4. Filling the boiler<br />
Important: Regularly check that the pressure displayed by the pressure gauge (11) is 1 to 1.5 bar, with<br />
boiler not operating. In case of overpressure, open the boiler drain valve.<br />
In case the pressure is lower open the boiler filling tap (Figure 5a or 5b).<br />
We recommend you open the tap very slowly in order to let off the air.<br />
In case pressure drops occur frequently have the boiler checked by a Qualified Service Engineer.<br />
LUNA HT 280 - HT 330<br />
020503_0400<br />
Boiler filling tap<br />
Boiler drain valve<br />
Figure 5a<br />
LUNA HT 1.120 - HT 1.240 - HT 1.280<br />
0010270500<br />
Figure 5b<br />
Boiler filling tap<br />
The boiler is equipped with a hydraulic differential pressure switch that will inhibit the operation of<br />
the boiler in the event of the pump seizing or running dry.<br />
5. Turning off the boiler<br />
To shut down the boiler switch off the electrical supply to the appliance.<br />