G<strong>EN</strong>ERATING SET TECHNICAL GUIDE <strong>GSA7</strong>-<strong>10</strong> <strong>Open</strong> <strong>set</strong><br />

MODEL|<strong>GSA7</strong>-<strong>10</strong><br />

REF. GDS <strong>05</strong>.00<br />

LOMBARDINI Diesel engine.<br />

Air cooling system.<br />

Industrial muffler.<br />

Complete with engine and battery liquids.<br />

TECHNICAL FEATURES<br />

MANUAL CONTROL PANEL (MCP)<br />

MODEL GSA 7 GSA<strong>10</strong><br />

CODE SG060TLA SG<strong>10</strong>0TLA<br />

PRIME POWER PRP kVA (kW) 6,1 (4,9) <strong>10</strong>,1 (8,1)<br />

EMERG<strong>EN</strong>CY POWER LTP<br />

Frequency Hz 50 50<br />

Power factor Cos φ 0,8 0,8<br />

Fuel capacity Litres 7 <strong>10</strong><br />

Autonomy ( <strong>10</strong>0% load PRP) h 3,3 3,1<br />

Dimensions (LxWxH) mm 920x650x1.0<strong>10</strong> 1.440x660x1.015<br />

Weight kg 232 244<br />

DIESEL <strong>EN</strong>GINE <strong>Lombardini</strong> 4LD 820/L 9LD 625/2<br />

Cooling system Type Air Air<br />

Speed rpm 1.500 1.500<br />

Displacement c.c. 817 1.248<br />

Cyliders and disposition n° disp. 1 L 2 L<br />

Aspiration Tipo Natural Natural<br />

Engine power PRP kWm 6 <strong>10</strong><br />

Fuel consumption (<strong>10</strong>0% load) l/h 2,1 3,2<br />

Specific consumption PRP g/kWh ND ND<br />

Engine governor (standard) Type Mechanical Mechanical<br />

SYNCHRONOUS ALTERNATOR LINZ E1S 13S/4 - 7,5kVA E1S 13S/4 - 11kVA<br />

Insulation Class H H<br />

Mechanical degree of protection Type IP23 IP23<br />

Voltage regulation Type Compound<br />

MANUAL CONTROL PANEL (MCP) GSA 7 GSA<strong>10</strong><br />

Manual control panel, mounted on<br />

the gen<strong>set</strong> and complete of:<br />

instrumentation, protection and<br />

sockets.<br />

kVA (kW)<br />

Instrumentation<br />

(analogue)<br />

Commands and<br />

others<br />

Protections<br />

Output sockets<br />

• Voltmeter.<br />

• Frequency meter.<br />

• Ammeter.<br />

• Hours-counter.<br />

• Start and stop selector switch with key.<br />

• Emergency stop button.<br />

6,8 (5,4) 11,3 (9,0)<br />

Voltage Volt 400/230 400/230<br />

• Engine protection: low oil pressure, battery charger failure.<br />

• Circuit breaker protection: IV poles.<br />

• Differential protection.<br />

1 x 3P+N+T 400V/16A CEE socket.<br />

1 x 2P+T 230V/16A CEE socket.<br />

1 x Schuko 230V/16A socket.<br />

Compound<br />

TECHNICAL CHARACTERISTICS NOT IMPEGNATIVE RESERVATION OF MODIFICATIONS FOR INNOVATION OF THE PRODUCT<br />

<strong>Rev.00</strong> Pag. 1 of 2


G<strong>EN</strong>ERATING SET TECHNICAL GUIDE <strong>GSA7</strong>-<strong>10</strong> <strong>Open</strong> <strong>set</strong><br />

