According to code, an application for permit for any proposed work shall be<br />
deemed to have been abandoned ____ after the date of filing for permit, unless a<br />
permit was issued.<br />
a) 30 days<br />
b) 60 days<br />
c) 180 days<br />
d) 365 days<br />
Answer: C<br />
Solution: 105.3.2<br />
Question ID: 18862<br />
2.<br />
A building permit for a single-family residential dwelling must be issued within<br />
_____ working days of application, unless unusual circumstances require a longer<br />
time period.<br />
a) 30 days<br />
b) 45 days<br />
c) 60 days<br />
d) 90 days<br />
Answer: A<br />
Solution: 105.3.4<br />
Question ID: 18863<br />
3.<br />
Who may submit the plans to local enforcement agencies for 1 and 2 family<br />
dwellings<br />
a) A registered Architect<br />
b) A registered Engineer<br />
c) A licensed contractor in <strong>Florida</strong><br />
d) All of the above<br />
Answer: D<br />
Solution: 107.1, 107.3.4.3<br />
Question ID: 18864<br />
© <strong>Contractors</strong> <strong>Institute</strong> 1<br />
March 2012
4.<br />
Work requiring a permit shall not commence until the permit holder posts the<br />
permit card in a conspicuous place on the premises. The building permit or copy<br />
shall be kept on the site of the work until ___ .<br />
a) final inspection is passed<br />
b) the owner accepts the project<br />
c) completion of the project<br />
d) a Certificate of Occupancy is issued<br />
Answer: C<br />
Solution: 105.7<br />
Question ID: 18865<br />
5.<br />
Who shall select and pay all costs of employing an inspector for a threshold<br />
building (*R)<br />
a) The fee owner of the building<br />
b) The prime contractor of record<br />
c) The project Architect<br />
d) The project Engineer<br />
Answer: A<br />
Solution: 110.3.7, 110.3.7.3<br />
Question ID: 18866<br />
6.<br />
A job permitted on 12-5-<strong>2010</strong> by the building department commenced on 2-15-<br />
2011. All work stopped on 4-4-2011. Work must restart by _____, or the permit is<br />
invalid.<br />
a) 5 - 4 - 2011<br />
b) 6 - 4 - 2011<br />
c) 8 - 15 - 2011<br />
d) 10 - 4 - 2011<br />
Answer: D<br />
Solution: 105.4.1<br />
Question ID: 18867<br />
7.<br />
According to code, which of the following is not a required building inspection <br />
a) Foundation inspection<br />
b) Framing inspection<br />
c) Sheathing inspection<br />
d) Rough-In inspection<br />
© <strong>Contractors</strong> <strong>Institute</strong> 2<br />
March 2012
Answer: D<br />
Solution: 110.3, <strong>Building</strong><br />
Question ID: 18868<br />
8.<br />
A permit application was submitted by a contractor on March 6, 2008. The<br />
contractor arrived at the building department on August 16, 2008 and submitted a<br />
written request to the building official for 1 extension of time, prior to the<br />
application being deemed to have been abandoned. On August 21, 2008, the<br />
building official had determined that justifiable cause was demonstrated and<br />
granted the extension to the contractor. The contractor has until ____ to provide<br />
all necessary documentation to the building official.<br />
a) September 20, 2008<br />
b) October 20, 2008<br />
c) November 19, 2008<br />
d) February 21, 2009<br />
Answer: C<br />
Solution: 105.3.2<br />
Question ID: 18869<br />
9.<br />
An application for permit for proposed work shall be deemed to have been<br />
abandoned if no permit was issued and no extension requested within _______ of<br />
the application date.<br />
a) 30 days<br />
b) 60 days<br />
c) 90 days<br />
d) 180 days<br />
Answer: D<br />
Solution: 105.3.2<br />
Question ID: 18870<br />
10.<br />
A permanent sign identifying the termite treatment provider, need for reinspection<br />
and treatment contract renewal shall be provided and posted near the<br />
_________________ <br />
a) building permit<br />
b) front entry door<br />
c) adjacent street<br />
d) water heater or electric panel<br />
© <strong>Contractors</strong> <strong>Institute</strong> 3<br />
March 2012
Answer: D<br />
Solution: 105.11<br />
Question ID: 18871<br />
11.<br />
Any person who commences any work on a building, structure, electrical, gas,<br />
plumbing or mechanical system before obtaining the necessary permits shall be<br />
subject to penalty of _______ of the usual permit fee in addition to the required<br />
permit fees.<br />
a) 50 %<br />
b) 100 %<br />
c) 200 %<br />
d) 300 %<br />
Answer: B<br />
Solution: 109.4<br />
Question ID: 18872<br />
12.<br />
Which of the following work descriptions would not require a permit<br />
a) The direct wiring and installation of a 40 gallon electric water heater<br />
b) The replacement of 12 linear feet of fascia board having water damage<br />
c) The installation of aluminum windows on wood bucks in masonry<br />
openings<br />
d) The installation of a portable cooling unit having a factory cord and<br />
plug<br />
Answer: D<br />
Solution: 105.2, Exemptions: Mechanical 3.<br />
Question ID: 18873<br />
13.<br />
When the <strong>Building</strong> Official issues a special permit for a temporary structure, such<br />
permit shall be limited as to time of service, but shall not be permitted for more<br />
than _______.<br />
a) 30 days<br />
b) 90 days<br />
c) 180 days<br />
d) 1 year<br />
Answer: C<br />
Solution: 108.1<br />
Question ID: 18874<br />
© <strong>Contractors</strong> <strong>Institute</strong> 4<br />
March 2012
14.<br />
Which of the following would require registered engineer documentation to<br />
permit <br />
a) Medical Gas documents for a $4,000 system<br />
b) Plumbing documents for a new building requiring a plumbing system<br />
with 200 fixture units at a cost of $40,000<br />
c) A 15 ton air conditioning system, serving 75 persons, at a cost of<br />
$50,000<br />
d) A fire sprinkler system for a building which will contain 75 new<br />
sprinkler heads<br />
Answer: D<br />
Solution: 105.3.1.2 Read 1, 2, 3, 4<br />
Question ID: 18875<br />
15.<br />
Each enforcement agency shall require that, on every threshold building, all<br />
shoring procedures, plans and details be submitted to the enforcement agency for<br />
record keeping. Each shoring installation ___ to be in compliance with the<br />
documents by the contractor. (*R)<br />
a) should be verified<br />
b) shall be observed<br />
c) shall be overseen and found<br />
d) shall be supervised, inspected and certified<br />
Answer: D<br />
Solution: 110.3.7.4.3<br />
Question ID: 18876<br />
16.<br />
Work shall be considered to be in active progress when the permit has received an<br />
approved inspection within _______ .<br />
a) 60 days<br />
b) 90 days<br />
c) 180 days<br />
d) 365 days<br />
Answer: C<br />
Solution: 105.4.1.3<br />
Question ID: 18877<br />
© <strong>Contractors</strong> <strong>Institute</strong> 5<br />
March 2012
17.<br />
At which of the following stages would the accessibility requirements be<br />
inspected <br />
a) Framing inspection<br />
b) Sheathing inspection<br />
c) Final inspection<br />
d) Prior to issuing the Certificate of Occupancy<br />
Answer: A<br />
Solution: 110.3 <strong>Building</strong> 2.<br />
Question ID: 18878<br />
18.<br />
Fire retardant treated wood is a wood product which, when impregnated with<br />
chemicals by the pressure process during manufacture, shall have a flame spread<br />
index of _______ .<br />
a) 5 or more<br />
b) 10 or less<br />
c) 15 or more<br />
d) 25 or less<br />
Answer: D<br />
Solution: 2303.2<br />
Question ID: 18879<br />
19.<br />
The line established by law, beyond which the building shall not extend, is the<br />
______ .<br />
a) Property line<br />
b) Setbacks<br />
c) <strong>Building</strong> line<br />
d) High water line<br />
Answer: C<br />
Solution: 202 Definitions B<br />
Question ID: 18880<br />
20.<br />
In accordance with <strong>Florida</strong> Statute, any building which is greater than 3 stories or<br />
50 feet in height is defined as ___________.<br />
a) Low-rise construction<br />
b) Mid-rise construction<br />
c) High-rise construction<br />
d) a Threshhold building<br />
© <strong>Contractors</strong> <strong>Institute</strong> 6<br />
March 2012
Answer: D<br />
Solution: 202 Definitions T<br />
Question ID: 18881<br />
21.<br />
The weight of all materials of construction, including walls, floors, roofs, ceilings,<br />
stairways, and fixed service equipment is _______ .<br />
a) Dead load<br />
b) Total load<br />
c) Live load<br />
d) Imposed load<br />
Answer: A<br />
