<strong>Sealed</strong> <strong>Boron</strong>-<strong>Coated</strong> <strong>Straws</strong> <strong>for</strong> <strong>Neutron</strong> <strong>Imaging</strong>


<strong>Proportional</strong> Technologies, Inc.’s <strong>Boron</strong>-<strong>Coated</strong> Straw (BCS)<br />

detectors are now offered in a sealed package, operable in<br />

vacuum environments, readily scalable to replace positionsensitive<br />

3 He tubes in neutron science instruments.<br />

Features<br />

& Benefits<br />

Stability<br />

<strong>Sealed</strong>-mode<br />

operation offers<br />

reliable per<strong>for</strong>mance<br />

Scalability<br />

Standard lengths up<br />

to 3 m, can be closepacked<br />

to <strong>for</strong>m large<br />

panels<br />

Maturity<br />

BCS detectors are<br />

currently employed in<br />

a host of applications,<br />

including portal<br />

monitors, fission<br />

counters, handhelds,<br />

etc.<br />

Low Cost<br />

Automated<br />

fabrication - low cost<br />

materials<br />

Detection efficiency<br />

Comparable to 3 He<br />

tubes through use of<br />

multiple individually<br />

decoded layers<br />

Gamma<br />

discrimination<br />

Gamma Rejection 10 -7<br />

– 10 -10<br />

Fast<br />

Supports up to 40<br />

fold higher Bragg<br />

peak rates without<br />

saturation<br />

<strong>Boron</strong>-coated straws are 7.5<br />

mm in diameter and coated<br />

on the inside with a pure,<br />

micron-thick layer of 10 B-<br />

enriched boron carbide<br />

( 10 B 4 C). Their unique design<br />

eliminates the efficiency<br />

deficit of traditional boronlined<br />

counters, offering a<br />

drop-in replacement to 3 He<br />

tubes.<br />

BCS detectors are now<br />

offered in a package that<br />

groups 7 inside a single<br />

sealed aluminum tube.<br />

The tube is 25.4 mm (1”) in<br />

diameter, with an active<br />

length up to 3 m, and allows<br />

operation in vacuum<br />

environments <strong>for</strong> indefinite<br />

periods of time.<br />

We are pleased to offer<br />

demonstration units <strong>for</strong><br />

evaluation in single tube or 7<br />

tube (49 straw) packs in<br />

lengths up to 2 meters.


Detection efficiency<br />

<strong>Sealed</strong> <strong>Boron</strong>-<strong>Coated</strong> <strong>Straws</strong> <strong>for</strong> <strong>Neutron</strong> <strong>Imaging</strong><br />

80<br />

1.0 mm thick coating<br />

70<br />

60<br />

50<br />

40<br />

30<br />

10 Angstrom<br />

5<br />

2.5<br />

1.8<br />

1.3<br />

20<br />

10<br />

0<br />

1 2 3 4 5 6 7 8 9 10<br />

Number of bundle layers<br />

Specifications:<br />

• Materials:<br />

o Gas Containment Tube: 6061 T6 Aluminum<br />

o <strong>Straws</strong> (7×): Highly durable PVD-coated 1-µm-thick 10 B 4 C-coated (>95%<br />

enriched) high purity copper or aluminum foil<br />

o Anode Wire: 20 µm diameter resistive wire, 4.3 kΩ/m<br />

• Gas containment tube:<br />

o Dimensions: 25.4 mm diameter (D t ) × 0.88 mm wall thickness (W t ), up to 3 m<br />

active length (0.50 mm wall by special order)<br />

o Effective aluminum depth per tube = πW t = 2.8 mm <strong>for</strong> W t =0.88 mm (1.6 mm <strong>for</strong><br />

W t =0.50 mm)<br />

• <strong>Straws</strong> (7x):<br />

o Dimensions: 7.5 mm (D s ) × 0.05 mm wall thickness (W s ), up to 3 m active length<br />

o Effective aluminum depth per 7-straw tube = 7πD s W s /D t = 0.33 mm<br />

• Weight (single 7 straw tube, 2 m long): 543 g (1.20 lbs)<br />

• Fill gas: Argon-CO 2, pressure 0.7 atm<br />

• Operating voltage: 1000 Volts<br />

• Spatial resolution (by charge division): FWHM < 1% of length over full detector length<br />

e.g. 1.5 meter detector < 15 mm, resolution voxel 7.5 × 7.5 ×


8022 El Rio Street<br />

Houston, TX 77054<br />

Tel: +1 (713) 747-7324<br />

Fax: +1 (713) 747-7325<br />

E-mail: sales@proportionaltech.com<br />

Web: http://www.proportionaltech.com