AUTOMATIC CONTROL PANEL (ACP)<br />

GSA 7<br />

GSA<strong>10</strong><br />

AUTOMATIC CONTROL PANEL (ACP)<br />

Automatic control panel mounted<br />

on the gen<strong>set</strong>, complete with<br />

digital control unit AC02 for<br />

monitoring, control and protection<br />

of the generating <strong>set</strong>.<br />

• Generating <strong>set</strong> voltage.<br />

Digital • Generating <strong>set</strong> frequency.<br />

instrumentation • Generator <strong>set</strong> current.<br />

through AC02 control • Battery voltage.<br />

unit. • Hours-counter.<br />

• Mains voltage.<br />

Commands and<br />

others<br />

Protections with<br />

alarm<br />

Protections with<br />

shutdown<br />

• Selector switch with six positions: Automatic test - Automatic starting - Engine locked - Mains contactor<br />

forced - Manual starting - Gen<strong>set</strong> contactor forced.<br />

• Push-buttons: start/stop, up/down selection, re<strong>set</strong>.<br />

• Emergency stop button.<br />

• Remote starting availability.<br />

• Automatic battery charger.<br />

• Engine protection: low oil pressure.<br />

• Gen<strong>set</strong> protection: under/over voltage, overload, battery charger failure, battery voltage out of limits,<br />

under/over frequency, start failure.<br />

• Engine protection: low oil pressure.<br />

• Gen<strong>set</strong> protection: under/over voltage, overload, battery charger failure, battery voltage out of limits,<br />

under/over frequency, start failure.<br />

• Circuit breaker protection: IV poles.<br />

• Differential protection.<br />

TECHNICAL CHARACTERISTICS NOT IMPEGNATIVE RESERVATION OF MODIFICATIONS FOR INNOVATION OF THE PRODUCT<br />

AUTOMATIC CONTROL PANEL (AMF)<br />

Automatic control panel for<br />

automatic starting by Mains<br />

failure. Delivered loose from the<br />

gen<strong>set</strong>, and complete with digital<br />

control unit AC02 for monitoring,<br />

control and protection of the<br />

generating <strong>set</strong>.<br />

Output<br />

AUTOMATIC CONTROL PANEL (AMF)<br />

• Generating <strong>set</strong> voltage.<br />

Digital • Generating <strong>set</strong> frequency.<br />

instrumentation • Generator <strong>set</strong> current.<br />

through AC02 control • Battery voltage.<br />

unit. • Hours-counter.<br />

• Mains voltage.<br />

Commands and<br />

others<br />

Change over<br />

contactors<br />

Mains/Gen<strong>set</strong><br />

Protections with<br />

alarm<br />

Protections with<br />

shutdown<br />

Output<br />

ACCESSORIES<br />

LOAD TRANSFER SWITCH PANEL.<br />

• Plinth row for connection from ACP to LTS panel.<br />

• Power cables connection directly from circuit breaker.<br />

<strong>GSA7</strong><br />

• Selector switch with six positions: Automatic test - Automatic starting - Engine locked - Mains contactor<br />

forced - Manual starting - Gen<strong>set</strong> contactor forced.<br />

• Push-buttons: start/stop, up/down selection, re<strong>set</strong>.<br />

• Emergency stop button.<br />

• Remote starting availability.<br />

• Automatic battery charger.<br />

IV poles - 20A.<br />

IV poles - 20A.<br />

• Engine protection: low oil pressure.<br />

• Gen<strong>set</strong> protection: under/over voltage, overload, battery charger failure, battery voltage out of limits,<br />

under/over frequency, start failure.<br />

• Engine protection: low oil pressure.<br />

• Gen<strong>set</strong> protection: under/over voltage, overload, battery charger failure, battery voltage out of limits,<br />

under/over frequency, start failure.<br />

<strong>GSA7</strong><br />

GSA<strong>10</strong><br />

• Plinth row for connection from pre-wired panel (mounted on the gen<strong>set</strong>) to AMF panel.<br />

• Power cables connected to terminals board (internal).<br />

GSA<strong>10</strong><br />

Change over<br />

contactors<br />

IV poles - 20A. IV poles - 20A.<br />

ACCESSORIES<br />

Load transfer switch panel built in<br />

a metal cabinet and supplied loose<br />

from the gen<strong>set</strong>.<br />

Connections<br />

Protections<br />

• Plinth row for connection from ACP to LTS panel.<br />

• Terminals board for power cables connection (Gen<strong>set</strong>-Mains-Load).<br />

• Contactors mechanically and electrically interlocked.<br />

• Emergency stop button.<br />

Automatic control panel + LTS panel measures the Mains voltage and starts automatically the gen<strong>set</strong> within few seconds in case of<br />

Mains failure. It transfers immediately the load again to the gen<strong>set</strong> when the Mains voltage returns within the rated values.<br />