CP150 – 150 A, 10 MHz Current Probe<br />

CP500 – 500 A, 2 MHz Current Probe<br />

CP150 Features<br />

• 150 Arms continuous<br />

current<br />

• 500 A peak<br />

• 10 MHz bandwidth<br />

Current<br />

(A rms)<br />

160<br />

140<br />

120<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

Electrical Characteristics<br />

Max. Continuous 150 A<br />

Input Current<br />

Bandwidth<br />

10 MHz<br />

Max. Peak Current 500 A < 30 µs<br />

at Pulse Width<br />

Rise time (typical) < 35 ns<br />

Minimum Sensitivity 200 mA/div<br />

Max. In-Phase Current 500 A<br />

Low Frequency Accuracy 1%<br />

AC Noise<br />

25 mA<br />

Coupling<br />

AC, DC, GND<br />

General Characteristics<br />

Cable Length<br />

2 m<br />

Weight (probe only) 500 g<br />

Max. Conductor 20 mm<br />

Size (diameter) ProBus, 1 MΩ only †<br />

Interface<br />

Usage Environment Indoors<br />

Operating Temperature 0 °C to 40 °C<br />

Max. Relative Humidity 80%<br />

Max. Altitude 2000 m<br />

Maximum Insulated 600 V CAT II,<br />

Wire Voltage<br />

300 V CAT III<br />

† Requires AP-1M for use with 50 Ω input<br />

only oscilloscopes.<br />

Insertion<br />

Impedance<br />

Frequency (Hz)<br />

Maximum Input Current vs. Frequency<br />

1<br />

0.1<br />

0.01<br />

0.001<br />

Frequency (Hz)<br />

Insertion Impedance vs. Frequency<br />

(typical)<br />

CP500 Features<br />

• 500 Arms<br />

continuous current<br />

• 700 A peak<br />

• 2 MHz bandwidth<br />

Current<br />

(A rms)<br />

550<br />

500<br />

450<br />

400<br />

350<br />

300<br />

250<br />

200<br />

150<br />

100<br />

50<br />

0<br />

10 100 1 k 10 k 100 k 1 M 10 M<br />

Frequency (Hz)<br />

Electrical Characteristics<br />

Max. Continuous 500 A<br />

Input Current<br />

Bandwidth<br />

2 MHz<br />

Max. Peak Current 700 A<br />

at Pulse Width<br />

Rise time (typical) < 175 ns<br />

Minimum Sensitivity 200 mA/div<br />

Max. In-Phase Current 1150 A<br />

Low Frequency Accuracy 1%<br />

AC Noise<br />

25 mA<br />

Coupling<br />

AC, DC, GND<br />

General Characteristics<br />

Cable Length<br />

6 m<br />

Weight (probe only) 630 g<br />

Max. Conductor 20 mm<br />

Size (diameter) ProBus, 1 MΩ only †<br />

Interface<br />

Usage Environment Indoors<br />

Operating Temperature 0 °C to 40 °C<br />

Max. Relative Humidity 80%<br />

Max. Altitude 2000 m<br />

Maximum Insulated 600 V CAT II,<br />

Wire Voltage<br />

300 V CAT III<br />

† Requires AP-1M for use with 50 Ω input<br />

only oscilloscopes.<br />

Insertion<br />

Impedance<br />

Maximum Input Current vs. Frequency<br />

0.100<br />

0.010<br />

0.001<br />

Frequency (Hz)<br />

Insertion Impedance vs. Frequency<br />

(typical)<br />

6