Solution: 202 Definitions D 1602.1<br />
Question ID: 18882<br />
22.<br />
The opening between the top of the firebox and the smoke chamber is called<br />
__________________.<br />
a) the chamber taper<br />
b) the hearth<br />
c) the fireplace throat<br />
d) the flue damper<br />
Answer: C<br />
Solution: 2102 Definitions, F 2102.1<br />
Question ID: 18883<br />
23.<br />
A Barber shop, Bank or Car wash is an example of _____ occupancy.<br />
a) Assembly, Group A<br />
b) Industrial, Group F<br />
c) Business, Group B<br />
d) Institutional, Group I<br />
Answer: C<br />
Solution: 304.1<br />
Question ID: 18884<br />
© <strong>Contractors</strong> <strong>Institute</strong> 7<br />
March 2012
24.<br />
Which of the following Institutional occupancies would be Group I-3.<br />
a) Detoxification facilities<br />
b) Nursing homes<br />
c) Mental hospitals<br />
d) Reformatories<br />
Answer: D<br />
Solution: 308.3, 308.4<br />
Question ID: 18885<br />
25.<br />
R-1, R-2, R-3 and R-4 are ______________ .<br />
a) Types of insulation<br />
b) Residential Occupancies<br />
c) Estimating Divisions<br />
d) <strong>Building</strong> construction types<br />
Answer: B<br />
Solution: 310.1<br />
Question ID: 18886<br />
26.<br />
_____ occupancy is the use of a building or structure, or any portion thereof, in<br />
which 3 or more clients receive care, maintenance and supervision, by other than<br />
their relative(s) or legal guardian(s), for less than 24 hours per day.<br />
a) Group I<br />
b) Group D<br />
c) Group E<br />
d) Group M<br />
Answer: B<br />
Solution: 313.1<br />
Question ID: 18887<br />
© <strong>Contractors</strong> <strong>Institute</strong> 8<br />
March 2012
27.<br />
Regarding entrapment protection in swimming pools, if the suction outlet system,<br />
such as an automatic cleaning system, is a vacuum cleaner system which has a<br />
single suction outlet or multiple suction outlets which can be isolated by valves,<br />
then each suction outlet shall protect against user entrapment in accordance with<br />
____________ .<br />
a) ANSI/APSP 7<br />
b) ASTM 10<br />
c) NSPI 5<br />
d) NSF 51<br />
Answer: A<br />
Solution: 424.2.6.6<br />
Question ID: 18888<br />
28.<br />
Motor fuel-dispensing facility canopies and their supports over pumps shall be of<br />
non combustible materials, or if constructed of wood, shall be Type _______<br />
sizes. (*R)<br />
a) II<br />
b) III<br />
c) IV<br />
d) V<br />
Answer: C<br />
Solution: 406.5.3 1.<br />
Question ID: 18889<br />
29.<br />
Which section of the code applies to buildings having occupied floors located<br />
more than 75 feet above the lowest level of fire department vehicle access <br />
a) Low-Rise <strong>Building</strong>s<br />
b) High-Rise <strong>Building</strong>s<br />
c) Type I Construction<br />
d) Chapter 23<br />
Answer: B<br />
Solution: 403.1<br />
Question ID: 18890<br />
© <strong>Contractors</strong> <strong>Institute</strong> 9<br />
March 2012
30.<br />
Which section of the code covers the design and construction of swimming pools<br />
and bathing places<br />
a) Section 423<br />
b) Section 424<br />
c) Section 425<br />
d) Section 433<br />
Answer: B<br />
Solution: 401.2.1 424.1<br />
Question ID: 18891<br />
31.<br />
What type of construction attains its fire resistance by the size of heavy timber<br />
used <br />
a) Type IA<br />
b) Type IB<br />
c) Type IIC<br />
d) Type IV<br />
Answer: D<br />
Solution: 602.4<br />
Question ID: 18892<br />
32.<br />
For Type III construction, which of the following is not according to code<br />
_________ .<br />
a) Exterior walls are of non-combustible material<br />
b) Interior building elements are of any material permitted by code<br />
c) Fire-retardant -treated wood framing is not permitted<br />
d) Type IIIB roof construction requires no fire resistance rating<br />
Answer: C<br />
Solution: 602.3 Table 601<br />
Question ID: 18893<br />
33.<br />
The floor deck material used in Type IV construction consists of 3" nominal<br />
thickness tongue and groove material, this material shall be covered with<br />
_______________ .<br />
a) 15 / 32" wood structural panels<br />
b) 1" nominal tongue-and-groove flooring laid diagonally<br />
c) 1" nominal tongue-and-groove flooring laid crosswise<br />
d) Any choice will comply with the code<br />
© <strong>Contractors</strong> <strong>Institute</strong> 10<br />
March 2012
Answer: D<br />
Solution: 602.4.4<br />
Question ID: 18894<br />
34.<br />
Framed timber trusses supporting floor loads in Type IV construction shall have<br />
members of not less than ______ nominal in any dimension.<br />
a) 6"<br />
b) 8"<br />
c) 10"<br />
d) 12"<br />
Answer: B<br />
Solution: 602.4.2<br />
Question ID: 18895<br />
35.<br />
Without exception, combustibles are permitted in concealed spaces in ____<br />
construction.<br />
a) Type I<br />
b) Type II<br />
c) Type IV<br />
d) Type VI<br />
Answer: C<br />
Solution: 717.5 602.4<br />
Question ID: 18896<br />
36.<br />
If a building has two uses or occupancies, such as Business, Group B and<br />
Residential, Group R-3, the minimum fire resistance for the fire wall that<br />
separates the two occupancies is _____________ hours. Assume Type III<br />
construction.<br />
a) 2<br />
b) 3<br />
c) 4<br />
d) 5<br />
Answer: B<br />
Solution: 706 Table 706.4 B = 3 hours R-3 = 2 hours, use the greater<br />
Question ID: 18897<br />
© <strong>Contractors</strong> <strong>Institute</strong> 11<br />
March 2012
37.<br />
The fire-resistance rating of building elements shall be determined in accordance<br />
with the test procedures set forth in ___________.<br />
a) ASTM C 926<br />
b) ASTM D 3769<br />
c) ASTM E 85<br />
d) ASTM E 119<br />
Answer: D<br />
Solution: 703.2<br />
Question ID: 18898<br />
38.<br />
Which of the following construction types would permit an exterior shaft<br />
enclosure of combustible materials<br />
a) Type IA<br />
b) Type IIB<br />
c) Type IIIA<br />
d) Type VA<br />
Answer: D<br />
Solution: 708.3 602.1 602.2 602.3 602.5 Table 601 Bearing Walls<br />
Question ID: 18899<br />
39.<br />
Townhouses shall be separated by a party wall. The party wall for the project does<br />
not extend above the roof. To comply with code, fire retardant roof sheathing may<br />
be used or 5/8" Type X gypsum is to be attached to the underside of the roof deck<br />
for not less than _______ .<br />
a) 4 foot width each side<br />
b) 6 foot width each side<br />
c) 8 foot width each side<br />
d) 12 foot width each side<br />
Answer: A<br />
Solution: 706, 706.4.1, 706.4.1.1 1, 2 and 3<br />
Question ID: 18901<br />
© <strong>Contractors</strong> <strong>Institute</strong> 12<br />
March 2012
40.<br />
If 1/2" gypsum wallboard on the fire exposed side of a wall has a time assigned to<br />
burn of 15 minutes, then 2 layers of 1/2" wallboard would have a time assigned of<br />
_______ .<br />
a) 30 minutes<br />
b) 40 minutes<br />
c) 60 minutes<br />
d) 90 minutes<br />
Answer: B<br />
Solution: 721.2.1.4.2, Table 721.2.1.4(2), Review Table<br />
Question ID: 18902<br />
41.<br />
A lightweight concrete slab will have a fire rating of _______ , if the slab is 3.6"<br />
thick.<br />
a) 1 hour minimum<br />
b) 1-1/2 hours<br />
c) 2 hours<br />
d) 3 hours<br />
Answer: C<br />
Solution: Table 721.2.2.1<br />
Question ID: 18903<br />
42.<br />
A 10" x 10" carbonate concrete column will have a fire resistance rating of<br />
______ .<br />
a) 1 hour<br />
b) 1-1/2 hours<br />
c) 2 hours<br />
d) 3 hours<br />
Answer: C<br />
Solution: Table 721.2.4<br />
Question ID: 18904<br />
© <strong>Contractors</strong> <strong>Institute</strong> 13<br />
March 2012
43.<br />
In a building of a single occupancy classification, when enclosed spaces are<br />
provided for individual tenants, such spaces shall be separated by not less than<br />
_______ fire resistance. No sprinkler system has been provided<br />
a) 30 minutes<br />
b) 1 hour<br />
c) 1.5 hours<br />
d) 2 hours<br />
Answer: B<br />
Solution: 709, 709.1, #6. 709.3 Except. 2<br />
Question ID: 18905<br />
44.<br />
Standpipe systems shall be provided when the highest floor is greater than<br />
_______ above the lowest level of fire department vehicle access. (*R)<br />
a) 100 feet<br />
b) 75 feet<br />
c) 50 feet<br />
d) 30 feet<br />
Answer: D<br />
Solution: 905 905.3.1<br />
Question ID: 18907<br />
45.<br />
The type of standpipe with a 1-1/2" hose used primarily by building occupants<br />
until the arrival of the fire department is classified as ____ . (*R)<br />
