4. Filling the boiler<br />

Important: Regularly check that the pressure displayed by the pressure gauge (11) is 1 to 1.5 bar, with<br />

boiler not operating. In case of overpressure, open the boiler drain valve.<br />

In case the pressure is lower open the boiler filling tap (Figure 5a or 5b).<br />

We recommend you open the tap very slowly in order to let off the air.<br />

In case pressure drops occur frequently have the boiler checked by a Qualified Service Engineer.<br />

LUNA HT 280 - HT 330<br />

020503_0400<br />

Boiler filling tap<br />

Boiler drain valve<br />

Figure 5a<br />

LUNA HT 1.120 - HT 1.240 - HT 1.280<br />

0010270500<br />

Figure 5b<br />

Boiler filling tap<br />

The boiler is equipped with a hydraulic differential pressure switch that will inhibit the operation of<br />

the boiler in the event of the pump seizing or running dry.<br />

5. Turning off the boiler<br />

To shut down the boiler switch off the electrical supply to the appliance.<br />