TABLE I<br />

Test Module Microza XUSV-5203<br />

Outside Membrane Area 398 ft 2<br />

Module Length<br />

2 meters<br />

Module Diameter<br />

5 inches<br />

Membrane Material<br />

PVDF<br />

Housing Material<br />

PVC<br />

<strong>The</strong> Microza hollow-fiber membrane was operated in an outside-to-inside mode with periodic<br />

regeneration of the membrane by a simultaneous air scrubbing/reverse flow (SASRF) followed by a<br />

reverse flow (RF). <strong>The</strong> excess recirculation (XR) rate for this pilot study was 10% of filtrate. <strong>The</strong> pilot<br />

system operates at a constant filtrate flow rate. <strong>The</strong> operating conditions are shown in Table II.<br />

TABLE II<br />

Summary of Operating Conditions<br />

Filtrate<br />

Flux Based on Outside Area<br />

Recirculation Rate<br />

SASRF (frequency, duration, flowrate)<br />

Cycle 1 (3/30 to 4/5)<br />

(4/5 to 5/3)<br />

Cycle 2 (5/4 to 5/17)<br />

(5/18 to 5/21)<br />

Cycle 3 (5/22 to 5/30)<br />

(6/1 to 6/8)<br />

Cycle 4 (6/8 to 6/17)<br />

(6/19 to 7/9)<br />

RF (frequency, duration, flowrate)<br />

Cycle 1 (3/30 to 4/5)<br />

(4/5 to 5/3)<br />

Cycle 2 (5/4 to 5/17)<br />

(5/18 to 5/21)<br />

Cycle 3 (5/22 to 5/30)<br />

(6/1 to 6/8)<br />

Cycle 4 (6/8 to 6/17)<br />

(6/19 to 7/11)<br />

7.7 to 12 GPM<br />

27.9 to 43.4 GFD<br />

10% of filtrate<br />

30 min, (30 sec air/60 sec air + filtrate), 5 gpm<br />

30 min, (0 sec air/90 sec air + filtrate), 5 gpm<br />

30 min, (0 sec air/70 sec air + filtrate), 5 gpm<br />

30 min, (30 sec air/60 sec air + filtrate), 5 gpm<br />

30 min, (30 sec air/60 sec air + filtrate), 5 gpm<br />

30 min, (30 sec air/60 sec air + filtrate), 5 gpm<br />

30 min, (30 sec air/60 sec air + filtrate), 5 gpm<br />

30 min, (30 sec air/60 sec air + filtrate), 5 gpm<br />

30 min, 20 sec, 10 gpm<br />

30 min, 20 sec, 10 gpm<br />

30 min, 20 sec, 10 gpm<br />

30 min, 20 sec, 15 gpm<br />

30 min, 20 sec, 14 gpm<br />

30 min, 20 sec, 12 gpm<br />

30 min, 20 sec, 12 gpm<br />

30 min, 20 sec, 13 gpm<br />

This report is proprietary to PALL CORPORATION and is furnished in Confidence for the Private use of the intended recipient, for the sole purpose of evaluating PALL<br />

technology. It may not be copied nor disclosed, in whole or in part, without the prior express approval of PALL CORPORATION.