Cat. # <strong>124</strong>B2216/<strong>124</strong>C0910<br />

Generic: Two-component Novolac Epoxy <strong>Coating</strong>.<br />

General Description: 100% solids Novolac epoxy coating with<br />

excellent chemical resistance properties which may be applied on<br />

both vertical and horizontal surfaces.<br />

Typical Uses: Excellent secondary containment coating with good<br />

chemical resistance. Also recommended for use on concrete floors<br />

in a wide range of facilities where abrasion resistance is required.<br />

May be applied to vertical surfaces up to 12.0 mils dry in one<br />

application. May also be applied to steel surfaces.<br />

Special Qualifications: See <strong>Chemical</strong> Resistance Guide for Tank<br />

Lining and <strong>Secondary</strong> <strong>Containment</strong>.<br />

Advantages:<br />

• High chemical resistance<br />

• High impact and abrasion resistance<br />

• Low odor application<br />

• <strong>Resistant</strong> to 98% sulfuric acid and 37% hydrochloric acid for<br />

splash, spills and secondary containment<br />

• <strong>Resistant</strong> to dilute organic acids, alkalies and organic solvents in<br />

splash spillage conditions<br />

• Excellent secondary containment lining<br />

• Can be applied up to 1/2'' thick on horizontal surface<br />

• May be applied up to 12 mils on vertical surfaces<br />

• Can be used as a broadcast, slurry or troweled system<br />

Color: Gray<br />

Finish: High Gloss<br />

Weight/Gallon: 11.5 lbs./gal. (1.38 kg/L)<br />

VOC (EPA 24): 0.29 lbs./gal. (35 g/L)<br />

Solids By Volume: 100%<br />

Theoretical Coverage at 1.0 Mil Dry: 1604 sq. ft./gal. (39.3 m 2 /L)<br />

Recommended Film Thickness: 20.0-25.0 mils (500-<br />

650 microns) dry –20.0-25.0 mils (500-650 microns) wet<br />

Systems: Please consult the appropriate system guide, the particular<br />

job specification or your ICI Paints Representative for proper systems<br />

using this product. Systems must be selected considering the<br />

particular environment involved.<br />

Minimum Dry Time (ASTM D 1640): At 20.0 mils (500 microns) DFT<br />

Substrate<br />

Temperature 50°F (16°C) 70°F (21°C) 90°F (32°C)<br />

Min. Recoat 25 Hours 6-7 Hours 4-5 Hours<br />

Maximum<br />

Self Recoat 48 Hours 24 Hours 8-9 Hours<br />

Ventilation, film thickness, humidity, thinning, and other factors can<br />

influence the rate of dry.<br />

Warning: The above table provides general guidelines only. Always consult<br />

your ICI Paints Representative for appropriate recoat windows since the<br />

maximum aged recoat time of this product may be significantly shortened or<br />

lengthened by a variety of conditions, including, but not limited to humidity,<br />

surface temperature, and the use of additives or thinners. The use of<br />

accelerators or force curing may shorten the aged recoat of individual<br />

coatings. The above recoat windows may not apply if recoating with a product<br />

other than those listed above. If the maximum aged recoat window is<br />

exceeded, please consult your ICI Paints Representative for appropriate<br />

recommendations to enhance adhesion. Failure to observe these precautions<br />

may result in intercoat delamination.<br />

Shelf Life: Over 12 months at 77°F (25°C) – unopened<br />

Mix Ratio: 1 (base): 1 (converter) – see mixing instructions.<br />

Induction: None required<br />

Pot Life: 30-45 minutes @ 77°F (25°C) and 50% R.H.<br />

Limitations of Use: Color change may occur with chemical<br />

exposure. Do not apply or cure when air or surface temperature<br />

may go below 50°F (10°C) or chemical resistance may be<br />

compromised.<br />

Adhesion (ASTM D 4541) – Excellent<br />

Abrasion Resistance (ASTM D 4060) – Excellent<br />

Service Temperature Limits: 250°F (121°C) dry<br />

Hardness: (ASTM D 3363), 7 day cure @ 77°F (25°C) – 6H<br />

Read Label and Material Safety Data Sheet Prior to Use. See other cautions on last page. DSF1-0690


All surfaces must be sound, dry, clean, free of oil, grease, dirt, mildew, form release<br />

agents, curing compounds, loose and flaking paint and other foreign substances.<br />

New Surfaces: Concrete – All surfaces must be brush blasted or power scarified. Care<br />

must be taken to ensure that the substrate to be covered is sound, clean and free of all<br />

laitance or other contaminants. Allow new concrete to cure for 30 days minimum. Seal the<br />

properly prepared surface with PRE-PRIME 167 sealer. Steel – Blast to near-white<br />

metal surface cleanliness in accordance with SSPC-SP10 or ISO-Sa2 1/2.<br />

Tinting: Do not tint.<br />

Thinning: Do not thin.<br />

Mixing: <strong>DEVRAN</strong> ® <strong>124</strong> coating is a two-component product supplied in two gallon<br />

and ten gallon kits which contain the proper ratio of ingredients. The entire contents<br />

of each container must be mixed together.<br />

Mix part A and part B together thoroughly, being sure to scrape the sides and bottom<br />

of the container. Continue mixing for another couple of minutes to insure a<br />

homogeneous mixture that is properly mixed. Mix the materials with slow speed<br />

mixing equipment in order to minimize air being whipped into the coating. Avoid<br />

storing or placing containers in direct sunlight.<br />

Application: Optimum application properties and working life of the coating are<br />

obtained when the mixed components are at 77°F (25°C). At extreme temperatures,<br />

efforts should be made to maintain mixed material at 77°F (25°C).<br />

<strong>DEVRAN</strong> <strong>124</strong> can be applied to floors and decks with a spreader, squeegee or roller.<br />

