DIVINYCELL H Grade Foam - Fiberglass Supply
DIVINYCELL H Grade Foam - Fiberglass Supply
DIVINYCELL H Grade Foam - Fiberglass Supply
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Divinycell International, Inc.<br />
MATERIAL SAFETY DATA SHRET<br />
SECTION 1<br />
PRODUCT IDENTIFICATION<br />
Product Name:<br />
<strong>DIVINYCELL</strong> “H” <strong>Grade</strong> <strong>Foam</strong><br />
H30, H45, H60, H80, H100, H130<br />
Manufacturer’s Name:<br />
Divinycell International, Inc.<br />
315 Seahawk Drive<br />
DeSoto, Texas 75115<br />
Emergency Telephone# (800) 852-4835<br />
Information Telephone # (214) 228-7600<br />
Last Revision Date: 1/7/94 Rev. C<br />
This product is manufactured without CFC’s or any other products which act in<br />
an ozone depletion manner.<br />
SECTION II<br />
Components<br />
Not Applicable<br />
SECTION III<br />
HAZARDOUS INGREDIENTS/IDENTITY INFORMATION<br />
PHYSICAL AND CHEMICAL CHARACTERISTICS<br />
Boiling Point<br />
Vapor Pressure (mm Hg)<br />
Vapor Density (Air-i)<br />
Solubility in Water<br />
Appearance and Odor<br />
Specific Gravity (H20 -1)<br />
Melting Point<br />
Evaporation Race<br />
SECTION IV<br />
N/A<br />
N/A<br />
N/A<br />
N/A<br />
<strong>Foam</strong> slabs or sheets/no odor<br />
N/A<br />
N/A<br />
N/A<br />
FIRE AND EXPLOSION HAZARD DATA<br />
Flash Point (Method Used)<br />
Flammable Limits<br />
Extinguishing Media<br />
Special Fire Fighting Procedures<br />
Unusual Fire and Explosion Hazards<br />
Oxygen Index less than 3096 (ASTM D2863) Self<br />
Extinguishing (ASTM 1692)<br />
Direct flame only<br />
Water, Dry Chemical<br />
None<br />
None<br />
1
SECTION V<br />
stability<br />
incompatibility<br />
Hazardous decomposition<br />
or by-product<br />
REACTIVITY DATA<br />
Can be used at temperatures 1700- 1800°F.<br />
thermally stable at 2100 F.<br />
Avoid exposure to temperatures above 300°F.<br />
HC1, CO, CO2, HCN, NOx during fire conditions<br />
Hazardous Polymerization<br />
conditions to avoid Will not occur N/A<br />
SECTION VI<br />
Route of entry<br />
HEALTH HAZARD DATA<br />
Inhalation<br />
Acute and Chronic<br />
Hazards<br />
Carcinogenicity<br />
Signs and symptoms of<br />
Exposure<br />
Traces of HC1 during machining. Avoid inhalation of dust or smoke.<br />
N/A<br />
Shortness of breath, dizziness<br />
Medical conditions generally<br />
aggravated by exposure Pneumonistis<br />
Emergency/First Aid<br />
SECTION VII<br />
Spills<br />
Waste Disposal<br />
Precautions for handling<br />
and storing<br />
Remove to fresh air-consult physician if shortness of breath<br />
continues.<br />
PRECAUTION FOR SAFE HANDLING AND USE<br />
None<br />
Landfill - consult local regulations<br />
Avoid storing in areas where temperature may exceed 280° degrees<br />
Fahrenheit.<br />
Other precautions<br />
Abrasive dust may irritate skin<br />
2
SECTION VIII<br />
CONTROL MEASURES<br />
Respiratory Protection<br />
Ventilation<br />
Protective gloves<br />
Eye protection<br />
Other Protective Clothing<br />
or equipment<br />
Work/Hygienic Practices<br />
Dust mask during machining, sawing and sanding<br />
Local exhaust - fans or vacuum<br />
None<br />
Dust protection<br />
None<br />
None<br />
Divinycell International, Inc.<br />
<strong>DIVINYCELL</strong> H SERIES FOAM<br />
THE INFORMATION CONTAINED HEREIN IS BASED ON DATA CONSIDERED TO BE<br />
ACCURATE WHILE THE INFORMATION IS BELIEVED TO BE RELIABLE NO<br />
WARRANTY IS EXPRESSED OR IMPLIED REGARDING THE ACCURACY OF THIS<br />
DATA OR THE RESULTS TO BE OBTAINED FROM THE USE THEREOF. SINCE THE<br />
USE OF THIS INFORMATION AND THE CONDITIONS AND USE OF THIS PRODUCT<br />
ARE CONTROLLED BY THE USER, IT IS THE USER’S OBLIGATION TO DETERMINE<br />
THE CONDITIONS FOR SAFE USE OF THIS PRODUCT.<br />
Material Safety Data Sheet may be used to comply with OSHA’s Hazard Communication<br />
Standard, 29 CFR 1910.1200. Standard must be consulted for specific requirements<br />
3