a) Class I<br />
b) Class II<br />
c) Class III<br />
d) Class IV<br />
Answer: B<br />
Solution: 202 Standpipe Systems 902.1 Definitions Standpipe, Classes<br />
Question ID: 18908<br />
46.<br />
Which of the following best describes an automatic wet standpipe (*R)<br />
a) A system with an operable valve, that can be opened at any time.<br />
b) A system with a water supply that is capable of supplying the system<br />
demand automatically<br />
c) A system accessible by the fire department, and activated when needed.<br />
d) A system connected to a small water supply, a filled standpipe.<br />
© <strong>Contractors</strong> <strong>Institute</strong> 14<br />
March 2012
Answer: B<br />
Solution: 902.1 Definitions Standpipe Types Automatic wet<br />
Question ID: 18909<br />
47.<br />
Emergency escape and rescue openings shall have the bottom of the clear opening<br />
not more than _____ above the floor.<br />
a) 32"<br />
b) 36"<br />
c) 44"<br />
d) 48"<br />
Answer: C<br />
Solution: 1029 1029.3<br />
Question ID: 18910<br />
48.<br />
Grade floor egress openings shall have a minimum net clear area of _____ square<br />
feet.<br />
a) 4.0<br />
b) 4.5<br />
c) 5.0<br />
d) 5.7<br />
Answer: C<br />
Solution: 1029.2, Exception:<br />
Question ID: 18911<br />
49.<br />
Externally illuminated exit signs shall have letters not less than _____ high.<br />
a) 3 inches<br />
b) 4 inches<br />
c) 6 inches<br />
d) 8 inches<br />
Answer: C<br />
Solution: 1006.3.5<br />
Question ID: 18912<br />
© <strong>Contractors</strong> <strong>Institute</strong> 15<br />
March 2012
50.<br />
Egress doors used as an exit door shall provide a clear opening width not less than<br />
____ .<br />
a) 28 inches<br />
b) 30 inches<br />
c) 32 inches<br />
d) 36 inches<br />
Answer: C<br />
Solution: 1008.1.1<br />
Question ID: 18913<br />
51.<br />
Egress ramps shall not have a slope greater than _______ in the direction of<br />
travel.<br />
a) 1 to 8<br />
b) 1 to 10<br />
c) 1 to 12<br />
d) 1 to 50<br />
Answer: C<br />
Solution: 1010.2<br />
Question ID: 18914<br />
52.<br />
When determining the occupant load for residential occupancies, the required area<br />
per occupant should be ___________ square feet.<br />
a) 120 net<br />
b) 150 gross<br />
c) 175 net<br />
d) 200 gross<br />
Answer: D<br />
Solution: Table 1004.1.1<br />
Question ID: 18915<br />
53.<br />
Which choice does not meet code for 1 and 2 family dwelling stairway<br />
construction <br />
a) 6 inch risers and 12 inch treads<br />
b) 6-1/2 inch risers and 11-1/2 inch treads<br />
c) 7 inch risers and 11 inch treads<br />
d) 8 inch risers and 10 inch treads<br />
© <strong>Contractors</strong> <strong>Institute</strong> 16<br />
March 2012
Answer: D<br />
Solution: 1009.4.2<br />
Question ID: 18916<br />
54.<br />
For other than 1 and 2 family dwellings, the maximum riser height shall be<br />
________ .<br />
a) 7-3/4 inches<br />
b) 7 inches<br />
c) 6-3/4 inches<br />
d) 6-1/2 inches<br />
Answer: B<br />
Solution: 1009.4.2<br />
Question ID: 18917<br />
55.<br />
Stairways, excluding spiral stairways, serving as an egress means shall have a<br />
minimum headroom clearance of ___ .<br />
a) 8'- 0"<br />
b) 7'- 6"<br />
c) 7'- 0"<br />
d) 6'- 8"<br />
Answer: D<br />
Solution: 1009.2<br />
Question ID: 18918<br />
56.<br />
Egress ramps shall have a maximum cross slope of ________ .<br />
a) 1:50<br />
b) 1:48<br />
c) 1:12<br />
d) 1:8<br />
Answer: B<br />
Solution: 1010.3<br />
Question ID: 18919<br />
© <strong>Contractors</strong> <strong>Institute</strong> 17<br />
March 2012
57.<br />
<strong>Building</strong>s four stories or more in height shall be provided with a stairway to the<br />
roof, when the slope of the roof is ____ or less.<br />
a) 2:12<br />
b) 3:12<br />
c) 4:12<br />
d) 6:12<br />
Answer: C<br />
Solution: 1009.13<br />
Question ID: 18920<br />
58.<br />
The minimum net clear opening height shall be _____ for emergency escape<br />
openings.<br />
a) 20"<br />
b) 22"<br />
c) 24"<br />
d) 32"<br />
Answer: C<br />
Solution: 1029.2.1<br />
Question ID: 18921<br />
59.<br />
The minimum net clear opening width shall be _____ for emergency escape<br />
openings.<br />
a) 20"<br />
b) 22"<br />
c) 24"<br />
d) 32"<br />
Answer: A<br />
Solution: 1029.2.1<br />
Question ID: 18922<br />
60.<br />
The variation allowed in any 2 treads or risers in a stairway shall not exceed<br />
_____ , greatest to least.<br />
a) 3/32"<br />
b) 3/16"<br />
c) 3/8"<br />
d) 3/4"<br />
© <strong>Contractors</strong> <strong>Institute</strong> 18<br />
March 2012
Answer: C<br />
Solution: 1009.4.4 (0.375 x 8 = 3 "3/8")<br />
Question ID: 18924<br />
61.<br />
When providing under-floor ventilation for the interior environment, the<br />
foundation wall openings shall be covered for their height and width. Which of<br />
the following selections may be used<br />
a) 0.040" perforated sheet metal<br />
b) 0.035" wire hardware cloth<br />
c) 0.030" expanded sheet metal<br />
d) fiberglass screen, 20/20 mesh<br />
Answer: B<br />
Solution: 1203.3.1 5. see 1. 2.<br />
Question ID: 18941<br />
62.<br />
Every space intended for human occupancy shall be provided with natural light by<br />
means of exterior glazed openings. The minimum net glazed area shall not be less<br />
than _____ percent of the floor area of the room served. Assume no artificial<br />
lighting has been provided.<br />
a) 4 percent<br />
b) 8 percent<br />
c) 12 percent<br />
d) 25 percent<br />
Answer: B<br />
Solution: 1205.1 1205.2<br />
Question ID: 18942<br />
63.<br />
Habitable spaces in buildings, other than storage and laundry rooms shall have a<br />
ceiling height of not less than _________ .<br />
a) 7'- 0"<br />
b) 7'- 6"<br />
c) 7'- 8"<br />
d) 8'- 0"<br />
Answer: B<br />
Solution: 1208.2<br />
Question ID: 18943<br />
© <strong>Contractors</strong> <strong>Institute</strong> 19<br />
March 2012
64.<br />
Bathrooms containing bathtubs or showers shall be ventilated in accordance with<br />
___________.<br />
a) the Mechanical <strong>Code</strong>, mechanical means<br />
b) the minimum 3 square foot rule<br />
c) the operable opening code<br />
d) the energy code<br />
Answer: A<br />
Solution: 1203.4.2.1<br />
Question ID: 18944<br />
65.<br />
The height of any section of thin exterior structural glass veneer shall not exceed<br />
_____ .<br />
a) 24"<br />
b) 30"<br />
c) 36"<br />
d) 48"<br />
Answer: D<br />
Solution: 1405.12 1405.12.1<br />
Question ID: 18960<br />
66.<br />
To provide for inspection for termite infestation, clearance between exterior wall<br />
coverings and final earth grade on the exterior of a building shall not be less than<br />
____________ .<br />
a) 2 inches<br />
b) 3 inches<br />
c) 6 inches<br />
d) 8 inches<br />
Answer: C<br />
Solution: 1403.7<br />
Question ID: 18961<br />
67.<br />
Metal veneer used as an exterior wall covering shall not be less than ______<br />
nominal thickness sheet steel mounted on wood furring.<br />
a) 0.0120"<br />
b) 0.120"<br />
c) 0.0149"<br />
d) 0.149"<br />
© <strong>Contractors</strong> <strong>Institute</strong> 20<br />
March 2012
Answer: C<br />
Solution: 1405.11<br />
Question ID: 18962<br />
68.<br />
The minimum 6 inch clearance for inspection for termite infestation shall be<br />
provided in order to comply with the code, except _______ .<br />
a) for a decorative cementitious finish less than 5/8" directly adhered to<br />
masonry<br />
b) for the width of an access ramp which rises to the finish floor elevation<br />
c) for a 4" inspection space above a patio slab, garage slab or entry area<br />
slab<br />
d) all of the above choices are exceptions from this code requirement<br />
Answer: D<br />
Solution: 1403.7 Exceptions 1. 2. 3.<br />
Question ID: 18963<br />
69.<br />
An example of a Class A roof covering, without testing, is ________ .<br />
a) Standing seam sheet metal<br />
b) Aluminum pans<br />
c) Slate<br />
d) Shingles, 3-tab or dimensional<br />
Answer: C<br />
Solution: 1505.2 Exception 2<br />
Question ID: 18964<br />
70.<br />
All condensate lines and roof downspouts shall discharge at least ___ away from<br />
the structure sidewall.<br />
a) 6 inches<br />
b) 8 inches<br />
c) 12 inches<br />
d) 24 inches<br />
Answer: C<br />
Solution: 1503.7<br />
Question ID: 18965<br />
© <strong>Contractors</strong> <strong>Institute</strong> 21<br />
March 2012
71.<br />
According to code, gutters with downspouts are required on buildings with eaves<br />
