Vacuum analysis<br />

and measurement<br />

Measurement and control units ActiveLine<br />

ActiveLine Active Pirani transmitters TPR 281,<br />

(5·10 -4 - <strong>1000</strong> <strong>mbar</strong>), for corrosive media<br />

ActiveLine<br />

Measurement range from<br />

5·10 -4 to <strong>1000</strong> bar<br />

Compact and rugged<br />

Fast, stable measurement<br />

For corrosive media<br />

Maximum pressure refers to inert gases<br />

Dimensions<br />

16<br />

(0.63")<br />

20.5<br />

(0.81")<br />

16<br />

(0.63")<br />

20.5<br />

(0.81")<br />

69<br />

(2.72")<br />

22.5<br />

(0.89")<br />

69<br />

(2.72")<br />

33<br />

(1.30")<br />

15<br />

(0.58")<br />

14<br />

(0.55")<br />

33<br />

(1.30")<br />

DN 16 ISO-KF DN 16 CF-R<br />

116<br />

(4.57")<br />

115<br />

(4.53")<br />

DN 16 ISO-KF DN 16 CF-R<br />

Active Pirani transmitter TPR 281, 65 ºC Active Pirani Transmitter TPR 281, 250 ºC<br />

Page Page 496 496<br />

www.pfeiffer-vacuum.net


Technical data<br />

Active Pirani<br />

transmitter<br />

TPR 281, 65 ºC<br />

Active Pirani<br />

Transmitter<br />

TPR 281, 250 ºC<br />

Output signal: Sensor error below 0.5 V 0.5 V<br />

Output signal: Pressure range 2.2-8.5 V 2.2-8.5 V<br />

Output signal: Minimum load 10 kOhm 10 kOhm<br />

Bakeout temperature 80 °C 250 °C<br />

Seal Metal Metal<br />

Pressure max. 10 bar 10 bar<br />

Feedthrough Glass Glass<br />

Feature<br />

for corrosive<br />

media<br />

for corrosive<br />

media<br />

Flange Stainless steel Stainless steel<br />

Accuracy: 10 -3 - 10 2 <strong>mbar</strong> +/- 15 % +/- 15 %<br />

Filament Nickel Nickel<br />

Measurement range max. <strong>1000</strong> <strong>mbar</strong> <strong>1000</strong> <strong>mbar</strong><br />

Measurement range min. 5·10 -4 <strong>mbar</strong> 5·10 -4 <strong>mbar</strong><br />

Sensor cable length max. 200 m 200 m<br />

Temperature: Operating +5 - +60 ºC +5 - +60 ºC<br />

Temperature: Storage -20 - +65 ºC -20 - +65 ºC<br />

Supply: Voltage 14-30 V DC 14-30 V DC<br />

Supply: Power consumption max. 1 W 1 W<br />

Repeatability: 10 -3 - 10 2 <strong>mbar</strong> +/- 2 % +/- 2 %<br />

Active Pirani<br />

transmitter<br />

TPR 281, 65 ºC<br />

Active Pirani<br />

Transmitter<br />

TPR 281, 250 ºC<br />

Flange (in) DN 16 ISO-KF DN 16 ISO-KF<br />

Weight 80 g 130 g<br />

Volume 1.3 cm 3 10 cm 3<br />

Order number PT R21 950 PT R21 960<br />

Flange (in) DN 16 CF-R DN 16 CF-R<br />

Weight 100 g 140 g<br />

Volume 1.5 cm 3 10 cm 3<br />

Order number PT R21 951 PT R21 961<br />

Mess- und<br />

Steuergeräte<br />

Measurement<br />

controll units<br />

Accessories<br />

Centering ring with poral filter, FPM/stainless steel, PF 117 216-T<br />

DN 16 ISO-KF<br />

Fine filter for TPR 265, pore size 0.0004 mm PT 120 132-T<br />

Mating connector for compact gauge B 4707 283 MA B 4707 283 MA<br />

Sensor cable, 3 m PT 448 250-T PT 448 250-T<br />