<strong>PRODUCTINFORMATIE</strong><br />

Nieuwe dimmer voor LED, CFL en Halogeen lampen<br />

Ons assortiment dimmers wordt uitgebreid met een universele dimmer voor LED,<br />

Spaar- en Halogeen lampen, de BTF418. Deze zal vanaf januari 2013 leverbaar zijn.<br />

Artikelnummer: BTF418<br />

Brutoprijs: € 155,-<br />

Kortingsgroep: J5<br />

Details:<br />

n Behuizing 4 modules DIN<br />

n Nul-aansluiting noodzakelijk<br />

n Opgenomen vermogen uit bus, maximaal 10mA<br />

NIEUWE<br />

LED-DIMMER<br />

REF.NR. BTF418<br />

Datum: 27-11-2012<br />

Gebruik: In- en extern<br />

Dimbare belastingen:<br />

* 300VA staat bij LED- en spaarlampen ongeveer gelijk aan 200W<br />

Niet alle te leveren lampen zijn getest i.c.m. deze dimmer. Mede door de verschillende<br />

kwaliteiten van de lampen, is het niet mogelijk om op voorhand een goede werking<br />

van alle combinaties te garanderen.<br />

Meer informatie<br />

Voor prijzen en technische specificaties kunt u de Legrand E-Catalogus bekijken<br />

via www.legrandservices.nl. Voor overige vragen kunt u contact opnemen met<br />

onze afdeling Klantenservice via telefoonnummer 0411 65 33 02<br />

of e-mail salessupport@legrandnederland.nl.<br />

Bijlage: Technical Sheet BTF418<br />

1


Dimmer for LED, CFL,<br />

and halogen lamps<br />

F418<br />

1. USE<br />

1<br />

The device is a dimmer for the management of dimmer LEDs, compact<br />

fluorescent lamps (CFL), and energy saving halogen lamps. After<br />

connecting the dimmer to the BUS and the load, it is possible to adjust<br />

the intensity of the light from any appropriately configured control point.<br />

A quick pressure of the local control pushbutton is enough to switch the<br />

load on or off, while an extended pressure will adjust the light intensity.<br />

The dimmer can be used to adjust the load to 100 different light intensity<br />

levels. It is also possible to adjust the ON time, and the minimum level of<br />

