Anti-glare<br />
Series<br />
<strong>ET</strong> <strong>MODULE</strong><br />
<strong>Monocrystalline</strong><br />
<strong>ET</strong>-M572200WW 200W<br />
Features<br />
Specially developed for projects near highway,<br />
railway, airport and similar applications with strict<br />
anti-glare requirements<br />
High module conversion efficiency through superior<br />
manufacturing technology<br />
0 to +5W positive tolerance for mainstream products<br />
Withstand high wind loads and snow loads (5400Pa)<br />
Anodized aluminum improving corrosion resistance<br />
Highly transparent, low iron tempered glass<br />
Excellent performance under low light conditions<br />
Benefits<br />
25-year linear performance warranty;<br />
10-year warranty on materials and workmanship<br />
Product liability insurance<br />
Local technical support<br />
Local warehousing<br />
48 hour-response service<br />
Enhanced design for easy installation and longterm<br />
reliability<br />
100%<br />
97%<br />
ADDED VALUE FROM WARRANTY<br />
Linear performance warranty from <strong>ET</strong> <strong>Solar</strong><br />
Standard tiered warranty<br />
90%<br />
81.4%<br />
80%<br />
0%<br />
1 5 10 15 20 25<br />
years<br />
IEC 61215 Ed.2<br />
IEC 61730<br />
IEC 61701<br />
BABT8510<br />
The DLG certificate is estimated to be received in April<br />
M/<strong>ET</strong>-SPS-EN-EU2012V2-F
ELECTRICAL SPECIFICATIONS<br />
Model Type<br />
Peak Power (Pmax)<br />
Module Efficiency<br />
Maximum Power Voltage (Vmp)<br />
Maximum Power Current (Imp)<br />
Open Circuit Voltage (Voc)<br />
Short Circuit Current (Isc)<br />
Power Tolerance<br />
Maximum System Voltage<br />
Normal Operating Cell Temperature<br />
Series Fuse Rating (A)<br />
Number of Bypass Diode<br />
<strong>ET</strong>-M572200WW<br />
200W<br />
15.67%<br />
36.97V<br />
5.41A<br />
45.84V<br />
5.70A<br />
-1% to+3%<br />
VDC 1000<br />
44.4±2<br />
15A<br />
3<br />
MECHANICAL SPECIFICATIONS<br />
PHYSICAL CHARACTERISTICS<br />
Unit:mm (inch)<br />
40 (1.57)<br />
21± 1<br />
11<br />
Cell type<br />
125mm x 125mm<br />
21± 1<br />
50<br />
1000 W/m 2 800 W/m2 600 W/m2 400 W/m2 200 W/m2 8<br />
8<br />
Number of cells<br />
72 cells in series<br />
11<br />
4<br />
Weight<br />
15.76kg (33.74 lbs)<br />
1580×808×40 mm<br />
Junction box<br />
Dimensions<br />
(62.20×31.81×1.57 inch)<br />
Max Load<br />
5400Pascals ( 112 lb/ft 2 )<br />
8-14×9<br />
(0.55×0.35)<br />
TEMPERATURE COEFFICIENT<br />
4-φ 4<br />
cable(-) cable(+)<br />
Temp. Coeff. of Isc (TK Isc)<br />
0.042 %/<br />
Temp. Coeff. of Voc (TK Voc)<br />
-0.336 %/<br />
Temp. Coeff. of Pmax (TK Pmax) -0.47 %/<br />
35(1.38)<br />
808(31.81)<br />
770(30.30)<br />
808(31.81)<br />
ELECTRICAL CHARACTERISTICS<br />
Electrical performance<br />
Temperature dependence of Isc,<br />
Irradiance dependence of Isc,<br />
(cell temperature:25 )<br />
Voc and Pmax<br />
Voc and Pmax (cell temperature:25<br />
7<br />
210 120<br />
100<br />
Voc<br />
6<br />
190.2W<br />
180<br />
I SC<br />
100<br />
80<br />
5<br />
150.8W<br />
150<br />
80<br />
Voc<br />
4<br />
111.4W<br />
120<br />
Pmax<br />
60<br />
60<br />
3<br />
90<br />
40<br />
72.2W<br />
40<br />
2<br />
60<br />
I SC<br />
Temp.Coeff.of Isc =+0.042%/<br />
33.6W<br />
Pmax<br />
Temp.Coeff.of Voc =-0.336%/<br />
20<br />
1<br />
30<br />
20<br />
Temp.Coeff.of Pmax=-0.47%/<br />
0<br />
0<br />
0<br />
0<br />
0 10 20 30 40 50<br />
- 25 0 25 50 75 100 0 200 400 600 800 1000<br />
Voltage [V]<br />
Cell Temperature ( ) Irradiance (W/m 2 )<br />
Current(A)<br />
Power(W)<br />
Normalize Isc,Voc and Pmax(%)<br />
1580(62.20)<br />
Normalize Isc,Voc and Pmax(%)<br />
50<br />
4<br />
0<br />
-30'<br />
45°<br />
17.5<br />
1000(39.37)<br />
10<br />
800(31.50)<br />
1300(51.19)<br />
1580(62.20)<br />
Note: the specifications are obtained under the Standard Test Conditions (STCs): 1000 W/m 2 o<br />
solar irradiance, 1.5 Air Mass, and cell temperature of 25 C.<br />
The NOCT is obtained under the Test Conditions : 800 W/m 2 , 20°C ambient temperature, 1 m/s wind speed, AM 1.5 spectrum.