Sineax True RMS Multi-Function Electrical Power Meter A 2000<br />

Input: 0-500 VAC Single Phase or 3 Phase<br />

Output: Analog, Pulse, Relay, Datalogging, Digital<br />

Field or PC Programmable<br />

● Accepts 1 A or 5 A CT Ratios<br />

● Datalogging Option for Event Monitoring<br />

● Monitor Harmonic Distortion to Evaluate System Quality<br />

● RS 232 and MODBUS RTU Standard<br />

● PROFIBUS DP or LONWORKS Optional<br />

● Easy Setup and Operation<br />

● Settings and Readings Can be Locked to Prevent Tampering<br />

Applications<br />

■ Electrical Power Quality Recording<br />

■ Power Consumption Monitoring<br />

■ Power Efficiency Monitoring<br />

Specifications<br />

Input<br />

Single phase or 3 phase 3-wire balanced, 4-wire balanced or unbal.<br />

Phase to phase: 0 to 500 VAC max.<br />

Phase to neutral: 0 to 290 VAC max.<br />

Frequency: 40 to 70 Hz<br />

Current:<br />

0-1 A to 0-6 A<br />

Sampling rate: Adjustable, 300 ms to 30 min.<br />

Digital internal or external input for synchronization or tariff change<br />

Adjustable CT & VT ratios for current & voltage inputs<br />

Measurements<br />

True RMS measurements for distorted waveforms<br />

Voltage: U1, U2, U3, U12, U23, U31, max values<br />

Current: I1, I2, I3, avg, max, avgmax values, Neutral current<br />

Frequency: 40 to 70 Hz<br />

Power Factor Cosϕ: PF1, PF2, PF3, min values, PFΣ, PFΣmin<br />

Active Power (Watt): P1, P2, P3, max values, PΣ, PΣmax<br />

Reactive Power (VAR): Q1, Q2, Q3, max values, QΣ, QΣmax<br />

Apparent Power (VA): S1, S2, S3, max values, SΣ, SΣmax<br />

Active & Reactive Energy (Wh, VARh): all 4 quadrants<br />

THD 1st-15th Harmonic, Voltage: U1, U2, U3<br />

THD 1st-15th Harmonic, Current: I1, I2, I3<br />

Outputs, Datalogging & Communications<br />

2 or 4 isolated analog outputs<br />

Digital pulse outputs for active & reactive energy<br />

2 relay outputs with limit setpoints<br />

RS232/485 interface, MODBUS-RTU standard<br />

Data logging version: Up to 12 variables – 63,000 values<br />

Recording duration: 1 minute to 4 days or continuous<br />

Optional LONWORKS or PROFIBUS-DP interface versions<br />

Accuracy<br />

U and I, true RMS measurement: ±0.25%<br />

Power: ±0.5% for<br />

Frequency: ±0.02%<br />

Display<br />

Four 4-digit red LED displays, 14 mm H<br />

Alphanumeric displays for units<br />

Protection<br />

IP 65 front panel<br />

Dimensions<br />

Full DIN<br />

144 mm W x 144 mm H x 60 mm D<br />

138 mm W x 138 mm H panel cutout<br />

C<br />

US<br />

ISO 9001 : 2000<br />

Models & Options<br />

A2000-H0-A0-P1-R0-L0-U0-W1 2 analog & 2 pulse outputs, MODBUS,<br />

115/230 VAC powered<br />

A2000-H0-A0-P1-R1-L0-U0-W1 2 analog & 2 pulse outputs, data logging,<br />

MODBUS, 115/230 VAC powered<br />

A2000-H0-A1-P1-R0-L0-U0-W1 4 analog & 2 pulse outputs, MODBUS,<br />

115/230 VAC powered<br />

A2000-H0-A1-P1-R1-L0-U0-W1 4 analog & 2 pulse outputs, data logging,<br />

MODBUS, 115/230 VAC powered<br />

Optional Versions<br />

Please contact factory for DC powered, LONWORKS interface, PROFIBUS-<br />

DP interface<br />

AC Power<br />

API maintains a constant effort to upgrade and improve its products. Specifications<br />

are subject to change without notice. Consult factory for your specific requirements.<br />

© 01-07<br />

1220 American Way Libertyville, IL 60048<br />

BSOLUTE ROCESS NSTRUMENTS, <strong>Inc</strong>. Phone: 800-942-0315 Fax: 800-949-7502 api-usa.com 43