50HZ<br />

Specifications for RENTAL POWER<br />

from 15 kVA to 700 kVA<br />

50HZ<br />

50HZ<br />

R16C<br />

Full <strong>Rental</strong> <strong>Power</strong> Version<br />

R66C2<br />

Full <strong>Rental</strong> <strong>Power</strong> Version<br />

R110C2<br />

Full <strong>Rental</strong> <strong>Power</strong> Version<br />

R220C2<br />

Full <strong>Rental</strong> <strong>Power</strong> Version<br />

R350C2<br />

Full <strong>Rental</strong> <strong>Power</strong> Version<br />

R450C2<br />

Full <strong>Rental</strong> <strong>Power</strong> Version<br />

10<br />

SDMO part no. R16C R22C2 R33C2 R44C2 R66C2 R90C2 R110C2 R135C2<br />

Generating set<br />

PRP (1) in kVA (400V) 15 20 30 40 60 80 100 120<br />

Prime power cos phi=0.8 (kW) 400V 12 16 24 32 48 64 80 96<br />

ESP (2) in kVA 16 22 33 42 66 88 110 132<br />

Emergency power (kW cos phi=0.8) 13 18 26 34 53 70 88 106<br />

Sound level (dBA) @ 1 metre 71 72 74 73 73 77 77 77<br />

Sound level (dBA) @ 7 metres 61 62 64 63 63 67 67 67<br />

Sound level in Lwa 87 87 91 92 93 94 95 93<br />

Alternator<br />

Make Leroy Somer Leroy Somer Leroy Somer Leroy Somer Leroy Somer Leroy Somer Leroy Somer Leroy Somer<br />

Model LSA422S4 LSA422S5 LSA422L9 LSA432S15 LSA432M45 LSA432L8 LSA442VS45 LSA442S7<br />

Engine / 1500 rpm<br />

Make Mitsubishi Mitsubishi Mitsubishi Mitsubishi John Deere John Deere John Deere John Deere<br />

Model S4L2-61SD S4Q2-Z261SD S4S-Z263SD S4S-Z2DT62SD 4045TFS70 4045HFS72 4045HFS73 6068HFS72<br />

Prime output (kW) 13.7 19.6 27.3 36 53 72.5 91.5 109<br />

Number of cylinders 4 4 4 4 4 4 4 6<br />

Auxiliary voltage 12 12 12 12 12 12 12 12<br />

Cubic capacity 1.75 2.5 3.33 3.33 4.48 4.48 4.48 6.72<br />

Bore 78 88 94 94 106 106 106 106<br />

Stroke 92 103 120 120 127 127 127 127<br />

Fuel / Cooling Diesel / Water Diesel / Water Diesel / Water Diesel / Water Diesel / Water Diesel / Water Diesel / Water Diesel / Water<br />

