TRANSFORMERS/SERIES INSTALLATION UNITS Bell transformers<br />
Safety transformers (up to 18 VA)<br />
48<br />
GT 1975<br />
GT 36 AP<br />
Safety transformers (up to 25 VA)<br />
GT 1973<br />
GT 54 AP<br />
Safety transformers (up to 63 VA)<br />
GT 1990<br />
GT 90 AP<br />
Description<br />
Installation in electrical distributor/flat distributor, tested<br />
according to EN61558<br />
Short-circuit resistance through PTC, suitable for continuous load<br />
Meets the most stringent environmental requirements<br />
Certified by VDE and KEMA, identified by ENEC mark for use<br />
throughout Europe<br />
Technical data<br />
Primary: 230–240 V~ (50 Hz)<br />
90 x 36 x 55 mm (corresponds to 2 installation modules)<br />
Note<br />
Higher output voltage at low loads or no load!<br />
Following a short circuit, start-up is to be performed by<br />
briefly disconnecting the primary side from the mains<br />
Accessories for surface-mount installation set<br />
Incl. two covering caps for IP 20<br />
Incl. clamping rail and material for surface-mount installation<br />
Model Order no. Description Technical data<br />
GT 1965 14102 Safety transformer 8 V~ (2.0 A)<br />
GT 1975 14101 Safety transformer 12 V~ (1.5 A)<br />
GT 36 AP 14936 Surface-mount installation set<br />
Description<br />
Installation in electrical distributor/flat distributor<br />
Suitable for continuous load, short-circuit resistance through PTC<br />
Meets the most stringent environmental requirements<br />
Tested according to EN61558<br />
Certified by VDE and KEMA, identified by ENEC mark for use<br />
throughout Europe<br />
Technical data<br />
Primary: 230 V~ (50 Hz)<br />
90 x 54 x 55 mm (corresponds to 3 installation modules)<br />
Description<br />
Installation in electrical distributor/flat distributor<br />
Short-circuit resistance through PTC<br />
Suitable for continuous load<br />
Meets the most stringent environmental requirements<br />
Tested according to EN 61558<br />
Certified by VDE and KEMA, identified by ENEC mark for use<br />
throughout Europe<br />
Technical data<br />
Primary: 230 V~ (50 Hz)<br />
90 x 90 x 55 mm (corresponds to 5 installation modules)<br />
Note<br />
Higher output voltage at low loads or no load!<br />
Following a short circuit, start-up is to be performed by<br />
briefly disconnecting the primary side from the mains<br />
Accessories for surface-mount installation set<br />
Incl. two covering caps for IP 20<br />
Incl. clamping rail and material for surface-mount installation<br />
Model Order no. Description Technical data<br />
GT 1973 14034 Safety transformer 8/12 V~ (2.0/2.0 A)<br />
GT 54 AP 14954 Surface-mount installation set<br />
Note<br />
Higher output voltage at low loads or no load!<br />
The secondary windings with cable links are to be connected<br />
in series or parallel (see type label) depending on the<br />
selected output voltage<br />
Following a short circuit, start-up is to be performed by<br />
briefly disconnecting the primary side from the mains<br />
Accessories for surface-mount installation set<br />
Incl. two covering caps for IP 20<br />
Incl. clamping rail and material for surface-mount installation<br />
Model Order no. Description Technical data<br />
GT 1980 14140 Safety transformer 12/16/24/32 V~ (3.3/2.5/1.6/1.2 A)<br />
GT 1990 14160 Safety transformer 12/24 V~ (5.2/2.6 A)<br />
GT 90 AP 14990 Surface-mount installation set