of less than _____ horizontal projection except for gable end rakes or a roof above<br />
another roof.<br />
a) 4 inches<br />
b) 6 inches<br />
c) 12 inches<br />
d) 18 inches<br />
Answer: B<br />
Solution: 1503.7<br />
Question ID: 18966<br />
72.<br />
Which of the weather protection locations shall require flashing<br />
a) hip and ridge junctions<br />
b) above roof openings<br />
c) wall and roof intersections<br />
d) sill plate at stemwall<br />
Answer: C<br />
Solution: 1503.2.1<br />
Question ID: 18967<br />
73.<br />
When other means of drainage of overflow water is not provided, overflow<br />
scuppers shall be placed in walls or parapets not less than ___________ above the<br />
finished roof covering<br />
a) 2 inches nor more than 4 inches<br />
b) 4 inches<br />
c) 6 inches nor more than 8 inches<br />
d) 8 inches<br />
Answer: A<br />
Solution: 1503.4.2.1<br />
Question ID: 18968<br />
74.<br />
Flashing for roof assemblies shall be installed at _______ .<br />
a) Gutters<br />
b) Above roof openings<br />
c) Ridge junctions<br />
d) Hip junctions<br />
© <strong>Contractors</strong> <strong>Institute</strong> 22<br />
March 2012
Answer: A<br />
Solution: 1503.2.1<br />
Question ID: 18969<br />
75.<br />
Where roof flashing is of metal, the thickness shall be not less than ______ , if<br />
galvanized sheet was selected.<br />
a) 26 gage<br />
b) 24 gage<br />
c) 22 gage<br />
d) 20 gage<br />
Answer: A<br />
Solution: 1503.2.1 Table 1503.2 Galv. Gage<br />
Question ID: 18970<br />
76.<br />
Which of the following standards shall asphalt shingle fasteners comply with <br />
a) ASTM C 926<br />
b) ASTM E 118<br />
c) ASTM A 153<br />
d) ASTM F 1667<br />
Answer: D<br />
Solution: 1507.2.6<br />
Question ID: 18971<br />
77.<br />
Fasteners for asphalt shingles shall be roofing nails of a length to penetrate<br />
through the roofing materials and a minimum of _______ into the roof sheathing.<br />
a) 1/2 inch<br />
b) 5/8 inch<br />
c) 3/4 inch<br />
d) 7/8 inch<br />
Answer: C<br />
Solution: 1507.2.6<br />
Question ID: 18972<br />
© <strong>Contractors</strong> <strong>Institute</strong> 23<br />
March 2012
78.<br />
Asphalt shingles shall be secured to the roof with not less than _____ fasteners<br />
per strip.<br />
a) 2<br />
b) 3<br />
c) 4<br />
d) 6<br />
Answer: C<br />
Solution: 1507.2.7<br />
Question ID: 18973<br />
79.<br />
For roof slopes of 4:12 or greater, underlayment shall be a minimum of 1 layer of<br />
felt, lapped ___ , and fastened sufficiently to hold in place.<br />
a) 19 inches<br />
b) 12 inches<br />
c) 3 inches<br />
d) 2 inches<br />
Answer: D<br />
Solution: 1507.2.8<br />
Question ID: 18974<br />
80.<br />
What is the fastening pattern for base and counter flashing on an asphalt shingle<br />
roof <br />
a) 4 inches on center<br />
b) 6 inches on center<br />
c) 8 inches on center<br />
d) 12 inches on center<br />
Answer: B<br />
Solution: 1507.2.9.1 2.<br />
Question ID: 18975<br />
81.<br />
What is the minimum width for open valley metal on an asphalt shingle roof <br />
a) 12 inches<br />
b) 16 inches<br />
c) 18 inches<br />
d) 36 inches<br />
© <strong>Contractors</strong> <strong>Institute</strong> 24<br />
March 2012
Answer: B<br />
Solution: 1507.2.9.2 1.<br />
Question ID: 18976<br />
82.<br />
The minimum overlap of dripedge shall be ______ for eaves and gables of shingle<br />
roofs.<br />
a) 1 inch<br />
b) 3 inches<br />
c) 4 inches<br />
d) 6 inches<br />
Answer: B<br />
Solution: 1507.2.9.3<br />
Question ID: 18977<br />
83.<br />
Dripedge shall be mechanically fastened a maximum of ____ on center. Assume<br />
100 mph basic wind speed. Assume a 16 foot eave height.<br />
a) 4 inches<br />
b) 6 inches<br />
c) 8 inches<br />
d) 12 inches<br />
Answer: D<br />
Solution: 1507.2.9.3<br />
Question ID: 18978<br />
84.<br />
The perimeter fastening area for concrete roof tile includes attaching wire which<br />
shall be not smaller than ___________ .<br />
a) 0.025 inch<br />
b) 0.040 inch<br />
c) 0.075 inch<br />
d) 0.083 inch<br />
Answer: D<br />
Solution: 1507.3.6<br />
Question ID: 18980<br />
© <strong>Contractors</strong> <strong>Institute</strong> 25<br />
March 2012
85.<br />
The minimum headlap for slate shingles on a roof with a 5:12 slope shall be<br />
______ .<br />
a) 2 inches<br />
b) 3 inches<br />
c) 4 inches<br />
d) 6 inches<br />
Answer: C<br />
Solution: 1507.7.6 See Table 1507.7.6 4:12< x < 8:12 x = 5:12<br />
Question ID: 18981<br />
86.<br />
What is the exposure for 18", No. 1, naturally durable wood shingles on a 5:12<br />
roof <br />
a) 3-3/4 inches<br />
b) 5-1/2 inches<br />
c) 7-1/2 inches<br />
d) 10 inches<br />
Answer: B<br />
Solution: Table 1507.8.7, shingles, not shakes<br />
Question ID: 18982<br />
87.<br />
Wood shingles and shakes shall be laid with a side lap not less than ____.<br />
a) 1-1/2 inches<br />
b) 2 inches<br />
c) 3 inches<br />
d) 4 inches<br />
Answer: A<br />
Solution: 1507.8.7 1507.9.8<br />
Question ID: 18983<br />
88.<br />
What is the exposure for 18", No. 1 naturally durable wood shakes on a 5:12 roof<br />
<br />
a) 5-1/2 inches<br />
b) 6-1/2 inches<br />
c) 7-1/2 inches<br />
d) 10 inches<br />
© <strong>Contractors</strong> <strong>Institute</strong> 26<br />
March 2012
Answer: C<br />
Solution: Table 1507.9.8, shakes, not shingles<br />
Question ID: 18984<br />
89.<br />
Roof mounted mechanical units shall be mounted on curbs raised a minimum of<br />
_____ .<br />
a) 4 inches<br />
b) 8 inches<br />
c) 18 inches<br />
d) 24 inches<br />
Answer: B<br />
Solution: 1509.7<br />
Question ID: 18985<br />
90.<br />
What is the minimum uniformly distributed live load for stairs in a 2 family<br />
dwelling <br />
a) 30 psf<br />
b) 40 psf<br />
c) 75 psf<br />
d) 100 psf<br />
Answer: B<br />
Solution: Table 1607.1 #35 Stairs and Exits 1 & 2 family<br />
Question ID: 18986<br />
91.<br />
What is the live load deflection limit for a floor joist having a 15' clear span<br />
a) 1/2"<br />
b) 5/8"<br />
c) 3/4"<br />
d) 7/8"<br />
Answer: A<br />
Solution: Table 1604.3 Floor member Live = L L / 360 15 x 12 = 180 / 360 = .5"<br />
Question ID: 18987<br />
© <strong>Contractors</strong> <strong>Institute</strong> 27<br />
March 2012
92.<br />
Where the wood shim or buck thickness is less than 1-1/2", window and door<br />
assemblies shall be anchored through the jamb. Anchors shall be securely<br />
fastened ____________ .<br />
a) to the wood shim or wood buck<br />
b) directly into the masonry or concrete substrate<br />
c) to transfer the load to the wood buck material<br />
d) at a maximum of 8 inch on center spacing<br />
Answer: B<br />
Solution: 1715.5.4.2<br />
Question ID: 18988<br />
93.<br />
Where the wood buck thickness is 1-1/4" or greater, the buck shall be securely<br />
fastened to transfer load to the concrete or masonry. Window and door assemblies<br />
shall be anchored through the jamb or flange and fastened __________________ .<br />
a) to the secured wood buck<br />
b) directly into the masonry or concrete substrate<br />
c) to transfer the load directly to the structure<br />
d) at a maximum of 8 inch on center spacing<br />
Answer: A<br />
Solution: 1714.5.4.2<br />
Question ID: 18989<br />
94.<br />
Which of the following complies with the code regarding structural steel H-piles <br />
a) Flange projections can exceed 14 times the minimum thickness of the<br />
metal<br />
b) Flange widths shall be not less than 50% of the depth<br />
c) The nominal depth in the direction of the flange shall be not less than 8<br />
inches<br />
d) Flanges and web shall have a minimum thickness of 3/8"<br />
Answer: D<br />
Solution: 1810.3.5.3.1 1. 2. 3. See 3.<br />
Question ID: 18994<br />
© <strong>Contractors</strong> <strong>Institute</strong> 28<br />
March 2012
95.<br />
Unit masonry walls shall be parged on the exterior surface below ground level<br />
with not less than ______ of Portland cement mortar. Assume surface preparation<br />
for dampproofing of foundation wall.<br />
a) 3/4 inch<br />
b) 1/2 inch<br />
c) 3/8 inch<br />
d) 1/4 inch<br />
Answer: C<br />
Solution: 1805 1805.2 1805.2.2 1805.2.2.1<br />
Question ID: 18996<br />
96.<br />
If soil treatment is used for subterranean termite prevention, chemical soil<br />
treatments shall also be applied under all exterior concrete within _____ of the<br />
structure sidewalls.<br />
a) 4 inches<br />
b) 6 inches<br />
c) 12 inches<br />
d) 18 inches<br />
Answer: C<br />
Solution: 1816.1.6<br />
Question ID: 18998<br />
97.<br />