Fuel<br />

Capacity of standard tank in L 50 100 100 100 180 190 190 340<br />

Capacity of high autonomy tank in L 93 230 230 230 390 505 505 868<br />

Autonomy with standard fuel tank (in hours)<br />

at 100% load 11.4 15.6 11.4 9.8 12.2 9.8 8.0 12.3<br />

at 75% load 14.7 20.8 15.2 13.0 16.0 12.9 10.6 16.0<br />

at 50% load 19.2 29.4 20.8 18.9 24.3 19.1 15.3 23.8<br />

Autonomy with large autonomy fuel tank (in<br />

hours)<br />

at 100% load 20.9 32.3 23.5 20.3 23.8 22.5 18.1 26.0<br />

at 75% load 24.6 43.1 31.4 26.9 31.2 29.4 23.7 34.1<br />

at 50% load 32.2 60.9 43.1 39.1 47.4 44.7 36.0 51.9<br />

Dimensions with standard chassis M126 M127 M128 M129 M226<br />

Overall length (in mm) 1750 2080 2080 2080 2300 2554 2554 3508<br />

Overall width (in mm) 715 960 960 960 1080 1170 1170 1200<br />

Overall height (in mm) 1230 1415 1415 1415 1680 1680 1680 1830<br />

Weight in running order (in kg) 664 950 1010 1040 1670 1890 1955 2525<br />

Off load weight (in kg) 610 835 910 930 1470 1700 1765 2175<br />

Dimensions with double wall chassis M126 M127 M128 M129 M226<br />

Overall length (in mm) 1797 2160 2160 2160 2344 2602 2602 3560<br />

Overall width (in mm) 775 966 966 966 1080 1170 1170 1200<br />

Overall height (in mm) 1391 1582 1582 1582 1900 1900 1900 2182<br />

Weight in running order (in kg) 762 1191 1320 1350 2090 2500 2560 3501<br />

Off load weight (in kg) 672 961 1100 1120 1700 1990 2050 2618<br />

R165C2 R220C2 R275C2 R350C2 R450C2 R550C2 R630C2 R700C2<br />

150 200 250 315 400 500 573 636<br />

120 160 200 252 320 400 458 560<br />

165 220 275 350 440 550 630 700<br />

132 176 220 280 352 440 504 504<br />

77 78 78 77 80 78 81 85<br />

67 68 68 67 70 68 71 75<br />

95 96 97 97 96 97 100 105<br />

Leroy Somer Leroy Somer Leroy Somer Leroy Somer Leroy Somer Leroy Somer Leroy Somer Leroy Somer<br />

LSA442M95 LSA462M5 LSA462L6 LSA462VL12 LSA472VS3 LSA472M7 LSA472L9 LSA491S4<br />

John Deere Volvo Volvo Volvo Volvo Volvo Volvo Volvo<br />

6068HFS73 TAD733GE TAD734GE TAD941GE TAD1242GE TAD1641GE TAD1642GE TWD1643GE<br />

136 179 220 280 352 430 485 536<br />

6 6 6 6 6 6 6 6<br />

12 12 24 24 24 24 24 24<br />

6.72 7.15 7.15 9.36 12.1 16.1 16.1 16.1<br />

106 108 108 120 131 144 144 144<br />

127 130 130 138 150 165 165 165<br />

Diesel / Water Diesel / Water Diesel / Water Diesel / Water Diesel / Water Diesel / Water Diesel / Water Diesel / Water<br />

340 340 390 470 470 500 610 610<br />

868 868 950 1368 1368 1770 1950 1950<br />

10.2 8.0 7.3 6.9 5.8 4.9 5.3 4.3<br />

13.4 10.7 9.2 9.3 7.9 6.6 7.2 6.5<br />

19.3 16.0 12.8 13.4 11.6 9.8 10.7 8.7<br />

20.9 18.3 16.0 17.2 15.1 15.6 15.1 13.7<br />

27.4 24.7 20.1 23.6 20.7 21.1 20.6 20.6<br />

41.7 36.6 28.1 31.7 30.4 31.2 30.7 27.8<br />

M226 M227 M228 M229 M230<br />

3508 3508 4004 4475 4475 5031 5031 5031<br />

1200 1200 1380 1410 1560 1560 1690 1690<br />

1830 1830 2125 2430 2430 2435 2662 2662<br />

2580 2740 3590 4300 4840 5410 5940 6090<br />

2230 2390 3200 3830 4360 4870 5300 5410<br />

M226 M227 M228 M229 M230<br />

3560 3560 4056 4527 4527 5083 5083 5083<br />

1200 1200 1380 1410 1410 1560 1690 1690<br />

2182 2182 2437 2780 2780 2780 2922 2922<br />

3560 3750 4520 5887 6236 7290 7930 7980<br />

2680 2920 3650 4519 4868 5650 5850 6140<br />

EVENT<br />

Concept<br />

SDMO is offering generating<br />

sets specially designed for<br />

use at functions; the EVENT<br />

range.<br />

These generating sets benefit<br />

from all the same features as<br />

<strong>Rental</strong> <strong>Power</strong> generating sets,<br />

whilst offering an especially<br />

reduced sound level suited to<br />

the specific requirements od<br />

this type of usage.<br />

Please contact your<br />

commercial sales<br />

department for<br />

further information.<br />

(1) PRP: Main power available continuously under variable load for an unlimited number of hours annually, in accordance with ISO 8528-1, an overload of 10% one hour every 12 hours is available in<br />

accordance with ISO 3046-1<br />

(2) ESP: Emergency Standby <strong>Power</strong> available for supplying emergency power in variable load applications in accordance with ISO 8528-1, no overload available for this service.<br />