.38<br />

-16.40<br />

-17.43<br />

-18.45<br />

-19.48<br />

-20.50<br />

Bxl [Tm]<br />

80%<br />

70%<br />

60%<br />

50%<br />

40%<br />

30%<br />

20%<br />

10%<br />

0%<br />

-10%<br />

-20%<br />

-30%<br />

-40%<br />

-50%<br />

-60%<br />

-70%<br />

-80%<br />

-90%<br />

-100%<br />

-110%<br />

-120%<br />

Symmetry check of Bxl curve, non-mirror less mirror curve<br />

relative to non-mirrored Bxl value<br />

DIRECTION OUT<br />

TOP PLATE<br />

DIRECTION IN<br />

20.50<br />

19.48<br />

18.45<br />

17.43<br />

16.40<br />

15.38<br />

14.35<br />

13.33<br />

12.30<br />

11.28<br />

10.25<br />

9.23<br />

8.20<br />

7.18<br />

6.15<br />

5.13<br />

4.10<br />

3.08<br />

2.05<br />

1.03<br />

Distance [mm]<br />

Fig. 7b. Bxl as a function of voice coil position for the <strong>Wavecor</strong> WF182BD01 mid/woofer. The figure shows the<br />

relative symmetry as the difference when measuring Bxl out/in, held relative to the value outwards. Notice the<br />

very significant improvement compared to fig. 7a.<br />

0.00<br />

-1.03<br />

-2.05<br />

-3.08<br />

-4.10<br />

-5.13<br />

-6.15<br />

-7.18<br />

-8.20<br />

-9.23<br />

-10.25<br />

-11.28<br />

-12.30<br />

-13.33<br />

-14.35<br />

-15.38<br />

-16.40<br />

-17.43<br />

-18.45<br />

-19.48<br />

-20.50<br />

Copyright © 2009 by <strong>Wavecor</strong> Ltd., Guangzhou, China. All rights reserved. <strong>Wavecor</strong> ® is a registered trademark of <strong>Wavecor</strong> Ltd.<br />

For more information please visit www.<strong>Wavecor</strong>.com<br />

Page 8

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!