The minimum thickness for concrete floor slabs supported directly on the ground<br />
shall not be less than _______ unless designed by an architect or engineer.<br />
a) 3 inches<br />
b) 3-1/2 inches<br />
c) 4 inches<br />
d) 5 inches<br />
Answer: B<br />
Solution: 1910.1<br />
Question ID: 18999<br />
© <strong>Contractors</strong> <strong>Institute</strong> 29<br />
March 2012
98.<br />
The minimum concrete cover for concrete cast against and permanently exposed<br />
to earth shall be in accordance with __________ .<br />
a) ACI 101<br />
b) ACI 208<br />
c) ACI 318<br />
d) ASCE 7<br />
Answer: C<br />
Solution: 1907 1907.7 1907.7.1<br />
Question ID: 19000<br />
99.<br />
Mixing of concrete shall be performed in accordance with __________ .<br />
a) ASTM C 550<br />
b) ACI 318<br />
c) ANSI E 85<br />
d) Ready Mixed Association<br />
Answer: B<br />
Solution: 1905.8<br />
Question ID: 19001<br />
100.<br />
What is the minimum thickness for a polyethylene vapor retarder beneath a<br />
concrete floor slab <br />
a) 2 mil<br />
b) 4 mil<br />
c) 6 mil<br />
d) 8 mil<br />
Answer: C<br />
Solution: 1910.1<br />
Question ID: 19003<br />
101.<br />
Conduits and pipes are permitted to be embedded in concrete if ___.<br />
a) placed within the top 1/3 of the slab<br />
b) approved by the registered design professional<br />
c) walls are thicker than 12 inches<br />
d) in accordance with ACI 813<br />
Answer: B<br />
Solution: 1906.3<br />
Question ID: 19004<br />
© <strong>Contractors</strong> <strong>Institute</strong> 30<br />
March 2012
102.<br />
Conducting strength tests of concrete shall be as specified in ACI 318, except<br />
when the total volume of concrete is less than ______ cubic yards.<br />
a) 50<br />
b) 30<br />
c) 20<br />
d) 10<br />
Answer: A<br />
Solution: 1905.6.2 Exception:<br />
Question ID: 19005<br />
103.<br />
What is the minimum thickness of a structural plain concrete foundation wall <br />
a) 6 inches<br />
b) 7-1/2 inches<br />
c) 8 inches<br />
d) 12 inches<br />
Answer: B<br />
Solution: 1909.6.1<br />
Question ID: 19006<br />
104.<br />
What is the weathering probability for concrete which is placed in Jacksonville,<br />
<strong>Florida</strong> <br />
a) Severe<br />
b) Moderate<br />
c) Negligible<br />
d) No probability<br />
Answer: C<br />
Solution: Figure 1904.3<br />
Question ID: 19007<br />
© <strong>Contractors</strong> <strong>Institute</strong> 31<br />
March 2012
105.<br />
The minimum thickness of reinforced gypsum concrete shall be ___. Assume no<br />
special conditions have been satisfied.<br />
a) 2"<br />
b) 3"<br />
c) 4"<br />
d) 6"<br />
Answer: A<br />
Solution: 1914.2<br />
Question ID: 19008<br />
106.<br />
Wall thickness of extruded aluminum members shall be not less than _____ for<br />
screen enclosures.<br />
a) .024 inch<br />
b) .040 inch<br />
c) .044 inch<br />
d) .052 inch<br />
Answer: B<br />
Solution: 2002.3.1<br />
Question ID: 19009<br />
107.<br />
According to the <strong>Code</strong>, and as a construction safeguard, what is the maximum<br />
slope for permanent fill on a jobsite Assume a soil investigation report has not<br />
been submitted.<br />
a) 1 unit vertical in 2 units horizontal<br />
b) 1 unit vertical in 1 unit horizontal<br />
c) 2 units vertical in 1 unit horizontal<br />
d) 1 unit vertical in 3 units horizontal<br />
Answer: A<br />
Solution: 3304.1.1 Slope limits<br />
Question ID: 19010<br />
108.<br />
The minimum thickness for formed sheet aluminum structural wall panels shall be<br />
____ .<br />
a) .020 inch<br />
b) .022 inch<br />
c) .024 inch<br />
d) .040 inch<br />
© <strong>Contractors</strong> <strong>Institute</strong> 32<br />
March 2012
Answer: C<br />
Solution: 2002.5<br />
Question ID: 19011<br />
109.<br />
Any portion of a masonry fireplace or chimney located in the interior of a<br />
building or within the exterior wall of a building shall have a clearance to<br />
combustibles of not less than _____.<br />
a) 1"<br />
b) 2"<br />
c) 3"<br />
d) 4"<br />
Answer: B<br />
Solution: 2111.11 2113.19<br />
Question ID: 19012<br />
110.<br />
Where a lining of firebrick at least 2" in thickness is provided for masonry<br />
fireplaces, the total thickness of the back and sidewalls, including the lining, shall<br />
be not less than __________ .<br />
a) 4"<br />
b) 6"<br />
c) 8"<br />
d) 10"<br />
Answer: C<br />
Solution: 2111.5<br />
Question ID: 19013<br />
111.<br />
Regarding masonry wall construction, walls _____ and less in height above grade<br />
do not require bracing.<br />
a) 6'<br />
b) 8'<br />
c) 10'<br />
d) 12'<br />
Answer: B<br />
Solution: 2104.1.7 Exception 2.<br />
Question ID: 19014<br />
© <strong>Contractors</strong> <strong>Institute</strong> 33<br />
March 2012
112.<br />
Where no firebrick lining is provided, the minimum thickness of the back and<br />
sidewalls shall be not less than _______ of solid masonry for fireplaces.<br />
a) 8"<br />
b) 10"<br />
c) 12"<br />
d) 16"<br />
Answer: B<br />
Solution: 2111.5<br />
Question ID: 19023<br />
113.<br />
The fireplace throat shall be located a minimum of _____ inches above the top of<br />
the fireplace opening.<br />
a) 6"<br />
b) 8"<br />
c) 12"<br />
d) 16"<br />
Answer: B<br />
Solution: 2111.7<br />
Question ID: 19024<br />
114.<br />
For conventional light wood frame construction, what is the maximum floor-tofloor<br />
height limit, to comply with the <strong>Building</strong> <strong>Code</strong><br />
a) 10 feet<br />
b) 11 feet, 7 inches<br />
c) 12 feet<br />
d) 20 feet<br />
Answer: B<br />
Solution: 2308 2308.2 Note 2.<br />
Question ID: 19025<br />
© <strong>Contractors</strong> <strong>Institute</strong> 34<br />
March 2012
115.<br />
Steel fireplace units incorporating a firebox liner of not less than 1/4 inch thick<br />
steel and an air-circulating chamber may be installed with masonry to provide a<br />
total thickness at the back and sides of not less than ____, of which not less than<br />
_____ shall be solid masonry.<br />
a) 4", 4"<br />
b) 6", 4"<br />
c) 6", 6"<br />
d) 8", 4"<br />
Answer: D<br />
Solution: 2111.5.1<br />
Question ID: 19026<br />
116.<br />
The firebox of a masonry fireplace shall have a minimum depth of 20". The throat<br />
shall be at least 8" above the fireplace opening. The throat opening shall be at<br />
least ____ deep.<br />
a) 2 inches<br />
b) 3 inches<br />
c) 4 inches<br />
d) 6 inches<br />
Answer: C<br />
Solution: 2111.6<br />
Question ID: 19027<br />
117.<br />
Regarding termite inspection, masonry veneer supported by a shelf, angle or lintel<br />
secured to the foundation sidewall shall provide at least a _____ inch clear<br />
inspection space of the foundation sidewall exterior existing between the veneer<br />
and the grade, deck or walk.<br />
a) 4<br />
b) 6<br />
c) 8<br />
d) 12<br />
Answer: B<br />
Solution: 2114.2 Exception:<br />
Question ID: 19028<br />
© <strong>Contractors</strong> <strong>Institute</strong> 35<br />
March 2012
118.<br />
Gable end walls of cold formed steel framing shall be structurally continuous<br />
between __________.<br />
a) points of lateral support<br />
b) opposing walls<br />
c) shearwalls<br />
d) hinge points<br />
Answer: A<br />
Solution: 2211.1<br />
Question ID: 19029<br />
119.<br />
What is the maximum post spacing permitted for chain link fence, when installed<br />
in the High Velocity Hurricane Zone <br />
a) 8 feet on center<br />
b) 10 feet on center<br />
c) 12 feet on center<br />
d) not permitted by <strong>Code</strong><br />
Answer: B<br />
Solution: Section 2224 Table 2224 Footnote: 9.<br />
Question ID: 19030<br />
120.<br />
For tubular columns in a High Velocity Hurricane Zone, concrete fill in tubular<br />
members shall not be assumed to carry any of the load except in compression<br />
members having a least dimension of ___ or greater and having a 1 inch<br />
inspection hole in the plate at each end.<br />
a) 6 inches<br />
b) 7 inches<br />
c) 8 inches<br />
d) 10 inches<br />
Answer: C<br />
Solution: 2219.3<br />
Question ID: 19031<br />
© <strong>Contractors</strong> <strong>Institute</strong> 36<br />
March 2012
121.<br />
The minimum clearance between wood siding and earth on the exterior of a<br />
building shall be not less than ______ , except where siding is of approved<br />
preservative-treated or naturally durable wood.<br />
a) 6"<br />
b) 8"<br />
c) 4"<br />
d) 2"<br />
Answer: A<br />
Solution: 2304.11.2.6<br />
Question ID: 19032<br />
122.<br />
Which of the following standards would preservative treated wood and the<br />