Be sure to apply this product at the recommended thickness. If air entrapment is<br />

encountered, use a “porcupine” or another type of air release roller tool; where plural<br />

component airless spray equipment is used, a 45 to 1 pump equipped with a 1 to 1<br />

cylinder pump should be used. All plural component applications require a volumetric<br />

check of the mix ratio. Do not apply or cure when air or surface temperature may go<br />

below 50°F (10°C) or chemical resistance may be compromised.<br />

A minimum of 24 hours cure at temperatures above 77°F<br />

GENERAL SURFACE PREPARATION<br />

DIRECTIONS FOR USE<br />

PRECAUTIONS<br />

Back Page: <strong>124</strong>B2216/<strong>124</strong>C0910<br />

Blast profile on steel should be 1.5 – 2.5 mils (38-62 microns) in depth and be of a<br />

sharp, jagged, nature as opposed to a “peen” pattern (from shot blasting). Surfaces<br />

must be free of grit dust. The first coat of the system should be applied to cleaned<br />

surfaces as soon as possible to prevent re-rusting or contamination.<br />

Previously Painted Surfaces: Remove old paint and prepare as under New<br />

Surfaces.<br />

(25°C) is required before the <strong>DEVRAN</strong> <strong>124</strong> can withstand light traffic. Full chemical<br />

resistance is achieved only after 7 days cure at 77°F (25°C).<br />

Although <strong>DEVRAN</strong> <strong>124</strong> coating is solventless, good ventilation with dry air is required for<br />

the protection of the applicator, to prevent condensation and to obtain proper coating<br />

performance. Ventilation should be maintained throughout the cure period. Be sure the<br />

air in the lowest areas is constantly replaced with fresh, dry air.<br />

Longer curing times with ventilation are required if temperatures are lower than 77°F<br />

(25°C). Do not allow coating to remain in the application equipment longer than 30<br />

minutes. Flush out all application equipment whenever there is a delay in application.<br />

When applying specialized sealer coats for anti-slips and chemical resistant properties,<br />

be sure to follow recommended recoat intervals.<br />

Spreading Rate: Apply at 64-80 sq. ft. per gallon (1.57-1.96 m 2 /L) 20.0-25.0 mils (500-<br />

625 microns) dry, 20.0-25.0 mils (500-625 microns) wet. Make allowances for any losses<br />

due to overspray or surface irregularities.<br />

Topcoats: None Recommended<br />

Dry Time (ASTM D 1640): At 77°F (25°C) & 50% R.H., dries to touch in 8 hours, dries<br />

hard in 18-22 hours. Dry to light traffic in 24 hours and reaches full cure in 7 days.<br />

Clean-up: Clean immediately with T-10 thinner, except in the South Coast Air Quality<br />

Management District use acetone or other solvent in compliance with local VOC and air<br />

quality regulations.<br />

WARNING! CORROSIVE. CAUSES EYE AND SKIN BURNS. HARMFUL OR FATAL IF SWALLOWED. ASPIRATION HAZARD-CAN ENTER LUNGS AND CAUSE DAMAGE.<br />

HARMFUL IF INHALED. MAY CAUSE CENTRAL NERVOUS SYSTEM EFFECTS, INCLUDING DIZZINESS, HEADACHE OR NAUSEA. CAUSES RESPIRATORY TRACT<br />

IRRITATION. MAY CAUSE ALLERGIC SKIN REACTION. OVEREXPOSURE MAY CAUSE LIVER, KIDNEY DAMAGE. USE ONLY WITH ADEQUATE VENTILATION. KEEP<br />

OUT OF THE REACH OF CHILDREN. NOTICE: Products in this series contain solvents. Reports have associated repeated and prolonged occupational overexposure to<br />

solvents with permanent brain and nervous system damage. Intentional misuse by deliberately concentrating and inhaling the contents may be harmful or fatal. For emergency<br />

information call (800) 545-2643. Note: These warnings encompass the product series. Prior to use, read and follow product-specific MSDS and label information. If<br />

sanding is done, wear a dust mask to avoid breathing of sanding dust. Do not breathe vapors or spray mist. Ensure fresh air entry during application and drying. Avoid contact with<br />

eyes and skin. If you experience eye watering, headaches, or dizziness, leave the area. If properly used, a respirator may offer additional protection. Obtain professional advice<br />

before using. Close container after each use. FIRST AID: In case of skin contact, wash thoroughly with soap and water. If any product remains, gently rub petroleum jelly, vegetable<br />

or mineral/baby oil onto skin, then wash again with soap and water. Repeated applications may be needed. Remove contaminated clothing. For eye contact, flush immediately with<br />

large amounts of water, for at least 15 minutes. Obtain emergency medical treatment. If swallowed, obtain medical treatment immediately. If inhalation causes physical<br />

discomfort, remove to fresh air. If discomfort persists or any breathing difficulty occurs, get medical help. KEEP FROM FREEZING.<br />

DS360-1003<br />

SHIPPING<br />

Flash Point: 200°F (93°C)<br />

Shipping Weight: 2 - 2 gallon kits - 52 lbs. (23.6 kg)<br />

Packaging: 2 gallon kit (7.57L) 10 gallon kit (37.85L) 10 gallon kit - 121 lbs. (55 kg)<br />

1 gallon base 5 gallon base<br />

1 gallon converter 5 gallon converter<br />

<strong>124</strong> (5/07)<br />