<strong>SIPROTEC</strong> 5<br />

© <strong>Siemens</strong> AG 2013. All rights reserved.


<strong>Siemens</strong> <strong>Protection</strong> Portfolio<br />

for all areas of application<br />

Generation<br />

Transmission<br />

Distribution<br />

Industry<br />

<strong>SIPROTEC</strong> 4<br />

<strong>SIPROTEC</strong> 4<br />

<strong>SIPROTEC</strong> 5<br />

<strong>SIPROTEC</strong> 4<br />

<strong>SIPROTEC</strong><br />

Compact<br />

Reyrolle<br />

<strong>SIPROTEC</strong> Easy<br />

<strong>SIPROTEC</strong> 4<br />

<strong>SIPROTEC</strong><br />

Compact<br />

Reyrolle<br />

<strong>SIPROTEC</strong> Easy<br />

Page 2<br />

Smart Grid Division<br />

Infrastructure & Cities Sector – Smart Grid Division<br />

© <strong>Siemens</strong> AG 2013. All rights reserved.


<strong>SIPROTEC</strong>: Highest-measured MTBF<br />

<strong>Siemens</strong> <strong>SIPROTEC</strong> Reliability<br />

Other vendors: 1 failure / year every 100-300 units *<br />

<strong>Siemens</strong> <strong>SIPROTEC</strong>: 1 failure / year every 600 units in average<br />

* Others may not include initial product failures<br />

Measured MTBF (years) for <strong>SIPROTEC</strong> Family<br />

1,400.00<br />

1,200.00<br />

1,000.00<br />

800.00<br />

600.00<br />

400.00<br />

7SD6 Differential<br />

7SA5 Distance<br />

7UT5 Transformer<br />

7SJ6 Feeder<br />

200.00<br />

0.00<br />

2004 2005 2006 2007 2008 2009 2010<br />

Page 3<br />

Smart Grid Division<br />

Infrastructure & Cities Sector – Smart Grid Division<br />

© <strong>Siemens</strong> AG 2013. All rights reserved.


<strong>SIPROTEC</strong>: Highest Relay Software Stability<br />

16<br />

14<br />

12<br />

10<br />

8<br />

6<br />

4<br />

2<br />

0<br />

# of Upgrades per Year<br />

2005 2006 2007 2008 2009 2010 2011 2012<br />

Frequent updates<br />

89 upgrades in 8 years<br />

USA Market<br />

SIEMENS<br />

Very Stable<br />

8 upgrades in 8 years<br />

When software is stable, only addition of features cause new releases (1/year).<br />

Frequent firmware updates cause serious time consumption and additional cost in maintenance, besides reliability concerns.<br />

Page 4<br />

Smart Grid Division<br />

Infrastructure & Cities Sector – Smart Grid Division<br />

© <strong>Siemens</strong> AG 2013. All rights reserved.


<strong>SIPROTEC</strong> 5: Innovation Highlights<br />

Page 5<br />

Smart Grid Division<br />

Infrastructure & Cities Sector – Smart Grid Division<br />

© <strong>Siemens</strong> AG 2013. All rights reserved.


<strong>SIPROTEC</strong> 5: Perfect Tailored Fit<br />

Base Modules Front Panels / HMI Expansion Modules Communication Modules<br />

Page 6<br />

Smart Grid Division<br />

Infrastructure & Cities Sector – Smart Grid Division<br />

© <strong>Siemens</strong> AG 2013. All rights reserved.


<strong>SIPROTEC</strong> 5: Perfect Tailored Fit<br />

Base Module Expansion Modules Up to19'' rack<br />

+ + + +<br />

=<br />

Page 7<br />

Smart Grid Division<br />

Infrastructure & Cities Sector – Smart Grid Division<br />

© <strong>Siemens</strong> AG 2013. All rights reserved.


Mounting of an Expansion Module<br />

Robust and stable<br />

connection between<br />

parts<br />

Page 8<br />

Smart Grid Division<br />

Infrastructure & Cities Sector – Smart Grid Division<br />

© <strong>Siemens</strong> AG 2013. All rights reserved.


<strong>SIPROTEC</strong> 5: Front Panel (HMI)<br />

Base Module<br />

Expansion Module<br />

Description Field<br />

for LEDs<br />

16 LEDs (red)<br />

16 LEDs (green or red,<br />

selectable)<br />

Description Field<br />

for LEDs<br />

Context Sensitive Keys<br />

LED Acknowledge<br />

and Reset of latched<br />

information<br />

Cursor Keys<br />

Numerical Keys<br />

and Function Keys<br />

Key Switch S5<br />

“Remote/Local”<br />

USB plug-in<br />

Description Field<br />

for Function Keys<br />

Control of Switching Elements<br />

Key Switch S1<br />

“Interlocking Off / Normal”<br />

Page 9<br />

Smart Grid Division<br />

Infrastructure & Cities Sector – Smart Grid Division<br />

© <strong>Siemens</strong> AG 2013. All rights reserved.


