Divinycell International, Inc.<br />

MATERIAL SAFETY DATA SHRET<br />

SECTION 1<br />

PRODUCT IDENTIFICATION<br />

Product Name:<br />

<strong>DIVINYCELL</strong> “H” <strong>Grade</strong> <strong>Foam</strong><br />

H30, H45, H60, H80, H100, H130<br />

Manufacturer’s Name:<br />

Divinycell International, Inc.<br />

315 Seahawk Drive<br />

DeSoto, Texas 75115<br />

Emergency Telephone# (800) 852-4835<br />

Information Telephone # (214) 228-7600<br />

Last Revision Date: 1/7/94 Rev. C<br />

This product is manufactured without CFC’s or any other products which act in<br />

an ozone depletion manner.<br />

SECTION II<br />

Components<br />

Not Applicable<br />

SECTION III<br />

HAZARDOUS INGREDIENTS/IDENTITY INFORMATION<br />

PHYSICAL AND CHEMICAL CHARACTERISTICS<br />

Boiling Point<br />

Vapor Pressure (mm Hg)<br />

Vapor Density (Air-i)<br />

Solubility in Water<br />

Appearance and Odor<br />

Specific Gravity (H20 -1)<br />

Melting Point<br />

Evaporation Race<br />

SECTION IV<br />

N/A<br />

N/A<br />

N/A<br />

N/A<br />

<strong>Foam</strong> slabs or sheets/no odor<br />

N/A<br />

N/A<br />

N/A<br />

FIRE AND EXPLOSION HAZARD DATA<br />

Flash Point (Method Used)<br />

Flammable Limits<br />

Extinguishing Media<br />

Special Fire Fighting Procedures<br />

Unusual Fire and Explosion Hazards<br />

Oxygen Index less than 3096 (ASTM D2863) Self<br />

Extinguishing (ASTM 1692)<br />

Direct flame only<br />

Water, Dry Chemical<br />

None<br />

None<br />

1


SECTION V<br />

stability<br />

incompatibility<br />

Hazardous decomposition<br />

or by-product<br />

REACTIVITY DATA<br />

Can be used at temperatures 1700- 1800°F.<br />

thermally stable at 2100 F.<br />

Avoid exposure to temperatures above 300°F.<br />

HC1, CO, CO2, HCN, NOx during fire conditions<br />

Hazardous Polymerization<br />

conditions to avoid Will not occur N/A<br />

SECTION VI<br />

Route of entry<br />

HEALTH HAZARD DATA<br />

Inhalation<br />

Acute and Chronic<br />

Hazards<br />

Carcinogenicity<br />

Signs and symptoms of<br />

Exposure<br />

Traces of HC1 during machining. Avoid inhalation of dust or smoke.<br />

N/A<br />

Shortness of breath, dizziness<br />

Medical conditions generally<br />

aggravated by exposure Pneumonistis<br />

Emergency/First Aid<br />

SECTION VII<br />

Spills<br />

Waste Disposal<br />

Precautions for handling<br />

and storing<br />

Remove to fresh air-consult physician if shortness of breath<br />

continues.<br />

PRECAUTION FOR SAFE HANDLING AND USE<br />

None<br />

Landfill - consult local regulations<br />

Avoid storing in areas where temperature may exceed 280° degrees<br />

Fahrenheit.<br />

Other precautions<br />

Abrasive dust may irritate skin<br />

2


SECTION VIII<br />

CONTROL MEASURES<br />

Respiratory Protection<br />

Ventilation<br />

Protective gloves<br />

Eye protection<br />

Other Protective Clothing<br />

or equipment<br />

Work/Hygienic Practices<br />

Dust mask during machining, sawing and sanding<br />

Local exhaust - fans or vacuum<br />

None<br />

Dust protection<br />

None<br />

None<br />

Divinycell International, Inc.<br />

<strong>DIVINYCELL</strong> H SERIES FOAM<br />

THE INFORMATION CONTAINED HEREIN IS BASED ON DATA CONSIDERED TO BE<br />

ACCURATE WHILE THE INFORMATION IS BELIEVED TO BE RELIABLE NO<br />

WARRANTY IS EXPRESSED OR IMPLIED REGARDING THE ACCURACY OF THIS<br />

DATA OR THE RESULTS TO BE OBTAINED FROM THE USE THEREOF. SINCE THE<br />

USE OF THIS INFORMATION AND THE CONDITIONS AND USE OF THIS PRODUCT<br />

ARE CONTROLLED BY THE USER, IT IS THE USER’S OBLIGATION TO DETERMINE<br />

THE CONDITIONS FOR SAFE USE OF THIS PRODUCT.<br />

Material Safety Data Sheet may be used to comply with OSHA’s Hazard Communication<br />

Standard, 29 CFR 1910.1200. Standard must be consulted for specific requirements<br />

3