the power in dimmer mode.<br />

6<br />

2. Technical data<br />

Power supply from BUS SCS:<br />

27 Vdc<br />

Operating power supply with SCS BUS: 18 – 27 Vdc<br />

Max. absorption:<br />

10 mA<br />

Number of outputs:<br />

1x 0.9 A<br />

Operating temperature: (-5) – (+35) °C<br />

Dissipated power with max. load:<br />

2.5 W (230 Vac)<br />

1.9 W (127 Vac)<br />

Power/Absorption of driven loads:<br />

Dimmer LEDs, compact<br />

fluorescent lamps, and<br />

energy saving lamps<br />

5<br />

4<br />

3<br />

2<br />

230 Vac 200 W<br />

110 – 127 Vac 100 W<br />

3. Standards, Certifications, Marks<br />

• EN 60669-2-1: Switches for household and similar fixed electrical<br />

installations;<br />

• EN 50090-2-2: Home and building electronic systems (HBES);<br />

• EN 50090-2-3: Home and building electronic systems (HBES), general<br />

functional safety;<br />

• EN 50428: Switches for household and similar fixed electrical<br />

installations.<br />

5. Legend<br />

1. Load<br />

2. Configurator socket (only use in My Home system with physical<br />

configuration)<br />

3. BUS<br />

4. ON/OFF key and brightness adjustment<br />

5. Led<br />

• OFF: BUS not present<br />

• ON green: load off<br />

• ON orange: load on<br />

• flashing quickly orange/green: device not configured<br />

• flashing slowly orange/green: device being configured, or load<br />

fault<br />

6. Fuse<br />

4. Dimensional data<br />

Size: 4 DIN modules<br />

BT00594-a- EN 18/06/2012<br />

1/2


F881NA/16<br />

Dimmer for LED, CFL, and halogen lamps<br />

F418<br />

6. ConfiguraTion<br />

When installed in a MY HOME system, the device may be configured in<br />

two ways:<br />

• PHYSICAL CONFIGURATION, by connecting the physical configurators<br />

to their sockets.<br />

• VIRTUAL CONFIGURATION, by connecting the system to the PC using<br />

the Kit or the Web server. The Virtual configurator software must be<br />

installed on the PC.<br />

PHYSICAL CONFIGURATION<br />

The actuator performs all the basic operating modes that can be<br />

configured directly on the control. Moreover further operating modes<br />

with the configurator in position M of the same actuator are listed in the<br />

table below.<br />

Possible function<br />

Configurator in M<br />

Actuator as Slave. Receives a control sent by<br />

SLA<br />

a Master actuator with the same address<br />

Pushbutton (ON monostable) ignores Room<br />

PUL<br />

and General controls<br />

Master Actuator with OFF control delayed<br />

on the corresponding Slave actuator. Only<br />

for point-point control. With the OFF control<br />

1 – 4<br />

the Master actuator deactivates; the Slave<br />

1)<br />

actuator deactivates after the time set with<br />

the configurators has elapsed 1)<br />

1) The ON control activates the Master actuator and the Slave actuator at<br />

the same time. The next OFF control deactivates the Master actuator<br />

and keeps the Slave actuator active for the period of time set with<br />

configurator 1 - 4 connected to M of the Master actuator as indicated<br />

in the table.<br />

Configurator<br />

Time<br />

1 1<br />

2 2<br />

3 3<br />

4 4<br />

MIN<br />

The configurator in this position defines the minimum value of the light<br />

intensity that can be obtained through dimmer adjustment.<br />

Configurator<br />

Minimum light intensity level<br />

None or 0 Default value (*)<br />

1 1 %<br />

2 5 %<br />

3 10 %<br />

4 15 %<br />

5 20 %<br />

6 25 %<br />

7 30%<br />

8 35 %<br />

9 40 %<br />

Note (*): the default value is set to ensure the best performance based on<br />

the configurator in the TY position.<br />

WARNING:<br />

For correct operation of the actuator, set the type of lamp to control<br />

using the configurator in the TY position.<br />

If the lamp does not switch on, or shows unstable operation, use the<br />

configurator in the MIN or VIRTUAL CONFIGURATION position to select<br />

the minimum level of light intensity, until a value is obtained that gives<br />

the possibility of adjusting the operation of the lamp.<br />

7. Wiring diagram<br />

L<br />

N<br />

In addition to the M position, also positions TY and MIN must be configured<br />

TY<br />

Configurator<br />

None or 0<br />

Type of<br />

load<br />

inductive<br />

LED<br />

1 inductive<br />

CFL<br />

2 capacitive<br />

LED<br />

3 capacitive<br />

CFL<br />

4 Halogen<br />

lamp<br />

Note: CFL = compact fluorescent lamp<br />

Minimum light Switch on mode<br />

intensity level<br />

(default)<br />

10 Switches on at<br />

minimum level,<br />

and then adjusts to<br />

the saved level<br />

37 Switches on at<br />

maximum level,<br />

and then adjusts to<br />

the saved level<br />

10 Switches on at<br />

minimum level,<br />

and then adjusts to<br />

the saved level<br />

37 Switches on at<br />

maximum level,<br />

and then adjusts to<br />

the saved level<br />

1 Switches on at<br />

minimum level,<br />

and then adjusts to<br />

the saved level<br />

230V<br />

C16<br />

T1,6H 250V<br />

220-240V ~ 50 - 60 Hz<br />

110-127V ~ 50 - 60 Hz<br />

12W19<br />

ID<br />

200W<br />

100W<br />

BUS SCS<br />

BT00594-a- EN 18/06/2012<br />