<strong>SIPROTEC</strong> 5: Designed to Communicate<br />

Ethernet module<br />

Electrical and Optical modules<br />

without / with integrated switch<br />

Up to 8 communication ports<br />

in one device<br />

Universal Serial<br />

Electrical and Optical modules<br />

Electrical Ethernet module<br />

with two electrical ports<br />

Electrical module with<br />

RS485 interface<br />

Optical Ethernet module with<br />

two optical ports<br />

Optical long distance<br />

module with two 1300<br />

or 1550 nm interfaces<br />

* Wave division multiplexer<br />

N<br />

P<br />

E<br />

F<br />

Fiber optical module with<br />

820 nm interface<br />

Page 10<br />

Smart Grid Division<br />

Infrastructure & Cities Sector – Smart Grid Division<br />

© <strong>Siemens</strong> AG 2013. All rights reserved.


<strong>SIPROTEC</strong> 5: Holistic Workflow<br />

With <strong>SIPROTEC</strong> 5, you are almost<br />

finished right at the beginning<br />

Primary and Secondary Equipment<br />

Graphically Linked<br />

• Application templates in DIGSI 5<br />

(i.e., line protection)<br />

• Select the application template, which<br />

defines the complete functional scope<br />

• Customize application as required to<br />

individual requirements<br />

Page 11<br />

Smart Grid Division<br />

Infrastructure & Cities Sector – Smart Grid Division<br />

© <strong>Siemens</strong> AG 2013. All rights reserved.


<strong>SIPROTEC</strong> 5: Innovative Terminal Technology<br />

• Terminal Blocks are Removable (Pre Wire your<br />

Retro Fit Projects)<br />

• CT’s Integrated in the Blocks<br />

• CT’s Auto Short for Safety!<br />

• No Bare Copper or Metallic Surface<br />

Excellent for retrofitting or maintenance<br />

Page 12<br />

Smart Grid Division<br />

Infrastructure & Cities Sector – Smart Grid Division<br />

© <strong>Siemens</strong> AG 2013. All rights reserved.


<strong>SIPROTEC</strong> 5: Security and Safety Inside<br />

Encryption of the communication line between DIGSI 5 and the<br />

<strong>SIPROTEC</strong> 5 relay<br />

Beyond NERC CIP Cyber-security Compliance<br />

Multi-level Cyber-security Chain<br />

Connection password<br />

according to NERC-CIP requirements<br />

Recording of access attempts<br />

t<br />

in a non-volatile safety log<br />

Sophisticated self-monitoring routines locate<br />

and report device disturbances immediately<br />

Safety-critical operations<br />

and accurately<br />

require the input of confirmation codes<br />

Proven functions for the protection of equipment and<br />

users were continually enhanced over 5 generations<br />

Page 13<br />

Smart Grid Division<br />

Infrastructure & Cities Sector – Smart Grid Division<br />

© <strong>Siemens</strong> AG 2013. All rights reserved.


<strong>SIPROTEC</strong> 5: 1 ½ Breaker Application<br />

BB I 230kV<br />

MP U 3p<br />

A_Q0<br />

A_Q9<br />

MP I 3p<br />

MP I3p<br />

7Sx8<br />

7SL87<br />

P1C5036<br />

B_Q0<br />

C_Q9<br />

MP U 1p<br />

MP U 3p<br />

MP U 3p<br />

MP U 1p<br />

MP I 3p<br />

MP I 3p<br />

MP I 3p<br />

6MD8<br />

6MD86<br />

P1G4312<br />

Di<br />

iameter r-Bus<br />

C_Q0<br />

MP U 3p<br />

MP I 3p<br />

7SL87<br />

P1C5036<br />

I/O Unit<br />

for<br />

Additonal Indications<br />

6MD85<br />

(i.e. MCB Trips P1G499 etc.)<br />

MP I 3p<br />

7Sx8<br />

6MD8<br />

BB II 230kV<br />

Page 14<br />

Smart Grid Division<br />

Infrastructure & Cities Sector – Smart Grid Division<br />

© <strong>Siemens</strong> AG 2013. All rights reserved.


<strong>SIPROTEC</strong> Software<br />

SIGRA – The Standard for Fault Analysis<br />

SOE<br />

Annunciation<br />

Measurements<br />

Oscillography<br />

Page 15<br />

Smart Grid Division<br />

Infrastructure & Cities Sector – Smart Grid Division<br />

© <strong>Siemens</strong> AG 2013. All rights reserved.


Wide Area Grid Monitoring – SIGUARD<br />

Page 16<br />

Smart Grid Division<br />

Infrastructure & Cities Sector – Smart Grid Division<br />

© <strong>Siemens</strong> AG 2013. All rights reserved.


Thank you for your attention!<br />

8. Februar<br />

2013<br />

Page 17<br />

Smart Grid Division<br />

Author<br />

Infrastructure & Cities Sector – Smart Grid Division<br />

© <strong>Siemens</strong> © <strong>Siemens</strong> AG 2013. AG 2013. All All rights reserved.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!