preservatives conform to <br />
a) ASTM Standards<br />
b) AITC Standards<br />
c) AWPA Standards<br />
d) ANSI Standards<br />
Answer: C<br />
Solution: 2303.1.8<br />
Question ID: 19033<br />
123.<br />
Which of the following is required by code when fastening a rafter to the plate.<br />
Assume toenailing.<br />
a) 3 - 16d common<br />
b) 2 - 8d common<br />
c) 3 - 6d common<br />
d) 3 - 8d common<br />
Answer: D<br />
Solution: Table 2304.9.1 #19.<br />
Question ID: 19034<br />
© <strong>Contractors</strong> <strong>Institute</strong> 37<br />
March 2012
124.<br />
Wood posts placed in a basement which will support permanent structures shall<br />
be supported by concrete piers that project at least _________ inch/es above the<br />
floor slab.<br />
a) 1<br />
b) 2<br />
c) 3<br />
d) 4<br />
Answer: A<br />
Solution: 2304.11.2.7 Exception: 1.<br />
Question ID: 19035<br />
125.<br />
Floor underlayment shall not be less than ______.<br />
a) 3/4" plywood<br />
b) 1/2" plywood<br />
c) 1/4" particleboard<br />
d) 1/8" MDO board<br />
Answer: C<br />
Solution: 2303.1.7.1<br />
Question ID: 19036<br />
126.<br />
Sills on continuous foundations shall be not less than 2" thick and shall be<br />
anchored by 1/2" bolts spaced not more than _____ apart and embedded at least<br />
7" into the concrete.<br />
a) 2'<br />
b) 4'<br />
c) 5'<br />
d) 6'<br />
Answer: D<br />
Solution: 2304.3.1 2308.6<br />
Question ID: 19037<br />
© <strong>Contractors</strong> <strong>Institute</strong> 38<br />
March 2012
127.<br />
Notches on the ends of joists shall not exceed 1/4 the depth. Holes bored for pipes<br />
or cables shall not be within 2 inches of the top or bottom of the joist and the<br />
diameter of any such hole shall not exceed _______ the depth of the joists.<br />
a) 1/4<br />
b) 1/3<br />
c) 1/6<br />
d) 1/2<br />
Answer: B<br />
Solution: 2308.8.2 2308.10.4.2<br />
Question ID: 19038<br />
128.<br />
____ common nails are used to nail double top plates in the lap splice.<br />
a) 12 - 8d<br />
b) 6 - 10d<br />
c) 8 - 16d<br />
d) 4 - 20d<br />
Answer: C<br />
Solution: Table 2304.9.1 #10.<br />
Question ID: 19039<br />
129.<br />
With few exceptions, not less than ______ studs shall be installed in every corner<br />
of an exterior wall.<br />
a) 1<br />
b) 2<br />
c) 3<br />
d) 4<br />
Answer: C<br />
Solution: 2308.9.2<br />
Question ID: 19040<br />
130.<br />
Attic spaces shall be provided with an interior access opening not less than _____<br />
by 30".<br />
a) 12"<br />
b) 20"<br />
c) 22"<br />
d) 24"<br />
© <strong>Contractors</strong> <strong>Institute</strong> 39<br />
March 2012
Answer: B<br />
Solution: 1209.2<br />
Question ID: 19041<br />
131.<br />
Rafters shall be framed directly opposite each other at the ridge. The ridge board<br />
shall be at least _______ in thickness.<br />
a) 1 inch<br />
b) 2 inches<br />
c) 1/2 inch<br />
d) 5/8 inch<br />
Answer: A<br />
Solution: 2308.10.4<br />
Question ID: 19042<br />
132.<br />
Where headers are provided over openings in exterior walls, each end of each<br />
header shall have a minimum end bearing of ____ for the full width of the header.<br />
a) 6 inches<br />
b) 4 inches<br />
c) 3 inches<br />
d) 1-1/2 inches<br />
Answer: D<br />
Solution: 2308.9.5.2<br />
Question ID: 19043<br />
133.<br />
For an opening 7'- 4" wide, each end of a double 2" x 12" header shall rest on<br />
_______ , when the exterior wall header supports only the roof and ceiling of a<br />
36' wide building.<br />
a) a single jack stud<br />
b) framing anchors attached to full height studs<br />
c) double jack studs at each end<br />
d) triple jack studs at each end<br />
Answer: C<br />
Solution: Table 2308.9.5, 36' w, roof & ceiling, 2- 2" x 12", max. 7'- 6" span NJ = 2<br />
Question ID: 19044<br />
© <strong>Contractors</strong> <strong>Institute</strong> 40<br />
March 2012
134.<br />
Which header will be required for an exterior wall when the building is 36 feet<br />
wide, the header supports the roof and ceiling only and the opening is 4 feet wide<br />
<br />
a) 2 - 2" x 6"<br />
b) 2 - 2" x 8"<br />
c) 2 - 2" x 10"<br />
d) 2 - 2" x 12"<br />
Answer: A<br />
Solution: Table 2308.9.5, 36' width, roof & ceiling, 2 - 2" x 6", max. 4'- 2" span<br />
Question ID: 19045<br />
135.<br />
Where preservative treated wood is used in enclosed locations where drying in<br />
service cannot readily occur, such wood shall be at a moisture content of ______<br />
or less before being covered.<br />
a) 12%<br />
b) 15%<br />
c) 19%<br />
d) 25%<br />
Answer: C<br />
Solution: 2303.1.8.2<br />
Question ID: 19046<br />
136.<br />
Wood girders located over a crawl space or unexcavated area within the periphery<br />
of a building shall be of approved naturally durable wood or preservative-treated<br />
wood when they are closer than _________ to exposed ground.<br />
a) 8"<br />
b) 12"<br />
c) 16"<br />
d) 18"<br />
Answer: B<br />
Solution: 2304.11.2.1<br />
Question ID: 19047<br />
© <strong>Contractors</strong> <strong>Institute</strong> 41<br />
March 2012
137.<br />
Draftstopping materials shall be not less than ____ wood structural panel or other<br />
approved materials adequately supported.<br />
a) 5/16"<br />
b) 3/8"<br />
c) 15/32"<br />
d) 3/4"<br />
Answer: B<br />
Solution: 717.3.1<br />
Question ID: 19048<br />
138.<br />
Where combustible members enter and terminate in a masonry fire wall, they<br />
must be separated from the opposite side of the wall _________ .<br />
a) by a 1/4" metal plate.<br />
b) by 1/2" cement board<br />
c) by 3" of air space<br />
d) by 4" of solid masonry<br />
Answer: D<br />
Solution: 706.7<br />
Question ID: 19049<br />
139.<br />
Joists framing from opposite sides of a beam, girder or partition shall be lapped at<br />
least ______ and fastened, or the opposing joists shall be tied together in an<br />
approved manner.<br />
a) 2"<br />
b) 3"<br />
c) 6"<br />
d) 2 feet<br />
Answer: B<br />
Solution: 2308.8.2 2nd paragraph<br />
Question ID: 19050<br />
© <strong>Contractors</strong> <strong>Institute</strong> 42<br />
March 2012
140.<br />
A wood structural panel has a panel span rating of 32 / 16 stamped on the back of<br />
the sheet. The 32 refers to the _________, whereas the 16 refers to the maximum<br />
span between floor members.<br />
a) maximum span between wall studs<br />
b) maximum spacing of wall studs<br />
c) maximum spacing of floor trusses<br />
d) maximum span between roof supports<br />
Answer: D<br />
Solution: Table 2304.7(3)<br />
Question ID: 19051<br />
141.<br />
Which of the following complies with the code requirement for exterior wall<br />
sheathing <br />
a) Particle board shall be no less than 5/16" for 24" o.c. studs<br />
b) Plywood shall be no less than 7/16" for 16" stud spacing.<br />
c) Wood boards shall have a minimum thickness of 5/8".<br />
d) Fiberboard shall not be less than 3/8" thick.<br />
Answer: C<br />
Solution: 2308.9.3 #2. #3. #4 #6. See Table 2308.9.3(4)<br />
Question ID: 19052<br />
142.<br />
Notches in the top or bottom of joists shall not be located in the middle ____ of<br />
the span.<br />
a) 1/2<br />
b) 1/3<br />
c) 1/4<br />
d) 1/6<br />
Answer: B<br />
Solution: 2308.8.2 2308.10.4.2<br />
Question ID: 19053<br />
© <strong>Contractors</strong> <strong>Institute</strong> 43<br />
March 2012
143.<br />
Openings into the attic space of any habitable building shall be covered with<br />
screening or hardware cloth to prevent the entry of birds, etc. Openings therein<br />
shall not exceed ___ .<br />
a) 1/8 inch<br />
b) 1/4 inch<br />
c) 1/2 inch<br />
d) 3/4 inch<br />
Answer: B<br />
Solution: 1203.2.1<br />
Question ID: 19054<br />
144.<br />
When toe nailing a stud to sole plate, the number and minimum nail size to be<br />
used is ___ .<br />
a) 2 - 16d<br />
b) 2 - 12d<br />
c) 2 - 10d<br />
d) 4 - 8d<br />
Answer: D<br />
Solution: Table 2304.9.1 #8<br />
Question ID: 19055<br />
145.<br />
3/4" plywood sub flooring shall be nailed with 6d or 8d commons, ______ o.c. at<br />
the edges.<br />
a) 4"<br />
b) 6"<br />
c) 7"<br />
d) 12"<br />
Answer: B<br />
Solution: Table 2304.9.1 #31 Location<br />
Question ID: 19056<br />
© <strong>Contractors</strong> <strong>Institute</strong> 44<br />
March 2012
146.<br />
Sheathing grade plywood with a 32/16 panel span rating is used as sub roofing<br />
with the face grain perpendicular to the supports and no edge support. The<br />
maximum rafter spacing shall be ______ on center.<br />
a) 12"<br />
b) 16"<br />
c) 28"<br />
d) 32"<br />
Answer: C<br />
Solution: Table 2304.7(3) Shtg. Grade 32/16 Without edge support 28"<br />
Question ID: 19057<br />
147.<br />
When installing 1/2" exterior plywood panel siding, nails should be __.<br />
a) 10d<br />
b) 8d<br />
c) 6d<br />
d) 4d<br />
Answer: C<br />
Solution: Table 2304.9.1 #32<br />
Question ID: 19058<br />
148.<br />
Determine the minimum header size required for the given opening in an exterior<br />
bearing wall that supports a roof and ceiling only. Southern Pine, 28 foot building<br />
width, 7'- 2" opening, 2 jack studs each side.<br />
a) 2 - 2" x 4"<br />
b) 2 - 2" x 6"<br />
c) 2 - 2" x 8"<br />
d) 2 - 2" x 10"<br />
Answer: D<br />
Solution: Table 2308.9.5 28' width cover 7'- 2" (7'-3") 2 NJ 2-2" x 10"<br />
Question ID: 19059<br />
© <strong>Contractors</strong> <strong>Institute</strong> 45<br />
March 2012
149.<br />
Determine the minimum header size required for the given opening in an exterior<br />
wall that supports a roof and ceiling only. Hem-Fir, 20 foot building width, 10'-<br />
0" opening, 1 jack stud each side.<br />
a) 2 - 2" x 12"<br />
b) 3 - 2" x 10"<br />
c) 3 - 2" x 12"<br />
d) 4 - 2" x 10"<br />
Answer: B<br />
Solution: Table 2308.9.5 20' width cover 10' (10' -6") 1 NJ 3-2" x 10"<br />
Question ID: 19060<br />
150.<br />
The maximum spacing of wood studs for interior non-bearing partitions is<br />
__________ .<br />
a) 16" o.c.<br />
b) 18" o.c.<br />
c) 24" o.c.<br />
d) 28" o.c.<br />
Answer: D<br />
Solution: 2308.9.2.3<br />
Question ID: 19061<br />
151.<br />
A project requires a wood structural panel shear wall having 510 pounds per<br />
linear foot of shear. The wall has no openings. The nail pattern is 10d at 4" o.c.<br />
Which is approved <br />
a) 15/32" Structural I<br />
b) 15/32" Sheathing, Plywood Siding<br />
c) 7/16" Oriented Strand Board<br />
d) 7/16" Medium Density Overlay<br />
Answer: A<br />
Solution: Table 2306.3 Str 1 15/32" 10d Under 4" oc 510 plf<br />
Question ID: 19062<br />
© <strong>Contractors</strong> <strong>Institute</strong> 46<br />
March 2012
152.<br />
Where floor joists or roof trusses are spaced more than 16" o.c. and the bearing<br />
studs are spaced 24" o.c., such joists or trusses shall bear within ___ of the studs<br />
beneath or a third plate shall be installed.<br />
a) 1 inch<br />
b) 4 inches<br />
c) 5 inches<br />
d) 6 inches<br />
Answer: C<br />
Solution: 2308.9.2.2<br />
Question ID: 19063<br />
153.<br />
The ratio of total net free ventilating area to ceiling area shall be not less than<br />
______ for gabled or hipped roofs. Assume attic has no vapor retarder or vents in<br />
the upper portion.<br />
a) 1/300<br />
b) 1/250<br />
c) 1/150<br />
d) 1/100<br />
Answer: A<br />
Solution: 1203.2<br />
Question ID: 19064<br />
154.<br />
Except when applied to concrete or masonry, exposed aggregate plaster shall be<br />
applied in not less than 2 coats to a minimum thickness of _____.<br />
a) 1/2"<br />
b) 5/8"<br />
c) 3/4"<br />
d) 7/8"<br />
Answer: D<br />
Solution: 2513.4<br />
Question ID: 19065<br />
© <strong>Contractors</strong> <strong>Institute</strong> 47<br />
March 2012
155.<br />
No plaster shall be applied until the lathing has been inspected and approved by<br />
the ___ .<br />
a) The Prime Contractor<br />
b) The <strong>Building</strong> Official<br />
c) The Architect or Engineer<br />
d) The Project Owner<br />
Answer: B<br />
Solution: 2503.1 110.3 (the extra .5 is a typographical error)<br />
Question ID: 19066<br />
156.<br />
When constructing a horizontal gypsum board ceiling diaphragm, the maximum<br />
spacing of framing members shall be ______ on center.<br />
a) 12"<br />
b) 16"<br />
c) 19.2"<br />
d) 24"<br />
Answer: D<br />
Solution: Table 2508.5<br />
Question ID: 19067<br />
157.<br />
Flat plastic skylights shall have a slope of at least _________ .<br />
a) 2:12<br />
b) 3:12<br />
c) 4:12<br />
d) 5:12<br />
Answer: C<br />
Solution: 2610.3<br />
Question ID: 19069<br />
158.<br />
Chimneys shall extend at least ________ feet above the highest point where they<br />
pass through the roof of the building and at least two feet higher than any portion<br />
of the roof or building located within 10 feet horizontally.<br />
a) 2'<br />
b) 3'<br />
c) 4'<br />
d) 5'<br />
© <strong>Contractors</strong> <strong>Institute</strong> 48<br />
March 2012
Answer: B<br />
Solution: 2113.9<br />
Question ID: 19070<br />
159.<br />
The maximum height or thickness of a marquee measured vertically from its<br />
lowest to its highest point shall not exceed ______. Assume the marquee projects<br />
one-half the distance from the property line to the curb line.<br />
a) 3 feet<br />
b) 6 feet<br />
c) 8 feet<br />
d) 9 feet<br />
Answer: D<br />
Solution: 3106.2 (3' if more than 2/3 distance) (9' if less than 2/3 distance)<br />
Question ID: 19072<br />
160.<br />
Regarding the temporary use of streets and obstructions placed near them,<br />
construction materials shall not be located within _______ of a street intersection.<br />
a) 10'<br />
b) 15'<br />
c) 20'<br />
d) 50'<br />
Answer: C<br />
Solution: 3308.1.1<br />
Question ID: 19073<br />
161.<br />
Walkways over excavated areas shall be made of boards not less than 2" nominal<br />
dimension designed to support a load of not less than ____ psf.<br />
a) 100<br />
b) 125<br />
c) 150<br />
d) 175<br />
Answer: C<br />
Solution: 3306.2<br />
Question ID: 19074<br />
© <strong>Contractors</strong> <strong>Institute</strong> 49<br />
March 2012
162.<br />
Every excavation on a site located 5 feet or less from the street lot line shall be<br />
enclosed with a barrier not less than ________ high.<br />
a) 4 feet<br />
b) 5 feet<br />
c) 6 feet<br />
d) 8 feet<br />
Answer: C<br />
Solution: 3306.9<br />
Question ID: 19075<br />
163.<br />
If a permit fee is $460.00 for the first $100,000 of valuation and $3.00 per<br />
thousand thereafter, the permit fee for a project with a valuation of $450,000<br />
would be _____ .<br />
a) $460.00<br />
b) $1,510.00<br />
c) $1,810.00<br />
d) $1,825.00<br />
Answer: B<br />
Solution: Math<br />
Question ID: 19076<br />
164.<br />
Each operator of an ATM or automated teller machine shall provide lighting<br />
during the hours of darkness. The intensity of the lighting at the face of the ATM<br />
shall be ______________________________. (*R)<br />
a) 2 footcandle<br />
b) 10 footcandle<br />
c) 50 footcandle<br />
d) provided by reflective mirrors only<br />
Answer: B<br />
Solution: 3112.2 1. 4.<br />
Question ID: 19077<br />
© <strong>Contractors</strong> <strong>Institute</strong> 50<br />
March 2012
165.<br />
According to <strong>Florida</strong> <strong>Building</strong> <strong>Code</strong>, all swimming pools shall be completely<br />
enclosed by a fence at least 4 feet in height. Openings in the fence shall not permit<br />
the passage of a sphere __________ inches (maximum) in diameter.<br />
a) 2<br />
b) 3<br />
c) 4<br />
d) 6<br />
Answer: C<br />
Solution: 424.2.17.1.2<br />
Question ID: 19078<br />
166.<br />
According to <strong>Florida</strong> <strong>Building</strong> <strong>Code</strong>, The minimum distance between any two<br />
required inlets in a private pool shall be _________ feet. (*R *B)<br />
a) 5<br />
b) 10<br />
c) 20<br />
d) 25<br />
Answer: B<br />
Solution: 424.2.21.5<br />
Question ID: 19079<br />
167.<br />
According to <strong>Florida</strong> <strong>Building</strong> <strong>Code</strong>, All pool piping shall be tested and proven<br />
tight under a static water or air pressure test of _____ psi minimum for 15<br />
minutes. (*R *B)<br />
a) 20<br />
b) 30<br />
c) 35<br />
d) 45<br />
Answer: C<br />
Solution: 424.2.12.1<br />
Question ID: 19080<br />
© <strong>Contractors</strong> <strong>Institute</strong> 51<br />
March 2012
168.<br />
According to <strong>Florida</strong> <strong>Building</strong> <strong>Code</strong>, A ladder or steps is not required at the<br />
shallow end of a pool that has a maximum depth of _________ inches.<br />
a) 24<br />
b) 27<br />
c) 30<br />
d) 36<br />
Answer: A<br />
Solution: 424.2.18<br />
Question ID: 19081<br />
169.<br />
According to <strong>Florida</strong> <strong>Building</strong> <strong>Code</strong>, The maximum mesh size of a chain link<br />
fence shall be _____ inch square. Assume no slats. Assume fence surrounds a<br />
private pool.<br />
a) 1 ¼<br />
b) 1 ½<br />
c) 2 ¼<br />
d) 3<br />
Answer: C<br />
Solution: 424.2.17.1.6<br />
Question ID: 19082<br />
170.<br />
Safety glazing shall be required in hazardous locations such as a shower<br />
enclosure. Such safety glazing shall be required when the bottom exposed edge is<br />
less than ______ above a standing surface. Assume building wall enclosing this<br />
compartment.<br />
a) 24"<br />
b) 36"<br />
c) 48"<br />
d) 60"<br />
Answer: D<br />
Solution: 2406.4 5.<br />
Question ID: 19083<br />
© <strong>Contractors</strong> <strong>Institute</strong> 52<br />
March 2012
171.<br />
According to the <strong>Florida</strong> <strong>Building</strong> <strong>Code</strong>, <strong>Building</strong>, an application for a permit for<br />
any proposed work shall be deemed to have been abandoned ______ after the date<br />
of filing.<br />
a) 30 days<br />
b) 90 days<br />
c) 180 days<br />
d) 365 days<br />
Answer: C<br />
Solution: 105.3.2<br />
Question ID: 19084<br />
172.<br />
According to <strong>Florida</strong> <strong>Building</strong> <strong>Code</strong>, The maximum floor slope from the shallow<br />
end to the deep end of a 5' deep pool without an approved diving configuration<br />
shall be 1 foot in ______ feet.<br />
a) 10<br />
b) 12<br />
c) 20<br />
d) 40<br />
Answer: A<br />
Solution: 424.1.2.2.3.1<br />
Question ID: 19085<br />
173.<br />
According to <strong>Florida</strong> <strong>Building</strong> <strong>Code</strong>, private sanitary facilities located in motel<br />
living units and accessible within a ____ foot maximum radius from the nearest<br />
pool waters edge may be used instead of facilities at the pool.<br />
a) 75<br />
b) 150<br />
c) 200<br />
d) 250<br />
Answer: C<br />
Solution: 424.1.6.1 Exception:<br />
Question ID: 19086<br />
© <strong>Contractors</strong> <strong>Institute</strong> 53<br />
March 2012
174.<br />
According to <strong>Florida</strong> <strong>Building</strong> <strong>Code</strong>, a perimeter overflow system shall be<br />
capable of carrying at least __________ percent of the recirculation flow. (*R *B)<br />
a) 40<br />
b) 60<br />
c) 75<br />
d) 100<br />
Answer: D<br />
Solution: 424.1.6.5.3<br />
Question ID: 19087<br />
175.<br />
According to <strong>Florida</strong> <strong>Building</strong> <strong>Code</strong>, the maximum riser height for a stair leading<br />
into a pool is ____.<br />
a) 7"<br />
b) 8"<br />
c) 9"<br />
d) 10"<br />
Answer: D<br />
Solution: 424.1.2.5.3<br />
Question ID: 19088<br />
176.<br />
According to <strong>Florida</strong> <strong>Building</strong> <strong>Code</strong>, food or drink service facilities shall not be<br />
located within ____ feet of the waters edge of a public swimming pool.<br />
a) 4<br />
b) 10<br />
c) 12<br />
d) 15<br />
Answer: C<br />
Solution: 424.1.3.1.7<br />
Question ID: 19089<br />
177.<br />
According to <strong>Florida</strong> <strong>Building</strong> <strong>Code</strong>, overhead lighting shall provide a minimum<br />
of ___ foot candles of illumination at the pool water surface and the pool deck<br />
surface for outdoor pools that are used at night.<br />
a) 3<br />
b) 5<br />
c) 10<br />
d) 15<br />
© <strong>Contractors</strong> <strong>Institute</strong> 54<br />
March 2012
Answer: A<br />
Solution: 424.1.4.2.1<br />
Question ID: 19090<br />
178.<br />
According to <strong>Florida</strong> <strong>Building</strong> <strong>Code</strong>, the maximum spacing between weir<br />
openings in a perimeter overflow skimmer system is _____, if 2" diameter piping<br />
is used. (*R *B)<br />
a) 8 feet<br />
b) 10 feet<br />
c) 15 feet<br />
d) 20 feet<br />
Answer: B<br />
Solution: 424.1.6.5.3.1<br />
Question ID: 19092<br />
179.<br />
A building official is authorized to issue a permit for temporary structures and<br />
uses. Such permit is valid for not more than _______.<br />
a) 30 days<br />
b) 90 days<br />
c) 120 days<br />
d) 180 days<br />
Answer: D<br />
Solution: 108.1<br />
Question ID: 19093<br />
180.<br />
In conventional light-frame construction, what is the maximum bearing wall<br />
floor-to-floor height<br />
a) 8’<br />
b) 11’ - 7"<br />
c) 12’<br />
d) 14’<br />
Answer: B<br />
Solution: FBC <strong>Building</strong>, 2308.2 Limitations 2.<br />
Question ID: 19095<br />
© <strong>Contractors</strong> <strong>Institute</strong> 55<br />
March 2012
181.<br />
As per <strong>Florida</strong> <strong>Building</strong> <strong>Code</strong>, the use of rebar with rust or mill scale would be<br />
acceptable if the surface condition complied with __________.<br />
a) ACI 318, Section 7.2<br />
b) ACI 318, Section 7.3<br />
c) ACI 318, Section 7.4<br />
d) ACI 318, Section 7.5<br />
Answer: C<br />
Solution: 1907.4<br />
Question ID: 19096<br />
182.<br />
Prior to plan review and issuance of a building permit, a building official may<br />
issue a permit for:<br />
a) temporary structures.<br />
b) digging of footings and foundations<br />
c) site work<br />
d) permanent electrical power to the site<br />
Answer: A<br />
Solution: 108.1<br />
Question ID: 19097<br />
183.<br />
A sunroom addition is defined as a one story structure added to an existing<br />
dwelling with an open or glazed area ______ of the gross area of its exterior walls<br />
and roof.<br />
a) 40 percent<br />
b) up to 40 percent<br />
c) in excess of 40 percent<br />
d) 40 percent or more<br />
Answer: C<br />
Solution: 202 Definitions, look under S, 1202.1<br />
Question ID: 19098<br />
184.<br />
According to the <strong>Florida</strong> <strong>Building</strong> <strong>Code</strong>, When emergency repair work is<br />
performed, the application for permit must be submitted ___________.<br />
a) before the work begins<br />
b) within the next working business day<br />
c) within the next 72 hours<br />
d) within the next 2 working business days<br />
© <strong>Contractors</strong> <strong>Institute</strong> 56<br />
March 2012
Answer: B<br />
Solution: FBC 105.2.1 Emergency repairs<br />
Question ID: 19099<br />
185.<br />
According to the <strong>Florida</strong> <strong>Building</strong> <strong>Code</strong>, compacted fill less than 12 inches in<br />
depth need not comply with an approved report, provided it has been compacted<br />
to a minimum of ________.<br />
a) 80%<br />
b) 85%<br />
c) 90%<br />
d) 95%<br />
Answer: C<br />
Solution: FBC 1804.5 Compacting fill material Exception<br />
Question ID: 19100<br />
186.<br />
Steel studs in gable endwalls shall be _____ for special wind provisions.<br />
a) limited to 8 feet in height<br />
b) structurally continuous between points of lateral support<br />
c) sheathed with panels having a 6:1 L/W ratio<br />
d) a minimum of 25 mils in thickness<br />
Answer: B<br />
Solution: 2211.1<br />
Question ID: 19101<br />
187.<br />
Steel studs in gable endwalls adjacent to cathedral ceilings shall be continuous<br />
from the uppermost floor to the ___________________.<br />
a) ceiling diaphragm only<br />
b) roof diaphragm only<br />
c) ceiling diaphragm or to the roof diaphragm<br />
d) sill plate of the kneewall above<br />
Answer: C<br />
Solution: 2211.2<br />
Question ID: 19102<br />
© <strong>Contractors</strong> <strong>Institute</strong> 57<br />
March 2012
188.<br />
What is the minimum fire resistance rating required for a column in a building of<br />
Type VA construction<br />
a) 1 hour<br />
b) 2 hours<br />
c) 3 hours<br />
d) 4 hours<br />
Answer: A<br />
Solution: Table 601, Columns, Type VA<br />
Question ID: 19104<br />
189.<br />
Face nailing of joist to band joist must be made with a minimum of:<br />
a) three 16d nails<br />
b) four 16d nails<br />
c) three 18d nails<br />
d) four 18d nails<br />
Answer: A<br />
Solution: TABLE 2304.9.1<br />
Question ID: 19109<br />
190.<br />
End joints in double top plates shall be offset at least _____ and shall be nailed<br />
with not less than eight 16d face nails on each side of the joist.<br />
a) 24 inches<br />
b) 32 inches<br />
c) 36 inches<br />
d) 48 inches<br />
Answer: D<br />
Solution: 2308.9.2.1 Top plates<br />
Question ID: 19110<br />
191.<br />
In conventional framing, what size header would be used when installing a 3’- 6”<br />
wide window in a single story building which is 36’ wide.<br />
a) 2 – 2 x 4<br />
b) 2 – 2 x 6<br />
c) 2 – 2 x 8<br />
d) 2 – 2 x 10<br />
© <strong>Contractors</strong> <strong>Institute</strong> 58<br />
March 2012
Answer: B<br />
Solution: TABLE 2308.9.5<br />
HEADER AND GIRDER SPANS FOR EXTERIOR BEARING WALLS<br />
Roof and Ceiling, 36' width, Span up to 4'- 2"<br />
Question ID: 19111<br />
© <strong>Contractors</strong> <strong>Institute</strong> 59<br />